Plan Review Details - Permit 20080703
| Plan Review Stops For Permit 20080703 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-12 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-12 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2021-10-12 14:18:37 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) WIRE SIZE GOING TO JOCKEY PUMP NOT PER 230.31 | | | | | | 230.31 SIZE AND RATING (A) GENERAL. UNDERGROUND SERVICE | | | CONDUCTORS SHALL HAVE SUFFICIENT AMPACITY TO CARRY THE | | | CURRENT FOR THE LOAD AS CALCULATED IN ACCORDANC E WITH | | | ARTICLE 220 AND S HALL HAVE ADEQUATE MECHANICAL | | | STRENGTH. (B) MINIMUM SIZE. THE CONDUCTORS SHALL NOT BE | | | SMALLER THAN 8 AWG COPPER OR 6 AWG ALUMINUM OR | | | COPPER-CLAD ALUMINUM. | | | | | | 2) DISCONNECT FOR JOCKEY PUMP SHALL NOT BE SMALLER THAN | | | 60A PER 230.79(D) |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-10-16 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-16 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-16 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2020-10-16 08:16:24 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) WIRE SIZE GOING TO JOCKEY PUMP NOT PER 230.31 | | | | | | 230.31 SIZE AND RATING (A) GENERAL. UNDERGROUND SERVICE | | | CONDUCTORS SHALL HAVE SUFFICIENT AMPACITY TO CARRY THE | | | CURRENT FOR THE LOAD AS CALCULATED IN ACCORDANC E WITH | | | ARTICLE 220 AND S HALL HAVE ADEQUATE MECHANICAL | | | STRENGTH. (B) MINIMUM SIZE. THE CONDUCTORS SHALL NOT BE | | | SMALLER THAN 8 AWG COPPER OR 6 AWG ALUMINUM OR | | | COPPER-CLAD ALUMINUM. | | | | | | 2) NEED TO SHOW WIRE SIZES IN GUTTER. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-12 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-09-08 |
Time |
15:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-10-16 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-16 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-17 |
Time |
10:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-12 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-12 |
Time |
14:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-10-16 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-16 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-16 |
Time |
08:17 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |