Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-09-21 Cont ID  
Sent By rmcdouga Date 2020-09-21 Time 16:56 Rev Time 0.00
Received By rmcdouga Date 2020-09-21 Time 16:56 Sent To  
Notes
2020-09-21 17:01:44THERE WAS NO SOUND TRANSMISSION TESTS FOR THE LAMINATE
 WOOD WITH THE PROFLEX RCU-250 OVER JUST AN 8" CONCRETE
 SLAB. HOWEVER, THERE WAS A TEST FOR TILE OVER THE
 RCU-250 AND AN 8" SLAB THAT MEETS THE SOUND INSULATION
 REQUIREMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-09-11 Cont ID  
Sent By rmcdouga Date 2020-09-11 Time 12:51 Rev Time 0.00
Received By rmcdouga Date 2020-09-11 Time 12:38 Sent To  
Notes
2020-09-11 12:38:01PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE AIR BORNE AND STRUCTURE BORNE TEST REPORTS THAT
 WERE SUBMITTED DO NOT REFLECT THE SITE CONDITIONS OF
 THE PROJECT. SUBMIT THE TEST REPORTS FOR A 6" CONCRETE
 FLOOR SLAB ASSEMBLY WITH NO CEILING OR INSULATION
 BELOW. THE REPORTS THAT WERE SUBMITTED HAVE A WOOD
 FRAME ASSEMBLY WITH 8" OF INSULATION.
 FBC 1207.2 AIR-BORNE SOUND. ASTM E 90-04, FBC 1207.3
 STRUCTURE-BORNE SOUND. ASTM E 492-09
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-28 Cont ID  
Sent By rmcdouga Date 2020-08-28 Time 15:10 Rev Time 0.00
Received By rmcdouga Date 2020-08-28 Time 15:10 Sent To  
Notes
2020-08-28 15:10:10PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) PROVIDE THE FOLLOWING INFORMATION FOR FLOORING
 SUBMITTALS:
  
 1. FLOOR PLAN WITH DIMENSIONS AND LOCATION OF WORK. -
 DESIGNER TO PRINT NAME AND SIGN PLAN PER FBC 107.
 2. TOTAL SQUARE FOOTAGE OF NEW FLOORING.
 3. TYPE OF PROPOSED HARD FLOORING (TILE, LAMINATE,
 WOOD, MARBLE, ETC.).
 4. STATED VALUE OF WORK.
 5. DESCRIPTION OF EXISTING SITE CONDITIONS:
 (A) THICKNESS OF SLAB (B) FLOOR/CEILING ASSEMBLY BELOW
 (EXPOSED CONCRETE, SUSPENDED GYPSUM OR ACOUSTICAL ).
 6. PROPOSED UNDERLAYMENT.
 7. TEST REPORTS FOR THE PROPOSED UNDERLAYMENT BASED ON
 THE EXISTING SITE CONDITIONS.
 8. TEST REPORTS MAY BE BASED ON THE FOLLOWING ASTM'S:
 E-84, E-90 & E-492.
 9. ALL DOCUMENTS SHALL BE SUBMITTED IN DUPLICATE.
 (UNLESS SUBMITTING ELECTRONICALLY)
  
 FBC 603.1 FLAME SPREAD - ASTM E 84-09
  
 FBC 1207.2 AIR-BORNE SOUND. ASTM E 90-04
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E 492-09
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 SUBMIT THE TEST REPORTS FOR THE SOUND INSULATION
 INCLUDING FLAME SPREAD AND SMOKE DEVELOPED FOR THE
 APPLICABLE CONSTRUCTION CONDITIONS.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-09-21 Cont ID  
Sent By rmcdouga Date 2020-09-21 Time 17:01 Rev Time 0.00
Received By rmcdouga Date 2020-09-17 Time 14:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-11 Cont ID  
Sent By rmcdouga Date 2020-09-11 Time 12:51 Rev Time 0.00
Received By rmcdouga Date 2020-09-08 Time 10:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-28 Cont ID  
Sent By rmcdouga Date 2020-08-28 Time 15:10 Rev Time 0.00
Received By rmcdouga Date 2020-08-11 Time 09:08 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-08-28 Cont ID  
Sent By rmcdouga Date 2020-08-28 Time 15:10 Rev Time 0.00
Received By rmcdouga Date 2020-08-28 Time 15:10 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved