Plan Review Details - Permit 20080382
Plan Review Stops For Permit 20080382
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2020-10-15 Cont ID  
Sent By cpuell Date 2020-10-15 Time 16:52 Rev Time 0.00
Received By cpuell Date 2020-10-15 Time 16:52 Sent To  
Notes
2020-10-15 16:52:38HOUSE HOUSE GIVEN THE ADDRESS OF 365 SOPHIA DR

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2020-10-10 Cont ID  
Sent By cpuell Date 2020-10-10 Time 13:47 Rev Time 0.00
Received By cpuell Date 2020-10-10 Time 13:47 Sent To  
Notes
2020-10-10 13:48:33PLEASE REACH OUT TO [email protected] TO ESTABLISH AN
 ADDRESS FOR THE GUEST HOUSE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-10-10 Cont ID  
Sent By pvalenti Date 2020-10-10 Time 11:37 Rev Time 0.00
Received By pvalenti Date 2020-10-10 Time 11:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-10-06 Cont ID  
Sent By pvalenti Date 2020-10-06 Time 16:00 Rev Time 0.00
Received By pvalenti Date 2020-10-05 Time 08:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-09-16 Cont ID  
Sent By pvalenti Date 2020-09-16 Time 13:14 Rev Time 0.00
Received By pvalenti Date 2020-09-15 Time 17:25 Sent To  
Notes
2020-09-16 13:30:22PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1, PLEASE PROVIDE THE FOLLOWING:
  
 1) PROVIDE DESIGNER OF RECORD DETAIL OF KEY NOTE 15
 FROM PAGE A-1.02 FOR METHOD OF NEW SLAB TIE IN TO
 EXISTING SLAB.
 2) PROVIDE DESIGNER OF RECORD CLARIFICATION OF KEY NOTE
 2 FROM PAGE A-1.02 FOR EXISTING TIEBEAM REMAINS AT
 SOUTH WALL OR DETAILS FOR NEW TIEBEAM.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-10-08 Cont ID  
Sent By jleahy Date 2020-10-08 Time 08:21 Rev Time 0.00
Received By jleahy Date 2020-10-08 Time 08:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2020-10-01 Cont ID  
Sent By jleahy Date 2020-10-01 Time 14:04 Rev Time 0.00
Received By jleahy Date 2020-10-01 Time 13:19 Sent To  
Notes
2020-10-01 14:07:57ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 A/C AT COTTAGE ARE FED FROM A DIFFERENT SOURCE PER
 225.31 YOU WILL NEED TO SET A DISCONNECT NEXT TO THE
 PANEL ON THE OUTSIDE OF THE COOTAGE AND LABEL IT A 1 OF
 2 AND 2 OF 2 FOR THE DISCONNECTING MEANS TO THE
 COTTAGE.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-09-08 Cont ID  
Sent By cthroop Date 2020-09-08 Time 16:27 Rev Time 0.00
Received By cthroop Date 2020-09-08 Time 14:48 Sent To  
Notes
2020-09-08 16:42:46PLAN REVIEW / ELECTRICAL
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC 2014
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE GROUNDING ELETRODE SYSTEM FOR NEW 125
 SUB-PANEL PER E3607.3.
 PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A
 BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH
 CIRCUIT. NEC 250.32; FBC RE3607.3
 NEC 250.32; FBC RE E3607.3
 A GROUNDING ELECTRODE SYSTEM IS REQUIRED TO BE
 ESTABLISHED AT EACH SEPARATE BUILDING OR STRUCTURE AND
 CONNECTED TOGETHER. PROVIDE DETAILS ON PLAN OF
 GROUNDING ELECTRODE SYSTEM AND WIRING.
  
 2. PROVIDE DISCONNECTING MEANS FOR NEW 125A SUB-PANEL
 PER NEC 225.31 AND NEC 225.32.
 FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A
 DISCONNECTING MEANS AT THE BUILDING OR SEPARATE
 STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR
 MAIN BREAKER AT THE PANEL FOR PANEL A. NEC 225.31,
 225.32
 E3601.6SERVICE DISCONNECT REQUIRED.
 MEANS SHALL BE PROVIDED TO DISCONNECT ALL CONDUCTORS IN
 A BUILDING OR OTHER STRUCTURE FROM THE SERVICE ENTRANCE
 CONDUCTORS. (230.70)
  
 3. IDENTIFY LOCATION OF W/H, AHU AND C/U ON ELECTRICAL
 PLAN.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 4. INCLUDE W/H CIRCUT ON PANEL SCHEDULE.
 PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5,
 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902
  
 5. PROVIDE SERVICE OUTLET FOR C/U.
 E3901.12 HVAC OUTLET.
 A 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE-RATED
 RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE
 LOCATION FOR THE SERVICING OF HEATING, AIR-CONDITIONING
 AND REFRIGERATION EQUIPMENT. THE RECEPTACLE SHALL BE
 LOCATED ON THE SAME LEVEL AND WITHIN 25 FEET (7620 MM)
 OF THE HEATING, AIR-CONDITIONING AND REFRIGERATION
 EQUIPMENT. THE RECEPTACLE OUTLET SHALL NOT BE CONNECTED
 TO THE LOAD SIDE OF THE HVAC EQUIPMENT DISCONNECTING
 MEANS. (210.63)
  
 6. PROVIDE EXT. OUTLETS AT FRONT AND REAR OF UNIT.
 E3901.7 OUTDOOR OUTLETS.
 NOT LESS THAN ONE RECEPTACLE OUTLET THAT IS READILY
 ACCESSIBLE FROM GRADE LEVEL AND LOCATED NOT MORE THAN 6
 FEET, 6 INCHES (1981 MM) ABOVE GRADE, SHALL BE
 INSTALLED OUTDOORS AT THE FRONT AND BACK OF EACH
 DWELLING UNIT HAVING DIRECT ACCESS TO GRADE LEVEL.
 BALCONIES, DECKS, AND PORCHES THAT ARE ACCESSIBLE FROM
 INSIDE OF THE DWELLING UNIT SHALL HAVE AT LEAST ONE
 RECEPTACLE OUTLET INSTALLED WITHIN THE PERIMETER OF THE
 BALCONY, DECK, OR PORCH. THE RECEPTACLE SHALL BE
 LOCATED NOT MORE THAN 6 FEET, 6 INCHES (1981 MM) ABOVE
 THE BALCONY, DECK, OR PORCH SURFACE. [210.52(E)]
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2020-10-05 Cont ID  
Sent By fmittner Date 2020-10-05 Time 13:35 Rev Time 0.00
Received By fmittner Date 2020-10-05 Time 13:35 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-09-09 Cont ID  
Sent By fmittner Date 2020-09-09 Time 10:22 Rev Time 0.00
Received By fmittner Date 2020-09-09 Time 10:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-10-10 Cont ID  
Sent By pvalenti Date 2020-10-10 Time 11:38 Rev Time 0.00
Received By pvalenti Date 2020-10-07 Time 15:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-10-06 Cont ID  
Sent By pvalenti Date 2020-10-06 Time 16:07 Rev Time 0.00
Received By pvalenti Date 2020-09-25 Time 14:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-09-16 Cont ID  
Sent By pvalenti Date 2020-09-16 Time 13:30 Rev Time 0.00
Received By pvalenti Date 2020-09-02 Time 19:11 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2020-10-08 Cont ID  
Sent By medwards Date 2020-10-08 Time 09:43 Rev Time 0.00
Received By medwards Date 2020-10-08 Time 09:31 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-09-26 Cont ID  
Sent By medwards Date 2020-09-26 Time 10:49 Rev Time 0.00
Received By medwards Date 2020-09-26 Time 10:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-09-08 Cont ID  
Sent By medwards Date 2020-09-08 Time 10:52 Rev Time 0.00
Received By medwards Date 2020-09-08 Time 10:14 Sent To  
Notes
2020-09-08 10:53:111ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20080382
  
 CODES IN EFFECT:
  
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE ENERGY SUBMITTAL. FBC EC 101.5.1.1.2
  
 2) PROVIDE EQUIPMENT SIZING CALCULATIONS. FBC EC R403.7
  
 3) PROVIDE ANCHORAGE DETAILS FOR THE CU. FBC RES
 M1307.2
  
 4) SHOW BATHROOM EXHAUST. FBC RES TABLE M1507.4.
  
 5) SHOW KITCHEN EXHAUST. FBC RES TABLE M1507.4
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-09-29 Cont ID  
Sent By lcrespo Date 2020-09-29 Time 14:47 Rev Time 0.00
Received By lcrespo Date 2020-09-29 Time 14:33 Sent To  
Notes
2020-09-29 14:47:259/29/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-09-04 Cont ID  
Sent By lcrespo Date 2020-09-04 Time 13:22 Rev Time 0.00
Received By lcrespo Date 2020-09-04 Time 11:40 Sent To  
Notes
2020-09-04 13:22:2309/04/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 THERE IS NO EXISTING PERMIT FOR THIS STRUCTURE ON FILE
 AND WORK MAY HAVE BEEN DONE WITHOUT A PERMITS OR
 INSPECTIONS. THE STRUCTURE WAS AN EXISTING GARAGE AT
 ONE POINT. THE WORD EXISTING OF ITEMS DOES NOT
 CONSTITUTE PERMITTED WORK SO A FULL EVALUATION AND
 REQUIRED INSPECTION WILL TAKE PLACE ALONG WITH PLANS
 AND SPORTING DOCUMENTS.
  
 1. SIGNED AND SEALED DRAWINGS NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW - OR -
 IF YOUR ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL
 SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE
 ORIGINAL SIGNED AND SEALED DOCUMENT ALONG WITH A "PLAN
 REVIEW REQUEST FORM" EXPLAINING THE REASON FOR
 SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW
 REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected]
 AND ASKING FOR THE FORM.
  
 2. A REDUCED PRESSURE ZONE ASSEMBLY REQUIRED SINCE THIS
 A DUAL DWELLING PER THE CITY OF WEST PALM BEACH ORD
 #2853-95. A PERMIT REQUIRED BY A LICENSED CONTRACTOR
 AND MUST BE CERTIFIED BY UTILITIES PRIOR TO FINAL
 INSPECTION. PLEASE CONTACT THE CITY OF WPB UTILITIES AT
 561-822-2240 FOR FURTHER DIRECTIONS.
  
 3. A SUB PLUMBING PERMIT IS REQUIRED BY A LICENSED
 CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS
 TO THE FBC SEC. 105.1.
  
 4. PLEASE SHOW THE SOURCE OF HOT WATER FOR THE
 STRUCTURE PER THE 2017 FBC SEC. R 2722.2.
  
 5. WASHING MACHINE VALVES MUST BE ACCESSIBLE FOR
 SHUTTING OFF WITHOUT MOVING UNITS PER THE 2017 FBC SEC.
 R2903.9.3 FIXTURE VALVES AND ACCESS. ACCESSIBLE
 SIGNIFIES ACCESS THAT REQUIRES THE REMOVAL OF AN ACCESS
 PANEL OR SIMILAR REMOVABLE OBSTRUCTION.
  
 6. PLEASE SHOW WATER SERVICE SUPPLY AND SHUT OFF VALVE
 PER THE 2017 FBC SEC. R 306.4.
  
 7. PLEASE SHOW A CLEAN-OUT ON ISOMETRIC DIAGRAM FOR THE
 SEWER JUNCTION PER THE 2017 FBC SEC. 3005.2.3.
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-10-08 Cont ID  
Sent By medwards Date 2020-10-08 Time 09:45 Rev Time 0.00
Received By medwards Date 2020-10-08 Time 09:45 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-10-05 Cont ID  
Sent By pvalenti Date 2020-10-05 Time 08:48 Rev Time 0.00
Received By pvalenti Date 2020-10-05 Time 08:32 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-09-08 Cont ID  
Sent By medwards Date 2020-09-08 Time 10:55 Rev Time 0.00
Received By medwards Date 2020-09-08 Time 10:55 Sent To  
Notes
2020-09-08 10:56:06PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 IS REQUIRED TO BE SIGNED AND SEALED BY THE PERSON
 RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A
 DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY
 VERIFICATION. PROVIDE CORRECTION. ALTERNATIVELY, A
 SIGNED/SEALED PAPER SET MAY BE SUPPLIED TO THE BUILDING
 DEPARTMENT WHEN ALL TRADES ARE APPROVED. WPB FBC 107.1;
 FS 471/481
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2020-10-05 Cont ID  
Sent By fmittner Date 2020-10-05 Time 13:35 Rev Time 0.00
Received By fmittner Date 2020-10-05 Time 13:35 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-09-09 Cont ID  
Sent By fmittner Date 2020-09-09 Time 10:22 Rev Time 0.00
Received By fmittner Date 2020-09-09 Time 10:22 Sent To  
Notes
***NONE***