Plan Review Details - Permit 20080353
Plan Review Stops For Permit 20080353
Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-11-03 Cont ID  
Sent By medwards Date 2020-11-03 Time 07:00 Rev Time 0.00
Received By medwards Date 2020-10-27 Time 08:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-10-14 Cont ID  
Sent By medwards Date 2020-10-14 Time 07:52 Rev Time 0.00
Received By medwards Date 2020-10-13 Time 14:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-15 Cont ID  
Sent By pvalenti Date 2020-08-15 Time 12:37 Rev Time 0.00
Received By pvalenti Date 2020-08-12 Time 16:42 Sent To  
Notes
2020-08-12 16:43:09ROUTED TO MECH INBOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2020-11-03 Cont ID  
Sent By medwards Date 2020-11-03 Time 07:00 Rev Time 0.00
Received By medwards Date 2020-11-03 Time 06:50 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-10-14 Cont ID  
Sent By medwards Date 2020-10-14 Time 07:49 Rev Time 0.00
Received By medwards Date 2020-10-14 Time 06:47 Sent To  
Notes
2020-10-14 07:49:501ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20080353
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE THE OCCUPANCY AND USE OF SPACE FOR
 THIS BUILDING. FBC M TABLE 403.3.1.1
  
 2) PLEASE PROVIDE OUTSIDE AIR CALCULATIONS FOR USE OF
 THIS BUILDING BROKEN DOWN TO EACH AHU. FBC M TABLE
 403.3.1.1
  
 3) REST ROOM B3 IS MISSING AN EXHAUST FAN. PLEASE SHOW
 HOW THIS ROOM WILL BE VENTILATED. FBC M TABLE 403.3.2.3
  
 4) SHEET M0: EF-1 INDICATES AREA SERVED AS MASTER BATH,
 THIS IS A COMMERCIAL BUILDING. PLEASE INDICATE THE
 CORRECT NAME OF THE LOCATION OF THE EF-1. FBC 107.2.1
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-08-15 Cont ID  
Sent By pvalenti Date 2020-08-15 Time 12:37 Rev Time 0.00
Received By pvalenti Date 2020-08-15 Time 12:16 Sent To  
Notes
2020-08-15 12:36:31PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 MECHANICAL REVIEW DENIED:
  
 FBC B 107, PROVIDE THE FOLLOWING INFORMATION:
  
 1) FBC M 304.1, PROVIDE MOUNTING DETAILS FOR AIR
 HANDLER UNITS 3,4 & 5.
 2) FBC M 304.1 & 301.15, PROVIDE MOUNTING DETAILS FOR
 THE OUTSIDE AIR ROOF TOP INTAKES.
 3) FBC M 603.18, FBC M 603.3, PROVIDE LOCATIONS OF ALL
 ACCESS DOORS FOR SMOKE DETECTORS, DAMPERS AND
 REGISTERS.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-11-03 Cont ID  
Sent By medwards Date 2020-11-03 Time 07:00 Rev Time 0.00
Received By medwards Date 2020-11-03 Time 07:00 Sent To  
Notes
***NONE***