Plan Review Details - Permit 20080325
Plan Review Stops For Permit 20080325
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-10-22 Cont ID  
Sent By rmcphers Date 2020-10-22 Time 10:09 Rev Time 0.00
Received By rmcphers Date 2020-10-22 Time 10:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-09-16 Cont ID  
Sent By rmcphers Date 2020-09-16 Time 13:50 Rev Time 0.00
Received By rmcphers Date 2020-09-16 Time 12:29 Sent To  
Notes
2020-09-16 13:50:17SFR ADDITION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW ALL STAIR RISER HEIGHTS TO HAVE A MAX.
 3/8" DIFFERENCE FBC R311.7.5
 2) PLEASE SHOW TREAD DEPTHS TO COMPLY WITH FBC R311.7.5
 3) PLEASE SHOW NEW ADDITION ATTIC AREA VENTILATION TO
 COMPLY WITH FBC R807
 4) PLEASE SHOW THE LOCATION AND SIZE OF THE ATTIC
 ACCESS TO THE NEW ADDITION - FBC R807
 5) PRODUCT APPROVAL (FL243 R21) HAS EXPIRED - PLEASE
 PROVIDE AN UPDATED PRODUCT APPROVAL FOR THE FIXED
 GLASS.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-08-24 Cont ID  
Sent By cthroop Date 2020-08-24 Time 13:13 Rev Time 0.00
Received By cthroop Date 2020-08-24 Time 11:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-10-22 Cont ID  
Sent By rmcphers Date 2020-10-22 Time 10:10 Rev Time 0.00
Received By rmcphers Date 2020-10-14 Time 16:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-10-14 Cont ID  
Sent By shill Date 2020-10-14 Time 10:07 Rev Time 0.00
Received By shill Date 2020-08-07 Time 16:39 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2020-11-25 Cont ID  
Sent By ccarvaja Date 2020-11-25 Time 09:57 Rev Time 0.00
Received By ccarvaja Date 2020-11-10 Time 14:17 Sent To  
Notes
2020-11-23 15:16:55RECEIPT - MU-2020-044119 - $1945.04 - PAID
2020-11-10 14:17:4311/10/20 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-09-16 Cont ID  
Sent By rmcphers Date 2020-09-16 Time 13:56 Rev Time 0.00
Received By rmcphers Date 2020-09-16 Time 13:55 Sent To  
Notes
2020-09-16 13:56:49PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-08-13 Cont ID  
Sent By hmoser Date 2020-08-13 Time 15:12 Rev Time 0.00
Received By hmoser Date 2020-08-13 Time 14:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-10-15 Cont ID  
Sent By ccole Date 2020-10-15 Time 10:52 Rev Time 0.00
Received By ccole Date 2020-10-15 Time 07:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-08-20 Cont ID  
Sent By ccole Date 2020-08-20 Time 07:53 Rev Time 0.00
Received By ccole Date 2020-08-19 Time 15:15 Sent To  
Notes
2020-08-20 07:54:041ST REVIEW FBC-2017 RES.
 PERMIT- 20080325
 8/20/2020
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P-1: THE ISOMETRIC DRAWING APPEARS TO SHOW THE
 2" TUB DRAIN CONNECTING VERTICALLY INTO THE WET VENT.
 THE DRAIN SHALL CONNECT HORIZONTALLY OTHERWISE IT MUST
 BE INDIVIDUALLY VENTED- SECTION P3108.1 FBC RES.
  
 2) A2 & P-1: PLEASE PROVIDE A SCOPE OF WORK FOR THE
 WATER HEATER. IT APPEARS TO BE A REPLACEMENT OF THE
 EXISTING. PLEASE PROVIDE AN EQUIPMENT SCHEDULE ON THE
 PLAN THAT INCLUDES THE EFFICIENCY RATING OF THE
 APPLIANCE, AND SUBMIT MANUFACTURER'S SPECIFICATIONS-
 TABLE C404.2 FBC EC AND SECTION P2801.3 FBC RES.
  
 3) A2 & P1: INDICATE HOW THE WH IN THE GARAGE WILL BE
 PROTECTED AGAINST VEHICLE IMPACT- SECTIONS P2801.4,
 P2801.5, & M1307.3.1 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2020-09-16 Cont ID  
Sent By rmcphers Date 2020-09-16 Time 13:50 Rev Time 0.00
Received By rmcphers Date 2020-09-16 Time 13:50 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-10-22 Cont ID  
Sent By rmcphers Date 2020-10-22 Time 10:10 Rev Time 0.00
Received By rmcphers Date 2020-10-22 Time 10:10 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-09-16 Cont ID  
Sent By rmcphers Date 2020-09-16 Time 13:55 Rev Time 0.00
Received By rmcphers Date 2020-09-16 Time 13:55 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-10-14 Cont ID  
Sent By kalexand Date 2020-10-14 Time 08:37 Rev Time 0.00
Received By kalexand Date 2020-10-14 Time 08:37 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved