| Plan Review Stops For Permit 20080080 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-09-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-16 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-16 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-04 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-04 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2020-08-04 15:06:48 | PLAN REVIEW - BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS. | | | | | | 2. PROVIDE PRODUCT APPROVALS FOR ALUMINUM FIXED LOUVER | | | TRELLIS. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW MULLION SUBMITTALS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-09-10 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-09-10 |
Time |
23:57 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-09-10 |
Time |
23:56 |
Sent To |
|
|
| Notes |
| 2020-09-10 23:57:12 | SEPARATE PERMIT REQUIRED FOR GENERATOR AND LOW VOLTAGE |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-04 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-04 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2020-08-04 15:04:22 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PLAN MUST BE DIGITALLY SIGNED BY DESIGN PROFESSIONAL | | | AND HAVE THIRD PARTY VERFICATION I.E. ADOBE OR ANOTHER | | | EQUIVALENT. | | | | | | 2. PLAN IS BLURRY AND NOT READABLE. PLEASE TRY TO | | | UPLOAD ELECTRICAL DRAWINGS AGAIN. OR DIRECTLY EMAIL PDF | | | TO [email protected] | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-08-04 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-08-04 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2020-08-04 12:23:26 | A SEPARATE PERMIT IS REQUIRED FOR THE GAS PIPING | | | INSTALLATION- SECTION 107.2.1 WPB. COMPLETE PLANS AND | | | SPECIFICATIONS SHALL BE SUBMITTED FOR REVIEW. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-09-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-16 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-16 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2020-09-16 16:25:56 | SEE PERMIT 20060770. HISTORIC PASSED BY FM. CT |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-08-04 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-08-04 |
Time |
12:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-09-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-16 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-31 |
Time |
10:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-04 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-04 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2020-08-04 10:02:57 | PLANS UNDER 20060770 IN PROJECTDOX |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-10-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-10-08 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-09-25 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2020-10-08 15:31:45 | NO FEES DUE PER IMPACT OFFICE. LEM | | 2020-09-25 13:18:10 | 9/25/20 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-04 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-04 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2020-08-04 15:07:38 | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-09-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-16 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-16 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-08-04 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-08-04 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-09-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-16 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-16 |
Time |
16:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-08-04 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-08-04 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2020-08-04 12:41:19 | | | | THE PLUMBING FOR THE CABANA IS APPROVED, HOWEVER A | | | BACKFLOW PREVENTER MAY BE REQUIRED BY THE CITY OF WPB | | | UTILITIES DEPARTMENT BECAUSE OF THE SHARED WATER | | | SERVICE SUPPLYING THE TWO BUILDINGS ONSITE. PLEASE | | | CONTACT THE DEPT. AT 561-822-2210 FOR INFORMATION.THIS | | | NOTE WILL BE STAMPED ON THE PLANS AT FINAL REVIEW OF | | | THE MAIN HOUSE PLANS UNDER PERMIT-20060770. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-04 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-04 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-09-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-16 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-16 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2020-09-16 16:28:16 | NO NOTES |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-04 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-04 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2020-08-04 15:05:33 | PLAN REVIEW - DIGITAL SIGNATURES AND SEALS | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1) DESIGN PROFESSIONALS DIGITAL SIGNATURE IS REQUIRED | | | ON ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC | | | 61G15 | | | | | | 2) DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 3) UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | 4) FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | | | NOTE: YOU MAY PROVIDE A PAPER PLAN WITH WET SIGNATURE | | | AND SEAL PRIOR TO PERMIT. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-09-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-16 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-16 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2020-09-16 16:27:00 | SEE PERMIT 20060770. ZONING PASSED BY FM. CT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-08-04 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-08-04 |
Time |
12:51 |
Sent To |
|
|
| Notes |
|
|