Plan Review Details - Permit 20080030
Plan Review Stops For Permit 20080030
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-09-25 Cont ID  
Sent By rmcdouga Date 2020-09-25 Time 09:03 Rev Time 0.00
Received By rmcdouga Date 2020-09-25 Time 08:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-20 Cont ID  
Sent By rmcdouga Date 2020-08-20 Time 13:21 Rev Time 0.00
Received By rmcdouga Date 2020-08-20 Time 12:49 Sent To  
Notes
2020-08-20 13:34:08PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 1) THE PHOTOGRAPHS AND THE POOL SHOWN ON THE SURVEY
 THAT WAS SUBMITTED DO NOT MATCH. THE SURVEY SHOWS THE
 SPA AT THE END OF THE POOL THAT IS AWAY FROM THE HOUSE
 AND THE PHOTOS SHOW THE SPA AT THE OPPOSITE END OF THE
 POOL. PLEASE SUBMIT THE SURVEY THAT SHOWS THAT THE
 EXISTING POOL MATCHES THE PHOTOS OF THE POOL. CITY
 AMENDMENTS FBC107.2.1
  
 2) SUBMIT A CONSTRUCTION DOCUMENT THAT CLEARLY
 SPECIFIES THE TOTAL SCOPE OF WORK. CITY AMENDMENTS FBC
 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-09-22 Cont ID  
Sent By jleahy Date 2020-09-22 Time 10:46 Rev Time 0.00
Received By jleahy Date 2020-09-21 Time 13:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-08-19 Cont ID  
Sent By jleahy Date 2020-08-19 Time 14:34 Rev Time 0.00
Received By jleahy Date 2020-08-19 Time 14:31 Sent To  
Notes
2020-08-19 14:43:55ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 680.26 EQUIPOTENTIAL BONDING (A) PERFORMANCE. THE
 EQUIPOTENTIAL BONDING REQUIRED BY THIS SECTION SHALL BE
 INSTALLED TO REDUCE VOLTAGE GRADIENTS IN THE POOL AREA.
 (B) BONDED PARTS. THE PARTS SPECIFIED IN 680.26(B)(1)
 THROUGH (B)(7) SHALL BE BONDED TOGETHER USING SOLID
 COPPER CONDUCTORS, INSULATED COVERED, OR BARE, NOT
 SMALLER THAN 8 AWG OR WITH RIGID METAL CONDUIT OF BRASS
 OR OTHER IDENTIFIED CORROSI ON-RESISTANT METAL.
  
 POOL LIGHTS LOOK AS IF THEY WERE REPLACED, NEED TO SHOW
 WHAT TYPE OF FIXTURES ARE BEING USED.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-25 Cont ID  
Sent By rmcdouga Date 2020-09-25 Time 09:04 Rev Time 0.00
Received By rmcdouga Date 2020-09-11 Time 07:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-09-01 Cont ID  
Sent By rmcdouga Date 2020-09-01 Time 12:15 Rev Time 0.00
Received By rmcdouga Date 2020-08-18 Time 15:18 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-09-14 Cont ID  
Sent By lcrespo Date 2020-09-14 Time 08:31 Rev Time 0.00
Received By lcrespo Date 2020-09-14 Time 08:31 Sent To  
Notes
2020-09-14 08:32:35ACCORDING TO THE SCOPE OF WORK THERE IS NO PLUMBING TO
 BE DONE ON POOL.

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-08-19 Cont ID  
Sent By tklarge Date 2020-08-19 Time 10:12 Rev Time 0.00
Received By tklarge Date 2020-08-19 Time 10:09 Sent To  
Notes
2020-08-19 10:16:05PROVIDE A COPY OF THE WORK INVOICE FOR THIS PROJECT AND
 A LETTER FROM THE CONTRACTOR THAT DESCRIBES THE SCOPE
 OF WORK TO BE DONE.. IT IS UNCLEAR FROM THE PICTURES
 WHETHER ANY WORK WAS DONE ON THE MAIN DRAIN, POOL
 PIPING OR SKIMMER.WPB AMEND. TO FBC SEC. 107.2.1.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2020-09-25 Cont ID  
Sent By rmcdouga Date 2020-09-25 Time 09:04 Rev Time 0.00
Received By rmcdouga Date 2020-09-25 Time 08:45 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-08-20 Cont ID  
Sent By rmcdouga Date 2020-08-20 Time 13:21 Rev Time 0.00
Received By rmcdouga Date 2020-08-20 Time 13:21 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-09-01 Cont ID  
Sent By rthermid Date 2020-09-01 Time   Rev Time  
Received By rthermid Date 2020-09-01 Time   Sent To I
Notes
***NONE***