| Plan Review Stops For Permit 20071488 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-12-29 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-12-28 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-12-28 |
Time |
08:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2020-12-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-12-14 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-12-14 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2020-12-14 08:03:10 | ROOFED PATIO | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | 3RD REVIEW | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) MASONRY WALLS ARE SUBJECT TO WIND LOADS - PLEASE | | | SHOW THE WIND DESIGN CRITERIA USED FOR DESIGN ON THE | | | MASONRY WALL DRAWINGS- FBC 1603.1.4 | | | 2) BUILDING CONSTRUCTION TYPE SHOWN ON DRAWING (A0.0) | | | NEEDS TO BE FOR THE ENTIRE BUILDING. (VB - SPRINKLERED) | | | - DRAWING SHOWS NON-SPRINKLERED | | | 3) WIND DESIGN SPEED SHOWN ON THE ALUMINUM SCREEN ROOM | | | CALCULATIONS SHOULD BE (180MPH) PER FBC WPB AMENDMENTS | | | 120.1 | | | 4) PLEASE PROVIDE SCREEN ROOM DRAWINGS OR PROVIDE IN | | | WRITING THAT THEY ARE TO BE DEFERRED.FBC 107.3.4.1 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-10-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-07 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-06 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2020-10-07 08:54:56 | ROOFED PATIO | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | 2ND REVIEW | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) THE ROOFED PATIO IS PART OF THE "FIRE AREA" AND IS | | | REQUIRED TO BE SPRINKLERED. FBC CHAPTER 2 - FIRE AREA. | | | THE AGGREGATE FLOOR AREA ENCLOSED AND BOUNDED BY FIRE | | | WALLS, FIRE BARRIERS, EXTERIOR WALLS OR HORIZONTAL | | | ASSEMBLIES OF A BUILDING. AREAS OF THE BUILDING NOT | | | PROVIDED WITH SURROUNDING WALLS SHALL BE INCLUDED IN | | | THE FIRE AREA IF SUCH AREAS ARE INCLUDED WITHIN THE | | | HORIZONTAL PROJECTION OF THE ROOF OR FLOOR NEXT ABOVE. | | | 903.2.1.2 GROUP A-2. | | | AN AUTOMATIC SPRINKLER SYSTEM SHALL BE PROVIDED FOR | | | FIRE AREAS CONTAINING GROUP A-2 OCCUPANCIES AND | | | INTERVENING FLOORS OF THE BUILDING WHERE ONE OF THE | | | FOLLOWING CONDITIONS EXISTS: (2).THE FIRE AREA HAS AN | | | OCCUPANT LOAD OF 100 OR MORE | | | EXCEPTION: A RESTAURANT, CAFETERIA, OR SIMILAR DINING | | | FACILITY, INCLUDING AN ASSOCIATED COMMERCIAL KITCHEN, | | | IS REQUIRED TO HAVE SPRINKLERS ONLY IF IT HAS A FIRE | | | AREA OCCUPANCY LOAD OF 200 PATRONS OR MORE. | | | 2) MASONRY WALLS ARE SUBJECT TO WIND LOADS - PLEASE | | | SHOW THE WIND DESIGN CRITERIA USED FOR DESIGN - FBC | | | 1603.1.4 | | | 3) BUILDING CONSTRUCTION TYPE SHOWN ON DRAWING (A0.0) | | | NEEDS TO BE FOR THE ENTIRE BUILDING. (VB - SPRINKLERED) | | | 4) WIND DESIGN SPEED SHOWN ON THE ALUMINUM SCREEN ROOM | | | CALCULATIONS SHOULD BE (180MPH) PER FBC WPB AMENDMENTS | | | 120.1 | | | 5) PLEASE PROVIDE SCREEN ROOM DRAWINGS OR PROVIDE IN | | | WRITING THAT THEY ARE TO BE DEFERRED.FBC 107.3.4.1 | | | | | | FYI = FBC 901.7 FIRE AREAS. | | | WHERE BUILDINGS, OR PORTIONS THEREOF, ARE DIVIDED INTO | | | FIRE AREAS SO AS NOT TO EXCEED THE LIMITS ESTABLISHED | | | FOR REQUIRING A FIRE PROTECTION SYSTEM IN ACCORDANCE | | | WITH THIS CHAPTER, SUCH FIRE AREAS SHALL BE SEPARATED | | | BY FIRE BARRIERS CONSTRUCTED IN ACCORDANCE WITH SECTION | | | 707 OR HORIZONTAL ASSEMBLIES CONSTRUCTED IN ACCORDANCE | | | WITH SECTION 711, OR BOTH, HAVING A FIRE-RESISTANCE | | | RATING OF NOT LESS THAN THAT DETERMINED IN ACCORDANCE | | | WITH SECTION 707.3.10. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-09-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-16 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-16 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2020-09-16 11:28:45 | ROOFED PATIO | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE A LIFE SAFEY PLAN FOR THE BUILDING | | | SHOWING - OCCUPANT LOAD, EXIT ACCESS TRAVEL DISTANCE TO | | | THE EXIT DISCHARGE, EXIT SIZES, SPRINKLERS ETC. FBC | | | 1001.1 | | | 2) PLEASE SHOW THE STAIR RISER HEIGHT AND TREAD DEPTH | | | TO COMPLY WITH FBC 1011.5 | | | 3) PLEASE SHOW THE WIND DESIGN CRITERIA USED FOR DESIGN | | | - FBC 1603.1.4 | | | 4) DRAWING (A0.0) SHOWS CONSTRUCTION TYPE AS "V" - SHOW | | | "V A" OR "V B" - SHOW SPRINKLERED OR NON SPRINKLERED. | | | FBC 506 | | | 5) PLEASE SHOW BUILDING SQ. FOOTAGE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-12-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-12-11 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-12-11 |
Time |
13:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-08-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-08-29 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-08-29 |
Time |
12:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2020-12-08 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-12-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-12-08 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2020-09-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-09-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-09-28 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2020-09-29 10:58:29 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | A RESPONSE TO PREVIOUS COMMENT # 2 WAS NOT CLEARLY | | | ADDRESSED WHICH HAS BEEN RESUBMITTED BELOW: | | | | | | | | | 2) THERE ARE NO INDICATIONS OF AN EXISTING FIRE | | | SPRINKLER OR FIRE ALARM SYSTEM. WITH THE CREATION OF | | | THIS NEW OCCUPIABLE INDOOR SPACE, THE LIFE SAFETY | | | SYSTEMS SHALL BE EXTENDED. | | | | | | PER NFPA 101, CH 4 | | | | | | 4.6.7 BUILDING REHABILITATION. | | | 4.6.7.1 REHABILITATION WORK ON EXISTING BUILDINGS SHALL | | | BE | | | CLASSIFIED AS ONE OF THE FOLLOWING WORK CATEGORIES IN | | | ACCORDANCE | | | WITH 43.2.2.1: | | | (1) REPAIR | | | (2) RENOVATION | | | (3) MODIFICATION | | | (4) RECONSTRUCTION | | | (5) CHANGE OF USE OR OCCUPANCY CLASSIFICATION | | | (6) ADDITION | | | | | | 43.8.3 FIRE PROTECTION SYSTEMS. IN OTHER THAN ONE- AND | | | TWOFAMILY | | | DWELLINGS, EXISTING COMPARTMENT AREAS WITHOUT AN | | | APPROVED SEPARATION FROM THE ADDITION SHALL BE | | | PROTECTED BY AN | | | APPROVED AUTOMATIC SPRINKLER SYSTEM WHERE THE COMBINED | | | AREAS | | | WOULD BE REQUIRED TO BE SPRINKLERED BY THE PROVISIONS | | | APPLICABLE | | | TO NEW CONSTRUCTION FOR THE OCCUPANCY. | | | | | | PLEASE PROVIDE DETAILS, CORRECT OR JUSTIFY WITH | | | SPECIFIC CODE REFERENCES AND NARRATIVE. | | | | | | ANY WORK ON THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS | | | SHALL BE DONE UNDER SEPARATE PERMITS AND SHOP DRAWINGS. | | | | | | PLEASE PROVIDE AN APPLICABLE NOTE OF ACKNOWLEDGEMENT. | | | | | | | | | ADDITIONAL COMMENT: | | | | | | 2A) PER NFPA 13 INSTALLATION OF FIRE SPRINKLERS | | | | | | CHAPTER 4 GENERAL REQUIREMENTS | | | 4.1 LEVEL OF PROTECTION. A BUILDING, WHERE PROTECTED BY | | | AN | | | AUTOMATIC SPRINKLER SYSTEM INSTALLATION, SHALL BE | | | PROVIDED WITH | | | SPRINKLERS IN ALL AREAS EXCEPT WHERE SPECIFIC SECTIONS | | | OF THIS | | | STANDARD PERMIT THE OMISSION OF SPRINKLERS. | | | | | | CHAPTER 8 INSTALLATION REQUIREMENTS | | | 8.1* BASIC REQUIREMENTS. | | | 8.1.1* THE REQUIREMENTS FOR SPACING, LOCATION, AND | | | POSITION OF | | | SPRINKLERS SHALL BE BASED ON THE FOLLOWING PRINCIPLES: | | | (1) SPRINKLERS SHALL BE INSTALLED THROUGHOUT THE | | | PREMISES. | | | | | | (4) SPRINKLERS SHALL BE PERMITTED TO BE OMITTED FROM | | | AREAS | | | SPECIFICALLY ALLOWED BY THIS STANDARD. | | | | | | THERE IS NO SPECIFIC OMMITTANCE FOR THE PROPOSED. | | | | | | | | | NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE | | | | | | CHAPTER 10 FUNDAMENTALS | | | 10.1 APPLICATION. | | | 10.1.1 THE BASIC FUNCTIONS OF A COMPLETE FIRE ALARM | | | AND/OR | | | SIGNALING SYSTEM SHALL COMPLY WITH THE REQUIREMENTS OF | | | THIS | | | CHAPTER. | | | | | | 10.2 PURPOSE. THE PURPOSE OF FIRE ALARM AND SIGNALING | | | SYSTEMS | | | SHALL BE PRIMARILY TO PROVIDE NOTIFICATION OF ALARM, | | | SUPERVISORY, | | | AND TROUBLE CONDITIONS; TO ALERT THE OCCUPANTS; TO | | | SUMMON | | | AID; AND TO CONTROL EMERGENCY CONTROL FUNCTIONS. | | | | | | THERE SHALL BE INITIATION AND NOTIFICATION IN THE NEW | | | PROPOSED AREA. | | | | | | | | | PLEASE REVIEW AND PROVIDE SPECIFIC ACKNOWLEDGEMENT TO | | | PROVIDE SPRINKLER AND ALARM SHOP DRAWING ON THE LIFE | | | SAFETY SHEET OR PROVIDE SPECIFIC CODE REFERENCES AND A | | | DETAILED NARRATIVE FOR OMMITTANCE. | | | | | | | | | | | | WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET REVISION | | | CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE ABOVE. | | | | | | | | | ADDITIONAL COMMENTS MAY BE PROVIDED ON THE RE-SUBMITTAL | | | OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2020-08-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-08-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-08-11 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2020-08-12 12:46:01 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SHEET A 1.0 - THERE ARE INDICATIONS OF EXISTING EXIT | | | DOORS LEADING OUT INTO THE NEW PATION; HOWEVER, THERE | | | ARE ONLY TWO EXIT DOORS FROM THE NEW PATIO. | | | | | | PER NFPA 101, CH 7 MEANS OF EGRESS | | | | | | 7.3.1 OCCUPANT LOAD. | | | 7.3.1.1 SUFFICIENT CAPACITY. | | | 7.3.1.1.1 THE TOTAL CAPACITY OF THE MEANS OF EGRESS FOR | | | ANY STORY, | | | BALCONY, TIER, OR OTHER OCCUPIED SPACE SHALL BE | | | SUFFICIENT FOR THE | | | OCCUPANT LOAD THEREOF | | | | | | 7.3.1.1.2 FOR OTHER THAN EXISTING MEANS OF EGRESS, | | | WHERE MORE | | | THAN ONE MEANS OF EGRESS IS REQUIRED, THE MEANS OF | | | EGRESS SHALL BE | | | OF SUCH WIDTH AND CAPACITY THAT THE LOSS OF ANY ONE | | | MEANS OF | | | EGRESS LEAVES AVAILABLE NOT LESS THAN 50 PERCENT OF THE | | | REQUIRED | | | CAPACITY. | | | | | | PLEASE PROVIDE A REVIEW OF THE EXISTING OCCUPANCY EGESS | | | LOADS AND NEW OCCUPANCY LOADS AND INDICATE THAT THAT | | | THESE TWO NEW PATIO DOORS PROVIDE THE REQUIRED EGRESS | | | WIDTH FROM THE EXISITNG BUILDING AS WELL AS THE | | | INCREASE OF THE NEW PATIO. | | | | | | | | | 1A) SHEET A 1.0 - THERE IS AN INDICATION OF A STAIRWAY | | | LEADING DOWN FROM A SINGLE PATIO DOOR. | | | | | | PER NFPA 101, CH 7 | | | | | | 7.3.3* EGRESS CAPACITY. | | | 7.3.3.1 EGRESS CAPACITY FOR APPROVED COMPONENTS OF | | | MEANS OF | | | EGRESS SHALL BE BASED ON THE CAPACITY FACTORS SHOWN IN | | | TABLE | | | 7.3.3.1, UNLESS OTHERWISE PROVIDED IN 7.3.3.2. | | | | | | PER THE SAME INFORMATION OF THE ABOVE COMMENT, PLEASE | | | PROVIDE DETAILS THAT THIS STAIRWAY MEETS THE EGRESS | | | REQUIREMENTS FOR THE COMBINED OCCUPANCY TOTALS. | | | | | | | | | | | | 2) THERE ARE NO INDICATIONS OF AN EXISTING FIRE | | | SPRINKLER OR FIRE ALARM SYSTEM. WITH THE CREATION OF | | | THIS NEW OCCUPIABLE INDOOR SPACE, THE LIFE SAFETY | | | SYSTEMS SHALL BE EXTENDED. | | | | | | PER NFPA 101, CH 4 | | | | | | 4.6.7 BUILDING REHABILITATION. | | | 4.6.7.1 REHABILITATION WORK ON EXISTING BUILDINGS SHALL | | | BE | | | CLASSIFIED AS ONE OF THE FOLLOWING WORK CATEGORIES IN | | | ACCORDANCE | | | WITH 43.2.2.1: | | | (1) REPAIR | | | (2) RENOVATION | | | (3) MODIFICATION | | | (4) RECONSTRUCTION | | | (5) CHANGE OF USE OR OCCUPANCY CLASSIFICATION | | | (6) ADDITION | | | | | | 43.8.3 FIRE PROTECTION SYSTEMS. IN OTHER THAN ONE- AND | | | TWOFAMILY | | | DWELLINGS, EXISTING COMPARTMENT AREAS WITHOUT AN | | | APPROVED SEPARATION FROM THE ADDITION SHALL BE | | | PROTECTED BY AN | | | APPROVED AUTOMATIC SPRINKLER SYSTEM WHERE THE COMBINED | | | AREAS | | | WOULD BE REQUIRED TO BE SPRINKLERED BY THE PROVISIONS | | | APPLICABLE | | | TO NEW CONSTRUCTION FOR THE OCCUPANCY. | | | | | | PLEASE PROVIDE DETAILS, CORRECT OR JUSTIFY WITH | | | SPECIFIC CODE REFERENCES AND NARRATIVE. | | | | | | ANY WORK ON THE FIRE SPRINKLER AND FIRE ALARM SYSTEMS | | | SHALL BE DONE UNDER SEPARATE PERMITS AND SHOP DRAWINGS. | | | | | | PLEASE PROVIDE AN APPLICABLE NOTE OF ACKNOWLEDGEMENT. | | | | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-01-07 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-01-07 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-12-21 |
Time |
11:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-12-21 |
|
|
Cont ID |
|
| Sent By |
ccarvaja |
Date |
2020-12-21 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
ccarvaja |
Date |
2020-12-07 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-10-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-07 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-25 |
Time |
14:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-09-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-16 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-10 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2020-12-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-12-30 |
Time |
07:17 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-12-30 |
Time |
07:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2020-12-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-12-11 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-12-10 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2020-12-11 08:17:12 | 3RD REVIEW FBC-2017 PLUMBING | | | PERMIT- 20071488 | | | 12/10/2020 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P2.1 REVISE THE STORM DRAINAGE CALCULATIONS | | | AND SQ. FT. ROOF AREA TO MATCH THE NEW CALCULATIONS | | | SUBMITTED BY H & M ARCHITECTURE. | | | | | | 2) THE REVISED A4.0 PLAN SHEET WAS NOT UPLOADED FOR | | | REVIEW. IT APPEARS THAT A2 WAS UPLOADED IN IT?S PLACE. | | | PLEASE PROVIDE THE PLAN SHEET- SECTION 107.2.1 WPB. | | | | | | 3) THE ARCHITECT?S NARRATIVE RESPONSE TO PREVIOUS | | | REVIEW COMMENT #1 INDICATES THERE IS NO ROOF SLOPE BUT | | | THE ROOF WILL DRAIN EFFICIENTLY, AND REFERENCE IS MADE | | | TO CANOPY SHOW DRAWINGS WHICH HAVE NOT BEEN PROVIDED. | | | THE SHOP DRAWINGS MAY BE A DEFERRED SUBMITTAL PER | | | SECTION 107.3.4.1 DEFERRED SUBMITTALS. | | | | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE | | | DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT | | | SUBMITTED AT THE TIME OF THE APPLICATION | | | AND THAT ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL | | | WITHIN A SPECIFIED PERIOD. DEFERRAL OF ANY | | | SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE | | | BUILDING OFFICIAL. THE REGISTERED DESIGN | | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE | | | DEFERRED SUBMITTALS ON THE CONSTRUCTION | | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN | | | PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW | | | THEM AND FORWARD THEM TO THE BUILDING | | | OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED | | | AND FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF | | | THE BUILDING. THE DEFERRED | | | SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE | | | DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE | | | BUILDING OFFICIAL. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2020-09-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-09-28 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-09-28 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2020-09-28 14:18:29 | 2ND REVIEW FBC-2017 PLUMBING | | | PERMIT- 20071488 | | | 9/28/2020 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | COMMENTS FROM THE 1ST REVIEW LISTED BELOW HAVE NOT BEEN | | | COMPLETELY ADDRESSED. ADDITIONAL COMMENT NOTES IN | | | CAPITOL LETTERS HAVE BEEN PROVIDED. | | | | | | 3) A4.0, P0, P2.1: ROOF DRAINAGE CALCULATIONS ARE | | | REQUIRED FOR THE NEW PATIO ROOF THAT INCLUDE THE | | | DRAINAGE FROM ADJACENT ROOFS OR PARTS OF THE BUILDING | | | THAT ARE DRAINING WATER ONTO THE ROOF. ROOF DRAINAGE | | | CALCULATIONS HAVE NOT BEEN PROVIDED. THE CALCULATIONS | | | ON THE NEW SHEET P2.1 APPEAR TO BE FOR THE TRENCH DRAIN | | | IN THE FLOOR SLAB WHICH IS ALSO LABELED AS A STORM | | | DRAIN. THERE IS NO ROOF SLOPE SHOWN ON THE DRAWINGS AND | | | THE ACTUAL LOCATIONS AND HEIGHTS OF PARAPET WALLS ALONG | | | THE ROOF PERIMETER IS NOT CLEAR. PLEASE EXPLAIN OR | | | CLARIFY THE STORM DRAINAGE CALCULATION ON THE P2.1. | | | FROM WHICH STANDARD IS THE EQUATION DERIVED FROM. | | | THE SHOP DRAWINGS AND/OR THE SITE-SPECIFIC PLANS SHALL | | | VERIFY THE ROOF HAS BEEN DESIGNED IN COMPLIANCE WITH | | | SECTION 1107.1 FBC P: ROOFS SHALL BE DESIGNED FOR THE | | | MAXIMUM POSSIBLE DEPTH OF WATER THAT WILL POND THEREON | | | AS DETERMINED BY THE RELATIVE LEVELS OF ROOF DECK AND | | | OVERFLOW WEIRS, SCUPPERS, EDGES OR SERVICEABLE DRAINS | | | IN COMBINATION WITH THE DEFLECTED STRUCTURAL ELEMENTS. | | | IN DETERMINING THE MAXIMUM POSSIBLE DEPTH OF WATER, ALL | | | PRIMARY ROOF DRAINAGE MEANS SHALL BE ASSUMED TO BE | | | BLOCKED. THE MAXIMUM POSSIBLE DEPTH OF WATER ON THE | | | ROOF SHALL INCLUDE THE HEIGHT OF THE WATER REQUIRED | | | ABOVE THE INLET OF THE SECONDARY ROOF DRAINAGE MEANS TO | | | ACHIEVE THE REQUIRED FLOW RATE OF THE SECONDARY | | | DRAINAGE MEANS TO ACCOMMODATE THE DESIGN RAINFALL RATE | | | AS REQUIRED BY SECTION 1106. SHOP DRAWINGS NOT | | | PROVIDED. NO ROOF SLOPE INDICATED. | | | | | | A) CALCULATIONS SHALL ALSO BE PROVIDED FOR THE VERTICAL | | | DOWNSPOUTS- SECTION 1106.1 AND THE HORIZONTAL GUTTERS- | | | SECTION 1106.6 AND TABLE 1106.6. ROOF DRAINAGE | | | CALCULATIONS AND SIZES OF THE GUTTERS AND DOWNSPOUTS | | | NOT PROVIDED. | | | | | | 4) A4.0, P0, P2.1: VERIFY THE STORM WATER FROM THE ROOF | | | AND THE TRENCH DRAIN WILL FLOW AWAY FROM THE BUILDING | | | AND DRAIN INTO APPROVED PERMEABLE AREA THAT WILL NOT | | | POND OR FLOOD, OTHERWISE CONNECT THE DRAINS TO THE | | | EXISTING STORM DRAINAGE SYSTEM ON SITE- SECTION | | | 1101.2.NO NOTES OR DRAINAGE SLOPE PROVIDED TO VERIFY | | | COMPLIANCE. | | | | | | 5) SHEET A4.0: THE DOWNSPOUT NOTE NEEDS TO BE MODIFIED | | | TO INDICATE "TYP" FOR THE LOCATIONS AT THE COLUMNS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-08-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-08-24 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-08-24 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2020-08-24 11:55:06 | 1ST REVIEW FBC-2017 PLUMBING | | | PERMIT- 20071488 | | | 8/24/2020 | | | | | | CODES IN EFFECT: | | | | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A1.0: A SEPARATE PERMIT AND PLAN SUBMITTAL ARE | | | REQUIRED FOR THE IRRIGATION WORK THAT IS NOTED ON THE | | | DEMOLITION PLAN- SECTION 107.2.1 WPB. | | | | | | 2) A4.0, P0, P2.1: SUBMIT THE ENGINEERED SHOP DRAWINGS | | | FOR THE PATIO WITH APPROVAL STAMPS BY THE DESIGN | | | PROFESSIONALS OF RECORD- SECTIONS 105.3 & 107.2.1 WPB. | | | | | | 3) A4.0, P0, P2.1: ROOF DRAINAGE CALCULATIONS ARE | | | REQUIRED FOR THE NEW PATIO ROOF THAT INCLUDE THE | | | DRAINAGE FROM ADJACENT ROOFS OR PARTS OF THE BUILDING | | | THAT ARE DRAINING WATER ONTO THE ROOF. | | | THE SHOP DRAWINGS AND/OR THE SITE-SPECIFIC PLANS SHALL | | | VERIFY THE ROOF HAS BEEN DESIGNED IN COMPLIANCE WITH | | | SECTION 1107.1 FBC P: ROOFS SHALL BE DESIGNED FOR THE | | | MAXIMUM POSSIBLE DEPTH OF WATER THAT WILL POND THEREON | | | AS DETERMINED BY THE RELATIVE LEVELS OF ROOF DECK AND | | | OVERFLOW WEIRS, SCUPPERS, EDGES OR SERVICEABLE DRAINS | | | IN COMBINATION WITH THE DEFLECTED STRUCTURAL ELEMENTS. | | | IN DETERMINING THE MAXIMUM POSSIBLE DEPTH OF WATER, ALL | | | PRIMARY ROOF DRAINAGE MEANS SHALL BE ASSUMED TO BE | | | BLOCKED. THE MAXIMUM POSSIBLE DEPTH OF WATER ON THE | | | ROOF SHALL INCLUDE THE HEIGHT OF THE WATER REQUIRED | | | ABOVE THE INLET OF THE SECONDARY ROOF DRAINAGE MEANS TO | | | ACHIEVE THE REQUIRED FLOW RATE OF THE SECONDARY | | | DRAINAGE MEANS TO ACCOMMODATE THE DESIGN RAINFALL RATE | | | AS REQUIRED BY SECTION 1106. | | | A) CALCULATIONS SHALL ALSO BE PROVIDED FOR THE VERTICAL | | | DOWNSPOUTS- SECTION 1106.1 AND THE HORIZONTAL GUTTERS- | | | SECTION 1106.6 AND TABLE 1106.6. | | | | | | 4) A4.0, P0, P2.1: VERIFY THE STORM WATER FROM THE ROOF | | | AND THE TRENCH DRAIN WILL FLOW AWAY FROM THE BUILDING | | | AND DRAIN INTO APPROVED PERMEABLE AREA THAT WILL NOT | | | POND OR FLOOD, OTHERWISE CONNECT THE DRAINS TO THE | | | EXISTING STORM DRAINAGE SYSTEM ON SITE- SECTION 1101.2. | | | | | | 5)SHEET P2.1: THE DIMENSIONS OF THE STORM DRAIN ARE NOT | | | SHOWN. THE VERTICAL LEADER CALCULATIONS INDICATE THE | | | SCREEN AREA ONLY AND NONE OF THE FLOOR AREA THAT WILL | | | BE COLLECTING RAIN WATER. PLEASE REVISE THE | | | CALCULATIONS AND SUBMIT SPECS FOR THE TRENCH DRAIN- | | | SECTION 412.1 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2020-12-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-12-28 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-12-28 |
Time |
08:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-12-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-12-14 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-12-14 |
Time |
08:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-10-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-07 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-07 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-09-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-16 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-16 |
Time |
12:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2021-01-07 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2021-01-07 |
Time |
17:20 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2021-01-07 |
Time |
16:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2020-12-21 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-12-21 |
Time |
14:56 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2020-12-21 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2020-12-21 14:56:03 | FAILED | | | | | | THE PERMIT SET HAS SHEET A2 UPLOADED TWICE, ONCE TO | | | REPLACE THE OLDER VERSION OF THIS SHEET AND ONCE | | | REPLACING SHEET A4 (WITH ACTUALLY AN OLDER VERSION OF | | | SHEET A2). WHILE ZONING HAD ORIGINALLY PASSED THE | | | PLANS, THE DUPLICATE VERSION OF A2 AND NO VERSION OF A4 | | | DO NOT PERMIT ZONING TO PASS THIS RESUBMITTAL. PLEASE | | | ENSURE THE CORRECT PLANS ARE UPLOADED. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-10-05 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-10-05 |
Time |
17:25 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2020-10-05 |
Time |
17:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-09-11 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-09-11 |
Time |
11:49 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2020-09-11 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|