| Plan Review Stops For Permit 20071364 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-09-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-03 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-03 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2020-09-03 14:41:15 | PLAN REVIEW - BUILDING GENERATOR | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | 1ST REVIEW COMMENTS: | | | | | | 1. CORRECTED. | | | | | | 2. FBC 107, PROVIDE A SURVEY SHOWING PROPOSED LOCATION | | | OF THE GENERATOR. (SURVEY SUBMITTED DOES NOT SHOW | | | LOCATION OF GENERATOR. SITE PLAN SUBMITTED SHOWS | | | LOCATION OF GENERATOR PAD WITH 4 GENERATORS. NO | | | DEMENSIONS TO PROPERTY LINES PROVIDE). | | | | | | NEW COMMENTS: | | | | | | 3. 1. CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. | | | | | | 3.1A. THE STATED VALUE APPEARS LOW FOR THE PROPOSED | | | SCOPE OF WORK. | | | 3.1B. THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. THIS INCLUDES ALL LABOR, | | | MATERIALS AND RENTALS OF EQUIPMENT TO PERFORM THE SCOPE | | | OF WORK. | | | 3.1C. YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY | | | THE OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | 3.1D. FINAL BUILDING PERMIT VALUATION SHALL BE SET BY | | | THE BUILDING OFFICIAL. | | | PLEASE INCREASE THE VALUATION ACCORDINGLY. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-08-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-08-21 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-08-21 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2020-08-21 08:44:40 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC R 301, PROVIDE A STRUCTURAL DETAIL FOR THE | | | GENERATOR PAD AND ANCHORING. IF A FORMED AND POURED | | | SLAB IS PROPOSED, THE DESIGN IS TO INCLUDE THE PRINTED | | | NAME AND SIGNATURE OF THE INDIVIDUAL TAKING | | | RESPONSIBILITY FOR THE DESIGN. | | | | | | IF A PREFAB SLAB IS PROPOSED, ENGINEERING IS REQUIRED. | | | | | | 2. FBC 107, PROVIDE A SURVEY SHOWING PROPOSED LOCATION | | | OF THE GENERATOR. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-09-08 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-09-08 |
Time |
21:41 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-09-07 |
Time |
22:32 |
Sent To |
|
|
| Notes |
| 2020-09-08 21:41:05 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. DRAWINGS OVER 250V TO GROUND MUST BE DESIGNED BY AN | | | ENGINEER. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-08-19 |
Time |
19:31 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-08-17 |
Time |
22:01 |
Sent To |
|
|
| Notes |
| 2020-08-19 19:31:17 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. SHOW AMOUNT OF 600MCM SOOW FEEDERS, PLAN ONLY SAYS | | | "600MCM SO CORD". FBC 107.2.1 NEC 215 | | | | | | 2. HOW LONG IS TEMP GENERATOR TO BE USED FOR? PLEASE | | | SUBMIT TIMELINE/SCHEDULE FOR APPROVAL. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2020-09-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-09-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-09-04 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2020-09-04 11:06:00 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE ARE NO INDICATIONS OF THE LOCATION OF THE | | | TEMPORARY GENERATOR ON THE SITE PLAN. | | | | | | PLEASE PROVIDE A LOCATION WITH DIMENSION TO BUILDING | | | AND INCLUDE SPARATION DISTANCE FROM ANY WINDOWS, DOORS | | | OR A/C EQUIPMENT. | | | | | | | | | 1A) IF IT IS PROPOSED IN THE PARKING LOT, PROVIDE | | | PROTECTION FROM UNINTENDED VEHICLE IMPACT OR JUSTIFY | | | WITH SPECIFIC NARRATIVE WHY PROTECTION WOULD NOT BE | | | NEEDED. | | | | | | | | | | | | 2) PLEASE PROVIDE ANY MANUFACTURES SPECIFICATION SHEETS | | | THAT INCLUDE FUEL TYPE, MOBILE/WHEELED OR STATIONARY. | | | | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
F |
Date |
2020-09-08 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-09-08 |
Time |
21:41 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-08-25 |
Time |
14:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-08-25 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-08-25 |
Time |
06:58 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-07-28 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-09-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-03 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-03 |
Time |
13:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-08-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-08-21 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-08-21 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2020-08-21 08:45:10 | NOT CLEAR IF ENGINEERING WILL BE REQUIRED; SEE BUILDING | | | REVIEW | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2020-09-04 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-09-04 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2020-09-04 |
Time |
17:16 |
Sent To |
I |
|
| Notes |
| 2020-09-04 17:43:13 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 9/4/20 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. INDICATE SETBACK DIMENSIONS FROM PROPOSED GENERATOR | | | EQUIPMENT TO ALL PROPERTY LINES. PURSUANT TO THE CITY | | | OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDR), SECTION 94-305(B)(4): MECHANICAL | | | EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET INTO A | | | REQUIRED SETBACK. | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1442 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-08-23 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-08-23 |
Time |
20:44 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2020-08-21 |
Time |
20:39 |
Sent To |
I |
|
| Notes |
| 2020-08-23 20:48:11 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 8/21/20 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1.PROVIDE A CURRENT SURVEY, WHICH INCLUDES THE | | | PROPERTY'S ADDRESS AND LEGAL DESCRIPTION. PLEASE | | | ILLUSTRATE THE FOLLOWING ON THE SURVEY: | | | - LOCATION OF PROPOSED GENERATOR EQUIPMENT | | | - DISTANCE FROM GENERATOR TO PROPERTY LINE | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1442 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|