Plan Review Details - Permit 20071339
| Plan Review Stops For Permit 20071339 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-19 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-19 |
Time |
08:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-08-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-08-18 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-08-18 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-08-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-08-18 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-08-18 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2020-08-18 10:43:41 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | 1) A PLAN SHOWING THE REQUIRED LABELS SHALL BE | | | PROVIDED. | | | | | | 690.31(G)(3) MARKING AND LABELING REQUIRED. | | | 690.31(G)(4) MARKING AND LABELING METHODS AND | | | LOCATIONS. | | | | | | | | | 2) NEUTRAL CONDUCTOR CAN NOT BE BONDED TO THE ENCLOSURE | | | IN THE COMBINER PANEL. 250.24 (A)(5) LOAD-SIDE | | | GROUNDING CONNECTIONS. A GROUNDED CONDUCTOR SHALL NOT | | | BE CONNECTED TO NORMALLY NON?CURRENTCARRYING METAL | | | PARTS OF EQUIPMENT, TO EQUIPMENT GROUNDING | | | CONDUCTOR(S), OR BE RECONNECTED TO GROU ND ON THE LOAD | | | SIDE OF THE SERVICE DISCONNECTING MEANS EXCEPT AS | | | OTHERWISE PERMITTED IN THIS ARTICLE. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-19 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-28 |
Time |
14:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2020-08-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-08-12 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-08-12 |
Time |
09:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-08-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-08-12 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-08-12 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2020-08-12 10:02:27 | PLEASE DISREGARD FOLLOWING NOTE. SIGNATURE APPROVED. | | 2020-08-12 09:48:40 | ENGINEERS MUST HAVE THIRD PARTY VERIFICATION. | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | IS REQUIRED TO BE SIGNED AND SEALED BY THE PERSON | | | RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A | | | DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY | | | VERIFICATION. PROVIDE CORRECTION. ALTERNATIVELY, A | | | SIGNED/SEALED PAPER SET MAY BE SUPPLIED TO THE BUILDING | | | DEPARTMENT WHEN ALL TRADES ARE APPROVED. WPB FBC 107.1; | | | FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-08-07 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-08-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2020-08-07 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-08-05 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2020-08-05 |
Time |
|
Sent To |
I |
|
| Notes |
| 2020-08-05 12:13:50 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 8/5/2020 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PLEASE PROVIDE A MARKED SURVEY OF THE PROPOERTY | | | INDICATING THE SCOPE OF WORK. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | IF THE FORM IS TEMPORARILY UNAVAILABLE, PLEASE REQUEST | | | THAT IT BE SENT TO YOU BY EMAILING [email protected] | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | TTY: 800.955.8771 | | | E: [email protected] | | | W: WPB.ORG | | | |
|
|
|