Plan Review Details - Permit 20071273
| Plan Review Stops For Permit 20071273 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-08-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-20 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-20 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-08-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-08-10 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-08-10 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2020-08-10 09:52:08 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE SCOPE OF WORK SHOWN ON YOUR DRAWING IS A LEVEL 2 | | | ALTERATION PER FBC EXISTING BUILDING. PLEASE NOTE THIS | | | ON THE PLANS. | | | | | | 2) PROVIDE DETAILS/WALL SECTION FOR THE KITCHEN WINDOW | | | INFILL. SPECIFY THE DIMENSIONS OF THE ROUGH OPENING. | | | SHOW ALL CONSTRUCTION MATERIALS AND INSULATION. SPECIFY | | | THE WIND LOAD DATA ON THE PLANS. WINDSPEED AND EXPOSURE | | | CATEGORY. FBC 107.2.1 | | | | | | 3) PROVIDE INTERIOR WALL FRAMING AND FINISH DETAILS. | | | FBC 107.2.1 | | | | | | 4) SUBMIT AN EXISTING FLOOR PLAN FOR THIS PROJECT. FBC | | | 107.2.1 | | | | | | 5) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | 6) IT APPEARS THAT THE KITCHEN CABINETS ARE BEING | | | RECONFIGURED OR MORE CABINETS ARE BEING ADDED. | | | ADDITIONAL COUNTER TOP SPACE MAY REQUIRE ADDITIONAL | | | RECEPTACLES AND AN ELECTRICAL PERMIT AND ELECTRICAL | | | PLANS. | | | | | | 7) TO AVOID ADDITIONAL REVIEW COMMENTS AND PROVIDE | | | CLARIFICATION, IT MAY BE HELPFUL TO PROVIDE A NARRATIVE | | | LETTER EXPLAINING HOW EACH COMMENT HAS BEEN ADDRESSED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-08-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-20 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-20 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-08-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-20 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-11 |
Time |
09:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-08-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-08-10 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-29 |
Time |
16:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-08-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-20 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-20 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-08-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-08-10 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-08-10 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2020-08-10 13:30:38 | PLANS WERE NOT SIGNED BY PERSON RESPONSIBLE FOR THE | | | DRAWINGS. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |