| Plan Review Stops For Permit 20071263 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-09-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-14 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-14 |
Time |
12:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-19 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-19 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2020-08-19 11:31:11 | RENOVATION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVAL FOR THE ROOFING SYSTEMS TO BE USED. IN | | | THE PRODUCT APPROVAL FOR THE FLAT DECK - PLEASE CIRCLE | | | THE ROOFING SYSTEM TO BE USED IN THE ROOFING PRODUCT | | | APPROVAL - ROOFING SYSTEM TO BE USED ON THE PROVIDED | | | PRODUCT APPROVAL MAY REQUIRE ADDITIONAL SIGNED AND | | | SEALED ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER | | | FOR ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER | | | PRESSURE THAN THE MAXIMUM SHOWN ON THE PRODUCT | | | APPROVAL. PLEASE CIRCLE ROOF TILE ATTACHMENT TO BE USED | | | ON THE ROOFING TILE PRODUCT APPROVAL. PLEASE PROVIDE | | | ANY ADDITIONAL PRODUCT APPROVAL REQUIRED - SUCH AS | | | ADHESIVE FOR THE ATTACHMENT OF THE ROOF TILE. | | | 2) ON THE SITE PLAN - PLEASE SHOW THE SHED TO BE ON A | | | SEPARATE PERMIT OR REMOVE IT FROM THE PLANS. | | | 3) WINDOWS AND DOORS ARE ON PERMIT 20050988 PLEASE SHOW | | | THIS ON THE DRAWINGS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-08-13 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-08-13 |
Time |
21:28 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-08-13 |
Time |
20:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-09-04 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-09-04 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-09-04 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2020-09-04 10:16:32 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR | | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC | | | SEC. 105.1. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-09-11 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-09-11 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-09-11 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2020-09-11 10:29:40 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | | CONDITION(S): | | | 1. SEPARATE PERMIT REQUIRED FOR FENCE/WALL, AWNINGS, | | | SIGNS, PARKING LOT, GENERATOR, MECHANICAL/AC/POOL | | | EQUIPMENT, DUMPSTER ENCLOSURE, IRRIGATION, LANDSCAPE, | | | OTHER _____________ | | | 2. A ?NEW MANSARD ROOF? ON THE FRONT ELEVATION SHALL | | | NOT BE INSTALLED. | | | | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-08-05 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-08-05 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2020-08-05 15:30:04 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | | | 1. A SEPARATE PERMIT IS NEEDED FOR THE FOLLOWING: EACH | | | PERMIT SHOULD HAVE A SITE PLAN. THE EXISTING DRIVEWAY | | | PLAN (DW-1) IS ACCEPTABLE IF EACH ITEM IS HIGHLIGHTED | | | OR EMPHASIZED: | | | A. FENCE PERMIT - FENCE, GATE AND ROLLING GATE. PROVIDE | | | MATERIAL SLIDING DRIVEWAY. A GRAPHIC WILL BE | | | BENEFICIAL. | | | B. LANDSCAPING PERMIT - ASTRO TURF REQUIRES A | | | LANDSCAPING PERMIT. IT MUST NOT BE VISIBLE FROM ANY | | | ROAD AND MUST NOT BE WITHIN THE FRONT YARD AREA, WHICH | | | IS THE FIRST 25 FEET OF THE PROPERTY ON SPRUCE. ALL | | | OTHER PROPERTY LINES REQUIRE A 2-FOOT SETBACK FROM THE | | | PROPERTY LINE. PLEASE INCLUDE WHAT THE EXISTING SURFACE | | | IS. | | | C. BUILDING PERMIT - A SEPARATE BUILDING PERMIT IS | | | NEEDED FOR THE 1-STORY GARAGE CONVERTED TO A GUEST | | | HOUSE. PROVIDE A FLOOR PLAN. | | | | | | 2. WINDOW AND DOOR REPLACEMENT HAS ALREADY BEEN | | | APPROVED ON A SEPARATE PERMIT. THE INCLUDED WINDOW | | | INFORMATION IS INCORRECT. REMOVE ALL REFERENCES TO | | | WINDOW AND DOOR REPLACEMENT. | | | 3. EXPAND THE EXISTING PROJECT DATA TABLE. CALCULATIONS | | | SHOULD BE DONE PER SEC. 94-86 - HTTP://ONLINE.ENCODEPLU | | | S.COM/REGS/WESTPALMBEACH-FL/DOC-VIEWER.ASPX#SECID-271 | | | 4. PROVIDE ROOFING PRODUCT APPROVALS. | | | 5. REMOVE ?NEW MANSARD ROOF? FOR FRONT ENTRY ON | | | PROPOSED FIRST STORY FLOOR PLAN. STAFF WILL NOT SUPPORT | | | THIS. | | | 6. PROVIDE CLARIFICATION ON ROOF OVERHANG AND ENSURE | | | FLOOR PLANS AND ELEVATIONS ARE CONSISTENT. | | | 7. PROVIDE DETAILS REGARDING STORAGE SHED INCLUDING | | | ELEVATION OR GRAPHIC. THE SHED IS REQUIRED TO HAVE A | | | FIVE-FOOT REAR AND SIDE YARD SETBACK. A SIX-FOOT | | | BUILDING SEPARATE IS ALSO REQUIRED. | | | 8. EXPAND THE SCOPE OF WORK TO INCLUDE EXTERIOR WORK TO | | | STRUCTURE AND SITE. | | | 9. REVISE, HIGHLIGHT, OR EMPHASIZED THE SITE PLAN | | | (DRIVEWAY PLAN) TO ILLUSTRATE THE WORK BEING DONE FOR | | | THIS PERMIT. | | | 10. ILLUSTRATE THREE PARKING SPACES PER SEC. 94-485, | | | FIGURE XV-2. - HTTP://ONLINE.ENCODEPLUS.COM/REGS/WESTPA | | | LMBEACH-FL/DOC-VIEWER.ASPX#SECID-719 | | | 11. ALL NEW IMPREVOIUS SURFACES REQUIRE A 2-FOOT | | | SETBACK FROM THE PROPERTY LINE. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-09-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-14 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-03 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-19 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-30 |
Time |
09:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-09-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-04 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-04 |
Time |
08:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-08-05 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-08-05 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2020-08-05 12:02:32 | PROVIDE DETAILS FOR THE NEW WOLF RANGE AND THE NEW | | | HOOD. PLEASE SPECIFY THE CFM'S OF NEW HOOD REQUIRED BY | | | THE NEW WOLF RANGE. PLEASE PROVIDE A MECHANICAL SHEET | | | SHOWING THE HOOD DUCT WORK DETAIL AND THE TERMINATION | | | POINT OF THE HOOD. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-09-04 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-09-04 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-09-04 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2020-09-04 11:32:36 | 09/04/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-08-05 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-08-05 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2020-08-05 15:06:26 | 1ST REVIEW FBC-2017 RES. | | | PERMIT 20071263 | | | 8/5/2020 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 03: THE PLAN SHOWS A NEW ISLAND SINK AND | | | DISHWASHER, AND WATER CLOSET RELOCATION IN THE POWDER | | | ROOM. PLEASE PROVIDE PLUMBING PLANS INCLUDING SANITARY | | | AND WATER DISTRIBUTION RISERS- SECTIONS 107.3.5.3 AND | | | 107.2.1 WPB. REFER TO SECTION P3112 FBC RES. CONCERNING | | | ISLAND FIXTURE VENTING. | | | | | | 2) SHEET 03 INDICATES NEW GAS APPLIANCES TO BE | | | INSTALLED AND GAS PIPING INSTALLATION- PLEASE NOTE THAT | | | COMPLETE PLANS INCLUDING A GAS RISER AND PRODUCT | | | SPECIFICATIONS SHALL BE SUBMITTED UNDER A SEPARATE | | | PRIMARY PERMIT. | | | | | | 3) SHEET 04: THE SCOPE OF WORK FOR PLUMBING IS NOT | | | PROVIDED, AND NO DIMENSIONS PROVIDED FOR THE NEW STEAM | | | SHOWER- SECTION P2708.1 FBC RES. AND SECTION 107.2.1 | | | WPB. | | | | | | 4) PROVIDE A SHOWER PAN DETAIL- SECTION P2709.1 & | | | P2709.2 FBC RES. | | | | | | 5) PLEASE SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | | STEAM SHOWER UNIT. PLEASE NOTE THE UNIT SHALL BE | | | INSTALLED IN ACCORDANCE WITH MANUFACTURER?S | | | SPECIFICATIONS AND GUIDELINES, AND THE SHOWER VALVE | | | SHALL BE IN COMPLIANCE WITH SECTION P2708.4. THE WATER | | | SUPPLY TO THE UNIT WILL REQUIRE A BACKFLOW PREVENTER | | | PER SECTION P2902.1. SHOW THE LOCATION OF THE DEVICE | | | AND INDICATE THE MAKE AND MODEL TO BE INSTALLED- TABLE | | | 2902.3. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2020-09-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-14 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-14 |
Time |
12:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-19 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-19 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2020-08-19 12:08:15 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-09-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-14 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-14 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-09-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-04 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-04 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2020-09-04 10:21:28 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20071263 | | | | | | CODES IN EFFECT: | | | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M-1 ALL FINAL CONSTRUCTION DOCUMENTS AND | | | INSTRUMENTS OF SERVICE WHICH INCLUDE DRAWINGS, PLANS, | | | SPECIFICATIONS, OR REPORTS PREPARED OR ISSUED BY THE | | | REGISTERED ARCHITECT AND BEING FILED FOR PUBLIC RECORD | | | SHALL BEAR THE SIGNATURE AND SEAL OF THE REGISTERED | | | ARCHITECT WHO PREPARED OR APPROVED THE DOCUMENT AND THE | | | DATE ON WHICH THEY WERE SEALED. THE SIGNATURE, DATE, | | | AND SEAL SHALL BE EVIDENCE OF THE AUTHENTICITY OF THAT | | | TO WHICH THEY ARE AFFIXED. FINAL PLANS, SPECIFICATIONS, | | | OR REPORTS PREPARED OR ISSUED BY A REGISTERED ARCHITECT | | | MAY BE TRANSMITTED ELECTRONICALLY AND MAY BE SIGNED BY | | | THE REGISTERED ARCHITECT, DATED, AND SEALED | | | ELECTRONICALLY WITH THE SEAL IN ACCORDANCE WITH SS. | | | 668.001-668.006. | | | | | | 2) SHEETS DW-1 AND DW-2: WILL NEED 3RD PARTY | | | VALIDATION. PER THE WPB AMENDMENTS TO THE FBC, EACH | | | SHEET OF PLAN IS REQUIRED TO BE SIGNED AND SEALED BY | | | THE PERSON RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN | | | REQUIRES A DIGITAL SIGNATURE WITH THE PROPER THIRD | | | PARTY VERIFICATION. PROVIDE CORRECTION. ALTERNATIVELY, | | | A SIGNED/SEALED PAPER SET MAY BE SUPPLIED TO THE | | | BUILDING DEPARTMENT WHEN ALL TRADES ARE APPROVED. WPB | | | FBC 107.1; FS 471/481 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-08-05 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-08-05 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-09-11 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-09-11 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-09-11 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2020-09-11 10:30:03 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | | CONDITION(S): | | | 1. SEPARATE PERMIT REQUIRED FOR FENCE/WALL, AWNINGS, | | | SIGNS, PARKING LOT, GENERATOR, MECHANICAL/AC/POOL | | | EQUIPMENT, DUMPSTER ENCLOSURE, IRRIGATION, LANDSCAPE, | | | OTHER _____________ | | | 2. A ?NEW MANSARD ROOF? ON THE FRONT ELEVATION SHALL | | | NOT BE INSTALLED. | | | | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-08-05 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-08-05 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2020-08-05 15:29:50 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | | | 1. A SEPARATE PERMIT IS NEEDED FOR THE FOLLOWING: EACH | | | PERMIT SHOULD HAVE A SITE PLAN. THE EXISTING DRIVEWAY | | | PLAN (DW-1) IS ACCEPTABLE IF EACH ITEM IS HIGHLIGHTED | | | OR EMPHASIZED: | | | A. FENCE PERMIT - FENCE, GATE AND ROLLING GATE. PROVIDE | | | MATERIAL SLIDING DRIVEWAY. A GRAPHIC WILL BE | | | BENEFICIAL. | | | B. LANDSCAPING PERMIT - ASTRO TURF REQUIRES A | | | LANDSCAPING PERMIT. IT MUST NOT BE VISIBLE FROM ANY | | | ROAD AND MUST NOT BE WITHIN THE FRONT YARD AREA, WHICH | | | IS THE FIRST 25 FEET OF THE PROPERTY ON SPRUCE. ALL | | | OTHER PROPERTY LINES REQUIRE A 2-FOOT SETBACK FROM THE | | | PROPERTY LINE. PLEASE INCLUDE WHAT THE EXISTING SURFACE | | | IS. | | | C. BUILDING PERMIT - A SEPARATE BUILDING PERMIT IS | | | NEEDED FOR THE 1-STORY GARAGE CONVERTED TO A GUEST | | | HOUSE. PROVIDE A FLOOR PLAN. | | | | | | 2. WINDOW AND DOOR REPLACEMENT HAS ALREADY BEEN | | | APPROVED ON A SEPARATE PERMIT. THE INCLUDED WINDOW | | | INFORMATION IS INCORRECT. REMOVE ALL REFERENCES TO | | | WINDOW AND DOOR REPLACEMENT. | | | 3. EXPAND THE EXISTING PROJECT DATA TABLE. CALCULATIONS | | | SHOULD BE DONE PER SEC. 94-86 - HTTP://ONLINE.ENCODEPLU | | | S.COM/REGS/WESTPALMBEACH-FL/DOC-VIEWER.ASPX#SECID-271 | | | 4. PROVIDE ROOFING PRODUCT APPROVALS. | | | 5. REMOVE ?NEW MANSARD ROOF? FOR FRONT ENTRY ON | | | PROPOSED FIRST STORY FLOOR PLAN. STAFF WILL NOT SUPPORT | | | THIS. | | | 6. PROVIDE CLARIFICATION ON ROOF OVERHANG AND ENSURE | | | FLOOR PLANS AND ELEVATIONS ARE CONSISTENT. | | | 7. PROVIDE DETAILS REGARDING STORAGE SHED INCLUDING | | | ELEVATION OR GRAPHIC. THE SHED IS REQUIRED TO HAVE A | | | FIVE-FOOT REAR AND SIDE YARD SETBACK. A SIX-FOOT | | | BUILDING SEPARATE IS ALSO REQUIRED. | | | 8. EXPAND THE SCOPE OF WORK TO INCLUDE EXTERIOR WORK TO | | | STRUCTURE AND SITE. | | | 9. REVISE, HIGHLIGHT, OR EMPHASIZED THE SITE PLAN | | | (DRIVEWAY PLAN) TO ILLUSTRATE THE WORK BEING DONE FOR | | | THIS PERMIT. | | | 10. ILLUSTRATE THREE PARKING SPACES PER SEC. 94-485, | | | FIGURE XV-2. - HTTP://ONLINE.ENCODEPLUS.COM/REGS/WESTPA | | | LMBEACH-FL/DOC-VIEWER.ASPX#SECID-719 | | | 11. ALL NEW IMPREVOIUS SURFACES REQUIRE A 2-FOOT | | | SETBACK FROM THE PROPERTY LINE. | | | | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|