Plan Review Details - Permit 20071196
Plan Review Stops For Permit 20071196
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-08-21 Cont ID  
Sent By shill Date 2020-08-21 Time 16:04 Rev Time 0.00
Received By shill Date 2020-08-21 Time 15:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-15 Cont ID  
Sent By cthroop Date 2020-08-15 Time 12:03 Rev Time 0.00
Received By cthroop Date 2020-08-15 Time 11:22 Sent To  
Notes
2020-08-15 12:19:29PLAN REVIEW GENERATOR - BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 GENERATOR PAD AND DESIGN WIND LOAD CALC'S
  
 1. THE SITE SPECIFIC DESIGN WIND LOAD CALC'S PROVIDED
 FOR REVIEW ARE BASED ON VULT OF 185MPH AND VASD OF
 144MPH WITH A RISK CATEGORY OF III AND AN EXPOSURE
 CATEGORY OF D. BASED ON THE TABLE PROVIDED THIS
 ESTABLISHES THE DESIGN WIND LOADS TO BE 53.19PSF FOR
 PALM BEACH COUNTY.
 2. THE ALLOWABLE DESIGN PRESSURE OF THE GENERATOR PAD
 SUBMITTED IS ONLY 47.44PSF. THIS PAD IS NOT ALLOWED FOR
 DESIGN WIND LOADS OF 53.19PSF.
 3. PLEASE SUBMIT SITE SPECIFIC DESIGN WIND LOAD CALC'S
 BASED ON PALM BEACH COUNTY'S DESIGN PARAMETERS OF VULT
 OF 170MPH, (FIGURE R301.2(4) ) VASD OF 132MPH (TABLE
 R301.2.1.3) RISK CATEGORY I AND EXPOSURE CATEGORY C OR
 PROVIDE A CONCRETE PAD THAT MEETS OR EXCEEDS THE DESIGN
 WIND LOADS PROVIDED.
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-08-15 Cont ID  
Sent By cthroop Date 2020-08-15 Time 11:52 Rev Time 0.00
Received By cthroop Date 2020-08-15 Time 11:22 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-08-26 Cont ID  
Sent By lcrespo Date 2020-08-26 Time 11:52 Rev Time 0.00
Received By lcrespo Date 2020-08-26 Time 11:27 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2020-08-05 Cont ID  
Sent By lcrespo Date 2020-08-05 Time 08:00 Rev Time 0.00
Received By lcrespo Date 2020-08-05 Time 08:00 Sent To  
Notes
2020-08-05 08:01:54GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN
 PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS
 WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 A SUB PLUMBING LP CONTRACTOR PERMIT IS REQUIRED BY A
 LICENSED CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB
 AMENDMENTS TO THE FBC SEC. 105.1.
  
 THE SPECIFICATION SUBMITTED FORM GENERAC NEED TO BE
 UPDATED TO THE LATEST VERSION PLEASE SEE THE LINK; HTTP
 S://WWW.GENERAC.COM/GENERACCORPORATE/MEDIA/LIBRARY/CONT
 ENT/ALL-PRODUCTS/GENERATORS/HOME-GENERATORS/GUARDIAN-SE
 RIES/16KW-7036/20-AND-22KW-SPEC-SHEET-GENERAC-NEW_3.PDF
 .
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-09-17 Cont ID  
Sent By jgomez Date 2020-09-17 Time 14:06 Rev Time 0.00
Received By jgomez Date 2020-09-17 Time 06:16 Sent To I
Notes
2020-09-17 06:16:53RECEIVED DOCUMENTS FOR SIGNATURE ROUTED TO "S4"

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-31 Cont ID  
Sent By ccarvaja Date 2020-08-28 Time 09:03 Rev Time 0.00
Received By ccarvaja Date 2020-08-19 Time 15:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-19 Cont ID  
Sent By ccarvaja Date 2020-08-18 Time 08:43 Rev Time 0.00
Received By ccarvaja Date 2020-07-24 Time 16:08 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-08-26 Cont ID  
Sent By lcrespo Date 2020-08-26 Time 11:52 Rev Time 0.00
Received By lcrespo Date 2020-08-26 Time 11:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-08-05 Cont ID  
Sent By lcrespo Date 2020-08-05 Time 08:02 Rev Time 0.00
Received By lcrespo Date 2020-08-05 Time 08:02 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-09-17 Cont ID  
Sent By jgomez Date 2020-09-17 Time 14:05 Rev Time 0.00
Received By jgomez Date 2020-09-17 Time 13:44 Sent To  
Notes
2020-09-17 14:06:29CONCRETE PAD ENGINERING DWG 17-5169B WITH ENGINEER'S
 ORIGINAL SEAL/SIGNATURE MATCHES APPROVED ONE. JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-08-21 Cont ID  
Sent By shill Date 2020-08-21 Time 16:04 Rev Time 0.00
Received By shill Date 2020-08-21 Time 16:04 Sent To  
Notes
2020-08-21 16:05:01****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A WET SIGNATURE IS NOT CONSIDERED
 A DIGITAL SIGNATURE.
  
 EITHER UPLOAD A DIGITALLY SIGNED DOCUMENT OR DROP OFF
 (OR MAIL) ONE PAPER ORIGINAL:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-08-15 Cont ID  
Sent By cthroop Date 2020-08-15 Time 11:55 Rev Time 0.00
Received By cthroop Date 2020-08-15 Time 11:22 Sent To  
Notes
2020-08-15 11:57:57PLAN REVIEW GENERATOR - SIGNATURES
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1) THE DESIGNERS DIGITAL SIGNATURE ON THE GENERATOR PAD
 ENGINEERING AND DESIGN WIND LOAD CALCS. CANNOT BE
 VERIFIED. FS 471 & FAC 61G15
  
 2) DIGITAL SIGNATURES ARE NOT IN ACCORDANCE WITH FS
 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE NEXT
 REVIEW CYCLE REQUIRE REVIEW.
  
 3) UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT.
  
  
 OPTION:
  
 YOU MAY ELECT TO PROVIDE A HARD COPY OF PLANS WITH
 VALID SIGNATURE OF CONTRACTOR OR DESIGNER PRIOR TO
 PERMIT. A DROP BOX HAS BEEN INSTALLED OUTSIDE CITY HALL
 FOR THIS PURPOSE. CONTACT THE OFFICE OF DEVELOPMENT
 SERVICES @ 561-805-8700 OR [email protected] TO STATE YOUR
 INTENTIONS. CITY STAFF WILL REVIEW YOUR DOCUMENTS AND
 IF APPROVED YOU WILL RECIEVE AN E-MAIL INSTRUCTING YOU
 TO DOWNLOAD AND PRINT YOUR PERMIT AND PLANS.
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2020-08-28 Cont ID  
Sent By kalexand Date 2020-08-28 Time 16:58 Rev Time 0.00
Received By kalexand Date 2020-08-28 Time 16:58 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-08-18 Cont ID  
Sent By kalexand Date 2020-08-18 Time 17:23 Rev Time 0.00
Received By kalexand Date 2020-08-18 Time 17:23 Sent To I
Notes
***NONE***