Plan Review Details - Permit 20071072
| Plan Review Stops For Permit 20071072 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-01-06 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-01-06 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-01-06 |
Time |
06:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-09-01 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2020-09-01 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2020-09-01 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2020-09-01 11:23:27 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | | ALTERNATE: CONTACT PETER VALENTI (561) 805-6673 | | | [email protected] | | | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1.FBC B 107.2.1. ON THE SCHEDULE FOR INSTALLATION OF | | | PROTECTIVE DEVICES OR ASSEMBLIES: PLEASE CORRECT COLUMN | | | HEADING ?SHUTTER MOUNTING CONNECTION TYPE PER PRODUCT | | | APPROVAL?; PROVIDE INFORMATION FROM SHEETS 6 & 7 OF | | | FL1850 USE ALPHABETICAL LETTER THAT CORRESPONDS WITH | | | THE CONNECTION TYPE FOR THE TOP AND BOTTOM CONNECTIONS. | | | PLEASE CORRECT COLUMN HEADING ?ANCHOR SPACING? PLEASE | | | NOTE PAGE 13 OF 20, FACTORS APPLY USING ANCHOR ALL | | | POINT SOLID SET WITH A 3? MIN. EDGE DISTANCE REQUIRES A | | | 0.78 FACTOR. REDUCE ANCHOR SPACING BY MULTIPLYING | | | SPACING SHOWN ON SCHEDULE BY THE FACTOR. | | | 2. REVISE PLAN TO SHOW MEANS OF ESCAPE REQUIRED BY FBC | | | R 310.4; INCLUDE ROOM DESIGNATION. SECOND REQUEST. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2020-08-04 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2020-08-04 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2020-08-04 10:35:54 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | | ALTERNATE: CONTACT SAMANTHA HILL (561) 805-6724 | | | [email protected] | | | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. FBC R 301, COMPLETE THE "SCHEDULE FOR INSTALLATION | | | OF OPENING PROTECTIVE DEVICES" OR PROVIDE ALL | | | INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL | | | SPREADSHEET): | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS?PAGE=2 | | | 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE | | | NOTE PAGE 13 OF 20, FACTORS APPLY DEPENDING ON | | | SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF | | | USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON | | | W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR). | | | 3. REVISE PLAN TO SHOW MEANS OF ESCAPE REQUIRED BY FBC | | | R 310.4; INCLUDE ROOM DESIGNATION | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-01-06 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-01-06 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-01-05 |
Time |
13:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-09-01 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2020-09-01 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2020-08-25 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2020-08-27 09:33:39 | SENT TO UNDER $5000 BUILDING. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2020-08-04 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2020-08-03 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2020-08-03 13:57:21 | TO MISC 1 | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy