Plan Review Details - Permit 20071071
Plan Review Stops For Permit 20071071
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-08-07 Cont ID  
Sent By cthroop Date 2020-08-07 Time 11:04 Rev Time 0.00
Received By cthroop Date 2020-08-07 Time 11:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-05 Cont ID  
Sent By cthroop Date 2020-08-05 Time 09:58 Rev Time 0.00
Received By cthroop Date 2020-08-05 Time 06:45 Sent To  
Notes
2020-08-05 10:45:38PLAN REVIEW - BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DESIGN PARAMETERS - FBC EXISTING BUILDING ALTERATION
 LEVEL 2
 SECTION 504
 ALTERATION?LEVEL 2
 504.1SCOPE.
 LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF
 SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR
 WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM,
 OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT.
 504.2 APPLICATION. LEVEL 2 ALTERATIONS SHALL COMPLY
 WITH THE PROVISIONS OF CHAPTER 7 FOR LEVEL 1
 ALTERATIONS AS WELL AS THE PROVISIONS OF CHAPTER 8.
  
 2. PROVIDE EXTERIOR ELEVATION PLAN. INCLUDE FRAMING
 DETAILS FASTENER SCHEDULE AND DEMENSIONS.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 3. NOTE ON WIND LOAD CALCULATIONS STATES RESULTS ARE
 NOT VALID WITHOUT AN ORIGINAL SIGNATURE AND RAISED SEAL
 BY A LICENSED PROFESSIONAL ENGINEER.
 SUBMIT WINDLOAD CALC'S WITH VALID DIGITAL SIGNATURE OF
 DESIGN PROFESSIONAL.
 OPTION - YOU MAY REMOVE THIS NOTE AND HAVE THE
 CONTRACTOR SIGN THE WIND LOAD CALC'S.
  
 4. PRODUCT APPROVAL FL21855-R1. DESIGNER TO SELECT
 MODEL OF DOOR TO BE INSTALLED. IF NON-IMPACT RATED DOOR
 IS SELECTED PROVIDE OPENING PROTECTION DEVICE.
 DESIGNER/CONTRACTOR TO REVIEW AND APPROVE PRODUCT
 APPROVALS.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 5. LANDING REQUIRED AT EXTERIOR DOORS.
 R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS.
 THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH
 EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NOT BE
 LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A
 MINIMUM DIMENSION OF 36 INCHES (914 MM) MEASURED IN THE
 DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE
 PERMITTED TO HAVE A SLOPE NOT TO EXCEED 1/4 UNIT
 VERTICAL IN 12 UNITS HORIZONTAL (2-PERCENT).
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2020-08-07 Cont ID  
Sent By cthroop Date 2020-08-07 Time 11:04 Rev Time 0.00
Received By cthroop Date 2020-08-07 Time 11:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-08-05 Cont ID  
Sent By cthroop Date 2020-08-05 Time 10:45 Rev Time 0.00
Received By cthroop Date 2020-08-05 Time 06:45 Sent To  
Notes
2020-08-05 10:46:43PLAN REVIEW - ELECTRICAL
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DESIGN PARAMETERS - FBC EXISTING BUILDING ALTERATION
 LEVEL 2
 SECTION 504
 ALTERATION?LEVEL 2
 504.1SCOPE.
 LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF
 SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR
 WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM,
 OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT.
 504.2 APPLICATION. LEVEL 2 ALTERATIONS SHALL COMPLY
 WITH THE PROVISIONS OF CHAPTER 7 FOR LEVEL 1
 ALTERATIONS AS WELL AS THE PROVISIONS OF CHAPTER 8.
  
 2. PROVIDE ILLUMINATION AT EXTERIOR DOOR PER E3401.4
 ADDITIONS AND ALTERATIONS.
 E3903.3 ADDITIONAL LOCATIONS.
 AT LEAST ONE WALL-SWITCH-CONTROLLED LIGHTING OUTLET
 SHALL BE INSTALLED IN HALLWAYS, STAIRWAYS, ATTACHED
 GARAGES, AND DETACHED GARAGES WITH ELECTRIC POWER. AT
 LEAST ONE WALL-SWITCH-CONTROLLED LIGHTING OUTLET SHALL
 BE INSTALLED TO PROVIDE ILLUMINATION ON THE EXTERIOR
 SIDE OF EACH OUTDOOR EGRESS DOOR HAVING GRADE LEVEL
 ACCESS,
  
 3. PROVIDE AN ELECTRICAL PLAN.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 4. AN ELECTRICAL SUB-PERMIT IS REQUIRED.
 PERMITS - 105.1 REQUIRED.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-07 Cont ID  
Sent By cthroop Date 2020-08-07 Time 11:05 Rev Time 0.00
Received By cthroop Date 2020-08-07 Time 11:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-05 Cont ID  
Sent By cthroop Date 2020-08-05 Time 11:00 Rev Time 0.00
Received By cthroop Date 2020-07-22 Time 14:13 Sent To  
Notes
2020-07-31 14:13:45CONVERTED TO DIGITAL. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2020-08-05 Cont ID  
Sent By cthroop Date 2020-08-05 Time 09:58 Rev Time 0.00
Received By cthroop Date 2020-08-05 Time 06:45 Sent To  
Notes
2020-08-05 09:58:41NON-CONDITIONED SPACE. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-08-07 Cont ID  
Sent By cthroop Date 2020-08-07 Time 11:04 Rev Time 0.00
Received By cthroop Date 2020-08-07 Time 11:04 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-08-05 Cont ID  
Sent By cthroop Date 2020-08-05 Time 09:16 Rev Time 0.00
Received By cthroop Date 2020-08-05 Time 06:45 Sent To  
Notes
2020-08-05 09:20:06PLAN REVIEW - DIGITAL SIGNATURES AND SEALS
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NON-DESIGN PROFESSIONALS
  
 1. THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE A
 TITLE BLOCK AND SIGNATURE ON PLAN SHEETS UNDER THEIR
 AUTHORITY
 2017 WPB AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1, SECTION 107.2.1.
  
  
 2. UPLOAD DOCUMENTS VIA THE PROJECTDOX PORTAL WITH
 SIGNATURE OF DESIGNER AS APPLICABLE; USE THE REQUIRED
 NAMING CONVENTION FOR EACH DOCUMENT.
  
  
  
  