| Plan Review Stops For Permit 20071019 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-09-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-09-02 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-09-02 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2020-09-02 13:47:13 | TALKED TO ODLANYER ALVAREZ (OWNER). INSTALLING ASSEMBLY | | | SYSTEM TYPE E(6) ON PAGE 27 OF NOA 17-08 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-08-19 |
Time |
06:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-08-19 |
Time |
06:49 |
Sent To |
|
|
| Notes |
| 2020-08-19 06:58:28 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. THE CALCULATIONS FOR THE FLAT DECK SPECIFY 8" | | | SPACING IN THE FIELD, 16" IN ZONE 2, 10" IN ZONE 3. THE | | | ENGINEERING DOES NOT SPECIFY THE NUMBER OF ROWS | | | REQUIRED FOR ZONES 2 AND 3. REVISE ENGINEERING TO | | | SPECIFY NUMBER OF ROWS FOR EACH ZONE, AND IF THE | | | FASTENING FOR ZONES 2 AND 3 ARE NOT REVISED, PROVIDE | | | CALCULATIONS, FBC B 1609. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-05 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-05 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2020-08-05 08:49:25 | ROOFING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) IN THE PRODUCT APPROVAL PROVIDED FOR THE FLAT DECK - | | | PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN THE | | | ROOFING PRODUCT APPROVAL - ROOFING SYSTEM TO BE USED ON | | | THE PROVIDED PRODUCT APPROVAL MAY REQUIRE ADDITIONAL | | | SIGNED AND SEALED ATTACHMENT DETAILS FROM AN ARCHITECT | | | OR ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A | | | HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE PRODUCT | | | APPROVAL - SEE GENERAL LIMITATION NOTE NUMBER 7 ON THE | | | PRODUCT APPROVAL. SIGNED AND SEALED DRAWINGS OR | | | DOCUMENTS WILL NEED TO BE DIGITALLY SIGNED AND SEALED | | | TO BE USED IN ELECTRONIC PLAN REVIEW. SHOW THE WIND | | | DESIGN DATA USED ON THE ADDITIONAL ATTACHMENT DETAILS | | | PER 2017 FBC AND ASCE 7-10 - WIND SPEED - EXPOSURE - | | | RISK CATEGORY - ETC. | | | 2) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVAL FOR THE SHINGLES. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-09-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-09-02 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-09-02 |
Time |
11:43 |
Sent To |
I |
|
| Notes |
| 2020-09-02 13:35:13 | TALKED TO ODLANYER ALVAREZ (OWNER). INSTALLING ASSEMBLY | | | SYSTEM TYPE E(6) ON PAGE 27 OF NOA 17-0824.11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-08-19 |
Time |
07:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-08-12 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-05 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-27 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
N |
Date |
2020-09-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-09-02 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-09-02 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2020-09-02 13:49:36 | NO RAS 117 CALCULATIONS REQUIRED FOR SELECTED ASSEMBLY. | | | JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-08-19 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-08-19 |
Time |
07:01 |
Sent To |
|
|
| Notes |
| 2020-08-19 07:02:41 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. | | | | | | EITHER UPLOAD DIGITALLY SIGNED AND SEALED ENGINEERING | | | OR DROP OFF OR MAIL ONE PAPER ORIGINAL TO CITY HALL : | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-05 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-05 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|