Plan Review Details - Permit 20071019
Plan Review Stops For Permit 20071019
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-09-02 Cont ID  
Sent By jgomez Date 2020-09-02 Time 13:35 Rev Time 0.00
Received By jgomez Date 2020-09-02 Time 11:43 Sent To  
Notes
2020-09-02 13:47:13TALKED TO ODLANYER ALVAREZ (OWNER). INSTALLING ASSEMBLY
 SYSTEM TYPE E(6) ON PAGE 27 OF NOA 17-08

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-08-19 Cont ID  
Sent By shill Date 2020-08-19 Time 06:55 Rev Time 0.00
Received By shill Date 2020-08-19 Time 06:49 Sent To  
Notes
2020-08-19 06:58:28****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. THE CALCULATIONS FOR THE FLAT DECK SPECIFY 8"
 SPACING IN THE FIELD, 16" IN ZONE 2, 10" IN ZONE 3. THE
 ENGINEERING DOES NOT SPECIFY THE NUMBER OF ROWS
 REQUIRED FOR ZONES 2 AND 3. REVISE ENGINEERING TO
 SPECIFY NUMBER OF ROWS FOR EACH ZONE, AND IF THE
 FASTENING FOR ZONES 2 AND 3 ARE NOT REVISED, PROVIDE
 CALCULATIONS, FBC B 1609.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-05 Cont ID  
Sent By rmcphers Date 2020-08-05 Time 08:50 Rev Time 0.00
Received By rmcphers Date 2020-08-05 Time 08:40 Sent To  
Notes
2020-08-05 08:49:25ROOFING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) IN THE PRODUCT APPROVAL PROVIDED FOR THE FLAT DECK -
 PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN THE
 ROOFING PRODUCT APPROVAL - ROOFING SYSTEM TO BE USED ON
 THE PROVIDED PRODUCT APPROVAL MAY REQUIRE ADDITIONAL
 SIGNED AND SEALED ATTACHMENT DETAILS FROM AN ARCHITECT
 OR ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A
 HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE PRODUCT
 APPROVAL - SEE GENERAL LIMITATION NOTE NUMBER 7 ON THE
 PRODUCT APPROVAL. SIGNED AND SEALED DRAWINGS OR
 DOCUMENTS WILL NEED TO BE DIGITALLY SIGNED AND SEALED
 TO BE USED IN ELECTRONIC PLAN REVIEW. SHOW THE WIND
 DESIGN DATA USED ON THE ADDITIONAL ATTACHMENT DETAILS
 PER 2017 FBC AND ASCE 7-10 - WIND SPEED - EXPOSURE -
 RISK CATEGORY - ETC.
 2) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVAL FOR THE SHINGLES.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-09-02 Cont ID  
Sent By jgomez Date 2020-09-02 Time 13:35 Rev Time 0.00
Received By jgomez Date 2020-09-02 Time 11:43 Sent To I
Notes
2020-09-02 13:35:13TALKED TO ODLANYER ALVAREZ (OWNER). INSTALLING ASSEMBLY
 SYSTEM TYPE E(6) ON PAGE 27 OF NOA 17-0824.11

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-19 Cont ID  
Sent By shill Date 2020-08-19 Time 07:02 Rev Time 0.00
Received By shill Date 2020-08-12 Time 09:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-05 Cont ID  
Sent By rmcphers Date 2020-08-05 Time 08:51 Rev Time 0.00
Received By rmcphers Date 2020-07-27 Time 10:58 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status N Date 2020-09-02 Cont ID  
Sent By jgomez Date 2020-09-02 Time 13:29 Rev Time 0.00
Received By jgomez Date 2020-09-02 Time 13:29 Sent To  
Notes
2020-09-02 13:49:36NO RAS 117 CALCULATIONS REQUIRED FOR SELECTED ASSEMBLY.
 JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-08-19 Cont ID  
Sent By shill Date 2020-08-19 Time 07:01 Rev Time 0.00
Received By shill Date 2020-08-19 Time 07:01 Sent To  
Notes
2020-08-19 07:02:41****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS.
  
 EITHER UPLOAD DIGITALLY SIGNED AND SEALED ENGINEERING
 OR DROP OFF OR MAIL ONE PAPER ORIGINAL TO CITY HALL :
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-08-05 Cont ID  
Sent By rmcphers Date 2020-08-05 Time 08:50 Rev Time 0.00
Received By rmcphers Date 2020-08-05 Time 08:50 Sent To  
Notes
***NONE***