Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-09-01 Cont ID  
Sent By rmcphers Date 2020-09-01 Time 07:36 Rev Time 0.00
Received By rmcphers Date 2020-09-01 Time 07:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-08-26 Cont ID  
Sent By rmcphers Date 2020-08-26 Time 13:20 Rev Time 0.00
Received By rmcphers Date 2020-08-26 Time 13:20 Sent To  
Notes
2020-08-26 13:26:55ROOFED PATIO
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
  
 2ND REVIEW
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE ROOF SLOPE (MIN. 1/4 IN 12) ON THE
 DRAWINGS TO COMPLY WITH FBC R905.9.1
 2) IN THE PRODUCT APPROVAL PROVIDED FOR THE FLAT DECK -
 PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN THE
 ROOFING PRODUCT APPROVAL - SEE PAGE 21 OF 27 IN THE
 PRODUCT APPROVAL WHERE DECK TYPE "WOOD NON-INSULATED"
 STARTS THEN CIRCLE A ROOFING "SYSTEM TYPE" AND
 "ATTACHMENT OPTION" ETC. THERE ARE MORE OPTIONS ON THE
 PRECEDING PAGES OF THE PRODUCT APPROVAL - ROOFING
 SYSTEM TO BE USED ON THE PROVIDED PRODUCT APPROVAL MAY
 REQUIRE ADDITIONAL SIGNED AND SEALED ATTACHMENT DETAILS
 FROM AN ARCHITECT OR ENGINEER FOR ROOF WIND ZONES 2 AND
 3 WHICH REQUIRE A HIGHER PRESSURE THAN THE MAXIMUM
 SHOWN ON THE PRODUCT APPROVAL - SEE GENERAL LIMITATION
 NOTE NUMBER 7 ON THE PRODUCT APPROVAL. OR PROVIDE A
 STATEMENT THAT YOU WOULD LIKE TO DEFER THE ROOFING
 SUBMITTALS.
  
 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE
 DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT
 SUBMITTED AT THE TIME OF THE APPLICATION
 AND THAT ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL
 WITHIN A SPECIFIED PERIOD. DEFERRAL OF ANY
 SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE
 BUILDING OFFICIAL. THE REGISTERED DESIGN
 PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE
 DEFERRED SUBMITTALS ON THE CONSTRUCTION
 DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-14 Cont ID  
Sent By rmcphers Date 2020-08-14 Time 11:14 Rev Time 0.00
Received By rmcphers Date 2020-08-14 Time 09:34 Sent To  
Notes
2020-08-14 11:10:51ROOFED PATIO
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE ROOF SLOPE (MIN. 1/4 IN 12) ON THE
 DRAWINGS TO COMPLY WITH FBC R905.9.1
 2) IN THE PRODUCT APPROVAL PROVIDED FOR THE FLAT DECK -
 PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN THE
 ROOFING PRODUCT APPROVAL - ROOFING SYSTEM TO BE USED ON
 THE PROVIDED PRODUCT APPROVAL MAY REQUIRE ADDITIONAL
 SIGNED AND SEALED ATTACHMENT DETAILS FROM AN ARCHITECT
 OR ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A
 HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE PRODUCT
 APPROVAL - SEE GENERAL LIMITATION NOTE NUMBER 7 ON THE
 PRODUCT APPROVAL.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-08-15 Cont ID  
Sent By cthroop Date 2020-08-15 Time 11:12 Rev Time 0.00
Received By cthroop Date 2020-08-15 Time 10:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-26 Cont ID  
Sent By rmcphers Date 2020-08-26 Time 13:38 Rev Time 0.00
Received By rmcphers Date 2020-08-17 Time 11:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-15 Cont ID  
Sent By cthroop Date 2020-08-15 Time 11:12 Rev Time 0.00
Received By cthroop Date 2020-07-28 Time 09:59 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2020-09-01 Cont ID  
Sent By rmcphers Date 2020-09-01 Time 07:35 Rev Time 0.00
Received By rmcphers Date 2020-09-01 Time 07:35 Sent To  
Notes
2020-09-01 07:36:20DEFERRED

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-08-26 Cont ID  
Sent By rmcphers Date 2020-08-26 Time 13:36 Rev Time 0.00
Received By rmcphers Date 2020-08-26 Time 13:36 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-08-14 Cont ID  
Sent By rmcphers Date 2020-08-14 Time 11:14 Rev Time 0.00
Received By rmcphers Date 2020-08-14 Time 11:14 Sent To  
Notes
2020-07-23 08:49:42DIGITALLY SIGNED DRAWINGS IN 'SIGNATURE' FOLDER

Review Stop Z ZONING
Rev No 1 Status P Date 2020-08-05 Cont ID  
Sent By rthermid Date 2020-08-05 Time   Rev Time  
Received By rthermid Date 2020-08-05 Time   Sent To I
Notes
***NONE***