| Plan Review Stops For Permit 20070892 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2021-04-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-23 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-23 |
Time |
07:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2021-01-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-01-14 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-01-14 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2021-01-14 11:09:22 | PLAN | | | REVIEW COMMENTS | | | 3RD REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR THE WINDOW, EXTERIOR | | | DOORS AND METAL ROOF (SHED). THESE ITEMS CAN BE | | | DEFERRED IF REQUESTED, HOWEVER, THE DOCUMENTS MUST BE | | | SUBMITTED AND APPROVED BY THE BUILDING DEPARTMENT | | | BEFORE THEY CAN BE INSTALLED. ONLY ONE SET IS REQUIRED | | | TO BE UPLOADED FOR ELECTRONICALLY SUBMITTED DOCUMENTS. | | | NO PRODUCT APPROVALS WERE SUBMITTED. | | | | | | 2) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2020-12-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-12-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-12-16 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2020-12-16 10:04:11 | PLAN | | | REVIEW COMMENTS | | | 3RD REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR THE WINDOW AND | | | EXTERIOR DOOR. THESE ITEMS CAN BE DEFERRED IF | | | REQUESTED, HOWEVER, THE DOCUMENTS MUST BE SUBMITTED AND | | | APPROVED BY THE BUILDING DEPARTMENT BEFORE THEY CAN BE | | | INSTALLED. ONLY ONE SET IS REQUIRED TO BE UPLOADED FOR | | | ELECTRONICALLY SUBMITTED DOCUMENTS. NO PRODUCT | | | APPROVALS WERE SUBMITTED. | | | | | | 2) SUBMIT SITE SPECIFIC ENGINEERING OR MANUFACTURED | | | BUILDING DOCUMENTS FOR THE PRE-FAB SHED THAT WILL BE | | | HOUSING THE LAUNDRY EQUIPMENT. PROVIDE FOUNDATION AND | | | ANCHORING DETAILS. CITY AMENDMENTS FBC 107.2.1 & FBC | | | 107.3.5.3 THE INFORMATION FOR THE SHED THAT WAS | | | SUBMITTED DOES NOT MEET THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE. IT IS NOT AN APPROVED MANUFACTURED | | | BUILDING AND THERE ARE NO SIGNED AND SEALED DOCUMENTS | | | FROM AN ENGINEER OR A PRODUCT APPROVAL. | | | | | | 3) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-10-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-22 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-22 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2020-10-22 14:45:18 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR THE WINDOW AND | | | EXTERIOR DOOR. THESE ITEMS CAN BE DEFERRED IF | | | REQUESTED, HOWEVER, THE DOCUMENTS MUST BE SUBMITTED AND | | | APPROVED BY THE BUILDING DEPARTMENT BEFORE THEY CAN BE | | | INSTALLED. ONLY ONE SET IS REQUIRED TO BE UPLOADED FOR | | | ELECTRONICALLY SUBMITTED DOCUMENTS. | | | | | | 2) SUBMIT SITE SPECIFIC ENGINEERING OR MANUFACTURED | | | BUILDING DOCUMENTS FOR THE PRE-FAB SHED THAT WILL BE | | | HOUSING THE LAUNDRY EQUIPMENT. PROVIDE FOUNDATION AND | | | ANCHORING DETAILS. CITY AMENDMENTS FBC 107.2.1 & FBC | | | 107.3.5.3 | | | | | | 3) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-08-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-08-24 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-08-24 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2020-08-24 09:27:43 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) PLEASE ADDRESS FBC-R314.3.1 ALTERATIONS, REPAIRS AND | | | ADDITIONS. WHEN ALTERATIONS, REPAIRS OR ADDITIONS | | | REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING | | | ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE | | | INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE | | | ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. | | | | | | 2) PLEASE ADDRESS IF APPLICABLE FBC-R315.1 CARBON | | | MONOXIDE PROTECTION. EVERY SEPARATE BUILDING OR AN | | | ADDITION TO AN EXISTING BUILDING FOR WHICH A PERMIT FOR | | | NEW CONSTRUCTION IS ISSUED AND HAVING A | | | FOSSIL-FUEL-BURNING HEATER OR APPLIANCE, A FIREPLACE, | | | AN ATTACHED GARAGE, OR OTHER FEATURE, FIXTURE, OR | | | ELEMENT THAT EMITS CARBON MONOXIDE AS A BYPRODUCT OF | | | COMBUSTION SHALL HAVE AN OPERATIONAL CARBON MONOXIDE | | | ALARM INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR | | | SLEEPING PURPOSES. | | | | | | 3) FBC ENERGY CONSERVATION SECTION R101.4.5 REQUIRES | | | ANY UNCONDITIONED SPACE THAT IS ALTERED TO BECOME | | | CONDITIONED SPACE TO BE BROUGHT INTO FULL COMPLIANCE | | | WITH THE ENERGY CODE. SUBMIT TWO SETS OF FORMS AND | | | DOCUMENTS TO SHOW COMPLIANCE. FBC ENERGY CONSERVATION | | | SECTION R103. | | | | | | 4) SPECIFY THE REQUIRED WALL INSULATION ON THE PLANS. | | | FBC ENERGY CONSERVATION AND CITY AMENDMENTS FBC 107.2.1 | | | | | | 5) SHOW THAT ADEQUATE ATTIC VENTILATION IS PROVIDED AS | | | REQUIRED BY R806.1 & R806.2. ENCLOSED ATTICS AND | | | ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE | | | APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL | | | HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY | | | VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF | | | RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE A LEAST | | | DIMENSION OF 1/16 INCH (1.6 MM) MINIMUM AND 1/4 INCH | | | (6.4 MM) MAXIMUM. VENTILATION OPENINGS HAVING A LEAST | | | DIMENSION LARGER THAN 1/4 INCH (6.4 MM) SHALL BE | | | PROVIDED WITH CORROSION-RESISTANT WIRE CLOTH SCREENING, | | | HARDWARE CLOTH OR SIMILAR MATERIAL WITH OPENINGS HAVING | | | A LEAST DIMENSION OF 1/16 INCH (1.6 MM) MINIMUM AND 1/4 | | | INCH (6.4 MM) MAXIMUM. OPENINGS IN ROOF FRAMING MEMBERS | | | SHALL CONFORM TO THE REQUIREMENTS OF SECTION R802.7. | | | REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO | | | THE OUTSIDE AIR. | | | | | | 6) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT | | | ROOFING MATERIALS, WINDOW (GLASS TYPES), STRUCTURAL | | | MULLIONS AND EXTERIOR DOOR TYPES. THESE ITEMS CAN BE | | | DEFERRED IF REQUESTED, HOWEVER, THE DOCUMENTS MUST BE | | | SUBMITTED AND APPROVED BY THE BUILDING DEPARTMENT | | | BEFORE THEY CAN BE INSTALLED. ONLY ONE SET IS REQUIRED | | | TO BE UPLOADED FOR ELECTRONICALLY SUBMITTED DOCUMENTS. | | | | | | 7) THE NEW FLOOR PLAN ON SHEET A2 SHOWS A PREFAB SHED | | | FOR THE LAUNDRY EQUIPMENT AND IT IS NOT SHOWN ON THE | | | SITE PLAN. IS THIS SHED GOING TO BE APPLIED FOR UNDER A | | | SEPARATE PERMIT? IF IT WILL BE UNDER THIS PERMIT, ADD | | | IT TO THE SITE PLAN AND SUBMIT THE SITE SPECIFIC | | | ENGINEERING OR MANUFACTURED BUILDING DOCUMENTS FOR THE | | | SHED. CITY AMENDMENTS FBC 107.2.1 & FBC 107.3.5.3 | | | | | | 8) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-10-20 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-10-20 |
Time |
21:09 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-10-20 |
Time |
19:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-08-12 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-08-12 |
Time |
19:50 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-08-12 |
Time |
19:09 |
Sent To |
|
|
| Notes |
| 2020-08-12 19:38:32 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. NO SMOKE ALARMS SHOWN. PROVIDE CORRECTION FBC-R 314 | | | &315 | | | | | | 2. ELECTRICAL RISER SHOWS 3-2/0 AND 1-#6 GROUND FROM | | | METER CAN TO SERVICE DISCONNECTING MEANS. THIS PROVIDES | | | A PARALLEL PATH BACK TO THE GROUNDED CONDUCTOR WHICH IS | | | NOT PERMITTED. REMOVE EQUIPMENT GROUNDING CONDUCTOR | | | FROM RISER. NEC 250.24B ALSO REMOVE GROUND FROM PIPE | | | FROM TRANSFORMER TO METER. | | | | | | 3. GROUNDING ELECTRODE SYSTEM SHOWS #6 GEC TO GROUND | | | RODS, C/W PIPE, AND BUILDING STEEL. #6 IS INSUFFICIENT | | | SIZE TO CONNECT TO C/W PIPE AND BUILDING STEEL. PROVIDE | | | CORRECTION. NEC 250.66A&B | | | | | | 4. NO INTERSYSTEM CONNECTION (BONDING BRIDGE) SHOWN ON | | | RISER DIAGRAM NEC 250.94 | | | | | | 5. LOAD CALCULATION IS INCORRECT. CHECK MATH. FIRST 10K | | | AT 100% THEN THE REMAINDER OF THE GENERAL LOAD AT 40% | | | WOULD BE 18,776W NOT 14,776W. | | | | | | HEATER IS SPELLED HEATHER. | | | | | | PROVIDE ACCURATE LOAD CALCULATION SHOWING PREVIOUS LOAD | | | AND ADDITION OF NEW LOADS. NEC 220 | | | | | | 6. PERMIT APPLICATION FOR ELECTRICAL HAS NO CONTRACTOR | | | NAMED OR AN OWNER BUILDER DESIGNATION AND HAS NO VALUE | | | ASSIGNED TO IT. PLEASE COMPLETE PERMIT APP. IF VALUE IS | | | INCLUDED IN MASTER PERMIT FOR ELECTRIC ANNOTATE THAT ON | | | PERMIT APP.. FBC 107.2.1 | | | | | | 7. RELOCATED METER AND NEW PANEL PLACEMENT SHOWN ON | | | PLAN BUT NO LOCATION OF SERVICE DISCONNECT IS PROVIDED. | | | SHOW LOCATION ON PLAN. FBC 107.2.1 | | | | | | 8. PROVIDE ARC-FAULT PROTECTION WHERE NEEDED PER NEC | | | 210.12. | | | | | | 9. PROVIDE NOTE ON PLAN THAT RECEPTACLES WILL BE TAMPER | | | PROOF PER NEC 406.12 | | | | | | 10. SHOW LOCATION AND DISCONNECT FOR MINI-SPLIT | | | COMPRESSOR UNIT. FBC 107.2.1 | | | | | | 11. RELOCATED WASHER RECEPTACLE MUST BE AFCI/GFCI | | | PROTECTED PER NEC 210.12B AND NEC 210.8 | | | | | | 12. RECEPTACLE REQUIRED TO RIGHT OF ENTRY DOOR PER NEC | | | 210.52 | | | | | | 13. WASHER/DRYER CIRCUIT SHOWN AT #10 WIRE WITH 40AMP | | | OVERCURRENT PROTECTION. THIS IS A VIOLATION PER NEC | | | 240.4. PROVIDE CORRECTION. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-04-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-23 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-13 |
Time |
11:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-04-08 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-01-13 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-12-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-12-16 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-12-04 |
Time |
15:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-10-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-22 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-08 |
Time |
07:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-08-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-08-24 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-22 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
5 |
Status |
P |
Date |
2021-05-14 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-05-14 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-04-23 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2021-04-23 08:29:30 | 4/23/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
F |
Date |
2021-04-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-23 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-23 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2021-04-23 07:12:51 | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2021-01-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-01-14 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-01-14 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2021-01-14 11:39:56 | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2021-01-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-01-14 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-01-14 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2021-01-14 11:10:52 | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-08-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-08-24 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-08-24 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2020-08-24 07:56:04 | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-10-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-10-13 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-10-13 |
Time |
16:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-08-05 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-08-05 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2020-08-05 09:10:58 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT- 20070892 | | | | | | CODES IN EFFECT: | | | | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THIS | | | PROJECT. FBC EC 101.5.1.1.2 | | | | | | 2) PLEASE PROVIDE THE HEATING AND COOLING SIZING | | | CALCULATIONS. FBC EC R403.7 | | | | | | 3) PLEASE PROVIDE SPECS FOR THE REQUIRED BATHROOM | | | EXHAUST FAN AND SHOW THAT THE REQUIRED BATHROOM EXHAUST | | | MEETS: FBC RES M1507.4 | | | | | | 4) PLEASE PROVIDE THE DRYER DUCT INFORMATION ON THE | | | MECHANICAL SHEET. I.E. SIZE TYPE OF MATERIAL AND | | | TERMINATION LOCATION. FBC M 508 | | | | | | 5) PLEASE SHOW MAKEUP AIR FOR DRYER. FBC M 504.6 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-10-14 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-10-14 |
Time |
20:15 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-10-14 |
Time |
20:15 |
Sent To |
|
|
| Notes |
| 2020-10-14 20:15:35 | 10/14/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-08-10 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-08-10 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-08-10 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2020-08-10 16:53:54 | 08/10/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | | | | 1. THE OVERALL VALUE IS LOW PER THE WPB AMENDMENTS TO | | | THE FBC 109.3 BUILDING PERMITS VALUATIONS. IF IN THE | | | OPINION OF THE BUILDING OFFICIAL, THE CLAIMED VALUATION | | | OF BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED UNLESS THE APPLICANT CAN SHOW DETAILED, QUANTITY | | | ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS (EXCLUDING | | | LAND VALUE) TO MEET THE APPROVAL OF THE BUILDING | | | OFFICIAL. FOR PERMITTING PURPOSES, THE VALUATION OF | | | BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE | | | TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, | | | INTERIOR FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND | | | DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT; | | | EXCLUDING ONLY LAND VALUE. VALUATION REFERENCES MAY | | | INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL | | | CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT, | | | MEANS, ETC.), AS PUBLISHED BY INTERNATIONAL CODE | | | CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE SET | | | BY THE BUILDING OFFICIAL. | | | | | | 2. PLUMBING RISER DIAGRAM REQUIRED PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL | | | PLUMBING. | | | | | | 3. CLEAN OUT REQUIRED EVERY TIME YOU ENTER THE BUILDING | | | PLEASE SHOW A CLEAN OUT ON THE WASHING MACHINE DRAIN | | | LINE PER THE 2017 FBC SEC. R3005.2.3. | | | | | | 4. WASHING MACHINE DRAINAGE LINE PER MOST MANUFACTURES | | | SPECIFICATION SHALL BE 3" DUE TO THE PUMP DISCHARGE | | | VOLUME, PLEASE SHOW AS SO ON ISOMETRIC PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL | | | PLUMBING. | | | | | | 5. WATER LINE OUTSIDE CONDITION SPACE SHALL BE | | | INSULATED WITH AN R-3 MINIMUM PER THE 2017 FBC RE SEC. | | | 403.5.3. | | | | | | 6. WATER IS NOT IDENTIFIED AS TYPE I.E., ELECTRIC, GAS, | | | TANK OR TANKLESS, PLEASE SUBMIT SPECIFICATION TO | | | DETERMINE IF DRAINAGE TO THE OUTSIDE, THERMAL EXPANSION | | | OR RELIEF LINE IS REQUIRED PER THE WPB AMENDMENTS TO | | | THE FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-01-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-01-14 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-01-14 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-10-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-10-13 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-10-13 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2020-10-13 16:12:58 | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-08-05 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-08-05 |
Time |
09:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-04-07 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-04-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2021-04-07 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-10-20 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-10-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2020-10-20 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-08-10 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-08-10 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2020-08-10 |
Time |
|
Sent To |
I |
|
| Notes |
|
|