| Plan Review Stops For Permit 20070724 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-10-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-05 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-05 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-09-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-23 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-23 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2020-09-23 08:56:34 | ALTERATION LEVEL III | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) DRAWING S2.0 SHOWS "EXISTING ROOFING SYSTEM TO | | | REMAIN - YET YOU HAVE ROOFING SYSTEMS UPLOADED TO | | | PROJECTDOX. | | | 2) PLEASE PROVIDE DETAILS OR A STATEMENT ON THE DRAWING | | | ON HOW AND TO WHAT EXTENT YOU WILL BE USING TO COMPLY | | | WITH FBC EXISTING BUILDING 706.8 | | | WHEN A ROOF COVERING ON AN EXISTING SITE-BUILT | | | SINGLEFAMILY RESIDENTIAL STRUCTURE IS REMOVED AND | | | REPLACED ON A BUILDING THAT IS LOCATED IN THE | | | WIND-BORNE DEBRIS REGION AS DEFINED IN THE FLORIDA | | | BUILDING CODE, BUILDING AND THAT HAS AN INSURED VALUE | | | OF $300,000 OR MORE OR, IF THE BUILDING IS UNINSURED OR | | | FOR WHICH DOCUMENTATION OF INSURED VALUE IS NOT | | | PRESENTED, HAS A JUST VALUATION FOR THE STRUCTURE FOR | | | PURPOSES OF AD VALOREM TAXATION OF $300,000 OR MORE: | | | (A)ROOF TO WALL CONNECTIONS SHALL BE IMPROVED AS | | | REQUIRED BY SECTION 706.8.1. | | | (B)MANDATED RETROFITS OF THE ROOF-TO-WALL CONNECTION | | | SHALL NOT BE REQUIRED BEYOND A 15 PERCENT INCREASE IN | | | THE COST OF REROOFING. | | | 3) PLEASE SHOW THE ROOF WIND DESIGN PRESSURES ON THE | | | DRAWING. (ZONES ARE SHOWN BUT THE PRESSURES ARE NOT). | | | 4) PLEASE SHOW THE ROOF SLOPES. | | | 5) MIAMI DADE NOA 19-0311.04 IS A ROOFING SYSTEM - NOT | | | AN UNDERLAYMENT - IS THERE A FLAT ROOF TO BE REROOFED? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-10-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-02 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-02 |
Time |
07:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-09-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-09-18 |
Time |
17:43 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-18 |
Time |
17:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2020-10-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-10-09 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-10-09 |
Time |
13:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2020-10-02 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-10-02 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-10-02 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2020-10-02 09:06:26 | 10/02/20 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-09-21 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-09-21 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-09-21 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2020-09-21 16:33:59 | 09/21/20 1ST GAS REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. A SUB GAS PERMIT IS REQUIRED BY A LICENSED | | | CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS | | | TO THE FBC SEC. 105.1. | | | | | | 2. NOTE: THE CITY OF WEST PALM BEACH HAS NO RECORD OF | | | EXISTING TIKI TORCH. PLEASE PROVIDE ALL MANUFACTURES | | | SPECIFICATION FOR TIKI, GRILL (ONLY BTU'S), NEW RANGE, | | | NEW CLOTHING DRYER, POOL HEATER (ONLY BTU'S), AND NEW | | | OUTSIDE HEATER EQUIPMENT TO VERIFY COMPLIANCE WITH 2017 | | | FBC RES. SEC. G2408.1. | | | | | | 3. GAS APPLIANCES SHALL BE LISTED AND LABELED. THE | | | INSTALLATION MANUALS FOR ALL GAS APPLIANCES/EQUIPMENT | | | SHALL BE ONSITE AT THE TIME OF INSPECTION BUT IT SHALL | | | BE SUBMITTED FOR REVIEW AND COMPLIANCE PER THE 2017 FBC | | | RES. SEC. G2413.2 AND G2404.3. | | | | | | 4. SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION PER THE 2017 FBC RES. SEC. G2421.1. | | | | | | 5. PLEASE LABEL THE SHUTOFF VALVE ON GAS ISOMERIC PER | | | THE 2017 FBC RES. SEC. G2401.1.3. | | | | | | 6. PLEASE LABEL DRIP LEG ON EQUIPMENT INSTALLED, EXCEPT | | | FOR APPLIANCES, RANGE, DRYERS & OD GRILLS PER THE 2017 | | | FBC RES. SEC. G2419.2. | | | | | | 7. LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE EXISTING SYSTEM IN LEGEND TYPE MATER | | | WITH TOTAL. REFER TO THE 2017 FBC RES. SEC. G2413. | | | | | | 8. SUBMIT CALCULATIONS FOR COMBUSTION AIR (CLOTHES | | | DRYERS AND RANGE) PER THE 2017 FBC RES. SEC. G2407.1 | | | AND G2439.4. | | | | | | 9. IF USING METAL LOUVERS, SHOW THE LOCATION OF THE | | | METAL LOUVERS THAT ARE BEING INSTALLED FOR THE | | | COMBUSTION AIR. THE LOUVERS CANNOT BE LOCATED ON AN | | | EXTERIOR WALL THAT IS FIRE RATED AS THE FIRE RATING OF | | | THE WALL MUST BE MAINTAINED PER THE WPB AMENDMENTS TO | | | FBC SEC.107.2.1. | | | | | | 10. IF GAS UNITS REQUIRE CONDENSATE AND IT NEEDS TO BE | | | 1' AWAY FROM STRUCTURE PER THE 2017 FBC SEC R318.5. | | | | | | 11. PLEASE SHOW ON HOUSE PLANS THE LOCATION OF THE | | | TANK-LESS WATER HEATER AND DISTANCE OF ANY OPERABLE | | | DOORS OR WINDOWS IN RELATION TO THE WATER HEATER. THE | | | LOCATION OF THE WATER HEATER SHALL COMPLY WITH THE | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-10-06 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-10-06 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-10-01 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-09-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-23 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-16 |
Time |
16:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2020-10-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-10-02 |
Time |
06:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-10-02 |
Time |
06:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2020-09-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-18 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-18 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2020-09-18 12:52:40 | NO MECHANICAL WORK TO BE DONE WITH THIS PROJECT. ONE | | | BATH EXHAUST FAN BEING INSTALLED IN THE NEWLY | | | CONFIGURED MASTER BATH. ELECTRICAL INSPECTOR TO CHECK | | | THE DUCT WORK FOR THIS EXHAUST FAN. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-09-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-18 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-18 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2020-09-18 08:21:20 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20070724 | | | | | | CODES IN EFFECT: | | | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE SCOPE OF WORK FOR THE MECHANICAL | | | SYSTEM. FBC FS 107.2.1 | | | | | | 2) PLEASE PROVIDE MECHANICAL DRAWING SHOWING THE | | | EXHAUST FAN IN THE NEW MASTER BATHROOM. FBC RES TABLE | | | M1507.4 | | | | | | 3) PLEASE SECURE A MECHANICAL SUB-PERMIT. FBC FS | | | 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-10-02 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-10-02 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-10-02 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2020-10-02 11:55:27 | 10/20/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-09-21 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-09-21 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-09-21 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2020-09-21 15:53:46 | 09/21/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. A SUB PLUMBING PERMIT IS REQUIRED BY A LICENSED | | | CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS | | | TO THE FBC SEC. 105.1. | | | | | | 2. PLEASE PROVIDE A SHOWER DETAIL, OR PLACE A NOTE: | | | SHOWER PAN MUST HAVE A SLOPED MORTAR BED THAT IS | | | PRE-PITCHED BENEATH BEFORE LINER INSTALLATION OF 1/4" | | | IN PER FOOT TOWARD THE DRAIN, MUST HAVE A DAM CORNER, | | | BACKING AROUND THE PERIMETER AND BEFORE THE FINAL | | | MORTAR APPLICATION PLACE SOME PEA GRAVEL OVER WEEP | | | HOLES SO THE MORTAR DOES NOT COVER THEM PER | | | MANUFACTURES SPECIFICATIONS. | | | | | | 3. A STEAM IS SHOWN UP IN THE AIR ON ISOMETRIC BUT ON | | | THE ELECTRIC PAGE, IT SAYS IT'S UNDER THE SEAT, PLEASE | | | CLARIFY ON ISOMETRIC AND PLEASE PROVIDE MANUFACTURE | | | SPECIFICATION. IF THE STEAM UNIT IS UNDER A SHOWER | | | SEAT, HOW IS THE STEAM ENTERING THE SHOWER? PLEASE | | | CLARIFY WHAT TYPE OF PROTECTION IS BEING USED AND SHOW | | | WHERE IT GOING IN THE SHOWER. WPB AMENDMENTS TO THE FBC | | | 107.2.1A-2. | | | | | | 4. PLEASE SHOW HOW OR NOTE HOW THE DRAIN FOR THE STEAM | | | UNIT IS GOING TO BE PROTECTED FROM RODENT INFILTRATION | | | PER THE 2017 FBC SEC. R 2606.1. | | | | | | 5. THE WATER HEATER IS OUTSIDE AND REQUIRES HOT WATER | | | PIPES THAT ARE NOT IN A CONDITIONED SPACE TO BE | | | INSULATED WITH A MINIMUM R-3 PER THE 2017 FBC SEC. RE | | | 403.5.3. | | | | | | 6. SUBMIT A SLAB REPAIR DETAIL AND SHOW THE WIDTH OF | | | THE REPAIR, THE MINIMUM THICKNESS OF THE CONCRETE TO BE | | | REPLACED, AND THE PSI OF THE CONCRETE. SHOW THE SIZE | | | AND LENGTH OF THE DOWELS, THE MINIMUM EMBODIMENT DEPTH | | | INTO THE EXISTING SLAB, THE ANCHORING MATERIAL FOR THE | | | DOWELS, AND THE SPACING OF THE DOWELS ON CENTER. THE | | | REPAIR SHALL ALSO INCLUDE TERMITE TREATMENT OF THE SOIL | | | AND THE REQUIRED VAPOR BARRIER OVER WELL-COMPACTED | | | SOIL. A COPY OF THE TERMITE CERTIFICATE SHALL BE ONSITE | | | FOR A FINAL INSPECTION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2020-10-06 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2020-10-06 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2020-10-06 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2020-10-06 12:52:29 | PRIVATE PROVIDER APPROVED WITH PROVISO | | | | | | THE PLAN REVIEW AFFIDAVIT FOR PAGES REVIEWED NEEDS TO | | | STATE PAGE DATE/REVISION DATE FOR THE PAGES REVIEWED. | | | AFFIDAVIT SUBMITTED REFERENCES THE DATE THE DESIGNER | | | SIGNED AND SEALED THE DOCUMENT NOT THE DATE OF THE | | | DOCUMENT. PLEASE SUBMIT PRIOR TO FIRST INSPECTIONS | | | | | | RICHARD GATHRIGHT | | | 561 805 6679 |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2020-09-18 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2020-09-18 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2020-09-18 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2020-09-18 17:06:17 | REVIEW OF THE NOTICE TO BUILDING OFFICIAL AND INSURANCE | | | FOR PLAN REVIEW AND INSPECTIONS ONLY. | | | AFFIDAVITS OF PLAN REVIEW NOT COMPLETED AT THIS TIME. | | | AFFIDAVITS MAY NEED CORRECTION BASED ON PLAN REVIEW | | | AUDIT | | | | | | RICHARD GATHRIGHT | | | 561 805 6679 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2020-10-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-05 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-05 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-09-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-23 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-23 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2020-09-23 09:18:52 | SEE BUILDING REVIEW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-10-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-05 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-05 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|