Plan Review Details - Permit 20070508
Plan Review Stops For Permit 20070508
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-06 Cont ID  
Sent By rmcphers Date 2020-08-06 Time 08:28 Rev Time 0.00
Received By rmcphers Date 2020-08-06 Time 07:55 Sent To  
Notes
2020-08-06 08:25:45TEMPORARY TRAILER
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 AND (102.2
 (E))
 1) PLEASE SHOW THE USE (OCCUPANCY TYPE) PER FBC CHAPTER
 3. (PLEASE BE SPECIFIC AS TO THE USE, SUCH AS OFFICE OR
 HOSPITAL) MAY NOT BE A COMPLETE LIST OF REQUIREMENTS -
 PLAN REVIEW IS BASED ON THE BUILDING USE (OCCUPANCY
 TYPE).
 2) PLEASE PROVIDE SIGNED AND SEALED SUPPORT AND TIE
 DOWN DETAILS FROM AN ARCHITECT OR ENGINEER - SHOW THE
 WIND DESIGN DATA USED (WIND SPEED, RISK CATEGORY, ETC.)
 FBC 1609
 3) PLEASE SHOW ALL ACCESSIBILITY ELEMENTS TO COMPLY
 WITH FBC ACCESSIBILITY CODE.
 4) PLEASE PROVIDE A COMPLETED BUILDING PERMIT
 APPLICATION FROM A CONTRACTOR LICENSED TO INSTALL THE
 TRAILER.
 5) PLEASE PROVIDE A SIGNED AND SEALED SURVEY SHOWING
 TRAILER SETBACKS, FLOOD ZONES PER THE LATEST FIRM AND
 THE FINISHED FLOOR ELEVATION OF THE TRAILER.
  
 FYI = SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO
 BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR -
 IF YOUR ENGINEER OR ARCHITECT DOES NOT HAVE AN
 ELECTRONIC OR DIGITAL SIGNATURE - PLEASE DROP OFF (CITY
 HALL DROP BOX) THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS ALONG WITH A "PLAN REVIEW REQUEST
 FORM" EXPLAINING THE REASON FOR SUBMITTING THE DOCUMENT
 OR DRAWINGS. PLAN REVIEW REQUEST FORM CAN BE OBTAINED
 BY E MAILING [email protected] AND ASKING FOR THE FORM
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-08-05 Cont ID  
Sent By jleahy Date 2020-08-05 Time 08:04 Rev Time 0.00
Received By jleahy Date 2020-08-04 Time 16:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-18 Cont ID  
Sent By lmarchan Date 2020-08-18 Time 16:20 Rev Time 0.00
Received By lmarchan Date 2020-07-14 Time 10:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-08-07 Cont ID  
Sent By jesmith Date 2020-08-07 Time 10:51 Rev Time 0.00
Received By jesmith Date 2020-08-07 Time 09:33 Sent To  
Notes
2020-08-07 10:48:45CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
  
 20070508 1309 N FLAGLER DR
  
 1. PER WPB FBC 107.2.1, PROVIDE OCCUPANCY TYPE IN
 ACCORDANCE WITH FBC CHAPTER 3 AND SECTION 1004.
  
 2. PER WPB FBC 107.2.1, PROVIDE PLUMBING FIXTURE
 SCHEDULE TO COMPLY WITH FBC PL SECTION 403.1 AND
 APPLICABLE FBC ACC (ACCESSIBILITY REQUIREMENTS) AND
 SHOW ON PLAN. PLEASE NOTE, DEPENDING UPON THE
 OCCUPANCY, EXISTING FACILITIES MAY MEET THE
 REQUIREMENTS, IN WHICH CASE AN ACCESSIBLE ROUTE SHOWN
 ON THE PLANS (TO INCLUDE DISTANCE) TO THE EXISTING
 FACILITIES (TO BE SHOWN ON PLAN) SHALL BE PROVIDED.
 PLEASE REVIEW FBC PL 403.3 THROUGH 403.5 AND SECTION
 404.
  
 3. PROVIDE SANITARY AND WATER RISER DIAGRAMS AND
 CONNECTIONS TO UTILITIES. A BACKFLOW PREVENTER IS
 REQUIRED FOR THE WATER SERVICE TO COMPLY WITH FBC PL
 SECTION 608 AND WPB CCCM.
 SHOW LOCATION AND IDENTIFY THE BACKFLOW DEVICE ON THE
 PLANS.
 IF PORTABLE TANK FOR RETENTION OF SEWAGE IS PROVIDED,
 SHOW CAPACITY AND LOCATION.
  
 A COMPREHENSIVE REVIEW COULD NOT BE ACCOMPLISHED AT
 THIS TIME. PLEASE RESUBMIT CLEARLY LEGIBLE PLANS AND A
 RESPONSE NARRATIVE ADDRESSING THE PLUMBING COMMENTS
 FROM THE FIRST REVIEW.
  
  
 END OF COMMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 FYI = SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO
 BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR -
 IF YOUR ENGINEER OR ARCHITECT DOES NOT HAVE AN
 ELECTRONIC OR DIGITAL SIGNATURE - PLEASE DROP OFF (CITY
 HALL DROP BOX) THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS ALONG WITH A "PLAN REVIEW REQUEST
 FORM" EXPLAINING THE REASON FOR SUBMITTING THE DOCUMENT
 OR DRAWINGS. PLAN REVIEW REQUEST FORM CAN BE OBTAINED
 BY E MAILING [email protected] AND ASKING FOR THE FORM
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-246-0882 MOBILE
  
 20070508 1309 N FLAGLER DR
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-08-06 Cont ID  
Sent By rmcphers Date 2020-08-06 Time 08:30 Rev Time 0.00
Received By rmcphers Date 2020-08-06 Time 08:30 Sent To  
Notes
2020-08-06 08:30:41SEE BUILDING PLAN REVIEW

Review Stop Z ZONING
Rev No 1 Status F Date 2020-08-18 Cont ID  
Sent By eschneid Date 2020-08-18 Time 13:25 Rev Time 0.25
Received By eschneid Date 2020-08-18 Time 13:25 Sent To  
Notes
2020-08-18 13:36:16FAILED
  
 1) PROVIDE A SURVEY SHOWING THE LOCATION OF THE TRAILER
 WITH THE SURROUNDING FEATURES.
  
 2) PROVIDE THE FLOOR PLAN AND SPECIFICATIONS, TO
 INCLUDE THE SPECIFIC USE, FOR THE TRAILER.
  
 3) THE ADDITION OF ADDITIONAL SQUARE FOOTAGE ON THE
 SITE REQUIRES THE APPROVAL OF A ZONING REVIEW PRIOR TO
 APPROVAL OF THE BUILDING PERMIT. THE SIZE OF THE
 TRAILER AND ITS USE WILL DETERMINE WHAT THE APPROVAL
 PROCESS WILL BE.
  
 4) THE TRAILER IS A STRUCTURE THAT NEEDS TO CONFORM TO
 THE ZONING SETBACK, LANDSCAPE, ETC. REQUIREMENTS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]