| Plan Review Stops For Permit 20070444 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-08-19 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-08-19 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-07-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-07-14 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-07-14 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2020-07-14 10:32:20 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. REVISION: 20070444 | | | W. P. B. PERMIT: 19021186 | | | ADD: 3200 N. MILITARY TRL. | | | CONT: KAST | | | TEL: 561-568-8045 / CONTACT: MIKE SANCHEZ | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. JULY 14TH/ 2020 | | | ACTION: DENIED | | | | | | 1) SHEET A0.1 CODE REVIEW INDICATES THIS BUILDING IS A | | | TYPE 2A CONSTRUCTION. THE STRUCTURAL ELEMENTS STATE | | | THAT ALL COLUMNS, BEAMS AND ROOF TRUSSES/ BAR JOIST ARE | | | TO BE 1 HOUR PROTECTED. SHEET A6.0 SHOWS THE USE OF | | | METAL TRUSSES BUT NO MENTION OF A FIRE RATING. 2017 | | | FBC-B TABLE 601 ROOF CONSTRUCTION AND ASSOCIATED | | | SECONDARY MEMBERS. THERE ARE OTHER SIMILAR DETAILS ON | | | OTHER SHEETS WITH THE SAME CODE ISSUE. | | | | | | 2) SHEET A6.0 DETAIL 16 ALSO SHOWS PLYWOOD SHEATHING | | | SANDWICHED BETWEEN THE METAL B DECKING. AND THE SPANISH | | | STYLE CERAMIC ROOF TILES. IN THE S SHEETS THERE IS | | | SIMILAR DETAILS SHEET S6,2 DETAIL 22 THAT SHOWS THE USE | | | OF 5/8 INCH PLYWOOD SHEATHING. IN THE 2017 FBC-B | | | SECTION 603.1.1.1.3 DOES ALLOW THE USE OF FIRE | | | RETARDANT TREATED PLYWOOD FOR ROOF DECKING. SECTION | | | 718.5 ALSO CONFIRMS WHAT COMBUSTIBLE MATERIALS CAN BE | | | USED IN CONCEALED SPACES. SEE EXCEPTION 1 ALLOWING | | | COMBUSTIBLE MATERIALS IN CONCEALED SPACES IN ACCORDANCE | | | WITH SECTION 603 OF THE 2017 FBC-B. THERE ARE OTHER | | | SIMILAR DETAILS ON OTHER SHEETS WITH THE SAME CODE | | | ISSUE. | | | | | | | | | | | | 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 IF YOU | | | WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-07-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-22 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-22 |
Time |
12:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-08-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-08-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-08-13 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2020-07-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-07-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-07-13 |
Time |
14:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2020-09-23 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-09-23 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-09-23 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2020-09-23 15:28:04 | 09/23/20 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2020-08-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-08-21 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-08-21 |
Time |
06:52 |
Sent To |
|
|
| Notes |
| 2020-08-21 13:00:32 | 1) IF COMBUSTION AIR IS BEING PROVIDED BY THE | | | BUILDING'S MECHANICAL VENTILATION SYSTEM,THE SYSTEM | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR. FBC-FUEL GAS | | | SEC. 304.9.3. PROVIDE THIS INFORMATION FOR REVIEW. THE | | | PLAN NOTES THAT AHU -5 & AHU-1 IS SUPPLYING COMBUSTION | | | AIR FOR THE DRYERS. IS THIS UNIT DEDICATED TO SUPPLY | | | JUST THE COMBUSTION AIR FOR THE DRYERS? SHOW COMPLIANCE | | | WITH FBC-FUEL GAS SEC. 304.9.2. | | | 2) EACH OF THE APPLIANCES SERVED SHALL BE INTERLOCKED | | | WITH THE MECHANICAL AIR SUPPLY SYSTEM TO PREVENT MAIN | | | BURNER OPERATION OPERATION WHEN THE MECHANICAL AIR | | | SUPPLY SYSTEM IS NOT IN OPERATION. FBC-FUEL GAS | | | SEC.304.9.2. | | | 3) WHERE CONNECTED TO RIGID PIPING, A UNION SHALL BE | | | INSTALLED WITHIN ONE FOOT OF EITHER SIDE OF THE | | | PRESSURE REGULATOR. FBC-FUEL GAS SEC.410.2 (7). A UNION | | | WAS PLACED ON THE UTILITY SIDE OF THE GAS METER WHICH | | | FALLS UNDER THE GAS UTILITY WHICH WAS NOT IN MY REVIEW | | | COMMENT AND NO UNIONS ARE SHOWN AT THE REGULATORS AS | | | PREVIOUSLY REQUESTED. 2ND REQUEST. | | | | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-08-04 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-08-04 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2020-08-04 08:49:36 | 1) ACCORDING TO MY CALCULATIONS, THE BTU LOAD FOR THE | | | GAS SYSTEM IS 2,775,000 BTU'S. REVISE THE BTU LOAD ON | | | SHT. P4.7. | | | 2) WHERE CONNECTED TO RIGID PIPING, A UNION SHALL BE | | | INSTALLED WITHIN ONE FOOT OF EITHER SIDE OF THE | | | PRESSURE REGULATOR. FBC-FUEL GAS SEC.410.2 (7). | | | 3) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE ADDED | | | DRYER.FBC-FUEL GAS SEC.304.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-09-23 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-09-23 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-09-21 |
Time |
07:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-08-25 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-08-25 |
Time |
06:55 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-08-12 |
Time |
07:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-08-04 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-07-10 |
Time |
15:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-09-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-22 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-22 |
Time |
12:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2020-07-17 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-07-17 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-17 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2020-09-23 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-09-23 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-09-23 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2020-09-23 15:28:57 | 09/23/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-08-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-08-21 |
Time |
06:51 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-08-21 |
Time |
06:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-08-04 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-07-30 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2020-07-31 06:56:59 | 1) SHT. A7.4 - DETAILS #23 & #19 - THE KNEE CLEARANCE | | | SHALL BE 8 INCHES DEEP MINIMUM AT 27 INCHES ABOVE THE | | | FINISH FLOOR OR GROUND PER FBC-ACCESS. SEC.306.3.3 AND | | | FIGURE 306.3. THE PLAN SHOWS 6 INCHES. | | | 2) SHT. A7.4 - DETAILS #10, #14, & #21 - THE MINIMUM | | | HEIGHT OF THE GRAB BAR IS SHOWN AS 2 FEET 8 INCHES. THE | | | MINIMUM HEIGHT IS 33 INCHES ( 2 FEET 9 INCHES) PER | | | FBC-ACCESS. SEC. 609.4. | | | 3) MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS | | | SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE | | | REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH | | | FLOOR OR GROUND. FBC-ACCESS. SEC.603.3. | | | 4) SHT. P3.1 - SHOW THE CONTINUATION POINT OF THE 3/4 | | | INCH GAS LINE. WPB AMEND. TO FBC SEC. 107.2.1. | | | 5) SUBMIT A REVISED WATER AND SANITARY RISER SHOWING | | | THE ADDED TUB IN THE GROOMING ROOM.WPB AMEND. TO FBC | | | SEC. 107.3.5.1.3. | | | 6) THE HOT WATER SUPPLIED TO BATHTUBS SHALL BE LIMITED | | | TO A MAXIMUM TEMPERATURE OF 120 DEGREES BY A WATER | | | -TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE 1070 | | | OR CSA B125.3 PER FBC-PLUMBING SEC.424.5. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-09-23 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-09-23 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-09-23 |
Time |
15:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-08-25 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-08-25 |
Time |
04:18 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-08-25 |
Time |
04:16 |
Sent To |
|
|
| Notes |
| 2020-08-25 04:16:57 | SIGNATURE AND SEAL REQUIRED ON SHT. SP-1. | | | COULD NOT VERIFY SIGNATURE ON SHEETS A1.2 & A9.0. | | | T.LARGE 8/25/2020. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-07-17 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-20 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2020-07-20 10:36:35 | SIGNATURE AND SEAL NOT REQUIRED ON SP-1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | 2020-07-17 14:34:04 | DESIGNER MUST SIGN AND SEAL SHEET SP-1. FBC FS 471 | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-08-03 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-08-03 |
Time |
12:03 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2020-08-03 |
Time |
12:03 |
Sent To |
|
|
| Notes |
|
|