|
 |
 |
 |
 |
 |
Plan Review Details - Permit 20070426
| Plan Review Stops For Permit 20070426 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-28 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-28 |
Time |
11:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-15 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-15 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2020-07-15 16:16:59 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE RAS 117 CALCULATIONS FROM THE ENGINEER DO NOT | | | SPECIFY THE SYSTEM TYPE OR THE PAGE NUMBER FROM THE NOA | | | TO INDICATE WHICH TESTED ASSEMBLY HE BASED HIS | | | CALCULATIONS ON. I DID NOT FIND ONE WITH FASTENER | | | SPACINGS OF 4"O.C. AT THE LAP AND THREE ROWS 8"O.C. IN | | | THE FILED. FBC 107.2.1 | | | | | | 2) RAS 117 SECTION 8.1 STATES THAT THE MINIMUM FASTENER | | | SEPARATION SHALL NOT BE LESS THAN 4"O.C.. THEREFORE, | | | THE 3" O.C. IN THE ENGINEER'S CALCULATIONS CAN NOT BE | | | USED. ADDITIONAL ROWS OF FASTENERS WILL BE REQUIRED. | | | SUBMIT CORRECTED CALCULATIONS. | | | | | | 3) CIRCLE OR HI-LIGHT THE SYSTEM, FASTENING OPTION AND | | | DESIGN PRESSURE FOR THE PROPOSED ROOF COVERING ASSEMBLY | | | ON THE PRODUCT APPROVAL. FBC 107 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-28 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-21 |
Time |
16:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-15 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-10 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-28 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-28 |
Time |
11:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-15 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-15 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2020-07-15 15:50:58 | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | | THE ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE | | | THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER | | | VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE | | | BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | | ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS | | | REQUIRED TO BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER | | | FACIMILES OF THE SIGNATURE ARE ACCEPTABLE. FS 471 & | | | 61G15 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |