| Plan Review Stops For Permit 20070355 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-09-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-09-04 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-09-04 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-09-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-09-04 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-09-04 |
Time |
07:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-08-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-08-07 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-08-07 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2020-08-07 11:44:26 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | NOTE: THIS STRUCTURE IS CONSIDERED A THRESHOLD BUILDING | | | PER FS 553.71 12) ?THRESHOLD BUILDING? MEANS ANY | | | BUILDING WHICH IS GREATER THAN THREE STORIES OR 50 FEET | | | IN HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPANCY | | | CLASSIFICATION AS DEFINED IN THE FLORIDA BUILDING CODE | | | WHICH EXCEEDS 5,000 SQUARE FEET IN AREA AND AN OCCUPANT | | | CONTENT OF GREATER THAN 500 PERSONS. | | | | | | 1) ANY REPAIRS TO THRESHOLD BUILDINGS ARE REQUIRED TO | | | COMPLY WITH FS 553.79. THRESHOLD BLDG. REQUIRED | | | STATEMENT: W.P.B. AMENDMENT 110.8.4.4 ALL PLANS FOR THE | | | BUILDING WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY | | | THE ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S | | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE | | | FIRE-SAFETY STANDARDS AS DETERMINED BY THE LOCAL | | | AUTHORITY IN ACCORDANCE WITH THIS SECTION AND CHAPTER | | | 633 FLORIDA STATUTES. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-07-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-17 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-17 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2020-07-17 11:55:33 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE GENERAL NOTES ON SHEET G002 REFERENCE THE ICC | | | CODES AND THE 2012 IBC. THIS PROJECT IS GOVERNED BY THE | | | 2017 FLORIDA BUILDING CODES. FS 553.72 | | | | | | 2) THE PHASING LEGEND COLORS DO NOT MATCH THE LEVEL | | | PLANS. THE COLOR FOR PHASE 1B IN THE LEGEND IS PINK AND | | | IT IS BLUE ON THE LEVEL PLAN DRAWING. THE COLOR IN THE | | | LEGEND FOR PHASE 2A IS BLUE AND ON THE PLAN IT IS PINK. | | | IN ORDER TO AVOID CONFUSION, PLEASE CORRECT. FBC | | | 107.1.2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-09-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-09-04 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-09-04 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-09-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-09-04 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-09-01 |
Time |
14:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-08-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-08-07 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-24 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-07-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-17 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-17 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2020-09-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-09-01 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-09-01 |
Time |
17:49 |
Sent To |
|
|
| Notes |
| 2020-09-01 17:54:08 | 1) HARD COPIES: ENGINEER OF RECORD DRAWINGS (NINE | | | TOTAL) HAVE ORIGINAL SEAL/SIGNATURE. THEY MATCH | | | DRAWINGS UPLOADED TO PROJECTDOX. JG. | | | | | | 2) SPECIAL INSPECTOR AGREEMENT HAVE ORIGINAL | | | SEAL/SIGNATURE. JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-08-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-08-28 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-08-28 |
Time |
13:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-08-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-08-07 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-08-07 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2020-08-07 11:51:42 | THE FLORIDA LICENSED ENGINEER'S DIGITAL SIGNATURE ON | | | THE PLANS IS SELF CERTIFIED. THE FLORIDA BOARD OF | | | ENGINEER'S DOES NOT ALLOW ENGINEERS TO SELF CERTIFY | | | THEIR DIGITAL SIGNATURES. CONTACT THE FLORIDA BOARD OF | | | PROFESSIONAL ENGINEERS FOR INFORMATION. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-07-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-17 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-17 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2020-07-17 11:34:31 | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | | THE ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE | | | THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER | | | VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE | | | BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | | ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS | | | REQUIRED TO BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER | | | FACSIMILES OF THE SIGNATURE ARE ACCEPTABLE. FS 471 & | | | 61G15 |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
4 |
Status |
P |
Date |
2020-09-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-09-04 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-09-04 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
3 |
Status |
F |
Date |
2020-09-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-09-04 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-09-04 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2020-09-04 08:41:55 | THE CONTRACTOR AND OWNER FORMS IN THE THRESHOLD | | | DOCUMENTS HAVE NOT BEEN FILLED OUT WITH THE NOTARIZED | | | SIGNATURES OF THE CONTRACTOR AND THE OWNER. |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
F |
Date |
2020-08-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-08-07 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-08-07 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2020-08-07 12:22:14 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SINCE THIS PROJECT IS FOR STRUCTURE REPAIRS TO A | | | THRESHOLD BUILDING, THE COMPLETED THRESHOLD BUILDING | | | DOCUMENTS WILL BE REQUIRED. THE SPECIAL INSPECTOR | | | INFORMATION THAT WAS SUBMITTED IS INCOMPLETE. THE PE IS | | | REQUIRED TO BE LISTED WITH THE FLORIDA BOARD OF | | | ENGINEERS AS A SPECIAL INSPECTOR. THE DBPR BUILDING | | | INSPECTOR NUMBER LISTED ON THE DOCUMENTS FOR TIMOTHY | | | SHERWOOD, BN 71588 IS NOT CORRECT. THERE IS A TIMOTHY | | | SLADE SHERWOOD WITH NUMBER BN 4893 LISTED WITH DBPR. | | | PLEASE PROVIDE COPIES OF THE LICENSES AND | | | CERTIFICATIONS OF THE SPECIAL INSPECTOR AND ALL | | | DELEGATE INSPECTORS. | | | | | | 2) PLEASE CONTACT ME WITH AN EMAIL ADDRESS AND I WILL | | | BE HAPPY TO SEND YOU A COPY OF THE CURRENT (OCTOBER | | | 2018) GUIDELINES AND POLICIES FOR PROJECTS CONCERNING | | | THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS. | | | | | | 3) | | | A)THE THRESHOLD INSPECTION FORMS ARE REQUIRED TO BE | | | FILED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED AND | | | RETURNED TO THIS OFFICE, AND REVIEWED AND APPROVED | | | BEFORE PERMIT ISSUANCE WILL TAKE PLACE. | | | B) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME OF | | | INSPECTION EXPERIENCE ON PREVIOUS PROJECTS. THE RESUME | | | MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED | | | HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL | | | REVIEW THE RESUME. AFTER THE RESUME IS REVIEWED, AN | | | INTERVIEW MAY BE SCHEDULED WITH KEN CONRAD, CHIEF | | | BUILDING INSPECTOR. UNDER NO CIRCUMSTANCES WILL AN | | | INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST MEETING | | | THE ABOVE CRITERIA. | | | C) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY | | | FOR THIS TYPE OF CONSTRUCTION. | | | | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2020-07-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-17 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-17 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2020-07-17 11:30:18 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT THE REQUIRED SPECIAL INSPECTOR DOCUMENTS. A | | | SPECIAL INSPECTOR IS REQUIRED FOR THIS PROJECT AS | | | INDICATED ON SHEET G003 OF THE PLANS. CITY AMENDMENTS | | | FBC 110.3.9 OTHER INSPECTIONS SERVICES. THE BUILDING | | | OFFICIAL MAY MAKE, OR CAUSE TO BE MADE BY OTHERS, THE | | | INSPECTIONS REQUIRED BY SECTION 110. HE/SHE MAY ACCEPT | | | REPORTS OF INSPECTORS OF RECOGNIZED INSPECTION | | | SERVICES, PROVIDED THAT AFTER INVESTIGATION HE/SHE IS | | | SATISFIED AS TO THEIR QUALIFICATIONS AND RELIABILITY. A | | | CERTIFICATE CALLED FOR BY ANY PROVISION OF THE | | | TECHNICAL CODES SHALL NOT BE BASED ON SUCH REPORTS | | | UNLESS THE SAME ARE IN WRITING AND CERTIFIED BY A | | | RESPONSIBLE OFFICER OF SUCH SERVICE. THE BUILDING | | | OFFICIAL MAY REQUIRE THE | | | OWNER TO EMPLOY AN INSPECTION SERVICE IN THE FOLLOWING | | | INSTANCES: CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II | | | CONSTRUCTION | | | 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS | | | 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F 'C) IN EXCESS OF 3000 | | | POUNDS PER SQUARE INCH | | | 4. FOR PILE DRIVING | | | 5. FOR BUILDINGS WITH AREA GREATER THAN 20,000 SQUARE | | | FOOT | | | 6. FOR BUILDINGS MORE THAN 2 STORIES IN HEIGHT | | | 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR | | | METHODS OF CONSTRUCTION | | | SUCH INSPECTORS SHALL BE ADEQUATELY PRESENT AT TIMES | | | WORK IS UNDERWAY ON THE STRUCTURAL ELEMENTS OF THE | | | BUILDING. SUCH INSPECTORS SHALL BE A REGISTERED | | | ARCHITECT, OR ENGINEER, OR A PERSON LICENSED UNDER | | | CHAPTER 468, PART XII, FLORIDA STATUTES. SUCH | | | INSPECTORS SHALL SUBMIT WEEKLY PROGRESS REPORTS | | | INCLUDING THE DAILY INSPECTIONS TO THE BUILDING | | | OFFICIAL, AND INCLUDING A CODE COMPLIANCE OPINION OF | | | THE RESIDENT INSPECTOR. AT THE COMPLETION OF THE | | | CONSTRUCTION WORK OR PROJECT, SUCH INSPECTORS SHALL | | | SUBMIT A CERTIFICATE OF COMPLIANCE TO THE BUILDING | | | OFFICIAL, STATING THAT THE WORK WAS DONE IN COMPLIANCE | | | WITH THIS CODE AND IN ACCORDANCE WITH THE PERMITTED | | | DRAWING. FINAL INSPECTION SHALL BE MADE BY THE BUILDING | | | OFFICIAL BEFORE A CERTIFICATE OF OCCUPANCY OR | | | CERTIFICATE OF COMPLETION IS ISSUED; AND CONFIRMATION | | | INSPECTIONS MAY BE MADE AT ANY TIME TO MONITOR | | | ACTIVITIES AND RESIDENT INSPECTORS. | | | | | | 2) PLEASE CONTACT ME WITH AN EMAIL ADDRESS AND I WILL | | | BE HAPPY TO SEND YOU A COPY OF THE CURRENT (OCTOBER | | | 2018) GUIDELINES AND POLICIES FOR PROJECTS CONCERNING | | | THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS. |
|
|