| Plan Review Stops For Permit 20070327 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-21 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-21 |
Time |
08:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-10-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-21 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-21 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2020-10-21 13:23:34 | PAVING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | 2ND REVIEW - NO CHANGES SINCE LAST REVIEW | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE SHOW ACCESSIBLE PARKING SPACE SIZE TO COMPLY | | | WITH FBC ACCESSIBILITY 502.2 | | | 2) PLEASE SHOW ACCESSIBLE PARKING ACCESS AISLE SIZE AND | | | STRIPPING TO COMPLY WITH FBC ACCESSIBILITY 502.3 | | | 3) PLEASE RECONFIGURE THE ACCESSIBLE PARKING - THE | | | ACCESSIBLE PATH TO THE BUILDING OR SIDEWALK FROM THE | | | ACCESS AISLE CANNOT BE BEHIND ANOTHER VEHICLE - | | | FBC ACCESSIBILITY 502.3 ACCESS AISLE. | | | ACCESS AISLES SERVING PARKING SPACES SHALL COMPLY WITH | | | 502.3. ACCESS AISLES SHALL ADJOIN AN ACCESSIBLE ROUTE. | | | TWO PARKING SPACES SHALL BE PERMITTED TO SHARE A COMMON | | | ACCESS AISLE. | | | PARKING ACCESS AISLES MUST BE PART OF AN ACCESSIBLE | | | ROUTE TO THE BUILDING OR FACILITY ENTRANCE. ACCESS | | | AISLES MUST BE PLACED ADJACENT TO ACCESSIBLE PARKING | | | SPACES. ALL SPACES MUST BE LOCATED ON AN ACCESSIBLE | | | ROUTE THAT IS AT LEAST 44 INCHES (1118 MM) WIDE SO THAT | | | USERS ARE NOT COMPELLED TO WALK OR WHEEL BEHIND PARKED | | | VEHICLES EXCEPT BEHIND HIS OR HER OWN VEHICLE. | | | 4) SHOW GROUND TO BE LEVEL AT THE ACCESSIBLE PARKING | | | AND ACCESSIBLE AISLE - FBC A502.4FLOOR OR GROUND | | | SURFACES. | | | PARKING SPACES AND ACCESS AISLES SERVING THEM SHALL | | | COMPLY WITH 302. ACCESS AISLES SHALL BE AT THE SAME | | | LEVEL AS THE PARKING SPACES THEY SERVE. CHANGES IN | | | LEVEL ARE NOT PERMITTED. | | | EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE | | | PERMITTED. | | | 5) ONE ACCESSIBLE PARKING SPACE NEEDS TO BE VAN | | | ACCESSIBLE - FBC A208.2.4 VAN PARKING SPACES. | | | WHERE VAN PARKING IS PROVIDED PURSUANT TO SECTION | | | 502.2, FOR EVERY SIX OR FRACTION OF SIX PARKING SPACES | | | REQUIRED BY 208.2 TO COMPLY WITH 502, AT LEAST ONE | | | SHALL BE A VAN PARKING SPACE COMPLYING WITH 502. | | | 6) VAN ACCESSIBLE - ACCESS AISLE NEEDS TO BE ON THE | | | PASSENGER'S SIDE WHEN PARKING IS ANGLED - FBC A502.3.4 | | | LOCATION. | | | ACCESS AISLES SHALL NOT OVERLAP THE VEHICULAR WAY. | | | ACCESS AISLES SHALL BE PERMITTED TO BE PLACED ON EITHER | | | SIDE OF THE PARKING SPACE EXCEPT FOR ANGLED VAN PARKING | | | SPACES WHICH SHALL HAVE ACCESS AISLES LOCATED ON THE | | | PASSENGER SIDE OF THE PARKING SPACES. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-08-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-28 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-28 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2020-08-28 14:53:08 | PAVING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE SHOW ACCESSIBLE PARKING SPACE SIZE TO COMPLY | | | WITH FBC ACCESSIBILITY 502.2 | | | 2) PLEASE SHOW ACCESSIBLE PARKING ACCESS AISLE SIZE AND | | | STRIPPING TO COMPLY WITH FBC ACCESSIBILITY 502.3 | | | 3) PLEASE RECONFIGURE THE ACCESSIBLE PARKING - THE | | | ACCESSIBLE PATH TO THE BUILDING OR SIDEWALK FROM THE | | | ACCESS AISLE CANNOT BE BEHIND ANOTHER VEHICLE - | | | FBC ACCESSIBILITY 502.3 ACCESS AISLE. | | | ACCESS AISLES SERVING PARKING SPACES SHALL COMPLY WITH | | | 502.3. ACCESS AISLES SHALL ADJOIN AN ACCESSIBLE ROUTE. | | | TWO PARKING SPACES SHALL BE PERMITTED TO SHARE A COMMON | | | ACCESS AISLE. | | | PARKING ACCESS AISLES MUST BE PART OF AN ACCESSIBLE | | | ROUTE TO THE BUILDING OR FACILITY ENTRANCE. ACCESS | | | AISLES MUST BE PLACED ADJACENT TO ACCESSIBLE PARKING | | | SPACES. ALL SPACES MUST BE LOCATED ON AN ACCESSIBLE | | | ROUTE THAT IS AT LEAST 44 INCHES (1118 MM) WIDE SO THAT | | | USERS ARE NOT COMPELLED TO WALK OR WHEEL BEHIND PARKED | | | VEHICLES EXCEPT BEHIND HIS OR HER OWN VEHICLE. | | | 4) SHOW GROUND TO BE LEVEL AT THE ACCESSIBLE PARKING | | | AND ACCESSIBLE AISLE - FBC A502.4FLOOR OR GROUND | | | SURFACES. | | | PARKING SPACES AND ACCESS AISLES SERVING THEM SHALL | | | COMPLY WITH 302. ACCESS AISLES SHALL BE AT THE SAME | | | LEVEL AS THE PARKING SPACES THEY SERVE. CHANGES IN | | | LEVEL ARE NOT PERMITTED. | | | EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE | | | PERMITTED. | | | 5) ONE ACCESSIBLE PARKING SPACE NEEDS TO BE VAN | | | ACCESSIBLE - FBC A208.2.4 VAN PARKING SPACES. | | | WHERE VAN PARKING IS PROVIDED PURSUANT TO SECTION | | | 502.2, FOR EVERY SIX OR FRACTION OF SIX PARKING SPACES | | | REQUIRED BY 208.2 TO COMPLY WITH 502, AT LEAST ONE | | | SHALL BE A VAN PARKING SPACE COMPLYING WITH 502. | | | 6) VAN ACCESSIBLE - ACCESS AISLE NEEDS TO BE ON THE | | | PASSENGER?S SIDE WHEN PARKING IS ANGLED - FBC A502.3.4 | | | LOCATION. | | | ACCESS AISLES SHALL NOT OVERLAP THE VEHICULAR WAY. | | | ACCESS AISLES SHALL BE PERMITTED TO BE PLACED ON EITHER | | | SIDE OF THE PARKING SPACE EXCEPT FOR ANGLED VAN PARKING | | | SPACES WHICH SHALL HAVE ACCESS AISLES LOCATED ON THE | | | PASSENGER SIDE OF THE PARKING SPACES. | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-10-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2020-10-27 |
Time |
|
Sent To |
I |
|
| Notes |
| 2020-10-27 13:42:22 | PASSED WITH PROVISOS: | | | | | | CALL FOR LOCATES, DIAL 811 BEFORE YOU DIG. FOR MORE | | | INFO ON "CALL BEFORE YOU DIG", GO TO | | | HTTP://WWW.SUNSHINE811.COM (REF: UNDERGROUND FACILITY | | | DAMAGE PREVENTION AND SAFETY ACT, FLORIDA STATUTE, | | | CHAPTER 556.) | | | PLEASE ADDRESS OUTSTANDING BUILDING & ZONING COMMENTS. | | | | | | THANKS, | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR, WEST PALM BEACH, FL | | | 33401 | | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | | (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-08-19 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2020-08-19 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-08-19 16:20:05 | PLEASE ADDRESS ZONING COMMENTS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-09-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-09-03 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-06-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-24 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-05-25 |
Time |
12:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-11-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-11-10 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-10-13 |
Time |
14:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-08-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-28 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-23 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
N |
Date |
2021-09-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-09-07 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-09-07 |
Time |
12:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-21 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-21 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2021-06-21 08:59:04 | SIGNATURE REVIEW | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - | | | | | | DRAWING PROVIDED BY GLEN A. MILLER P.E. NEEDS TO BE | | | SIGNED AND SEALED. FBC WPB 107.1 | | | | | | FYI - DRAWINGS DO NOT SHOW AS ELECTRONICALLY SIGNED IN | | | ADOBE READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX | | | NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED BY THE | | | ENGINEER OR ARCHITECT TO BE USED IN ELECTRONIC PLAN | | | REVIEW. - OR - IF YOUR ARCHITECT OR ENGINEER DOES NOT | | | HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN DROP | | | OFF THE ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS | | | TO THE FRONT DESK IN THE BUILDING DIVISION AT THE CITY | | | HALL. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
N |
Date |
2020-10-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-21 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-21 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2020-08-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-28 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-28 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-06-22 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2021-06-22 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2021-06-22 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2021-06-22 13:57:40 | 1. PLEASE CONVERT ONE ADDITIONAL PARKING SPACE ALONG | | | DIXIE AS COMPACT PARKIGN AND MOVE THE SPACES 6" NORTH | | | TO AVOID ENCROACHMENT OF TEH PARKING SPACE INTO THE | | | SIDEWALK. | | | 2. AN IRRIGATION PERMIT WILL BE NEEDED FOR THE | | | INSTALLATION OF IRRIGATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2020-11-06 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2020-11-06 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2020-11-06 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2020-11-06 17:05:23 | 1. PARKING STALLS SHALL COMPLY WITH THE DIMENSIONS OF | | | THE STALLS AND DRIVE AISLES ACCORDING TO FIGURE XV-2 IN | | | SECTION 94-485 OF THE ZONING CODE. | | | 2. PLEASE INDICATE THE ANGLE OF THE PROPOSED PARKING TO | | | DETERMINE THE REQUIRED DIMENSIONS OF THE SPACES | | | ACCORDING TO FIGURE XV-2 IN SECTION 94-485 OF THE | | | ZONING CODE. | | | 3. PARKING STRIPING SHALL COMPLY WITH THE CITY'S STALL | | | PAINTING DETAIL. | | | 4. IF PLANT MATERIAL WITHIN EXISTING LANDSCAPE BUFFER | | | IS MISSING, IT SHALL BE RESTORED. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2020-07-30 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2020-07-30 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2020-07-30 10:45:19 | 1. TEH PROPOSED RESURFACING WILL REQUIRE THE PARKING | | | LOT TO BE BROUGHT INTO COMPLIANCE WITH CURRENT | | | LANDSCAPE AND STRIPING REGULATIONS. ALL PARKING SPACES | | | AND DRIVE AISLES SHALL COMPLY WITH CURRENT CODE FOR | | | DIMENSIONS AND STRIPING. A PARKING LAYOUT PLAN SHALL BE | | | SUBMITTED WITH ALL DIMENSIONS TO CONFIRM COMPLIANCE. | | | (SEC 94-111) | | | 2. A SEPARATE LANDSCAPE PERMIT WILL BE REQUIRED TO | | | CONFIRM COMPLIANCE WITH CURRENT CODE REQUIREMENTS FOR | | | SURFACE PARKING LOTS (SEC 94-113(F)). | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439 |
|
|