Plan Review Details - Permit 20070327
Plan Review Stops For Permit 20070327
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-06-21 Cont ID  
Sent By rmcphers Date 2021-06-21 Time 08:52 Rev Time 0.00
Received By rmcphers Date 2021-06-21 Time 08:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-10-21 Cont ID  
Sent By rmcphers Date 2020-10-21 Time 13:20 Rev Time 0.00
Received By rmcphers Date 2020-10-21 Time 13:20 Sent To  
Notes
2020-10-21 13:23:34PAVING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 2ND REVIEW - NO CHANGES SINCE LAST REVIEW
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW ACCESSIBLE PARKING SPACE SIZE TO COMPLY
 WITH FBC ACCESSIBILITY 502.2
 2) PLEASE SHOW ACCESSIBLE PARKING ACCESS AISLE SIZE AND
 STRIPPING TO COMPLY WITH FBC ACCESSIBILITY 502.3
 3) PLEASE RECONFIGURE THE ACCESSIBLE PARKING - THE
 ACCESSIBLE PATH TO THE BUILDING OR SIDEWALK FROM THE
 ACCESS AISLE CANNOT BE BEHIND ANOTHER VEHICLE -
 FBC ACCESSIBILITY 502.3 ACCESS AISLE.
 ACCESS AISLES SERVING PARKING SPACES SHALL COMPLY WITH
 502.3. ACCESS AISLES SHALL ADJOIN AN ACCESSIBLE ROUTE.
 TWO PARKING SPACES SHALL BE PERMITTED TO SHARE A COMMON
 ACCESS AISLE.
 PARKING ACCESS AISLES MUST BE PART OF AN ACCESSIBLE
 ROUTE TO THE BUILDING OR FACILITY ENTRANCE. ACCESS
 AISLES MUST BE PLACED ADJACENT TO ACCESSIBLE PARKING
 SPACES. ALL SPACES MUST BE LOCATED ON AN ACCESSIBLE
 ROUTE THAT IS AT LEAST 44 INCHES (1118 MM) WIDE SO THAT
 USERS ARE NOT COMPELLED TO WALK OR WHEEL BEHIND PARKED
 VEHICLES EXCEPT BEHIND HIS OR HER OWN VEHICLE.
 4) SHOW GROUND TO BE LEVEL AT THE ACCESSIBLE PARKING
 AND ACCESSIBLE AISLE - FBC A502.4FLOOR OR GROUND
 SURFACES.
 PARKING SPACES AND ACCESS AISLES SERVING THEM SHALL
 COMPLY WITH 302. ACCESS AISLES SHALL BE AT THE SAME
 LEVEL AS THE PARKING SPACES THEY SERVE. CHANGES IN
 LEVEL ARE NOT PERMITTED.
 EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE
 PERMITTED.
 5) ONE ACCESSIBLE PARKING SPACE NEEDS TO BE VAN
 ACCESSIBLE - FBC A208.2.4 VAN PARKING SPACES.
 WHERE VAN PARKING IS PROVIDED PURSUANT TO SECTION
 502.2, FOR EVERY SIX OR FRACTION OF SIX PARKING SPACES
 REQUIRED BY 208.2 TO COMPLY WITH 502, AT LEAST ONE
 SHALL BE A VAN PARKING SPACE COMPLYING WITH 502.
 6) VAN ACCESSIBLE - ACCESS AISLE NEEDS TO BE ON THE
 PASSENGER'S SIDE WHEN PARKING IS ANGLED - FBC A502.3.4
 LOCATION.
 ACCESS AISLES SHALL NOT OVERLAP THE VEHICULAR WAY.
 ACCESS AISLES SHALL BE PERMITTED TO BE PLACED ON EITHER
 SIDE OF THE PARKING SPACE EXCEPT FOR ANGLED VAN PARKING
 SPACES WHICH SHALL HAVE ACCESS AISLES LOCATED ON THE
 PASSENGER SIDE OF THE PARKING SPACES.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-28 Cont ID  
Sent By rmcphers Date 2020-08-28 Time 14:53 Rev Time 0.00
Received By rmcphers Date 2020-08-28 Time 14:19 Sent To  
Notes
2020-08-28 14:53:08PAVING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW ACCESSIBLE PARKING SPACE SIZE TO COMPLY
 WITH FBC ACCESSIBILITY 502.2
 2) PLEASE SHOW ACCESSIBLE PARKING ACCESS AISLE SIZE AND
 STRIPPING TO COMPLY WITH FBC ACCESSIBILITY 502.3
 3) PLEASE RECONFIGURE THE ACCESSIBLE PARKING - THE
 ACCESSIBLE PATH TO THE BUILDING OR SIDEWALK FROM THE
 ACCESS AISLE CANNOT BE BEHIND ANOTHER VEHICLE -
 FBC ACCESSIBILITY 502.3 ACCESS AISLE.
 ACCESS AISLES SERVING PARKING SPACES SHALL COMPLY WITH
 502.3. ACCESS AISLES SHALL ADJOIN AN ACCESSIBLE ROUTE.
 TWO PARKING SPACES SHALL BE PERMITTED TO SHARE A COMMON
 ACCESS AISLE.
 PARKING ACCESS AISLES MUST BE PART OF AN ACCESSIBLE
 ROUTE TO THE BUILDING OR FACILITY ENTRANCE. ACCESS
 AISLES MUST BE PLACED ADJACENT TO ACCESSIBLE PARKING
 SPACES. ALL SPACES MUST BE LOCATED ON AN ACCESSIBLE
 ROUTE THAT IS AT LEAST 44 INCHES (1118 MM) WIDE SO THAT
 USERS ARE NOT COMPELLED TO WALK OR WHEEL BEHIND PARKED
 VEHICLES EXCEPT BEHIND HIS OR HER OWN VEHICLE.
 4) SHOW GROUND TO BE LEVEL AT THE ACCESSIBLE PARKING
 AND ACCESSIBLE AISLE - FBC A502.4FLOOR OR GROUND
 SURFACES.
 PARKING SPACES AND ACCESS AISLES SERVING THEM SHALL
 COMPLY WITH 302. ACCESS AISLES SHALL BE AT THE SAME
 LEVEL AS THE PARKING SPACES THEY SERVE. CHANGES IN
 LEVEL ARE NOT PERMITTED.
 EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE
 PERMITTED.
 5) ONE ACCESSIBLE PARKING SPACE NEEDS TO BE VAN
 ACCESSIBLE - FBC A208.2.4 VAN PARKING SPACES.
 WHERE VAN PARKING IS PROVIDED PURSUANT TO SECTION
 502.2, FOR EVERY SIX OR FRACTION OF SIX PARKING SPACES
 REQUIRED BY 208.2 TO COMPLY WITH 502, AT LEAST ONE
 SHALL BE A VAN PARKING SPACE COMPLYING WITH 502.
 6) VAN ACCESSIBLE - ACCESS AISLE NEEDS TO BE ON THE
 PASSENGER?S SIDE WHEN PARKING IS ANGLED - FBC A502.3.4
 LOCATION.
 ACCESS AISLES SHALL NOT OVERLAP THE VEHICULAR WAY.
 ACCESS AISLES SHALL BE PERMITTED TO BE PLACED ON EITHER
 SIDE OF THE PARKING SPACE EXCEPT FOR ANGLED VAN PARKING
 SPACES WHICH SHALL HAVE ACCESS AISLES LOCATED ON THE
 PASSENGER SIDE OF THE PARKING SPACES.
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2020-10-27 Cont ID  
Sent By rrossano Date 2020-10-27 Time   Rev Time 0.00
Received By rrossano Date 2020-10-27 Time   Sent To I
Notes
2020-10-27 13:42:22PASSED WITH PROVISOS:
  
 CALL FOR LOCATES, DIAL 811 BEFORE YOU DIG. FOR MORE
 INFO ON "CALL BEFORE YOU DIG", GO TO
 HTTP://WWW.SUNSHINE811.COM (REF: UNDERGROUND FACILITY
 DAMAGE PREVENTION AND SAFETY ACT, FLORIDA STATUTE,
 CHAPTER 556.)
 PLEASE ADDRESS OUTSTANDING BUILDING & ZONING COMMENTS.
  
 THANKS,
 RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES
 DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR, WEST PALM BEACH, FL
 33401
 DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE:
 (561) 246-9525
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2020-08-19 Cont ID  
Sent By rrossano Date 2020-08-19 Time   Rev Time  
Received By rrossano Date 2020-08-19 Time   Sent To  
Notes
2020-08-19 16:20:05PLEASE ADDRESS ZONING COMMENTS.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2021-09-07 Time   Rev Time 0.00
Received By aoliver Date 2021-09-03 Time 13:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-06-24 Cont ID  
Sent By jleahy Date 2021-06-24 Time 10:12 Rev Time 0.00
Received By jleahy Date 2021-05-25 Time 12:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-11-10 Cont ID  
Sent By lmarchan Date 2020-11-10 Time 08:21 Rev Time 0.00
Received By lmarchan Date 2020-10-13 Time 14:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-28 Cont ID  
Sent By rmcphers Date 2020-08-28 Time 14:54 Rev Time 0.00
Received By rmcphers Date 2020-07-23 Time 15:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status N Date 2021-09-07 Cont ID  
Sent By ccole Date 2021-09-07 Time 12:46 Rev Time 0.00
Received By ccole Date 2021-09-07 Time 12:42 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2021-06-21 Cont ID  
Sent By rmcphers Date 2021-06-21 Time 08:52 Rev Time 0.00
Received By rmcphers Date 2021-06-21 Time 08:52 Sent To  
Notes
2021-06-21 08:59:04SIGNATURE REVIEW
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED -
  
 DRAWING PROVIDED BY GLEN A. MILLER P.E. NEEDS TO BE
 SIGNED AND SEALED. FBC WPB 107.1
  
 FYI - DRAWINGS DO NOT SHOW AS ELECTRONICALLY SIGNED IN
 ADOBE READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX
 NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED BY THE
 ENGINEER OR ARCHITECT TO BE USED IN ELECTRONIC PLAN
 REVIEW. - OR - IF YOUR ARCHITECT OR ENGINEER DOES NOT
 HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN DROP
 OFF THE ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS
 TO THE FRONT DESK IN THE BUILDING DIVISION AT THE CITY
 HALL.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2020-10-21 Cont ID  
Sent By rmcphers Date 2020-10-21 Time 13:23 Rev Time 0.00
Received By rmcphers Date 2020-10-21 Time 13:23 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-08-28 Cont ID  
Sent By rmcphers Date 2020-08-28 Time 14:54 Rev Time 0.00
Received By rmcphers Date 2020-08-28 Time 14:54 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2021-06-22 Cont ID  
Sent By aaponte Date 2021-06-22 Time 13:53 Rev Time 0.00
Received By aaponte Date 2021-06-22 Time 13:52 Sent To  
Notes
2021-06-22 13:57:401. PLEASE CONVERT ONE ADDITIONAL PARKING SPACE ALONG
 DIXIE AS COMPACT PARKIGN AND MOVE THE SPACES 6" NORTH
 TO AVOID ENCROACHMENT OF TEH PARKING SPACE INTO THE
 SIDEWALK.
 2. AN IRRIGATION PERMIT WILL BE NEEDED FOR THE
 INSTALLATION OF IRRIGATION.

Review Stop Z ZONING
Rev No 2 Status F Date 2020-11-06 Cont ID  
Sent By aaponte Date 2020-11-06 Time 16:57 Rev Time 0.00
Received By aaponte Date 2020-11-06 Time 16:57 Sent To  
Notes
2020-11-06 17:05:231. PARKING STALLS SHALL COMPLY WITH THE DIMENSIONS OF
 THE STALLS AND DRIVE AISLES ACCORDING TO FIGURE XV-2 IN
 SECTION 94-485 OF THE ZONING CODE.
 2. PLEASE INDICATE THE ANGLE OF THE PROPOSED PARKING TO
 DETERMINE THE REQUIRED DIMENSIONS OF THE SPACES
 ACCORDING TO FIGURE XV-2 IN SECTION 94-485 OF THE
 ZONING CODE.
 3. PARKING STRIPING SHALL COMPLY WITH THE CITY'S STALL
 PAINTING DETAIL.
 4. IF PLANT MATERIAL WITHIN EXISTING LANDSCAPE BUFFER
 IS MISSING, IT SHALL BE RESTORED.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.

Review Stop Z ZONING
Rev No 1 Status F Date 2020-07-30 Cont ID  
Sent By aaponte Date 2020-07-30 Time 10:38 Rev Time 0.00
Received By aaponte Date 2020-07-30 Time 10:38 Sent To  
Notes
2020-07-30 10:45:191. TEH PROPOSED RESURFACING WILL REQUIRE THE PARKING
 LOT TO BE BROUGHT INTO COMPLIANCE WITH CURRENT
 LANDSCAPE AND STRIPING REGULATIONS. ALL PARKING SPACES
 AND DRIVE AISLES SHALL COMPLY WITH CURRENT CODE FOR
 DIMENSIONS AND STRIPING. A PARKING LAYOUT PLAN SHALL BE
 SUBMITTED WITH ALL DIMENSIONS TO CONFIRM COMPLIANCE.
 (SEC 94-111)
 2. A SEPARATE LANDSCAPE PERMIT WILL BE REQUIRED TO
 CONFIRM COMPLIANCE WITH CURRENT CODE REQUIREMENTS FOR
 SURFACE PARKING LOTS (SEC 94-113(F)).
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439