Plan Review Details - Permit 20070284
Plan Review Stops For Permit 20070284
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-07-21 Cont ID  
Sent By ccole Date 2020-07-21 Time 07:47 Rev Time 0.00
Received By ccole Date 2020-07-21 Time 07:01 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-07-15 Cont ID  
Sent By ccole Date 2020-07-15 Time 10:32 Rev Time 0.00
Received By ccole Date 2020-07-15 Time 08:59 Sent To  
Notes
2020-07-15 10:34:101ST REVIEW FBC-2017 RES. FUEL GAS
 PERMIT- 20070284
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) GAS ISOMETRIC DRAWING:
 A) THE DRAWING IS INCOMPLETE. IN ORDER TO ENSURE A SAFE
 OPERATING SYSTEM, THE DRAWING MUST BE MODIFIED TO SHOW
 THE ENTIRE SYSTEM INCLUDING ALL BRANCH PIPES FROM THE
 METER TO THE MOST REMOTE OUTLET BEING SERVICE BY THE
 METER. EACH APPLIANCE BTUH LOAD SHALL BE INDICATED ON
 THE DRAWING AND LOCATIONS OF REGULATORS SHALL BE
 INDICATED- SECTIONS G2412.3 & G2412.4 FBC RES.
 B) PROVIDE THE TOTAL DEVELOPED LENGTH OF THE SYSTEM
 FROM THE METER TO THE MOST REMOTE OUTLET, AND BRANCH
 LENGTH SIZES- SECTIONS G2413.4.1, G2413.4.2 &
 G2413.4.3.
 C) PROVIDE DELIVERY PRESSURE TO THE GENERATOR FROM THE
 OUTLET OF THE REGULATOR- SECTION G2421.1, AND INDICATE
 THE MODEL NUMBER OF THE REGULATOR TO BE INSTALLED. THE
 SUBMITTED SPECS SHOW MANY DIFFERENT MODELS, PRESSURE
 RANGES, AND ORIFICE SIZES. PLEASE MARKUP THE SELECTED
 REGULATOR IN THE SPECS.
 D) CORRECT THE BTUH LOAD OF THE GENERATOR ON THE
 DRAWING- THE SUBMITTED SPECS INDICATE 790.000 BTUH FULL
 LOAD- G2413.2 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-07-21 Time   Rev Time 0.00
Received By lmarchan Date 2020-07-16 Time 16:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-07-15 Time   Rev Time 0.00
Received By lmarchan Date 2020-07-13 Time 10:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-07-21 Cont ID  
Sent By ccole Date 2020-07-21 Time 07:47 Rev Time 0.00
Received By ccole Date 2020-07-21 Time 07:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-07-15 Cont ID  
Sent By ccole Date 2020-07-15 Time 10:34 Rev Time 0.00
Received By ccole Date 2020-07-15 Time 08:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-07-15 Cont ID  
Sent By ccole Date 2020-07-15 Time 10:34 Rev Time 0.00
Received By ccole Date 2020-07-15 Time 08:59 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy