Plan Review Details - Permit 20070269
Plan Review Stops For Permit 20070269
Review Stop G GAS REVIEW
Rev No 3 Status P Date 2020-09-08 Cont ID  
Sent By ccole Date 2020-09-08 Time 09:31 Rev Time 0.00
Received By ccole Date 2020-09-08 Time 09:09 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-08-06 Cont ID  
Sent By ccole Date 2020-08-06 Time 14:13 Rev Time 0.00
Received By ccole Date 2020-08-06 Time 12:43 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-07-20 Cont ID  
Sent By ccole Date 2020-07-20 Time 12:45 Rev Time 0.00
Received By ccole Date 2020-07-20 Time 10:57 Sent To  
Notes
2020-07-20 12:45:411ST REVIEW FBC-2017 RES. FUEL GAS
 PERMIT-20070269
 7/20/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE GAS ISOMETRIC IS INCOMPLETE:
 A) PROVIDE THE BTUH LOAD OF THE BBQ GRILL- SECTIONS
 G2413.2 & G2413.3 FBC RES.
 B) PROVIDE THE TOTAL DEVELOPED LENGTH OF THE SYSTEM-
 G2413.4.1 & G2413.4.2.
 C) PROVIDE THE PIPE SIZING TABLE USED- G2413.4
  
 2) SITE PLAN: PROVIDE THE UG TANK CLEARANCE DISTANCES
 MEASUREMENTS TO THE HOUSE, DRIVEWAY, AND PROPERTY LINE-
 SEE TABLE 6.4.1.1 AND SECTION 6.8.6.1 NFPA 58. PLEASE
 NOTE THAT IF THE TANK IS LESS TANK 10 FT. FROM THE
 DRIVEWAY, THE SHELL FOR THE TANK SHALL BE 18 IN. ABOVE
 GRADE, AND VEHICULAR BARRIER PROTECTION WILL BE
 REQUIRED.
  
 3) THE ENGINEER WHO PREPARED THE TANK TIE-DOWN DETAILS
 SHALL PROVIDE AN ELECTRONIC SIGNATURE AND SEAL ON THE
 DOCUMENT- FL. STATUTE 471.025 & FLORIDA ADMINISTRATIVE
 CODE SEC. 61G15-23.005.
  
 4) PROVIDE SPECS FOR THE 2ND STAGE REGULATORS- G2421.1.
  
 5) PLEASE NOTE THAT SPECS INDICATING GAS PIPING
 REQUIREMENTS FOR THE GENERATOR, POOL HEATER, AND BBQ
 GRILL SHALL EITHER BE SUBMITTED NOW OR BE ONSITE AT
 TIME OF INSPECTIONS. THE SPECS SHALL SHOW BTUH LOADS
 AND REQUIRED INPUT PRESSURES IN WATER COLUMN.
  
 6) THE CONTRACTOR OR QUALIFIER WHO PREPARED THE GAS
 RISER DRAWING SHALL PROVIDE HIS/HER SIGNATURE ON IT-
 SECTION 107.2.1 WPB, AND FLORIDA STATUTES 471.003(2)(H)
 & 471.025.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2020-09-08 Time   Rev Time 0.00
Received By lmarchan Date 2020-09-04 Time 06:35 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-08-06 Time   Rev Time 0.00
Received By lmarchan Date 2020-08-05 Time 07:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-07-20 Time   Rev Time 0.00
Received By lmarchan Date 2020-07-08 Time 08:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status N Date 2020-09-08 Cont ID  
Sent By ccole Date 2020-09-08 Time 09:31 Rev Time 0.00
Received By ccole Date 2020-09-08 Time 09:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-08-06 Cont ID  
Sent By ccole Date 2020-08-06 Time 14:13 Rev Time 0.00
Received By lcrespo Date 2020-08-06 Time 12:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-07-20 Cont ID  
Sent By ccole Date 2020-07-20 Time 13:00 Rev Time 0.00
Received By ccole Date 2020-07-20 Time 10:57 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-09-08 Cont ID  
Sent By ccole Date 2020-09-08 Time 09:31 Rev Time 0.00
Received By ccole Date 2020-09-08 Time 09:09 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-08-06 Cont ID  
Sent By ccole Date 2020-08-06 Time 14:13 Rev Time 0.00
Received By ccole Date 2020-08-06 Time 14:13 Sent To  
Notes
2020-08-06 14:20:25THE ENGINEER SHALL PROVIDE AN ELECTRONIC SIGNATURE AND
 SEAL ON THE TANK TIE-DOWN DENGINEERING- FL. STATUTE
 471.025 & FLORIDA ADMINISTRATIVE CODE 61G15-23.005.
 THE SUBMITTED ENGINEERING HAS COPIED SIGNATURES AND
 SEALS. THE ENGINEER MAY PROVIDE A SIGNED AND SEALED
 HARD COPY OF THE DOCUMENT TO THE CONTRAXT WHICH MAY BE
 SUBMITTED TO THE BUILDING DEPARTMENT FOR PERMIT
 ISSUANCE. FOR MORE INFORAMTION PLEASE CONTACT
 [email protected] 561-805-6719.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-07-20 Cont ID  
Sent By ccole Date 2020-07-20 Time 13:00 Rev Time 0.00
Received By ccole Date 2020-07-20 Time 10:57 Sent To  
Notes
2020-07-20 13:03:49THE CONTRACTOR OR QUALIFIER WHO PREPARED THE DRAWING
 SHALL PROVIDE HIS/HER SIGNATURE ON IT- SECTION 107.2.1
 WPB, AND FLORIDA STATUTES 471.003(2)(H) & 471.025.
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved