Plan Review Details - Permit 20070263
Plan Review Stops For Permit 20070263
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-08-15 Cont ID  
Sent By cthroop Date 2020-08-15 Time 13:35 Rev Time 0.00
Received By cthroop Date 2020-08-15 Time 12:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-07-28 Cont ID  
Sent By cthroop Date 2020-07-28 Time 13:30 Rev Time 0.00
Received By cthroop Date 2020-07-28 Time 13:17 Sent To  
Notes
2020-07-28 13:31:57PLAN REVIEW GENERATOR - BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1) PROVIDE WIND DESIGN LOADS FOR THE GENERATOR PER FBC
 107.3.5.3 AND R301.2 AS REQUIRED FOR THE GENERATOR PAD
 ENGINEERING.
 2) STRUCTURAL DETAIL OF PAD AND DESIGN LOADS SHALL BE
 SIGNED AND SEALED BY A DESIGN PROFESSIONAL.
 3) PROVIDE STRUCTURAL DETAIL OF GENERATOR PAD.
 4) PROVIDE A SITE PLAN. SHOW LOCATION OF PROPOSED
 GENERATOR.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-08-15 Cont ID  
Sent By cthroop Date 2020-08-15 Time 13:35 Rev Time 0.00
Received By cthroop Date 2020-08-15 Time 12:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-07-28 Cont ID  
Sent By cthroop Date 2020-07-28 Time 13:28 Rev Time 0.00
Received By cthroop Date 2020-07-28 Time 13:17 Sent To  
Notes
2020-07-28 13:29:59PLAN REVIEW GENERATOR - ELECTRICAL
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 1) PROVIDE NEW LOAD CALCULATIONS.
 PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE EXISTING
 AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE IS
 ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2
  
  
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2020-07-28 Cont ID  
Sent By cthroop Date 2020-07-28 Time 13:27 Rev Time 0.00
Received By cthroop Date 2020-07-28 Time 13:17 Sent To  
Notes
2020-07-28 13:27:51A SEPERATE GAS PERMIT IS REQUIRED. CT

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-15 Cont ID  
Sent By cthroop Date 2020-08-15 Time 13:35 Rev Time 0.00
Received By cthroop Date 2020-07-29 Time 09:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-07-28 Cont ID  
Sent By cthroop Date 2020-07-28 Time 13:33 Rev Time 0.00
Received By cthroop Date 2020-07-10 Time 10:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-07-28 Cont ID  
Sent By cthroop Date 2020-07-28 Time 13:27 Rev Time 0.00
Received By cthroop Date 2020-07-28 Time 13:17 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-08-15 Cont ID  
Sent By cthroop Date 2020-08-15 Time 13:35 Rev Time 0.00
Received By cthroop Date 2020-08-15 Time 12:32 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-07-28 Cont ID  
Sent By cthroop Date 2020-07-28 Time 13:32 Rev Time 0.00
Received By cthroop Date 2020-07-28 Time 13:17 Sent To  
Notes
2020-07-28 13:33:08PLAN REVIEW GENERATOR - DIGITAL SIGNATURES AND SEALS
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1) THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON
 ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15
  
 2) DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH
 FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE
 NEXT REVIEW CYCLE REQUIRE REVIEW.
  
 3) UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT.
  
  
 4) FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY
 DIGITAL SIGATURES AND SEALS PER FS 668.003.
  
 NOTE: YOU MAY PROVIDE A PAPER PLAN WITH WET SIGNATURE
 AND SEAL PRIOR TO PERMIT.
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2020-08-05 Cont ID  
Sent By rthermid Date 2020-08-05 Time   Rev Time 0.00
Received By rthermid Date 2020-08-05 Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-07-20 Cont ID  
Sent By rthermid Date 2020-07-20 Time   Rev Time  
Received By rthermid Date 2020-07-20 Time   Sent To I
Notes
2020-07-20 09:56:43ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 7/20/2020
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PLEASE PROVIDE A SURVEY OF THE PROPERTY SHOWING THE
 LOCATION OF THE GENERATOR ALONG WITH THE SETBAKS FROM
 ALL PROPERTY LINES.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 IF THE FORM IS TEMPORARILY UNAVAILABLE, PLEASE REQUEST
 THAT IT BE SENT TO YOU BY EMAILING [email protected]
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 RAFAELA THERMIDOR, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 TTY: 800.955.8771
 E: [email protected]
 W: WPB.ORG


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved