| Plan Review Stops For Permit 20070263 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-08-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-15 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-15 |
Time |
12:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-28 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-28 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2020-07-28 13:31:57 | PLAN REVIEW GENERATOR - BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) PROVIDE WIND DESIGN LOADS FOR THE GENERATOR PER FBC | | | 107.3.5.3 AND R301.2 AS REQUIRED FOR THE GENERATOR PAD | | | ENGINEERING. | | | 2) STRUCTURAL DETAIL OF PAD AND DESIGN LOADS SHALL BE | | | SIGNED AND SEALED BY A DESIGN PROFESSIONAL. | | | 3) PROVIDE STRUCTURAL DETAIL OF GENERATOR PAD. | | | 4) PROVIDE A SITE PLAN. SHOW LOCATION OF PROPOSED | | | GENERATOR. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-08-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-15 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-15 |
Time |
12:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-28 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-28 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2020-07-28 13:29:59 | PLAN REVIEW GENERATOR - ELECTRICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1) PROVIDE NEW LOAD CALCULATIONS. | | | PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE EXISTING | | | AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE IS | | | ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-28 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-28 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2020-07-28 13:27:51 | A SEPERATE GAS PERMIT IS REQUIRED. CT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-08-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-15 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-29 |
Time |
09:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-28 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-10 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-28 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-28 |
Time |
13:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-08-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-15 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-15 |
Time |
12:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-28 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-28 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2020-07-28 13:33:08 | PLAN REVIEW GENERATOR - DIGITAL SIGNATURES AND SEALS | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON | | | ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15 | | | | | | 2) DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 3) UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | | | | 4) FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | | | NOTE: YOU MAY PROVIDE A PAPER PLAN WITH WET SIGNATURE | | | AND SEAL PRIOR TO PERMIT. | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-08-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2020-08-05 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-07-20 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2020-07-20 |
Time |
|
Sent To |
I |
|
| Notes |
| 2020-07-20 09:56:43 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 7/20/2020 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PLEASE PROVIDE A SURVEY OF THE PROPERTY SHOWING THE | | | LOCATION OF THE GENERATOR ALONG WITH THE SETBAKS FROM | | | ALL PROPERTY LINES. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | IF THE FORM IS TEMPORARILY UNAVAILABLE, PLEASE REQUEST | | | THAT IT BE SENT TO YOU BY EMAILING [email protected] | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | TTY: 800.955.8771 | | | E: [email protected] | | | W: WPB.ORG |
|
|