Plan Review Details - Permit 20070232
Plan Review Stops For Permit 20070232
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2020-10-18 Cont ID  
Sent By jwitmer Date 2020-10-18 Time 14:08 Rev Time 0.00
Received By jwitmer Date 2020-10-18 Time 14:00 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2020-09-21 Cont ID  
Sent By jwitmer Date 2020-09-21 Time 11:24 Rev Time 0.00
Received By jwitmer Date 2020-09-21 Time 10:45 Sent To  
Notes
2020-09-21 11:18:502ND REQUEST.TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:44
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-08-11 Cont ID  
Sent By jwitmer Date 2020-08-11 Time 08:28 Rev Time 0.00
Received By jwitmer Date 2020-08-11 Time 07:55 Sent To  
Notes
2020-08-11 08:27:55PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2020-12-18 Cont ID  
Sent By jwitmer Date 2020-12-18 Time 08:37 Rev Time 0.00
Received By jwitmer Date 2020-12-18 Time 08:01 Sent To  
Notes
2020-12-18 08:37:48PROFLEX SUPER SIM 90 UNDERLAYMENT/ TILE
 IIC= 50 / 6 INCH SLAB NO DROPPED CEILING
 STC=52 / 6 INCH SLAB NO DROPPED CEILING
 FLAME=0
 SMOKE= 0
 J. WITMER BUILD PLAN REVIEW 12/18/2020
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2020-11-17 Cont ID  
Sent By jwitmer Date 2020-11-17 Time 14:12 Rev Time 0.00
Received By jwitmer Date 2020-11-17 Time 13:29 Sent To  
Notes
2020-11-17 14:12:15WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20070232
 ADD: 616 CLEARWATER PARK DR # 312
 CONT: TRYMACK DEVELOPERS
 TEL: 561-632-8396
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 5TH REVIEW
 DATE: TUES. NOV. 17TH/2020
 ACTION: DENIED
  
  
 1) COMPLIED.
  
 2) 4TH REQUEST!!!!
 THE ORIGINAL PLANS NOR PERMIT APPLICATION INDICATED THE
 REMOVAL AND REPLACEMENT OF FLOOR COVERINGS, THIS REVIEW
 CYCLE A SALES BROCHURE FOR PROFLEX MAXIMUM SIM-90 WAS
 SUBMITTED AND TEST REPORTS FOR PROFLEX SUPER SIM 90.
 PLEASE NOTE THE SUBMITTED TEST REPORTS WERE TEST ON FOR
 AN 8 INCH SLAB. THE CITY RETENTION OF PLANS INDICATES
 THIS BUILDING WAS BUILT UNDER PERMIT # 01091471 SHEET
 54 DETAILS 6-8 SHOW ALL RAISED FLOORS ARE 7 INCH PT
 SLABS. THE SUBMITTED TEST REPORTS WILL ONLY WORK ON
 BUILDINGS WITH A 8 INCH SLAB SINCE THE IIC RATING WAS
 50, IT WOULD NOT MEET THE MINIMUM RATING OF 50 ON A 7
 INCH SLAB. YOU WILL NEED TO SUBMIT TEST REPORTS FOR 6
 INCH SLABS AS INDICATED BELOW.
 FLOOR INSULATION (FBC-B 2017)
 FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL
 NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR
 ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE
 QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A
 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS SHOWING
 COMPLIANCE WITH:
  
 TYPE I AND II BUILDINGS
 2A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 2B) FBC-B 2017 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2C) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2020-11-04 Cont ID  
Sent By jwitmer Date 2020-11-04 Time 08:00 Rev Time 0.00
Received By jwitmer Date 2020-11-04 Time 07:31 Sent To  
Notes
2020-11-04 08:02:52WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20070232
 ADD: 616 CLEARWATER PARK DR # 312
 CONT: TRYMACK DEVELOPERS
 TEL: 561-632-8396
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 4TH REVIEW
 DATE:WED. NOV. 04TH/2020
 ACTION: DENIED
  
  
 1) COMPLIED.
  
  
 2) 3RD REQUEST!!!!
 THE ORIGINAL PLANS NOR PERMIT APPLICATION INDICATED THE
 REMOVAL AND REPLACEMENT OF FLOOR COVERINGS, THIS REVIEW
 CYCLE A SALES BROCHURE FOR PROFLEX MAXIUM SIM-90 WAS
 SUBMITTED NOT A TEST!!!!!
 PLEASE NOTE ON SHEET 2 OF 4 THE IIC & STC RATINGS OF 50
 & 57 ARE TESTED ON A 8 INCH SLAB. WITHOUT DOCUMENTATION
 THAT THIS LOCATION HAS A 8 INCH SLAB WE ALWAYS NEED
 TESTING FOR A 6 INCH SLAB, ACTUAL TEST REPORTS!!!!
 FLOOR INSULATION (FBC-B 2017)
 FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL
 NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR
 ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE
 QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A
 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS SHOWING
 COMPLIANCE WITH:
  
 TYPE I AND II BUILDINGS
 2A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 2B) FBC-B 2017 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2C) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2020-10-18 Cont ID  
Sent By jwitmer Date 2020-10-18 Time 14:30 Rev Time 0.00
Received By jwitmer Date 2020-10-18 Time 14:00 Sent To  
Notes
2020-10-18 14:30:55WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20070232
 ADD: 616 CLEARWATER PARK DR # 312
 CONT: TRYMACK DEVELOPERS
 TEL: 561-632-8396
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE:SUN. OCT.18TH/2020
 ACTION: DENIED
  
  
 4X FEE / NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B)
  
  
  
 WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS?
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
 NO TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
  
  
  
  
 1) 3RD REQUEST, THE DESIGNER OF RECORD QUOTED THE CODE
 SECTION THAT NEED TO SHOW COMPLIANCE. PLEASE REVIEW THE
 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATIVE CODE SECTION 107.2.1.
 W.P.B. ADMINISTRATIVE CODE/2017 DRAWINGS &
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC TO
 THE TECHNICAL CODES " THE CODE SHALL NOT BE CITED AS A
 WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1ST ROUND OF COMMENTS. BATH # 2 SHOWS THE CHANGING OF A
 TUB TO A SHOWER, IT IS ASSUMED THAT WHATEVER BACKER
 BOARD IS THERE NOW PROBABLY WATER RESISTANT DRYWALL
 (GREENBOARD) IS BEING REMOVED. THE PLANS DO NOT STATE
 WHAT TYPE OF BACKER BOARD IS GOING BACK IN ITS PLACE.
 PLEASE SHOW COMPLIANCE WITH THE 2017 FBC-B SECTION:
 2017 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS A
 BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALLS
 AND CEILING PANELS IN SHOWER AREAS SHALL BE OF
 MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN
 ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. WATER
 RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE
 FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN
 INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840 AND
 THE MANUFACTURERS RECOMMENDATIONS.
  
  
 2) 2ND REQUEST!!!!
 THE ORIGINAL PLANS NOR PERMIT APPLICATION INDICATED THE
 REMOVAL AND REPLACEMENT OF FLOOR COVERINGS,
 FLOOR INSULATION (FBC-B 2017)
 FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL
 NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR
 ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE
 QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A
 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS SHOWING
 COMPLIANCE WITH:
  
 TYPE I AND II BUILDINGS
 2A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 2B) FBC-B 2017 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2C) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-09-21 Cont ID  
Sent By jwitmer Date 2020-09-21 Time 11:27 Rev Time 0.00
Received By jwitmer Date 2020-09-21 Time 10:45 Sent To  
Notes
2020-09-21 11:17:34WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20070232
 ADD: 616 CLEARWATER PARK DR # 312
 CONT: TRYMACK DEVELOPERS
 TEL: 561-632-8396
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE:MON. SEPT.21ST/2020
 ACTION: DENIED
  
 1) 2ND REQUEST,THE DESIGNER OF RECORD QOUTED THE CODE
 SECTION THAT NEED TO SHOW COMPLIANCE. PLEASE REVIEW THE
 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATIVE CODE SECTION 107.2.1.
 W.P.B. ADMINISTRATIVE CODE/2017 DRAWINGS &
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC TO
 THE TECHNICAL CODES " THE CODE SHALL NOT BE CITED AS A
 WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1ST ROUND OF COMMENTS. BATH # 2 SHOWS THE CHANGING OF A
 TUB TO A SHOWER, IT IS ASSUMED THAT WHATEVER BACKER
 BOARD IS THERE NOW PROBABLY WATER RESISTANT DRYWALL
 (GREENBOARD) IS BEING REMOVED. THE PLANS DO NOT STATE
 WHAT TYPE OF BACKER BOARD IS GOING BACK IN ITS PLACE.
 PLEASE SHOW COMPLIANCE WITH THE 2017 FBC-B SECTION:
 2017 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS A
 BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALLS
 AND CEILING PANELS IN SHOWER AREAS SHALL BE OF
 MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN
 ACCORDANCE WITH MANUFACTURER?S RECOMMENDATIONS. WATER
 RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE
 FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN
 INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840 AND
 THE MANUFACTURE?S RECOMMENDATIONS.
  
  
 2) THE ORIGINAL PLANS NOR PERMIT APPLICATION INDICATED
 THE REMOVAL AND REPLACEMENT OF FLOOR COVERINGS,
 FLOOR INSULATION (FBC-B 2017)
 FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL
 NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR
 ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE
 QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A
 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS SHOWING
 COMPLIANCE WITH:
  
 TYPE I AND II BUILDINGS
 2A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 2B) FBC-B 2017 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2C) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-11 Cont ID  
Sent By jwitmer Date 2020-08-11 Time 08:28 Rev Time 0.00
Received By jwitmer Date 2020-08-11 Time 07:55 Sent To  
Notes
2020-08-11 08:26:59WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20070232
 ADD: 616 CLEARWATER PARK DR # 312
 CONT: TRYMACK DEVELOPERS
 TEL: 561-632-8396
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. AUGUST 11TH/2020
 ACTION: DENIED
  
 1) BATH # 2 SHOWS THE CHANGING OF A TUB TO A SHOWER, IT
 IS ASSUMED THAT WHATEVER BACKER BOARD IS THERE NOW
 PROBABLY WATER RESISTANT DRYWALL (GREENBOARD) IS BEING
 REMOVED. THE PLANS DO NOT STATE WHAT TYPE OF BACKER
 BOARD IS GOING BACK IN ITS PLACE. PLEASE SHOW
 COMPLIANCE WITH THE 2017 FBC-B SECTION:
 2017 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS A
 BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALLS
 AND CEILING PANELS IN SHOWER AREAS SHALL BE OF
 MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN
 ACCORDANCE WITH MANUFACTURER?S RECOMMENDATIONS. WATER
 RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE
 FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN
 INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840 AND
 THE MANUFACTURE?S RECOMMENDATIONS.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2020-09-21 Cont ID  
Sent By jleahy Date 2020-09-21 Time 10:11 Rev Time 0.00
Received By jleahy Date 2020-09-21 Time 10:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-08-18 Cont ID  
Sent By jleahy Date 2020-08-18 Time 11:28 Rev Time 0.00
Received By jleahy Date 2020-08-18 Time 11:24 Sent To  
Notes
2020-08-18 11:46:30FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 IF YOU ARE CHANGING OUT RECEPTACLES AND OTHER DEVICES
 NEW CODE REQUIREMENT ARE IN PLACE.
  
 406.4(D) REPLACEMENTS. REPLACEMENT OF RECEPTACLES SHALL
 COMPLY WITH 40 6.4(D)(1) THROUGH (D)(6), AS APPLICABLE.
 ARC-FAULT CIRCUIT INTERRUPTER TYPE AND GROUND-FAULT
 CIRCUIT-INTERRUPTER TYPE RECEPTACLES SHALL BE INSTALLED
 IN A READILY ACCESSIBLE LOCATION.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date   Cont ID  
Sent By   Date 2020-12-21 Time   Rev Time 0.00
Received By ccarvaja Date 2020-12-17 Time 14:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date   Cont ID  
Sent By   Date 2020-11-18 Time   Rev Time 0.00
Received By lmarchan Date 2020-11-16 Time 11:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2020-11-04 Time 08:01 Rev Time 0.00
Received By lmarchan Date 2020-10-30 Time 10:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2020-10-19 Time   Rev Time 0.00
Received By lmarchan Date 2020-10-16 Time 15:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-21 Cont ID  
Sent By jwitmer Date 2020-09-21 Time 11:27 Rev Time 0.00
Received By jwitmer Date 2020-09-10 Time 15:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-18 Cont ID  
Sent By shill Date 2020-08-18 Time 14:49 Rev Time 0.00
Received By shill Date 2020-07-29 Time 16:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 6 Status P Date 2020-12-21 Cont ID  
Sent By ccole Date 2020-12-21 Time 11:14 Rev Time 0.00
Received By ccole Date 2020-12-21 Time 11:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status F Date 2020-11-18 Cont ID  
Sent By ccole Date 2020-11-18 Time 13:10 Rev Time 0.00
Received By ccole Date 2020-11-17 Time 09:37 Sent To  
Notes
2020-11-17 09:38:524TH REVIEW FBC-2017 PLUMBING
 PERMIT-20070232
 11/18/2020
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 COMMENTS # 5 FROM PREVIOUS REVIEWS PRINTED BELOW WAS
 NOT ADDRESSED. PLEASE COMPLY WITH THE COMMENT. THE
 REQUESTED RESPONSE NARRATIVE WAS ALSO NOT PROVIDED.
  
 5) FAIR HOUSING ACCESSIBILITY GUIDELINES: BECAUSE THE
 BUILDING WAS CONSTRUCTED IN ACCORDANCE WITH THE
 ACCESSIBILITY REQUIREMENTS OF THE FAIR HOUSING ACT AND
 THE DESIGN GUIDELINES FOR USABLE BATHROOMS IN DWELLING
 UNITS, THE ALTERATIONS THAT ARE PROPOSED IN THE
 BATHROOMS SHALL ALSO BE IN COMPLIANCE WITH THE FAIR
 HOUSING ACT. THE FAIR HOUSING ACCESSIBILITY GUIDELINES
 ARE INCLUDED IN THE FLORIDA ACCESSIBILITY CODE- 2017
 SIXTH EDITION. REFER TO REQUIRMENT 7 USUABLE KITCHENS
 AND BATHROOMS AND PAGE 7.33 IN THE FAIR HOUSING ACT
 DESIGN MANUAL.
 BASED ON THE DRAWING IT IS NOT CLEAR IF USABLE BATHROOM
 TYPE A OR B WAS CHOSEN AS THE ORIGINAL DESIGN UNDER
 PERMIT-01091471, HOWEVER THE DRAWING APPEARS TO
 INDICATE THAT THE MASTER BATHROOM WAS DESIGNED AS A
 TYPE B BECAUSE GREATER ACCESS IS PROVIDED TO THE
 TUB/SHOWER UNIT. BECAUSE IT IS THIS TUB/SHOWER UNIT
 BEING CONVERTED TO A SHOWER, THE REQUIRED CLEAR FLOOR
 30?X 48? CLEAR FLOOR SPACE FOR WHEELCHAIR APPROACH MUST
 BE MAINTAINED. AS REQUESTED IN COMMENT #1 PROVIDE AN
 ENLARGED DRAWING OF THE SHOWER THAT INCLUDES THE
 DIMENSIONS OF THE SHOWER AND THE REQUIRED CLEAR FLOOR
 SPACE DIAGRAM AND DIMENSION- REFER TO SEE REQUIRMENT 7
 AND FIGURE 7D FOR GUIDANCE. COMPLIANCE ALSO REQUIRES
 THAT BACKING FOR FUTURE GRAB BAR INSTALLATIONS BE
 PROVIDED ? REFER TO FIGURE 5 AND PROVIDE DIMENSIONED
 SIDE AND BACK ELEVATION VIEWS OF THE SHOWER WALLS
 SHOWING THE LOCATIONS, LENGTHS AND WIDTHS OF THE GRAB
 BAR BACKINGS.
  
 PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE
 GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND
 DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE
 A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE
 ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET
 THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY
 GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO
 REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF
 SO REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN,
 PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A
 COPY OF THE FAIR HOUSING AFFIDAVIT. IF CHOOSING THIS
 OPTION IT WOULD BE ADVISABLE AT A MINIMUM TO INSTALL
 THE SHOWER WALL REINFORCEMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]

Review Stop P PLUMBING
Rev No 4 Status F Date 2020-11-03 Cont ID  
Sent By ccole Date 2020-11-03 Time 08:46 Rev Time 0.00
Received By ccole Date 2020-11-03 Time 07:16 Sent To  
Notes
2020-11-03 08:46:304TH REVIEW FBC-2017 PLUMBING
 PERMIT-20070232
 10/19/2020
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS A100 & P200: AS NOTED IN THE PREVIOUS REVIEWS
 THE NEW SHOWER SHALL BE INSTALLED IN COMPLIANCE WITH
 THE FAIR HOUSING ACT DESIGN MANUAL. REFER TO PAGE 7.56
 OF THE MANUAL AND SHOW THE REQUIRED 30 X 48 IN. CLEAR
 FLOOR SPACE PARALLEL TO THE FIXTURE AND FLUSH WITH THE
 CONTROL WALL. THE CURRENT DRAWINGS ARE SHOWING A
 NON-COMPLIANT INSTALLATION. PLEASE REVIEW COMMENT #5
 FROM THE PREVIOUS REVIEWS PRINTED BELOW.
  
 COMMENTS # 5 FROM THE PREVIOUS REVIEWS PRINTED BELOW
 WAS NOT ADDRESSED.
  
 5) FAIR HOUSING ACCESSIBILITY GUIDELINES: BECAUSE THE
 BUILDING WAS CONSTRUCTED IN ACCORDANCE WITH THE
 ACCESSIBILITY REQUIREMENTS OF THE FAIR HOUSING ACT AND
 THE DESIGN GUIDELINES FOR USABLE BATHROOMS IN DWELLING
 UNITS, THE ALTERATIONS THAT ARE PROPOSED IN THE
 BATHROOMS SHALL ALSO BE IN COMPLIANCE WITH THE FAIR
 HOUSING ACT. THE FAIR HOUSING ACCESSIBILITY GUIDELINES
 ARE INCLUDED IN THE FLORIDA ACCESSIBILITY CODE- 2017
 SIXTH EDITION. REFER TO REQUIRMENT 7 USUABLE KITCHENS
 AND BATHROOMS AND PAGE 7.33 IN THE FAIR HOUSING ACT
 DESIGN MANUAL.
 BASED ON THE DRAWINGS ITS APPEARS SPECIFICATION TYPE A
 WAS CHOSEN FOR THE BATHROOM DESIGNS. PLEASE REFER TO
 PAGES 7.33- 7.59 OF THE GUIDELINES FOR CLARIFICATION.
  
 PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE
 GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND
 DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE
 A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE
 ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET
 THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY
 GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO
 REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF
 SO REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN,
 PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A
 COPY OF THE FAIR HOUSING AFFIDAVIT. IF CHOOSING THIS
 OPTION IT WOULD BE ADVISABLE AT A MINIMUM TO INSTALL
 THE SHOWER WALL REINFORCEMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status F Date 2020-10-19 Cont ID  
Sent By ccole Date 2020-10-19 Time 11:29 Rev Time 0.00
Received By ccole Date 2020-10-19 Time 07:14 Sent To  
Notes
2020-10-19 11:32:263RD REVIEW FBC-2017 PLUMBING
 PERMIT-20070232
 10/19/2020
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 COMMENTS # 5 FROM THE 1ST AND 2ND REVIEWS PRINTED BELOW
 WAS NOT ADDRESSED. PLEASE COMPLY WITH THE COMMENT. THE
 REQUESTED RESPONSE NARRATIVE WAS ALSO NOT PROVIDED.
  
 5) FAIR HOUSING ACCESSIBILITY GUIDELINES: BECAUSE THE
 BUILDING WAS CONSTRUCTED IN ACCORDANCE WITH THE
 ACCESSIBILITY REQUIREMENTS OF THE FAIR HOUSING ACT AND
 THE DESIGN GUIDELINES FOR USABLE BATHROOMS IN DWELLING
 UNITS, THE ALTERATIONS THAT ARE PROPOSED IN THE
 BATHROOMS SHALL ALSO BE IN COMPLIANCE WITH THE FAIR
 HOUSING ACT. THE FAIR HOUSING ACCESSIBILITY GUIDELINES
 ARE INCLUDED IN THE FLORIDA ACCESSIBILITY CODE- 2017
 SIXTH EDITION. REFER TO REQUIRMENT 7 USUABLE KITCHENS
 AND BATHROOMS AND PAGE 7.33 IN THE FAIR HOUSING ACT
 DESIGN MANUAL.
 BASED ON THE DRAWING IT IS NOT CLEAR IF USABLE BATHROOM
 TYPE A OR B WAS CHOSEN AS THE ORIGINAL DESIGN UNDER
 PERMIT-01091471, HOWEVER THE DRAWING APPEARS TO
 INDICATE THAT THE MASTER BATHROOM WAS DESIGNED AS A
 TYPE B BECAUSE GREATER ACCESS IS PROVIDED TO THE
 TUB/SHOWER UNIT. BECAUSE IT IS THIS TUB/SHOWER UNIT
 BEING CONVERTED TO A SHOWER, THE REQUIRED CLEAR FLOOR
 30?X 48? CLEAR FLOOR SPACE FOR WHEELCHAIR APPROACH MUST
 BE MAINTAINED. AS REQUESTED IN COMMENT #1 PROVIDE AN
 ENLARGED DRAWING OF THE SHOWER THAT INCLUDES THE
 DIMENSIONS OF THE SHOWER AND THE REQUIRED CLEAR FLOOR
 SPACE DIAGRAM AND DIMENSION- REFER TO SEE REQUIRMENT 7
 AND FIGURE 7D FOR GUIDANCE. COMPLIANCE ALSO REQUIRES
 THAT BACKING FOR FUTURE GRAB BAR INSTALLATIONS BE
 PROVIDED ? REFER TO FIGURE 5 AND PROVIDE DIMENSIONED
 SIDE AND BACK ELEVATION VIEWS OF THE SHOWER WALLS
 SHOWING THE LOCATIONS, LENGTHS AND WIDTHS OF THE GRAB
 BAR BACKINGS.
  
 PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE
 GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND
 DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE
 A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE
 ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET
 THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY
 GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO
 REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF
 SO REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN,
 PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A
 COPY OF THE FAIR HOUSING AFFIDAVIT. IF CHOOSING THIS
 OPTION IT WOULD BE ADVISABLE AT A MINIMUM TO INSTALL
 THE SHOWER WALL REINFORCEMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-09-15 Cont ID  
Sent By ccole Date 2020-09-15 Time 08:46 Rev Time 0.00
Received By ccole Date 2020-09-15 Time 06:49 Sent To  
Notes
2020-09-15 08:47:522ND REVIEW FBC-2017 PLUMBING
 PERMIT-20070232
 9/15/2020
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 COMMENTS #3 & 5 FROM THE 1ST REVIEW PRINTED BELOW WERE
 NOT ADDRESSED. PLEASE COMPLY WITH THE COMMENTS. THE
 REQUESTED RESPONSE NARRATIVE WAS ALSO NOT PROVIDED.
  
 3) BATH TUB/SHOWER CONVERSION: SHOW THE LOCATION OF THE
 NEW DRAIN IN THE DRAWING AND INDICATE IF IT BEING
 RELOCATED OR REUSED IN THE ORIGINAL TUB/SHOWER
 LOCATION. A DETAIL IS REQUIRED FOR A RELOCATED DRAIN
 BASED ON SECTION 1002.1: THE VERTICAL DISTANCE FROM THE
 FIXTURE OUTLET TO THE TRAP WEIR SHALL NOT EXCEED 24
 INCHES, AND THE HORIZONTAL DISTANCE SHALL NOT EXCEED 30
 INCHES MEASURED FROM THE CENTERLINE OF THE FIXTURE
 OUTLET TO THE CENTERLINE OF THE INLET OF THE TRAP.
  
 5) FAIR HOUSING ACCESSIBILITY GUIDELINES: BECAUSE THE
 BUILDING WAS CONSTRUCTED IN ACCORDANCE WITH THE
 ACCESSIBILITY REQUIREMENTS OF THE FAIR HOUSING ACT AND
 THE DESIGN GUIDELINES FOR USABLE BATHROOMS IN DWELLING
 UNITS, THE ALTERATIONS THAT ARE PROPOSED IN THE
 BATHROOMS SHALL ALSO BE IN COMPLIANCE WITH THE FAIR
 HOUSING ACT. THE FAIR HOUSING ACCESSIBILITY GUIDELINES
 ARE INCLUDED IN THE FLORIDA ACCESSIBILITY CODE- 2017
 SIXTH EDITION. REFER TO REQUIRMENT 7 USUABLE KITCHENS
 AND BATHROOMS AND PAGE 7.33 IN THE FAIR HOUSING ACT
 DESIGN MANUAL.
 BASED ON THE DRAWING IT IS NOT CLEAR IF USABLE BATHROOM
 TYPE A OR B WAS CHOSEN AS THE ORIGINAL DESIGN UNDER
 PERMIT-01091471, HOWEVER THE DRAWING APPEARS TO
 INDICATE THAT THE MASTER BATHROOM WAS DESIGNED AS A
 TYPE B BECAUSE GREATER ACCESS IS PROVIDED TO THE
 TUB/SHOWER UNIT. BECAUSE IT IS THIS TUB/SHOWER UNIT
 BEING CONVERTED TO A SHOWER, THE REQUIRED CLEAR FLOOR
 30?X 48? CLEAR FLOOR SPACE FOR WHEELCHAIR APPROACH MUST
 BE MAINTAINED. AS REQUESTED IN COMMENT #1 PROVIDE AN
 ENLARGED DRAWING OF THE SHOWER THAT INCLUDES THE
 DIMENSIONS OF THE SHOWER AND THE REQUIRED CLEAR FLOOR
 SPACE DIAGRAM AND DIMENSION- REFER TO SEE REQUIRMENT 7
 AND FIGURE 7D FOR GUIDANCE. COMPLIANCE ALSO REQUIRES
 THAT BACKING FOR FUTURE GRAB BAR INSTALLATIONS BE
 PROVIDED ? REFER TO FIGURE 5 AND PROVIDE DIMENSIONED
 SIDE AND BACK ELEVATION VIEWS OF THE SHOWER WALLS
 SHOWING THE LOCATIONS, LENGTHS AND WIDTHS OF THE GRAB
 BAR BACKINGS.
  
 PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE
 GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND
 DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE
 A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE
 ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET
 THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY
 GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO
 REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF
 SO REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN,
 PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A
 COPY OF THE FAIR HOUSING AFFIDAVIT. IF CHOOSING THIS
 OPTION IT WOULD BE ADVISABLE AT A MINIMUM TO INSTALL
 THE SHOWER WALL REINFORCEMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-08-12 Cont ID  
Sent By ccole Date 2020-08-12 Time 17:29 Rev Time 0.00
Received By ccole Date 2020-08-12 Time 15:01 Sent To  
Notes
2020-08-12 17:31:551ST REVIEW FBC-2017 PLUMBING
 PERMIT-20070232
 8/12/2020
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE THE DIMENSIONS OF THE NEW SHOWER- SECTION
 417.4 FBC P.
  
 2) PROVIDE CONSTRUCTION DETAILS FOR THE NEW SHOWER
 WALLS AND SHOWER PAN- SECTIONS 417.4.1 & 417.5.2.
  
 3) SHOW THE LOCATION OF THE NEW DRAIN IN THE DRAWING
 AND INDICATE IF IT BEING RELOCATED OR REUSED IN THE
 ORIGINAL TUB/SHOWER LOCATION. A DETAIL IS REQUIRED FOR
 A RELOCATED DRAIN BASED ON SECTION 1002.1: THE VERTICAL
 DISTANCE FROM THE FIXTURE OUTLET TO THE TRAP WEIR SHALL
 NOT EXCEED 24 INCHES, AND THE HORIZONTAL DISTANCE SHALL
 NOT EXCEED 30 INCHES MEASURED FROM THE CENTERLINE OF
 THE FIXTURE OUTLET TO THE CENTERLINE OF THE INLET OF
 THE TRAP.
  
 4) PLEASE NOTE THAT DRAIN PIPE PENETRATIONS OF THE
 EXISTING SLAB WILL REQUIRE FIRESTOPPING TO SEAL THE
 ANNULAR SPACE AROUND THE PIPING. PROVIDE A UL TESTED
 FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN- SECTION
 714.4.1.2 FBC B.
  
 5) FAIR HOUSING ACCESSIBILITY GUIDELINES: BECAUSE THE
 BUILDING WAS CONSTRUCTED IN ACCORDANCE WITH THE
 ACCESSIBILITY REQUIREMENTS OF THE FAIR HOUSING ACT AND
 THE DESIGN GUIDELINES FOR USABLE BATHROOMS IN DWELLING
 UNITS, THE ALTERATIONS THAT ARE PROPOSED IN THE
 BATHROOMS SHALL ALSO BE IN COMPLIANCE WITH THE FAIR
 HOUSING ACT. THE FAIR HOUSING ACCESSIBILITY GUIDELINES
 ARE INCLUDED IN THE FLORIDA ACCESSIBILITY CODE- 2017
 SIXTH EDITION. REFER TO REQUIRMENT 7 USUABLE KITCHENS
 AND BATHROOMS AND PAGE 7.33 IN THE FAIR HOUSING ACT
 DESIGN MANUAL.
 BASED ON THE DRAWING IT IS NOT CLEAR IF USABLE BATHROOM
 TYPE A OR B WAS CHOSEN AS THE ORIGINAL DESIGN UNDER
 PERMIT-01091471, HOWEVER THE DRAWING APPEARS TO
 INDICATE THAT THE MASTER BATHROOM WAS DESIGNED AS A
 TYPE B BECAUSE GREATER ACCESS IS PROVIDED TO THE
 TUB/SHOWER UNIT. BECAUSE IT IS THIS TUB/SHOWER UNIT
 BEING CONVERTED TO A SHOWER, THE REQUIRED CLEAR FLOOR
 30"X 48" CLEAR FLOOR SPACE FOR WHEELCHAIR APPROACH MUST
 BE MAINTAINED. AS REQUESTED IN COMMENT #1 PROVIDE AN
 ENLARGED DRAWING OF THE SHOWER THAT INCLUDES THE
 DIMENSIONS OF THE SHOWER AND THE REQUIRED CLEAR FLOOR
 SPACE DIAGRAM AND DIMENSION- REFER TO SEE REQUIRMENT 7
 AND FIGURE 7D FOR GUIDANCE. COMPLIANCE ALSO REQUIRES
 THAT BACKING FOR FUTURE GRAB BAR INSTALLATIONS BE
 PROVIDED- REFER TO FIGURE 5 AND PROVIDE DIMENSIONED
 SIDE AND BACK ELEVATION VIEWS OF THE SHOWER WALLS
 SHOWING THE LOCATIONS, LENGTHS AND WIDTHS OF THE GRAB
 BAR BACKINGS.
 PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE
 GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND
 DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE
 A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE
 ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET
 THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY
 GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO
 REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF
 SO REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN,
 PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A
 COPY OF THE FAIR HOUSING AFFIDAVIT. IF CHOOSING THIS
 OPTION IT WOULD BE ADVISABLE AT A MINIMUM TO INSTALL
 THE SHOWER WALL REINFORCEMENTS.
  
 6) THE PLAN INDICATES REPLACEMENT OF KITCHEN CABINETS.
 PROVIDE A SCOPE OF WORK FOR PLUMBING ALTERATIONS IN THE
 KITCHEN. CLARIFY IF THE EXISTING SINK, DISHWASHER,
 WATER SUPPLY LINES, DRAINS AND VENTS, ICE MAKER LINE
 ARE BEING REPLACED OR RELOCATED. PROVIDE RISER DRAWINGS
 FOR ALL NEW OR RELOCATED SANITARY OR WATER SUPPLY
 PIPES. REFER TO THE FAIR HOUSING ACT DESIGN MANUAL AND
 THE GUIDELINES CONTAINED IN THE FBC-ACC FOR USUABLE
 KITCHENS AND PROVIDE DRAWINGS AND DETAILS TO SHOW
 COMPLIANCE WITH THE REQUIRED CLEAR FLOOR SPACES AND
 MANUEVERING CLEARANCES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2020-11-17 Cont ID  
Sent By jwitmer Date 2020-11-17 Time 14:12 Rev Time 0.00
Received By jwitmer Date 2020-11-17 Time 13:29 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-11-04 Cont ID  
Sent By jwitmer Date 2020-11-04 Time 08:01 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-09-21 Cont ID  
Sent By jwitmer Date 2020-09-21 Time 11:24 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2020-09-10 15:40:15DIGITALLY SIGNED FILES UNDER 'SIGNATURES'

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-08-20 Cont ID  
Sent By shill Date 2020-08-20 Time 17:39 Rev Time 0.00
Received By shill Date 2020-08-20 Time 17:39 Sent To  
Notes
***NONE***