| Plan Review Stops For Permit 20070135 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-04 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-04 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-07-27 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-07-27 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-27 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2020-07-27 13:25:54 | POOL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE A SIGNED AND SEALED SOIL REPORT | | | (GEOTECHNICAL REPORT) AS NOTED ON THE DRAWINGS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-07-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-29 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-29 |
Time |
13:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-07-28 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-07-28 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2020-07-28 12:03:49 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-07-15 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-07-15 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-08-04 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-07-30 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-07-29 |
|
|
Cont ID |
|
| Sent By |
ccarvaja |
Date |
2020-07-29 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
ccarvaja |
Date |
2020-07-14 |
Time |
08:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-08-04 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-08-04 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-07-28 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-07-28 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2020-07-28 13:03:47 | 07/28/2019 1ST PLUMBING/POOL REVIEW **DENIED** WITH | | | COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. IDENTIFY ON THE PUMP CURVE WHICH CURVE KEY IS | | | SPECIFIC TO THE PUMP BEING INSTALLED ON THIS POOL. THIS | | | IS NEEDED TO CONFIRM THE MAXIMUM SYSTEM FLOW FROM THE | | | TDH CALCULATIONS PER THE WPB AMENDMENTS TO THE FBC SEC. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 2. A BACKFLOW (PVB) IS REQUIRED ON THE AUTOFILL PER THE | | | 2017 FBC-PLUMBING SEC.608.1 AND A REDUCE PRESSURE ZONE | | | VACUUM BREAKER ASSEMBLY IS REQUIRED AT METER PER THE | | | CITY OF WEST PALM BEACH CROSS CONNECTION PROGRAM. | | | | | | 3. PLANS SHOW A POOL HEATER PLEASE CLARIFY IS IT GAS OR | | | IS IT ELECTRIC, AS A GAS AND SPA HEATERS SHALL HAVE A | | | MINIMUM THERMAL EFFICIENCY OF 82 % AND AS A HEAT PUMP | | | POOL HEATERS SHALL HAVE A MINIMUM COP OF 4.0 WHEN | | | TESTED IN ACCORDANCE WITH AHRI 1160 PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | 4. IF THERE IS A POOL HEATER, PLEASE PROVIDE | | | SPECIFICATIONS PER THE WPB AMENDMENTS TO FBC SEC. | | | 107.2.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
P |
Date |
2020-07-29 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2020-07-29 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2020-07-29 |
Time |
18:16 |
Sent To |
|
|
| Notes |
| 2020-07-29 18:18:36 | PRIVATE PROVIDER IS PLANNING AND BUILDING CONSULTANTS | | | LLC (STEVE KENNEDY) BU587 PX808 BN1845 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-08-04 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-08-04 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-07-27 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-07-27 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-27 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-07-15 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-07-15 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2020-07-15 13:55:42 | NOTE POOL EDGE MUST BE A MINIMUM OF 5' OFF ALL PORTION | | | OF REAR PROPERTY LINE. |
|
|