| Plan Review Stops For Permit 20070030 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-10-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-08 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-08 |
Time |
08:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-15 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-15 |
Time |
12:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-08-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-17 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-17 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2020-08-17 15:32:47 | NEW SFR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE SHOW ONE BATHROOM/TOILET ROOM DOOR ON THE | | | FIRST FLOOR TO HAVE A 29-INCH CLEAR OPENING FBC | | | R320.1.1 (A 2' 6" DOOR DOES NOT PROVIDE A 29" CLEAR | | | OPENING FROM THE EDGE OF DOOR TO THE DOOR STOP WHEN | | | OPEN AT 90 DEGREE). | | | 2) PLEASE SHOW THE WINDOWSILL HEIGHT FOR THE SLEEPING | | | ROOM EMERGENCY EGRESS WINDOWS TO COMPLY WITH FBC | | | R310.2.2 | | | 3) PLEASE SHOW THE LOCATION AND SIZE OF THE REQUIRED | | | ATTIC ACCESS TO ALL ROOF AREAS FBC R807.1 | | | 4) PLEASE SHOW THE FLOOR / CEILING ASSEMBLY REQUIRED | | | DRAFT STOPPING DETAILS AND LOCATIONS FBC R302.12 | | | 5) PLEASE SHOW THE GUARD RAIL DETAILS TO COMPLY WITH | | | FBC R312 | | | 6) PLEASE SHOW THE GUARD RAIL ATTACHMENTS TO COMPLY | | | WITH THE REQUIRED LIVE LOADS FBC R301.5 | | | 7) PLEASE SHOW THE BLDG. SQUARE FOOTAGE - LIVING SPACE, | | | ROOFED PATIO AND GARAGE. | | | 8) PRODUCT APPROVALS (17-0504.01) AND (18-0430.06) ARE | | | NOT SHOWING UP PROPERLY IN PROJECTDOX - PLEASE UPLOAD | | | THEM TO PROJECTDOX AGAIN. | | | 9) SIGNED AND SEALED DRAWINGS AND DOCUMENTS IN | | | PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED | | | BY THE ENGINEER OR ARCHITECT TO BE USED IN ELECTRONIC | | | PLAN REVIEW. - OR - IF YOUR ENGINEER OR ARCHITECT DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - PLEASE | | | DROP OFF (CITY HALL DROP BOX) THE ORIGINAL SIGNED AND | | | SEALED DRAWINGS/DOCUMENTS ALONG WITH A "PLAN REVIEW | | | REQUEST FORM" EXPLAINING THE REASON FOR SUBMITTING THE | | | DOCUMENT OR DRAWINGS. PLAN REVIEW REQUEST FORM CAN BE | | | OBTAINED BY E MAILING [email protected] AND ASKING FOR THE | | | FORM. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-09-29 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-09-29 |
Time |
20:07 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-09-29 |
Time |
19:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-09-13 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-09-13 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-09-13 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2020-09-13 14:32:13 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | | | | 1. SERVICE ENTRANCE CONDUCTOR SIZE HAS BEEN CORRECTED | | | BUT NOW #350MCM FEEDERS ARE SHOWN TO 200AMP PANEL"A" | | | THEN ANOTHER 100AMP PANEL "B" BEING FED FROM 200AMP | | | PANEL "A". AMPERAGE FOR 200AMP PANEL CANNOT EXCEED | | | 200AMPS. PROVIDE LOAD CALCULATION FOR 200AMP PANEL | | | INCLUDING LOAD FROM 100AMP SUB-PANEL. NEC 220, FBC | | | 107.2.1 | | | | | | INFORMATIONAL NOTE: PERHAPS AN MDP PANEL WITH A 200A | | | OCP FEEDER TO PANEL "A" AND A 100A OCP FEEDER TO PANEL | | | "B"??? *** ONLY A SUGGESTION*** ANY CODE COMPLIANT | | | DESIGN WILL SUFFICE. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-08-03 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-08-03 |
Time |
21:57 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-08-03 |
Time |
20:53 |
Sent To |
|
|
| Notes |
| 2020-08-03 21:56:56 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. SERVICE ENTRANCE CONDUCTORS TO SERVICE DISCONNECTING | | | MEANS ARE SHOWN AS 3-3/0 CU FOR A 300AMP SERVICE. WIRE | | | SIZE IS INSUFFICENT FOR SERVICE SIZE SHOWN. NEC | | | 310.15B16, 240.4, 230.31 | | | | | | 2. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC EC R404.1 | | | | | | 3. COULD NOT FIND SMOKE/CARBON ALARM ON 1ST FLOOR? | | | FBC-R 314 &315 | | | | | | 4. PROVIDE NOTE ON PLAN THAT LOW VOLTAGE WILL REQUIRE A | | | SEPARATE PERMIT. FBC 107.2.1 FBC 105.1 | | | | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2020-09-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-09-23 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-09-23 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2020-09-23 14:01:06 | SEPARATE PERMIT REQUIRED FOR GAS PIPING TO THE TANKLESS | | | WATER HEATERS, THE RANGE, AND THE VENTLESS FIREPLACES. | | | COMPLETE PLANS ARE REQUIRED INCLUDING A GAS RISER | | | DRAWING, SPECS FOR ALL APPLIANCES AND EQUIPMENT, | | | VENTING PLANS , AND THE COMBUSTION AIR CALCULATIONS ON | | | SHEET P103 SHALL ALSO BE SUBMITTED UNDER THE GAS PIPING | | | PERMIT. | | | PLEASE NOTE THAT A REVIEW OF THE GAS PLANS AND | | | SPECIFCATIONS WAS NOT COMPLETED AT THIS TIME HOWEVER | | | THE SUBMITTED SPECS FOR THE RANGE INDICATE A HIGHER | | | BTUH LOAD THAN THE LOAD SHOWN ON THE GAS RISER DRAWING- | | | SHEET P103. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2020-09-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-09-09 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-09-09 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2020-09-09 11:50:56 | SEPARATE PERMIT REQUIRED FOR GAS PIPING TO THE TANKLESS | | | WATER HEATERS, THE RANGE, AND THE VENTLESS FIREPLACES. | | | COMPLETE PLANS ARE REQUIRED INCLUDING A GAS RISER | | | DRAWING, SPECS FOR ALL APPLIANCES AND EQUIPMENT, | | | VENTING PLANS , AND THE COMBUSTION AIR CALCULATIONS ON | | | SHEET P103 SHALL ALSO BE SUBMITTED UNDER THE GAS PIPING | | | PERMIT. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-08-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-08-03 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-08-03 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2020-08-03 16:12:20 | 1ST REVIEW FBC-2017 RES. FUEL GAS | | | PERMIT- 20070030 | | | 8/3/2020 | | | | | | CODES IN EFFECT: | | | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P103: THE GAS PIPING INSTALLATIONS FOR THE | | | RESIDENCE SHALL BE UNDER A SEPARATE PERMIT, HOWEVER THE | | | PLANS DO NOT PROVIDE COMBUSTION AIR CALCULATIONS OR | | | VENTING PLANS FOR THE FIREPLACES AND THE GAS RANGE- SEE | | | SECTIONS G2407.1 & G2427.1 FBC RES. PLEASE NOTE THAT | | | COMPLETE GAS PIPING PLANS UNDER SEPARATE PERMIT SHALL | | | INCLUDE THE RISER DRAWING, THE CORRECT PIPE SIZING | | | TABLES FROM THE FBC RES, AND SPECIFICATIONS FOR THE | | | REGULATORS AND ALL GAS-FIRED APPLIANCES AND EQUIPMENT. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | CCOLE@WPB | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-10-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-08 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-05 |
Time |
16:09 |
Sent To |
I |
|
| Notes |
| 2020-10-05 16:06:34 | CONTRACTOR UPLOADED STRUCTURAL DRAWINGS WITH DIGITAL | | | SIGNATURE. SEE SIGNATURE FOLDER. JG. | | | | | | I UPLOADED SOME ARCHITECTURAL PLANS TO MATCH INDEX | | | DRAWINGS ON THE COVER SHEET. ALL THE ARCHITECTURAL | | | DRAWINGS HAVE ARCHITECT'S ORIGINAL SEAL/SIGNATURE. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-09-29 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-09-29 |
Time |
20:08 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-09-21 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-15 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-01 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-08-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-17 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-14 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-10-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-10-02 |
Time |
07:00 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-09-21 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2020-10-01 16:25:59 | RECEIPT 2020-038267-0000 - $22.46 - PAID | | 2020-09-21 15:06:21 | 9/21/20 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-08-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-17 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-17 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2020-08-17 15:43:36 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-09-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-09 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-09 |
Time |
08:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-07-28 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-28 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2020-07-28 09:06:31 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20070030 | | | | | | CODES IN EFFECT: | | | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE ENERGY GAGE. FBC EC 101.5.1.1.2 | | | | | | 2) PLEASE PROVIDE THE MANUAL J FOR MECHANICAL EQUIPMENT | | | SIZING. FBC EC R403.7 | | | | | | 3) PLEASE PROVIDE DETAILS OF HOW YOU ARE ANCHORING THE | | | CU?S. FBC RES M1307.2 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2020-09-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-09-23 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-09-23 |
Time |
06:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2020-09-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-09-09 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-09-09 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2020-09-09 13:45:23 | 2ND REVIEW FBC-2017 RES. | | | PERMIT- 20070030 | | | 9/9/2020 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1ST REVIEW COMMENTS #5, 6, 8, 9, 10, 11 PRINTED BELOW | | | HAVE NOT BEEN COMPLETED ADDRESSED. | | | | | | 5) P100 & P102: THE 3" STACK CANNOT SERVE AS THE WET | | | VENT FOR THE POWDER ROOM WATER CLOSET AND LAVATORY- | | | SECTION P3108.2 FBC RES. THE WATER CLOSET IS NOT | | | VENTED. | | | | | | 6) P100 & P102: NO VENT IS SHOWN FOR THE ICE MAKER | | | TRAP- SECTION P3101.2.1 & P3105.1. THE REVISED DRAWING | | | DOES NOT SHOW A VENT FOR THE TRAP. | | | | | | 8) P101 & P102: THE RISER SHOWS AN INCORRECT 2" | | | HORIZONTAL DRAIN EXTENDING FROM THE 3" LAUNDRY WASTE | | | STACK TO THE MAIN DRAIN- A MINIMUM 3" DRAIN IS | | | REQUIRED- SECTION P3005.1.6. A 3" STACK VENT FOR THE 3" | | | WASTE STACK SHALL BE PROVIDED PER SECTION P3109.3 FBC | | | RES. THE 2" DRY VENT EXTENDING FROM THE MUD ROOM SINK | | | SHALL NOT CONNECT HORIZONTALLY INTO THE WASTE STACK AT | | | A POINT BELOW THE 2ND FLOOR CLOTHES WASHER DRAIN | | | CONNECTION- SECTIONS P3109.3 AND P3104.5. | | | | | | 9) P100 & P102: THE DRY VENT FOR THE WET VENT SERVING | | | BATH 109 THAT IS EXTENDING FROM THE SHOWER DRAIN SHALL | | | EXTEND TO THE OPEN AIR- SECTIONS P3108.2.1 & P3104.1. | | | THE DRY VENT FROM BATH 109 LAV AND SHALL NOT CONNECT | | | INTO THE 3" SOIL STACK BECAUSE OF POSSIBLE BLOCKAGE OF | | | THE LAV VENT-SECTION P3104.5. THE REVISED PLAN SHOWS A | | | 2" VTR FOR THE FIXTURES WHICH IS CODE COMPLIANT. | | | | | | 10) PROVIDE A WATER RISER DRAWING- SECTION 107.3.5.3 | | | WPB. PLEASE INCLUDE IN THE RISER THE LOCATIONS OF | | | SHUTOFF VALVES, WATER HAMMER ARRESTORS, AND BACKFLOW | | | PREVENTERS WHERE REQUIRED- SECTIONS P2902.3 & P2903.5. | | | REFER TO SECTION R403.5.1 FBC EC: CIRCULATION PUMPS FOR | | | HEATED WATER CIRCULATION SYSTEMS ARE NOT OPTIONAL. | | | PLEASE CORRECT NOTE #5 ON SHEET P106 AND VERIFY THE NEW | | | AO SMITH WATER HEATERS WILL BE EQUIPPED WITH INTEGRAL | | | CIRCULATION PUMPS. | | | | | | 11) PROVIDE EQUIPMENT SCHEDULES FOR THE WATER HEATERS | | | AND SUBMIT MANUFACTURER'S SPECIFICATIONS SECTIONS | | | P2801.3 & G2448.1. PLEASE SHOW THE LOCATIONS OF THE | | | WATER HEATERS ON THE PLUMBING FLOOR PLAN DRAWINGS. | | | PLEASE NOTE THAT THE GAS PIPING INSTALLATIONS SHALL BE | | | UNDER SEPARATE PERMIT- SECTIONS 105.3 & 107.1 WPB (SEE | | | GAS COMMENTS FOR FURTHER INFORMATION). PLEASE NOTE THAT | | | COMPLIANCE DATA FOR THE WATER HEATERS SHALL BE LISTED | | | IN THE REQUIRED ENERGY COMPLIANCE REPORT- SEE TABLE | | | C404.2 FBC EC. MANUFACTURER'S SPECIFICATIONS FOR THE | | | WATER HEATERS WERE NOT SUBMITTED. PLEASE SUBMIT SPECS | | | INCLUDING TEMPERATURE RISE AND GPM FLOW SIZING CHARTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-08-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-08-03 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-08-03 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2020-08-03 15:48:19 | 1ST REVIEW FBC-2017 RES. | | | PERMIT- 20070030 | | | 8/3/2020\ | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS P100, P101, & P102 CABANA BATH AND BATH #4: | | | THE DISTANCES FROM THE SHOWER DRAIN TRAPS TO THE COMMON | | | VENT APPEAR TO EXCEED THE MAXIMUM 6" ALLOWABLE DISTANCE | | | PER TABLE P3105.1 FBC RES. | | | | | | 2) P100 & P102: THE COMMON VENT FOR THE SINKS AT THE | | | WET BAR AND BUTLER'S PANTRY SHALL EXTEND TO THE OPEN | | | AIR- SECTION P3104.1. | | | | | | 3) P100 & P102: PROVIDE A VTR SYMBOL FOR THE AT THE | | | CONNECTION OF THE TWO VENT STACKS RISING FROM BATH #3 & | | | 4- SECTIONS P3102.1 & P3104.1. | | | | | | 4) P101 & P102: VERIFY THE SHOWER DRAIN IN BATH #3 WILL | | | CONNECT TO THE VERTICAL VENT ABOVE OR AT THE SAME | | | ELEVATION AS THE TWO WATER CLOSETS- SECTION P3108.4. | | | | | | 5) P100 & P102: THE 3" STACK CANNOT SERVE AS THE WET | | | VENT FOR THE POWDER ROOM WATER CLOSET AND LAVATORY- | | | SECTION P3108.2. | | | | | | 6) P100 & P102: NO VENT IS SHOW FOR THE ICE MAKER TRAP- | | | SECTION P3101.2.1 & P3105.1. | | | | | | 7) P101 & P102 MASTER BATH: THE DISTANCE FROM THE | | | SHOWER DRAIN TRAP TO THE COMMON VENT APPEARS TO EXCEED | | | THE MAXIMUM 6" ALLOWABLE DISTANCE PER TABLE P3105.1 FBC | | | RES. IF THE INTENTION IS THE WET VENT THE SHOWER PLEASE | | | NOTE THAT NOT MORE THAN ONE WET-VENTED FIXTURE DRAIN | | | SHALL DISCHARGE UPSTREAM OF THE DRY-VENTED FIXTURE | | | DRAIN CONNECTION. THE DRAWING SHOWS TWO. | | | | | | 8) P101 & P102: THE RISER SHOWS AN INCORRECT 2" | | | HORIZONTAL DRAIN EXTENDING FROM THE 3" LAUNDRY WASTE | | | STACK TO THE MAIN DRAIN- A MINIMUM 3" DRAIN IS | | | REQUIRED- SECTION P3005.1.6. | | | | | | 9) P100 & P102: THE DRY VENT FOR THE WET VENT SERVING | | | BATH 109 THAT IS EXTENDING FROM THE SHOWER DRAIN SHALL | | | EXTEND TO THE OPEN AIR- SECTIONS P3108.2.1 & P3104.1. | | | | | | 10) PROVIDE A WATER RISER DRAWING- SECTION 107.3.5.3 | | | WPB. PLEASE INCLUDE IN THE RISER THE LOCATIONS OF | | | SHUTOFF VALVES, WATER HAMMER ARRESTORS, AND BACKFLOW | | | PREVENTERS WHERE REQUIRED- SECTIONS P2902.3 & P2903.5. | | | | | | 11) PROVIDE EQUIPMENT SCHEDULES FOR THE WATER HEATERS | | | AND SUBMIT MANUFACTURER'S SPECIFICATIONS SECTIONS | | | P2801.3 & G2448.1. PLEASE SHOW THE LOCATIONS OF THE | | | WATER HEATERS ON THE PLUMBING FLOOR PLAN DRAWINGS. | | | PLEASE NOTE THAT THE GAS PIPING INSTALLATIONS SHALL BE | | | UNDER SEPARATE PERMIT- SECTIONS 105.3 & 107.1 WPB (SEE | | | GAS COMMENTS FOR FURTHER INFORMATION) .PLEASE NOTE THAT | | | COMPLIANCE DATA FOR THE WATER HEATERS SHALL BE LISTED | | | IN THE REQUIRED ENERGY COMPLIANCE REPORT- SEE TABLE | | | C404.2 FBC EC. | | | | | | 12) A100 & A102: PROVIDE COMPLETE DIMENSIONS FOR THE | | | SHOWERS ON THE PLAN AND PROVIDE SHOWER PAN DETAILS PER | | | SECTIONS P2708.1 & P2709.1. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2020-08-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-17 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-17 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2020-10-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-08 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-08 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2020-10-05 16:07:29 | SIGNATURE PROVISO: | | | 1- SHEET C-1 FROM GRUBER CONSULTING ENGINEER'S INC: | | | PROVIDE HARD COPY OF DRAWING WITH ENGINEER' S ORIGINAL | | | SEAL AND SIGNATURE OR UPLOAD DRAWING WITH ENGINEER'S | | | DIGITAL SIGNATURE. JG. | | | | | | NOTE: HARDCOPIES OF ALL THE ARCHITECTURAL, ELECTRICAL, | | | PLUMBING AND MECHANICAL DRAWINGS HAVE THE ARCHITECT'S | | | ORIGINAL SEAL/SIGNATURE AND WERE SENT TO CITY STORAGE. | | | JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2020-10-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-02 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-02 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2020-10-02 14:22:45 | SIGNATURE REVIEW COMMENTS: | | | 1- STRUCTURAL DRAWINGS: | | | A)THE STRUCTURAL DRAWINGS THAT WERE DROPPED OFF IN CITY | | | HALL DON'T HAVE THE SIGNATURE OF THE ENGINEER OF | | | RECORD. (NOTE: DRAWINGS UPLOADED TO PROJECTOX WERE NOT | | | SIGNED/SEALED BY THE ENGINEER OF RECORD EITHER). | | | DRAWINGS NEED TO HAVE THE ORIGINAL SIGNATURE AND DATE | | | OF THE ENGINEER WHO SIGNED THE PLANS AS REQUIRED BY | | | SEC. 61G15-23.001 FAC AND CHAPTER 471 F.S. WHEN | | | SUBMITTING PLANS/DOCUMENTS FOR PUBLIC RECORDS. | | | PLANS NEED TO BE RE-UPLOADED TO PROJECTDOX WITH THE | | | ENGINEER'S SEAL/SIGNATURE. | | | | | | NOTE: IN ORDER TO EXPEDITE THE REVIEW PROCESS, IT IS | | | PREFERABLE TO DOWNLOAD THE STRUCTURAL DRAWINGS TO | | | PROJECTDOX WITH THE ENGINEER'S DIGITAL SIGNATURE. | | | OTHERWISE, HARD COPY PLANS WITH ENGINEER'S ORIGINAL | | | SEAL/SIGNATURE THAT MATCH PLANS UPLOADED TO PROJECTDOX | | | ARE REQUIRED TO BE DROPPED OFF IN CITY HALL. | | | | | | | | | B)THE STRUCTURAL DRAWINGS THAT WERE DROPPED OFF IN CITY | | | HALL DON'T MATCH ONES UPLOADED TO PROJECTDOX. PLANS | | | UPLOADED TO PROJECTDOX WERE REVISED 2 OR 3 TIMES | | | ALREADY. NOTE: COORDINATE WITH ITEM 1A ABOVE. SEC. | | | 107.2.1 CITY AMENDMENTS. | | | | | | 2- ARCHITECTURAL PLANS THAT WERE DROPPED OFF IN CITY | | | HALL DON'T MATCH ARCHITECTURAL PLANS UPLOADED TO | | | PROJECTDOX. DRAWINGS IN PROJECTDOX DON'T HAVE DRAWING | | | A101, A501. ALSO, DRAWINGS DROPPED IN CITY HALL ARE | | | MISSING DRAWING A105. | | | PLEASE COORDINATE HARDCOPY PLANS WITH PLANS UPLOADED TO | | | PROJECTDOX TO AVOID CONFLICTS/DELAYS. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2020-09-29 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-09-29 |
Time |
20:07 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-09-29 |
Time |
20:07 |
Sent To |
|
|
| Notes |
| 2020-09-29 20:07:54 | NO THIRD PARTY VERIFICATION FOR DIGITAL SIGNATURES ON | | | ALL PLAN PAGES. SAME DEFICIENCY AS PREVIOUS TWO | | | SIGNATURE REVIEWS. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-15 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-15 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2020-09-15 12:22:32 | 2ND SIGNATURE REVIEW | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL | | | SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE | | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG | | | WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON | | | FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW | | | REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected] | | | AND ASKING FOR THE FORM. | | | ALL SHEETS MUST BE DIGITALLY SIGNED AND SEALED. FBC FS | | | 471 & 481 | | | | | | SEE 1ST SIGNATURE REVIEW | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-07-28 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-28 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2020-07-28 09:20:44 | ALL SHEETS MUST BE DIGITALLY SIGNED AND SEALED. FBC FS | | | 471 & 481 | | | | | | OPTION - 1 | | | | | | YOU MAY ELECT TO PROVIDE A HARD COPY OF PLANS WITH WET | | | SEAL AND SIGNATURE OF DESIGN PROFESSIONAL PRIOR TO | | | PERMIT. A DROP BOX HAS BEEN INSTALLED OUTSIDE CITY HALL | | | FOR THIS PURPOSE. CONTACT THE OFFICE OF DEVELOPMENT | | | SERVICES @ 561-805-8700 OR [email protected] TO STATE YOUR | | | INTENTIONS. CITY STAFF WILL REVIEW YOUR DOCUMENTS AND | | | IF APPROVED YOU WILL RECIEVE AN E-MAIL INSTRUCTING YOU | | | TO DOWNLOAD AND PRINT YOUR PERMIT AND PLANS. | | | | | | OPTION - 2 | | | : | | | YOU MAY MAIL IN A HARD COPY OF PLANS WITH WET SEAL AND | | | SIGNATURE. A FINAL INSPECTION HOLD WILL BE PLACED ON | | | YOUR PERMIT UNTIL DESIGN PROFESSIONALS SIGNATURE AND | | | SEAL ARE VERIFIED. | | | | | | OPTION -3 | | | | | | YOU MAY UPLOAD DIGITALLY SIGNED AND SEALED PLANS TO | | | YOUR PROJECTDOX. | | | | | | | | | PLEASE ADVISE HOW YOU WISH TO PROCEED. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-09-08 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-09-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2020-09-08 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-07-21 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-07-21 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2020-07-21 |
Time |
|
Sent To |
I |
|
| Notes |
|
|