| 2020-07-21 10:47:15 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER |
| | 561-822-1462 |
| | PROJECT: 650 BELVEDERE RD MCDONALDS 20070015 |
| | JULY 21, 2020 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. BLACK OLIVE TREES #6 AND #7 WERE PREVIOUSLY |
| | DISCUSSED WITH STAFF AND THE APPLICANT WAS ADVISED THAT |
| | THEY DO NOT QUALIFY FOR REMOVAL. REVISE THE TREE |
| | DISPOSITION PLAN AND LANDSCAPE PLAN TO SHOW THE TREES |
| | AS REMAINING. |
| | |
| | 2. PROVIDE THE TREE CANOPY MITIGATION CALCULATION FOR |
| | TREE #1 AS 491 SQ FT BASED ON DIAMETER. SHOW ADDED |
| | TREES CANOPY CREDIT FOR MITIGATION BASED ON CATEGORY. |
| | |
| | 3. CORRECT THE CALCULATIONS FOR REQUIRED MINIMUM SHADE |
| | TREE AND FLOWERING TREE REQUIREMENTS PER SECTION |
| | 94-443(C)(2)B. BASED ON REQUIRED OPEN SPACE OF 40%. |
| | 11,159 SQ FT REQUIRES 8 SHADE TREES AND 2 FLOWERING |
| | TREES AND 23 SHRUBS. |
| | |
| | 4. THE TERMINAL ISLAND AT THE NORTHWEST CORNER OF THE |
| | PARKING LOT REQUIRES A TREE AT THE END OF EACH ROW OF |
| | PARKING. OTHER EXISTING NON-CONFORMING ISLANDS CAN HAVE |
| | EQUIVALENT 3 PALMS ADDED TO REDUCE THE NON-CONFORMITY. |
| | ADD THE TREES AND PALMS AS REQUIRED BY SECTION |
| | 94-443(C)(3)A. FOR TERMINAL AND INTERIOR ISLANDS. |
| | |
| | 5. PROVIDE A PLAN SHOWING THE PARKING LANDSCAPE AREAS |
| | COUNTED TOWARD COMPLIANCE WITH SECTION 94-443(C)(3) AND |
| | (4) AND PROVIDE CALCULATIONS. PROVIDE THE TOTAL |
| | REQUIRED AND PROVIDED AS ONE TOTAL FOR BOTH SECTIONS. |
| | 6. MAKE CORRECTIONS TO LABELING OF EACH BUFFER LENGTH |
| | NORTH, EAST AND WEST, AND ADD THE SOUTH BUFFER |
| | MEASUREMENT AND REQUIRED AND PROVIDED TREES. |
| | |
| | 7. PROVIDE A PLANT LIST SHOWING ALL ADDED PLANT |
| | MATERIAL WITH SPECIES, REQUIRED SIZES, WITH COLUMNS |
| | ADDED FOR NATIVE AND DROUGHT TOLERANCE. SHOW EXISTING |
| | TREES TO REMAIN ON THE PLANT LIST. THIS MAY BE A CAD |
| | ISSUE. |
| | |
| | 8. UPDATE THE DESIGN OPTIONS CHART FOR FLORIDA FRIENDLY |
| | LANDSCAPE REQUIREMENTS PER SECTION 94-442(G) BASED ON |
| | THE PLANT LIST AND PROVIDE THE REQUIRED 50 POINTS. |
| | NON-CYPRESS MULCH IS REQUIRED, SO 5 POINTS CAN BE |
| | ADDED. |
| | |
| | 9. ADD A SECTION IN THE LANDSCAPE DATA CHART TO COMPLY |
| | WITH SECTION 94-445 L. PLANT SPECIES. A MINIMUM OF 60 |
| | PERCENT OF PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE |
| | OR DROUGHT TOLERANT SPECIES SELECTED FROM THE CITY LIST |
| | OR THE LIST OF SPECIES IN THE MOST RECENT EDITION OF |
| | SOUTH FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH |
| | FLORIDA LANDSCAPES. |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |