Plan Review Details - Permit 20061471
Plan Review Stops For Permit 20061471
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2020-08-20 Cont ID  
Sent By cpuell Date 2020-08-20 Time 16:17 Rev Time 0.00
Received By cpuell Date 2020-08-20 Time 16:17 Sent To  
Notes
2020-08-20 16:17:51APPLICANT CONFIRMED THAT ADDRESS SHOULD BE SUITE 126

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2020-06-30 Cont ID  
Sent By cpuell Date 2020-06-30 Time 13:40 Rev Time 0.00
Received By cpuell Date 2020-06-30 Time 13:40 Sent To  
Notes
2020-06-30 13:40:35NOT SUITE 200, IF TAKING OVER OLD LUCKY BRAND JEANS
 STORE THEN THE SUITE WOULD BE 126. PLEASE EMAIL
 [email protected] TO CONFIRM

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2021-03-01 Cont ID  
Sent By rmcphers Date 2021-03-01 Time 14:44 Rev Time 0.00
Received By rmcphers Date 2021-03-01 Time 14:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2020-12-30 Cont ID  
Sent By rmcphers Date 2020-12-30 Time 08:45 Rev Time 0.00
Received By rmcphers Date 2020-12-30 Time 08:45 Sent To  
Notes
2020-12-30 08:50:41SIGN
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
  
 SIGNED AND SEALED DRAWINGS HAVE BEEN OVERLAID (NEW
 VERSION IN PROJECTDOX) WITH A NEW DRAWING - BUILDING
 AND ZONING NEED TO REVIEW THE SAME DRAWING - WHICH
 WOULD BE THE LATEST VERSION IN PROJECTDOX - WHEN A NEW
 DRAWING TOPS A DRAWING IN PROJECTDOX THE OLD VERSION IS
 NO LONGER VALID.
 1) PLEASE PROVIDE SIGNED AND SEALED SIGN ATTACHMENT
 DETAILS FROM AN ARCHITECT OR ENGINEER TO COMPLY WITH
 THE WIND LOADS PER FBC 1609
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2020-11-30 Cont ID  
Sent By rmcphers Date 2020-11-30 Time 08:43 Rev Time 0.00
Received By rmcphers Date 2020-11-30 Time 08:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2020-09-18 Cont ID  
Sent By rmcphers Date 2020-09-16 Time 08:57 Rev Time 0.00
Received By rmcphers Date 2020-09-16 Time 08:57 Sent To  
Notes
2020-09-16 08:58:45 
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-09-09 Cont ID  
Sent By rmcdouga Date 2020-09-09 Time 08:01 Rev Time 0.00
Received By rmcdouga Date 2020-09-09 Time 08:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-08-26 Cont ID  
Sent By rmcphers Date 2020-08-26 Time 13:57 Rev Time 0.00
Received By rmcphers Date 2020-08-26 Time 13:57 Sent To  
Notes
2020-08-26 14:39:12SIGN
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE PROVIDE SIGNED AND SEALED SIGN ATTACHMENT
 DETAILS FROM AN ARCHITECT OR ENGINEER TO COMPLY WITH
 THE WIND LOADS PER FBC 1609
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-07-17 Cont ID  
Sent By rmcdouga Date 2020-07-17 Time 08:47 Rev Time 0.00
Received By rmcphers Date 2020-07-17 Time 08:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2021-01-05 Cont ID  
Sent By jleahy Date 2021-01-05 Time 15:13 Rev Time 0.00
Received By jleahy Date 2021-01-05 Time 15:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2020-12-02 Cont ID  
Sent By fgiaquin Date 2020-12-02 Time 20:40 Rev Time 0.00
Received By fgiaquin Date 2020-12-02 Time 19:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2020-09-26 Cont ID  
Sent By fgiaquin Date 2020-09-26 Time 10:52 Rev Time 0.00
Received By fgiaquin Date 2020-09-26 Time 09:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-09-12 Cont ID  
Sent By fgiaquin Date 2020-09-12 Time 19:36 Rev Time 0.00
Received By fgiaquin Date 2020-09-12 Time 18:18 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-08-19 Cont ID  
Sent By fgiaquin Date 2020-08-19 Time 20:08 Rev Time 0.00
Received By fgiaquin Date 2020-08-19 Time 19:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-07-21 Cont ID  
Sent By fgiaquin Date 2020-07-21 Time 19:25 Rev Time 0.00
Received By fgiaquin Date 2020-07-21 Time 19:03 Sent To  
Notes
2020-07-21 19:25:20ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE COMPLIANCE WITH FBC EC 405.2.5 FOR EXTERIOR
 LIGHTING. LIGHTING MUST BE CONTROLLED BY TIMER SWITCH
 CAPABLE OF RETAINING THE HOME TIME SETTING FOR AN EVENT
 OF UP TO 10 HOURS AFTER A LOSS OF POWER. A NOTE ON PLAN
 WILL SUFFICE.
  
 2. REFERENCE PERMIT NUMBER FOR BRANCH CIRCUIT AND
 DISCONNECT THAT IS REQUIRED TO POWER SIGN, TO BE DONE
 "BY OTHERS" AS ANNOTATED ON PLAN. CIRCUIT MUST BE RAN
 BY LICENSED ELECTRICIAN.
  
 SIGN CONTRACTORS F.S. 489.505 (#19) AND F.A.C.
 61G6-7.001 SPECIALTY ELECTRICAL CONTRACTORS (#2 SIGN
 SPECIALTY CONTRACTOR)
  
 3.. PLAN IS DIGITALLY SIGNED BUT THERE IS NO 3RD PARTY
 VERIFICATION CERTIFICATE FOR DIGITAL SIGNATURE.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2021-01-05 Cont ID  
Sent By jleahy Date 2021-01-05 Time 15:14 Rev Time 0.00
Received By jleahy Date 2020-12-22 Time 18:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-12-12 Cont ID  
Sent By fgiaquin Date 2020-12-12 Time 09:03 Rev Time 0.00
Received By cpuell Date 2020-11-20 Time 15:35 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-10-07 Cont ID  
Sent By lmarchan Date 2020-10-07 Time 06:56 Rev Time 0.00
Received By lmarchan Date 2020-09-15 Time 14:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-12 Cont ID  
Sent By fgiaquin Date 2020-09-12 Time 19:36 Rev Time 0.00
Received By fgiaquin Date 2020-08-12 Time 11:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-07-21 Cont ID  
Sent By fgiaquin Date 2020-07-21 Time 19:25 Rev Time 0.00
Received By fgiaquin Date 2020-06-30 Time 13:49 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 7 Status P Date 2021-03-01 Cont ID  
Sent By rmcphers Date 2021-03-01 Time 14:44 Rev Time 0.00
Received By rmcphers Date 2021-03-01 Time 14:44 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status F Date 2020-12-30 Cont ID  
Sent By rmcphers Date 2020-12-30 Time 08:50 Rev Time 0.00
Received By rmcphers Date 2020-12-30 Time 08:50 Sent To  
Notes
2020-12-30 08:52:33SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW.
 DRAWINGS DO NOT SHOW IN "ADOBE READER" AS
 DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR
 ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR
 DIGITAL SIGNATURE ? YOU CAN MAIL IN OR DROP OFF THE
 ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE
 FRONT DESK IN THE BUILDING DEPT. AT THE CITY HALL

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2020-11-30 Cont ID  
Sent By rmcphers Date 2020-11-30 Time 08:43 Rev Time 0.00
Received By rmcphers Date 2020-11-30 Time 08:43 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2020-09-18 Cont ID  
Sent By rmcphers Date 2020-09-16 Time 08:59 Rev Time 0.00
Received By rmcphers Date 2020-09-16 Time 08:58 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-09-09 Cont ID  
Sent By rmcdouga Date 2020-09-09 Time 08:01 Rev Time 0.00
Received By rmcdouga Date 2020-09-09 Time 08:01 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-08-26 Cont ID  
Sent By rmcphers Date 2020-08-26 Time 14:39 Rev Time 0.00
Received By rmcphers Date 2020-08-26 Time 14:39 Sent To  
Notes
2020-08-26 14:41:58SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW.
 DRAWINGS DO NOT SHOW IN "ADOBE READER" AS
 DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR
 ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL
 SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE
 ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG
 WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON
 FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW
 REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected]
 AND ASKING FOR THE FORM.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-07-17 Cont ID  
Sent By rmcdouga Date 2020-07-17 Time 08:47 Rev Time 0.00
Received By rmcdouga Date 2020-07-17 Time 08:47 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 5 Status P Date 2020-12-29 Cont ID  
Sent By eschneid Date 2020-12-29 Time 08:43 Rev Time 0.50
Received By eschneid Date 2020-12-28 Time 16:08 Sent To  
Notes
2020-12-29 08:54:40ARCADE IDENTITY SIGN - TYPE 1D OPTION C SUSPENDED PANEL
  
 PERMITTED: 20.67 SF
 PROPOSED: 12 SF
  

Review Stop Z ZONING
Rev No 4 Status F Date 2020-12-11 Cont ID  
Sent By eschneid Date 2020-12-11 Time 16:11 Rev Time 0.50
Received By eschneid Date 2020-12-11 Time 15:34 Sent To  
Notes
2020-12-11 16:12:10FAILED
  
 ARCADE IDENTITY SIGN - TYPE 1D OPTION C SUSPENDED PANEL
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA REQUIRE THAT RIVETS, SCREWS AND OTHER
 FASTENERS THAT EXTEND TO VISIBLE SURFACES SHALL BE
 FLUSH, FILLED AND FINISHED SO AS TO BE UNNOTICEABLE.
 THE BOLT HEADS THAT EXTEND PAST THE MOUNTING PLATE AS
 SHOWN ON THE JUNE 26, 2020 SHEET 3 SIGNED AND SEALED BY
 THE ENGINEER DO NOT MEET THIS STANDARD. IF THE BOLT
 HEADS MUST EXTEND PAST THE MOUNTING PLATE, THEY NEED TO
 BE CONCEALED BY CAPS MATCHING THE COLOR OF THE MOUNTING
 PLATE (NOT JUST PAINTED TO MATCH THE MOUNTING PLATE AS
 STATED ON THE SHEET DISCUSSED IN THE NEXT PARAGRAPH).
  
 SHEET 3 OF 4 (WITH THE CITYPLACE MANAGEMENT STAMP)
 SUBMITTED ON REVISED ON NOVEMBER 20, 2020 INCLUDES
 INFORMATION THAT IS NOT INCLUDED ON THE ENGINEER SIGNED
 PLANS. WHILE ZONING STAFF WILL ACCEPT THE NOTES
 VERIFYING 316 STAINLESS STEEL ANCHORS AND THAT AD ART
 WILL CONCEAL THE ELECTRICAL CONNECTIONS, THE NOTE THAT
 THE BOLT HEADS WILL BE PAINTED DOES NOT COMPLY WITH THE
 ROSEMARY SQUARE TENANT SIGN CRITERIA UNLESS THEY ARE
 FLUSH. THE SHEET SHOWS THE HEADS EXTENDING PAST THE
 MOUNTING PLATE WITH NO COVER. ONE SIGNED AND SEALED
 PLAN NEEDS TO SHOW COMPLIANCE WITH ALL THE APPLICABLE
 ROSEMARY SQUARE TENANT SIGN CRITERIA.
  
 PERMITTED: 20.67 SF
 PROPOSED: 12 SF
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status F Date 2020-10-06 Cont ID  
Sent By eschneid Date 2020-10-06 Time 16:39 Rev Time 0.50
Received By eschneid Date 2020-10-06 Time 15:57 Sent To  
Notes
2020-10-06 16:40:22FAILED
  
 ARCADE IDENTITY SIGN - TYPE 1D OPTION C SUSPENDED PANEL
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) REPEAT COMMENT: THE CITYPLACE MANAGEMENT APPROVAL
 STAMP IS REQUIRED ON THE PLANS. STAFF CONTINUES TO BE
 UNABLE TO LOCATE STAMPED PLANS OR A LETTER FROM
 CITYPLACE RETAIL APPROVING THE PLANS IN THE RESUBMITTAL
 DOCUMENTS.
  
 2) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA REQUIRE THAT RIVETS, SCREWS AND OTHER
 FASTENERS THAT EXTEND TO VISIBLE SURFACES SHALL BE
 FLUSH, FILLED AND FINISHED SO AS TO BE UNNOTICEABLE.
 THE BOLT HEADS THAT EXTEND PAST THE MOUNTING PLATE AS
 SHOWN ON THE JUNE 26, 2020 SHEET 3 SIGNED AND SEALED BY
 THE ENGINEER DO NOT MEET THIS STANDARD. IF THE BOLT
 HEADS MUST EXTEND PAST THE MOUNTING PLATE, THEY NEED TO
 BE CONCEALED BY CAPS MATCHING THE COLOR OF THE MOUNTING
 PLATE. SHEET 3 REVISED ON SEPTEMBER 8, 2020 INCLUDES
 THE NOTE THAT THEY WOULD BE PAINTED BLACK TO MATCH THE
 MOUNTING PLATE; HOWEVER, THE BOLTS THEMSELVES DISAPPEAR
 FROM THE DRAWINGS. DETAILS MUST BE PROVIDED TO SHOW
 THAT THE BOLT HEADS COMPLY WITH THE ROSEMARY SQUARE
 TENANT SIGN CRITERIA.
  
 3) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRES
 THAT ALL CONDUIT, CROSSOVERS, WIRING NECESSARY FOR THE
 SIGN'S ELECTRICAL CONNECTION TO BE CONCEALED AND NOT
 VISIBLE TO THE PUBLIC. ---- THE AUGUST 4, 2020 SHEET 3
 INCLUDED A NOTE THAT WHILE THE CONDUITS, CROSSOVERS AND
 WIRING REQUIRED FOR THE SIGN IS EXISTING, AD ART WAS TO
 ENSURE THAT FINAL SIGN CONNECTIONS ARE CONCEALED. THIS
 NOTE DOES NOT APPEAR ON ANY OF THE PLANS WITH THIS
 RESUBMITTAL, SO THE PLANS NEED TO BE UPDATED.
  
 PERMITTED: 20.67 SF
 PROPOSED: 12 SF
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status F Date 2020-09-11 Cont ID  
Sent By eschneid Date 2020-09-11 Time 16:43 Rev Time 0.50
Received By eschneid Date 2020-09-03 Time 15:23 Sent To  
Notes
2020-09-11 16:45:18FAILED
  
 ARCADE IDENTITY SIGN - TYPE 1D OPTION C SUSPENDED PANEL
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) THE CITYPLACE MANAGEMENT APPROVAL STAMP IS REQUIRED
 ON THE PLANS. WHILE THE RESPONSE COMMENT STATES THAT
 THIS IS PROVIDED, STAFF IS UNABLE TO LOCATE STAMPED
 PLANS OR A LETTER FROM CITYPLACE RETAIL APPROVING THE
 PLANS IN THE RESUBMITTAL DOCUMENTS.
  
 2) THE ROSEMARY SQUARE TENANT SIGN CRITERIA APPROVED ON
 SEPTEMBER 8, 2020, REQUIRE THAT THE SIGN COPY AREA
 SHALL MAINTAIN A MARGIN AT LEAST THREE (3) INCHES FROM
 ANY EDGE OF THE PERCEIVED SIGN AREA. THE PLANS
 SUBMITTED WITH THE PERMIT PROVIDE THE DIMENSION OF THE
 SIGN AND THE DIMENSION OF THE COPY AREA; HOWEVER THE
 DIMENSION FROM THE COPY AREA TO EACH SIGN EDGE IN NOT
 PROVIDED. WHILE THE OVERALL DIFFERENCE IN THE COPY AND
 SIGN EDGE TOTALS SIX (6) INCHES BOTH VERTICALLY AND
 HORIZONTALLY, SINCE NO DIMENSIONS ARE PROVIDED, STAFF
 CANNOT VERIFY THAT THE SIGN COPY IS CENTERED. NOTE:
 SCALING THE PLANS DOES NOT SHOW AN EQUIDISTANT
 DIMENSION FOR THE COPY BETWEEN THE TOP AND BOTTOM SIGN
 EDGES, WHICH MEANS THERE ARE NOT THREE (3) INCHES FROM
 THE BOTTOM OF THE COPY TO THE EDGE OF THE SIGN. ON
 SEPTEMBER 8, 2020, JORDAN RATHLEV, OF RELATED, SENT
 STAFF A COPY OF THE SIGN PLAN WHICH INCLUDED THE
 DIMENSIONS FROM THE COPY TO THE EDGES OF THE SIGN AND
 SHOWED THAT THE MINIMUM THREE (3) INCHES IS MET FOR ALL
 SIDES. A DIMENSIONED PLAN NEEDS TO BE SUBMITTED WITH
 THE PERMIT.
  
 3) THE PLANS UPLOADED ON SEPTEMBER 8, 2020, WHICH
 INCLUDE THE ENGINEER'S SEAL, DO NOT THE LATEST PLAN
 REVISIONS SUBMITTED TO THE CITY. THE NOTES AND
 DIMENSIONS THAT WERE ADDED TO THE PLANS REVISED ON
 AUGUST 4, 2020, NO LONGER APPEAR. THE PLANS SIGNED BY
 THE ENGINEER HAVE A REVISION DATED OF JUNE 22, 2020. TO
 FURTHER COMPLICATE MATTERS, THE RATHLEV PLANS SHOWING
 THE DIMENSIONS, DO NOT HAVE THE ENGINEER SEAL, NOR DO
 THEY INCLUDE THE ELECTRICAL OR ALL OF THE BUILDING
 NOTES SHOWN ON THE AUGUST 4, 2020 PLANS. SUBMIT PLANS
 THAT SHOW ALL THE NOTES ADDRESSING COMMENTS, ALL THE
 DIMENSIONS AND THAT ARE SEALED.
  
 4) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT RIVETS, SCREWS AND OTHER FASTENERS THAT EXTEND TO
 VISIBLE SURFACES SHALL BE FLUSH, FILLED AND FINISHED SO
 AS TO BE UNNOTICEABLE. THE BOLT HEADS THAT EXTEND PAST
 THE MOUNTING PLATE DO NOT MEET THIS STANDARD. IF THE
 BOLT HEADS MUST EXTEND PAST THE MOUNTING PLATE, THEY
 NEED TO BE CONCEALED BY CAPS MATCHING THE COLOR OF THE
 MOUNTING PLATE. ---- THE ORIGINALLY SUBMITTED SHEET 3
 AND THE ENGINEER STAMPED SHEET 3 FAIL TO ADDRESS THIS
 COMMENT. THE AUGUST 4, 2020 SHEET 3 ADDED THE NOTE THAT
 THEY WOULD BE PAINTED BLACK TO MATCH THE MOUNTING
 PLATE. NO DETAILS OR NOTATIONS WERE PROVIDED TO SHOW
 THAT THE BOLT HEADS WILL BE FLUSH TO THE MOUNTING PLATE
 OR FOR STAFF TO VERIFY THE ATTACHMENT METHOD.
  
 5) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRES
 THAT ALL CONDUIT, CROSSOVERS, WIRING NECESSARY FOR THE
 SIGN'S ELECTRICAL CONNECTION TO BE CONCEALED AND NOT
 VISIBLE TO THE PUBLIC. ---- THE AUGUST 4, 2020 SHEET 3
 INCLUDED A NOTE THAT WHILE THE CONDUITS, CROSSOVERS AND
 WIRING REQUIRED FOR THE SIGN IS EXISTING, AD ART WAS TO
 ENSURE THAT FINAL SIGN CONNECTIONS ARE CONCEALED. THIS
 NOTE DOES NOT APPEAR ON THE ENGINEER SIGNED PLANS, SO
 THE PLANS NEED TO BE UPDATED.
  
 6) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT ARCADE IDENTITY SIGNS BE CENTERED WITHIN THE
 ARCADE ARCHWAY. ---- THE AUGUST 4, 2020 SHEET 2
 PROVIDED THE DIMENSIONS TO VERIFY THIS REQUIREMENT. THE
 SEPTEMBER 8, 2020 UPLOADED, ENGINEER SIGNED SHEET 2 NO
 LONGER SHOW THE DIMENSIONS. THIS NEEDS TO BE CORRECTED
 AND RESUBMITTED.
  
 7) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE THE
 STUD MOUNTS TO BE SERIES 316 STAINLESS STEEL ANCHOR
 BOLTS. ---- THE AUGUST 4, 2020 SHEET 3 PROVIDED A NOTE
 TO VERIFY THIS REQUIREMENT. THE NOTE DOES NOT APPEAR ON
 THE SEPTEMBER 8, 2020 UPLOADED ENGINEER SIGNED SHEET 3.
 THIS NEEDS TO BE CORRECTED AND RESUBMITTED.
  
 8) THE BACKER PANEL SETS THE SIZE OF THE SIGN. ----
 NONE OF THE VARIOUS SHEET 3S STATE THE CORRECT SIGN
 SIZE.
  
 PERMITTED: 20.67 SF
 PROPOSED: 12 SF
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2020-07-15 Cont ID  
Sent By eschneid Date 2020-07-15 Time 16:09 Rev Time 0.50
Received By eschneid Date 2020-07-14 Time 09:35 Sent To  
Notes
2020-07-15 16:11:31FAILED
  
 ARCADE IDENTITY SIGN - TYPE 1D OPTION C SUSPENDED PANEL
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) THE CITYPLACE MANAGEMENT APPROVAL STAMP IS REQUIRED
 ON THE PLANS.
  
 2) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT THE SIGN COPY AREA SHALL MAINTAIN A MARGIN AT
 LEAST SIX (6) INCHES FROM ANY EDGE OF THE PERCEIVED
 SIGN AREA. PROVIDE A DETAIL OF THE SIGN FACE THAT
 VERIFIES THIS REQUIREMENT. PLEASE NOTE THAT USING THE
 DIMENSIONS PROVIDED; IT DOES NOT APPEAR THAT THE SIX
 (6) INCH MINIMUM IS MET. CITYPLACE RETAIL CURRENTLY HAS
 AN AMENDMENT TO THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA UNDER REVIEW BY THE CITY. IF APPROVED
 (TENTATIVELY IN SEPTEMBER), THE MARGIN WILL BE REDUCED
 TO THREE (3) INCHES MINIMUM; HOWEVER, ZONING CANNOT
 APPROVE THREE (3) INCHES UNTIL THE AMENDMENT HAS
 PASSED.
  
 3) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT ARCADE IDENTITY SIGNS BE CENTERED WITHIN THE
 ARCADE ARCHWAY. PROVIDE DIMENSIONS TO VERIFY THIS
 REQUIREMENT.
  
 4) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT RIVETS, SCREWS AND OTHER FASTENERS THAT EXTEND TO
 VISIBLE SURFACES SHALL BE FLUSH, FILLED AND FINISHED SO
 AS TO BE UNNOTICEABLE. THE BOLT HEADS THAT EXTEND PAST
 THE MOUNTING PLATE DO NOT MEET THIS STANDARD. IF THE
 BOLT HEADS MUST EXTEND PAST THE MOUNTING PLATE, THEY
 NEED TO BE CONCEALED BY CAPS MATCHING THE COLOR OF THE
 MOUNTING PLATE.
  
 5) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRES
 THAT ALL CONDUIT, CROSSOVERS, WIRING NECESSARY FOR THE
 SIGN'S ELECTRICAL CONNECTION TO BE CONCEALED AND NOT
 VISIBLE TO THE PUBLIC. IT IS UNCLEAR FROM THE PLANS
 THAT WERE PROVIDED IF THE POWER SUPPLY, ELECTRICAL
 SOURCE, CONDUIT, AND ASSOCIATED WIRING. NOTE: EXPOSED
 CONDUIT ATTACHED TO THE COLUMN DOES NOT MEET THIS
 REQUIREMENT.
  
 6) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE THE
 STUD MOUNTS TO BE SERIES 316 STAINLESS STEEL ANCHOR
 BOLTS. PROVIDE VERIFICATION OF THIS REQUIREMENT ON THE
 PLANS.
  
 7) THE BACKER PANEL SETS THE SIZE OF THE SIGN.
  
 PERMITTED: 20.67 SF
 PROPOSED: 12 SF
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]