| Plan Review Stops For Permit 20061426 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-08-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-18 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-18 |
Time |
09:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-20 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-17 |
Time |
08:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-08-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-18 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-18 |
Time |
09:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-08-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-08-10 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-08-10 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-20 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-17 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2020-07-20 09:08:24 | PLAN REVIEW GENERATOR - ELECTRICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) PROVIDE CONDUCTOR SIZES AND TYPES FOR CONTROL | | | CIRCUT. | | | | | | 2) CONTRACTOR SHALL SIGN RISER DIAGRAHM. | | | | | | NON-DESIGN PROFESSIONALS | | | | | | 1. THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE A | | | TITLE BLOCK AND SIGNATURE ON PLAN SHEETS UNDER THEIR | | | AUTHORITY ? | | | 2017 WPB AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1, SECTION 107.2.1. | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-07-30 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-07-30 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2020-07-30 14:04:49 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-20 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-17 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2020-07-20 09:10:11 | PLAN REVIEW ? GENERATOR - ? FUEL GAS | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PROVIDE GAS RISER DIAGRAHM | | | | | | 1) GAS ISOMETRIC DRAWING: | | | 1A) PROVIDE AN ISO DRAWING SHOWING THE ENTIRE SYSTEM | | | INCLUDING ALL BRANCH PIPES FROM THE METER TO THE MOST | | | REMOTE OUTLET. THE BTUH LOAD OF EACH APPLIANCE AND THE | | | LOCATIONS OF REGULATORS SHALL BE INDICATED ON THE | | | DRAWING- SECTIONS G2412.3 & G2412.4 FBC RES. | | | 1B) PROVIDE THE TOTAL DEVELOPED LENGTH OF THE SYSTEM | | | FROM THE METER TO THE MOST REMOTE OUTLET, AND BRANCH | | | LENGTH SIZES- SECTIONS G2413.4.1, G2413.4.2 & | | | G2413.4.3. PROVIDED | | | 1B) PROVIDE DELIVERY PRESSURE TO THE GENERATOR FROM THE | | | OUTLET OF THE REGULATOR- SECTION G2421.1 | | | 1C) PROVIDE THE BTUH LOAD OF THE GENERATOR. G2413.2 FBC | | | RES | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-08-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-18 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-11 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-08-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-08-10 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-21 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-20 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-01 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-07-30 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-07-30 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2020-07-30 14:03:22 | SEPARATE PLUMBING/GAS PERMIT REQUIRED BY A LICENSED | | | CONTRACTOR. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-20 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-17 |
Time |
08:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-08-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-18 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-18 |
Time |
09:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-08-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-08-10 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-08-10 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2020-08-10 16:50:50 | SIGNATURE IS REQUIRED ON ALL PAGES UNDER THE CONTRACTOS | | | CONTROL IN THIS CASE THE RISER AND LOAD CALCULATION | | | SHEETS. | | | | | | PLEASE PRINT NAME | | | | | | PLEASE SIGN NAME | | | | | | PLEASE DATE |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-20 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-17 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2020-07-20 09:06:16 | PLAN REVIEW ? GENERATOR - DIGITAL SIGNATURES AND SEALS | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | GENERATOR PAD LOAD CALC'S | | | | | | 1) THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON | | | ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15 | | | | | | 2) DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 3) UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | | | | 4) FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-07-17 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2020-07-17 |
Time |
|
Sent To |
I |
|
| Notes |
|
|