Plan Review Details - Permit 20061202
Plan Review Stops For Permit 20061202
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-10-30 Cont ID  
Sent By rmcphers Date 2020-10-30 Time 08:30 Rev Time 0.00
Received By rmcphers Date 2020-10-30 Time 08:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-09-29 Cont ID  
Sent By rmcphers Date 2020-09-29 Time 13:36 Rev Time 0.00
Received By rmcphers Date 2020-09-29 Time 13:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-11-02 Cont ID  
Sent By jleahy Date 2020-11-02 Time 11:36 Rev Time 0.00
Received By jleahy Date 2020-11-02 Time 11:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-09-30 Cont ID  
Sent By jleahy Date 2020-09-30 Time 17:08 Rev Time 0.00
Received By jleahy Date 2020-09-30 Time 17:04 Sent To  
Notes
2020-09-30 17:13:51ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 THIS IS ASIGN PERMIT, MUST BE INSTALLED BY A SIGN
 CONTRACTOR AND ELECTRICAL CONTRACTOR.
  
 VALUE OF THE SIGN IS NOT PER INDUSTRY STABDARDS (350)
  
 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF
 THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF
 BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED,
 QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS
 (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE
 BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION
 OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT
 VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING,
 MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK,
 ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 ELECTRICAL DISCONNECT REQUIRED PER 600.6(A) PLEASE
 INDICATE WHERE DISCONNECT IS LOCATED PER CODE.
  
 CONTROL OF SIGN TO MEET FBC EE CODE
  
 ALL EXTERIOR LIGHTING NOT EXEMPTED BY FBC 405.1 SHALL
 HAVE AUTOMATIC CONTROLS TO TURN OFF AT DAYLIGHT OR WHEN
 NOT REQUIRED. CONTROLS SHALL BE PHOTOSENSOR & TIME
 CLOCK OR ASTRONOMICAL TIME SWITCH. ALL TIME SWITCHES
 SHALL BE CAPABLE OF RETAINING PROGRAMING DURING A LOSS
 OF POWER FOR A MINIMUM OF 10 HOURS. FBC-EC 405.2.4

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-11-02 Cont ID  
Sent By jleahy Date 2020-11-02 Time 11:37 Rev Time 0.00
Received By jleahy Date 2020-10-21 Time 08:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-10-01 Cont ID  
Sent By lmarchan Date 2020-10-01 Time 11:58 Rev Time 0.00
Received By lmarchan Date 2020-09-14 Time 11:54 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-10-30 Cont ID  
Sent By rmcphers Date 2020-10-30 Time 08:30 Rev Time 0.00
Received By rmcphers Date 2020-10-30 Time 08:30 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-09-29 Cont ID  
Sent By rmcphers Date 2020-09-29 Time 13:36 Rev Time 0.00
Received By rmcphers Date 2020-09-29 Time 13:36 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2020-10-21 Cont ID  
Sent By jroach Date 2020-10-21 Time 11:42 Rev Time 0.00
Received By jroach Date 2020-10-21 Time 11:42 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-10-01 Cont ID  
Sent By jroach Date 2020-10-01 Time 10:39 Rev Time 0.00
Received By jroach Date 2020-10-01 Time 10:39 Sent To  
Notes
2020-10-01 11:49:41ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 10.01.2020
 PERMIT NO.: 20061202
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. THE SITE PLAN HAS THE INCORRECT ADDRESS OF THE
 PROPERTY.
  
 2. THE SITE PLAN INDICATES FIVE (5) DIFFERENT LOCATIONS
 OF SIGNS. PLEASE CLEARLY IDENTIFY WHICH LOCATIONS ARE
 INCLUDED IN THE SCOPE OF WORK FOR THIS PERMIT
 APPLICATION.
  
 3. ALL SIGNAGE SHOULD BE REVIEWED AT THE SAME TIME (CAN
 BE UNDER SEPARATE PERMITS). THE CITY?S ZONING AND LAND
 DEVELOPMENT REGULATIONS HAVE REQUIREMENTS ON THE
 MAXIMUM NUMBER OF SIGNS, SQUARE FOOTAGE OF SIGNAGE,
 ETC. WITHOUT REVIEWING ALL SIGNS AT THE SAME TIME,
 APPROVAL OF ONE SIGN MAY CAUSE ISSUES WITH THE APPROVAL
 OF OTHER PROPOSED SIGNS.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved