Plan Review Details - Permit 20061149
Plan Review Stops For Permit 20061149
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2020-09-11 Cont ID  
Sent By rmcdouga Date 2020-09-11 Time 09:26 Rev Time 0.00
Received By rmcdouga Date 2020-09-11 Time 09:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2020-09-08 Cont ID  
Sent By rmcdouga Date 2020-09-08 Time 13:15 Rev Time 0.00
Received By rmcdouga Date 2020-09-08 Time 12:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2020-08-25 Cont ID  
Sent By shill Date 2020-08-25 Time 07:02 Rev Time 0.00
Received By shill Date 2020-08-25 Time 07:02 Sent To  
Notes
2020-08-25 07:05:48****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC R 301, IT APPEARS THAT THE ASSEMBLY ON PAGE 30
 IS PROPOSED. THIS ASSEMBLY HAS A DESIGN PRESSURE
 LIMITATION OF -52 WHICH DOES NOT MEET THE PRESSURES FOR
 ZONES 2 AND 3. ENGINEERING IS REQUIRED; PLEASE PROVIDE.
  
 2. SEE PREVIOUS LIST, PROVIDE A ROOF DIAGRAM AND SHOW
 SLOPE OF PITCHED ROOF, FBC R 301.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-07-01 Cont ID  
Sent By rmcdouga Date 2020-07-01 Time 09:18 Rev Time 0.00
Received By rmcdouga Date 2020-07-01 Time 09:14 Sent To  
Notes
2020-07-01 09:20:30PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW: THE COMMENTS FROM
 THE PREVIOUS REVIEW HAVE NOT BEEN ADDRESSED.
  
 1) SUBMIT A SIGNED AND NOTARIZED OWNER BUILDER
 AFFIDAVIT FORM.
  
 2) THE VALUE OF $2000.00 FOR THIS WORK IS LOW. FBC
 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 3) SUBMIT A ROOF DIAGRAM WITH THE DIMENSIONS OF THE
 ROOF. SPECIFY THE SQUARE FOOT AREA OF THE SLOPED AND
 FLAT ROOF AREAS. SPECIFY THE PITCH OF THE SLOPED ROOF.
 THE ADDRESS OF THE PROJECT AND THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DRAWINGS IS REQUIRED
 TO BE ON THE DRAWING. FBC 107
  
 4) HI LIGHT OR CIRCLE THE ITEMS THAT APPLY TO THIS
 PROJECT IN THE POLYGLASS PRODUCT APPROVAL FOR THE FLAT
 ROOF. THIS WILL INCLUDE THE SYSTEM TYPE, THE FASTENING
 OPTIONS, THE DESIGN PRESSURE AND ANYTHING ELSE THAT
 APPLIES TO THE INSTALLATION. FBC 107 NOTE: PER
 LIMITATION #7 OF THE PRODUCT APPROVAL SIGNED AND SEALED
 ENHANCED FASTENING CALCULATIONS WILL BE REQUIRED IF THE
 DESIGN PRESSURES ARE NOT ADEQUATE FOR THE PERIMETER AND
 CORNER AREAS OF THE FLAT ROOF.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-25 Cont ID  
Sent By rmcdouga Date 2020-06-25 Time 07:54 Rev Time 0.00
Received By rmcdouga Date 2020-06-25 Time 07:54 Sent To  
Notes
2020-06-25 08:42:56PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT A SIGNED AND NOTARIZED OWNER BUILDER
 AFFIDAVIT FORM.
  
 2) THE VALUE OF $2000.00 FOR THIS WORK IS LOW. FBC
 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 3) SUBMIT A ROOF DIAGRAM WITH THE DIMENSIONS OF THE
 ROOF. SPECIFY THE SQUARE FOOT AREA OF THE SLOPED AND
 FLAT ROOF AREAS. SPECIFY THE PITCH OF THE SLOPED ROOF.
 THE ADDRESS OF THE PROJECT AND THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DRAWINGS IS REQUIRED
 TO BE ON THE DRAWING. FBC 107
  
 4) HI LIGHT OR CIRCLE THE ITEMS THAT APPLY TO THIS
 PROJECT IN THE POLYGLASS PRODUCT APPROVAL FOR THE FLAT
 ROOF. THIS WILL INCLUDE THE SYSTEM TYPE, THE FASTENING
 OPTIONS, THE DESIGN PRESSURE AND ANYTHING ELSE THAT
 APPLIES TO THE INSTALLATION. FBC 107 NOTE: PER
 LIMITATION #7 OF THE PRODUCT APPROVAL SIGNED AND SEALED
 ENHANCED FASTENING CALCULATIONS WILL BE REQUIRED IF THE
 DESIGN PRESSURES ARE NOT ADEQUATE FOR THE PERIMETER AND
 CORNER AREAS OF THE FLAT ROOF.
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2020-09-11 Cont ID  
Sent By rmcdouga Date 2020-09-11 Time 09:26 Rev Time 0.00
Received By rmcdouga Date 2020-09-10 Time 11:49 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-09-08 Cont ID  
Sent By rmcdouga Date 2020-09-08 Time 13:15 Rev Time 0.00
Received By rmcdouga Date 2020-08-25 Time 10:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-08-25 Cont ID  
Sent By shill Date 2020-08-25 Time 07:05 Rev Time 0.00
Received By shill Date 2020-08-21 Time 14:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-01 Cont ID  
Sent By rmcdouga Date 2020-07-01 Time 09:20 Rev Time 0.00
Received By rmcdouga Date 2020-06-27 Time 07:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-25 Cont ID  
Sent By rmcdouga Date 2020-06-25 Time 07:54 Rev Time 0.00
Received By rmcdouga Date 2020-06-24 Time 11:49 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-09-11 Cont ID  
Sent By rmcdouga Date 2020-09-11 Time 09:26 Rev Time 0.00
Received By rmcdouga Date 2020-09-11 Time 09:26 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-09-08 Cont ID  
Sent By rmcdouga Date 2020-09-08 Time 13:15 Rev Time 0.00
Received By rmcdouga Date 2020-09-08 Time 13:15 Sent To  
Notes
2020-09-08 13:20:24ENHANCED FASTENING CALCULATIONS FROM THE EGINEER ARE
 NOT DIGITALLLY SIGNED. THE ORIGINAL SIGNED AND SEALED
 COPIED WILL NEED TO BE SUBMITTED ALONG WITH A COMPLETED
 SUBMITTAL FORM IN THE DROP BOX AT WEST PALM BEACH CITY
 HALL TO VERIFY THE SIGNATURE. L

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-06-25 Cont ID  
Sent By rmcdouga Date 2020-06-25 Time 07:54 Rev Time 0.00
Received By rmcdouga Date 2020-06-25 Time 07:54 Sent To  
Notes
***NONE***