| Plan Review Stops For Permit 20061121 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2020-09-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-09-09 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-09-09 |
Time |
11:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2020-08-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-08-24 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-08-24 16:27:27 | TO THE BUILDING CONTRACTOR: | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. | | | | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2020-07-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-07-06 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-15 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2020-07-06 08:52:41 | ASBESTOS COMMERCIAL. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | 19120504 | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-09-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-09-22 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-09-22 |
Time |
08:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2020-09-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-09-09 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-09-09 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2020-09-09 13:19:04 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20061121 | | | ADD: 2711 EXCHANGE CT. SUITE: B | | | CONT: EDMON WALSH CONSTRUCTION | | | TEL: ??? | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | 3RD REVIEW | | | DATE: WED. SEPT. 09TH/ 2020 | | | ACTION: DENIED | | | | | | 1) COMPLIED. 2017 FBC-ACCESSIBILITY CODE SECTION | | | CLEARANCES AT WATER CLOSETS. 604.3 CLEARANCE. | | | | | | 1A-1F) COMPLIED. | | | | | | 1G) PLEASE ALSO REVIEW THE PLUMBING PLANS EXAMINERS | | | COMMENTS IN REGARDS TO THE BREAK ROOM SINK AND PERMIT | | | 19051456. | | | 2ND ROUND COMMENT. THE BREAK ROOM ALSO SHOWS AS | | | EXISTING, PLEASE SHOW HOW COMPLIANCE WITH SECTION 606 | | | SINKS. 2017 FBC-ACCESSIBILITY CODE SECTION 606.3 | | | HEIGHT. LAVATORIES AND SINKS SHALL BE INSTALLED WITH | | | THE FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE | | | 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR | | | GROUND. | | | | | | 1H) RESPONSE DOES NOT ADDRESS RECEPTION DESK. THE PLANS | | | SHOW A RECEPTION DESK PLEASE PROVIDE HOW COMPLIANCE | | | WITH SECTIONS: | | | | | | CHECK WRITING SURFACES. 2017 ACCESS. CODE 904.3.3 CHECK | | | WRITING SURFACES. WHERE PROVIDED, CHECK WRITING | | | SURFACES SHALL COMPLY WITH 902.3. 902.3HEIGHT. THE TOPS | | | OF WORK SURFACES SHALL BE 28 INCHES (710 MM) MINIMUM | | | AND 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR | | | OR GROUND. | | | SHOW COMPLIANCE WITH THE ACCESS. CODE 305.5 POSITION. | | | UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND SPACE | | | SHALL BE POSITIONED FOR EITHER A FORWARD OR PARALLEL | | | APPROACH TO AN ELEMENT. | | | | | | 2) 2ND REQUEST, RESPONSE LETTER STATE NOTES ADDED TO | | | FLOOR PLAN, FRP TO THE MOP SINK AREA AND TILE TO THE | | | RESTROOM WALLS. RESPONSE DOES NOT INDICATE WHICH PLAN | | | SHEET NOTES WERE ADDED BUT COULD NOT FIND THE NEW NOTES | | | ON THE COVERSHEET, A1.0 OR A1.1. | | | NEW COMMENT. PLEASE NOTE THIS IS A CHANGE OF | | | INTERPRETATION FROM THE BUILDING OFFICIAL ROBERT BROWN. | | | EPOXY PAINTED SURFACES NO LONGER IS APPROVED AS A | | | NON-ABSORBENT SURFACE FOR SERVICE SINKS, URINALS AND | | | WATER CLOSETS. | | | 2017 FBC-B 1210.2.2. WALLS & PARTITIONS. WALLS & | | | PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS, AND | | | WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NON-ABSORBENT | | | SURFACE TO A HEIGHT OF NOT LESS THAN 4 FEET ABOVE THE | | | FLOOR, EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIAL | | | USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS NOT | | | ADVERSELY AFFECTED BY MOISTURE. | | | | | | 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-08-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-08-24 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-08-24 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2020-08-24 16:25:34 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20061121 | | | ADD: 2711 EXCHANGE CT. SUITE: B | | | CONT: EDMON WALSH CONSTRUCTION | | | TEL: ??? | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | 1D) | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | 2ND REVIEW | | | DATE: MON. AUGUST 24TH/ 2020 | | | ACTION: DENIED | | | | | | 1) 2ND REQUEST.SHEET 1 A1.01. THE 2 EXISTING RESTROOMS | | | ARE NOT DIMENSIONED. THEY MAY OR MAY NOT COMPLY WITH | | | THE 2017 FBC-ACCESSIBILITY CODE SECTION CLEARANCES AT | | | WATER CLOSETS. 604.3 CLEARANCE. CLEARANCES AROUND THE | | | WATER CLOSETS AND IN TOILET COMPARTMENTS SHALL COMPLY | | | WITH 604.3. | | | 604.3.1. SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE | | | 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE | | | WALL AND 56 INCHES MINIMUM PERPENDICULAR FROM THE REAR | | | WALL. NOTE THE MINIMUM BACK WALL MEASUREMENT SHOULD BE | | | 7 FOOT 1 INCH. | | | | | | 1A) UNDER THE 2017 EXISTING BUILDING CODE LEVEL II | | | ALTERATIONS, SECTION 806.1 A BUILDING, FACILITY, OR | | | ELEMENT THAT IS ALTERED SHALL COMPLY WITH THE | | | PROVISIONS OF THE FLORIDA BUILDING CODE- ACCESSIBILITY. | | | IN THE ACCESSIBILITY CODE IT REFERS YOU TO | | | DISPROPORTIONATE COST. | | | | | | 1B) DISPROPORTIONATE COST. PLEASE REVIEW HOW YOU ARE TO | | | MEET DISPROPORTIONATE COST. EITHER THE CONTRACTOR OR | | | THE DESIGNER OF RECORD ON THEIR LETTERHEAD NEED TO SHOW | | | HOW THEY ARE GOING TO SPEND THE 20% DISPROPORTIONATE | | | FUNDS LISTED FOR EACH ELEMENT WHERE THE FUNDS ARE BEING | | | SPENT AND IN THE ORDER LISTED IN SECTION 202.4.1 | | | DISPROPORTIONATE COST OF THE 2017 ACCESSIBILITY CODE. | | | YOU MAY HAVE TO SPEND UP TO AN ADDITIONAL $9.000.00 | | | DOLLARS IN VALUE TO BRING ONE OR BOTH RESTROOMS INTO | | | COMPLIANCE. | | | | | | 1C-G) COMPLIED. | | | | | | | | | 1H) THE PLANS SHOW A RECEPTION DESK PLEASE PROVIDE HOW | | | COMPLIANCE WITH SECTIONS: | | | | | | CHECK WRITING SURFACES. 2017 ACCESS. CODE 904.3.3 CHECK | | | WRITING SURFACES. WHERE PROVIDED, CHECK WRITING | | | SURFACES SHALL COMPLY WITH 902.3. 902.3HEIGHT. THE TOPS | | | OF WORK SURFACES SHALL BE 28 INCHES (710 MM) MINIMUM | | | AND 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR | | | OR GROUND. | | | SHOW COMPLIANCE WITH THE ACCESS. CODE 305.5 POSITION. | | | UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND SPACE | | | SHALL BE POSITIONED FOR EITHER A FORWARD OR PARALLEL | | | APPROACH TO AN ELEMENT. | | | | | | 2) NEW COMMENT. PLEASE NOTE THIS IS A CHANGE OF | | | INTERPRETATION FROM THE BUILDING OFFICIAL ROBRT BROWN. | | | EPOXY PAINTED SURFACES NO LONGER IS APPROVED AS A | | | NON-ABSORBANT SURFACE FOR SERVICE SINKS, URINALS AND | | | WATER CLOSETS. | | | 2017 FBC-B 1210.2.2. WALLS & PARTITIONS. WALLS & | | | PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS, AND | | | WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NON-ABSORBENT | | | SURFACE TO A HEIGHT OF NOT LESS THAN 4 FEET ABOVE THE | | | FLOOR, EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIAL | | | USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS NOT | | | ADVERSELY AFFECTED BY MOISTURE. | | | | | | 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED | | | DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE | | | MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS | | | AND INFORMATION LACKING UNDER THE PRIOR REVIEW. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-07-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-07-06 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-07-06 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2020-07-06 08:50:10 | | | | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20061121 | | | ADD: 2711 EXCHANGE CT. SUITE: B | | | CONT: EDMON WALSH CONSTRUCTION | | | TEL: ??? | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | 1D) | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | 1ST REVIEW | | | DATE: MON. JULY 09/ 2020 | | | ACTION: DENIED | | | | | | 1) SHEET 1 A1.01. THE 2 EXISTING RESTROOMS ARE NOT | | | DIMENSIONED. THEY MAY OR MAY NOT COMPLY WITH THE 2017 | | | FBC-ACCESSIBILITY CODE SECTION CLEARANCES AT WATER | | | CLOSETS. 604.3 CLEARANCE. CLEARANCES AROUND THE WATER | | | CLOSETS AND IN TOILET COMPARTMENTS SHALL COMPLY WITH | | | 604.3. | | | 604.3.1. SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE | | | 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE | | | WALL AND 56 INCHES MINIMUM PERPENDICULAR FROM THE REAR | | | WALL. NOTE THE MINIMUM BACK WALL MEASUREMENT SHOULD BE | | | 7 FOOT 1 INCH. | | | | | | 1A) UNDER THE 2017 EXISTING BUILDING CODE LEVEL II | | | ALTERATIONS, SECTION 806.1 A BUILDING, FACILITY, OR | | | ELEMENT THAT IS ALTERED SHALL COMPLY WITH THE | | | PROVISIONS OF THE FLORIDA BUILDING CODE- ACCESSIBILITY. | | | IN THE ACCESSIBILITY CODE IT REFERS YOU TO | | | DISPROPORTIONATE COST. | | | | | | 1B) DISPROPORTIONATE COST. PLEASE REVIEW HOW YOU ARE TO | | | MEET DISPROPORTIONATE COST. EITHER THE CONTRACTOR OR | | | THE DESIGNER OF RECORD ON THEIR LETTERHEAD NEED TO SHOW | | | HOW THEY ARE GOING TO SPEND THE 20% DISPROPORTIONATE | | | FUNDS LISTED FOR EACH ELEMENT WHERE THE FUNDS ARE BEING | | | SPENT AND IN THE ORDER LISTED IN SECTION 202.4.1 | | | DISPROPORTIONATE COST OF THE 2017 ACCESSIBILITY CODE. | | | YOU MAY HAVE TO SPEND UP TO AN ADDITIONAL $9.000.00 | | | DOLLARS IN VALUE TO BRING ONE OR BOTH RESTROOMS INTO | | | COMPLIANCE. | | | | | | 1C) SINCE THERE MAYBE ADDITIONAL WORK TO THE RESTROOMS | | | PLEASE PROVIDE ELEVATIONS TO DETERMINE CODE COMPLIANCE | | | WITH THE ACCESSIBLE ELEMENTS WITHIN THE RESTROOMS, | | | ELEMENTS LIKE BACKING, GRAB BARS, LOCATION OF THE WATER | | | CLOSET, LAVS, MIRROR & TOILET PAPER HOLDERS ? 2017 | | | ACCESSIBILITY CODE CHAPTER 6. | | | 1D) IN THE HALL CORRIDOR THERE IS A NEW BI-FOLD DOOR | | | MARKED # 5. THERE APPEARS TO BE A SINGLE WATER FOUNTAIN | | | THAT THE BI-FOLD DOOR SWINGS INTO THE CLEAR FLOOR | | | SPACE. | | | 1E) 2017 FBC-ACCESSIBILITY CODE. 211.2 MINIMUM NUMBER. | | | NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. | | | ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH | | | 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH | | | 602.7. | | | DRINKING FOUNTAINS TO SHOW COMPLIANCE WITH 307.2 | | | PROTRUSION LIMITS. OBJECTS WITH LEADING EDGES MORE THAN | | | 27 INCHES AND NOT MORE THAN 80 INCHES ABOVE THE FINISH | | | FLOOR SHALL PROTRUDE 4 INCHES OR LESS MAXIMUM | | | HORIZONTALLY INTO THE CIRCULATION PATH. SKIRTS MAYBE | | | REQUIRED TO BE APPLIED TO THE BOTTOM OF THE DRINKING | | | FOUNTAIN. | | | | | | 1F) 606.2 CLEAR FLOOR SPACE DRINKING FOUNTAINS. A CLEAR | | | FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR A | | | FORWARD APPROACH, AND KNEE AND TOE CLEARANCE COMPLYING | | | WITH 306 SHALL BE PROVIDED. | | | | | | 1G) THE BREAK ROOM ALSO SHOWS AS EXISTING, PLEASE SHOW | | | HOW COMPLIANCE WITH SECTION 606 SINKS. 2017 | | | FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT. LAVATORIES | | | AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE | | | HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES (865 MM) | | | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 1H) THE PLANS SHOW A RECEPTION DESK PLEASE PROVIDE HOW | | | COMPLIANCE WITH SECTIONS: | | | | | | CHECK WRITING SURFACES. 2017 ACCESS. CODE 904.3.3 CHECK | | | WRITING SURFACES. WHERE PROVIDED, CHECK WRITING | | | SURFACES SHALL COMPLY WITH 902.3. 902.3HEIGHT. THE TOPS | | | OF WORK SURFACES SHALL BE 28 INCHES (710 MM) MINIMUM | | | AND 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR | | | OR GROUND. | | | SHOW COMPLIANCE WITH THE ACCESS. CODE 305.5 POSITION. | | | UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND SPACE | | | SHALL BE POSITIONED FOR EITHER A FORWARD OR PARALLEL | | | APPROACH TO AN ELEMENT. | | | | | | 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED | | | DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE | | | MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS | | | AND INFORMATION LACKING UNDER THE PRIOR REVIEW. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-09-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-09-11 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-11 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-08-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-08-27 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-08-27 |
Time |
09:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-07-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-22 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-22 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2020-07-22 12:51:43 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | TREATMENT ROOMS? WHAT KIND OF TREATMENT? 517? | | | | | | PLEASE EXPLAIN FEEDER TAP ON RISER? HOW LONG IS TAP | | | WHICH RULE DOES IT MEET? 240.21 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2020-09-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-09-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-09-17 |
Time |
13:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2020-09-03 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-09-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-09-02 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-08-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-08-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-08-14 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2020-07-02 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-07-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-07-02 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2020-07-02 10:29:21 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE ARE INDICATIONS OF TREATMENT ROOMS. | | | | | | FOR A REVIEW OF THE PROPER OCCUPANCY CLASSIFICATION PER | | | NFPA 101, PLEASE PROVIDE A BRIEF DESCIPTION OF WHAT THE | | | NATURE OF THE OCCUPANCY. WHAT IS THE NATURE OF THE | | | BUSINESS? | | | | | | | | | | | | 2) COVER SHEET & 1.1A - THERE IS AN INDICATION OF THE | | | OCCUPANCY AS BUSINESS, WITH A SQ FT OF 3082, AND AN | | | OCCUPANCY LOAD OF 31. BASED ON THAT INFORMATION PER | | | NFPA 101 CHAPTER 7, TABLE 7.3.1.2 THE OCCUPANCY LOAD | | | FACTOR IS 50SQ FT / PERSON OR 62. | | | | | | HOWEVER, THERE ARE INDICATION OF TWO SPACES/ROOMS | | | INDICATED AS GYM ON SHEET 1.1A. PER THE SAME TABLE A | | | GYM WITH NO EQUIPMENT HAS A FACTOR OF 15 SQ FT/PERSON. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | 3) SHEET 1.1A - THERE IS AN INDICATION OF THE FRONT | | | EXIT PATH LEADING TO A DOOR THAT SWINGS IN. PER NFPA | | | 101, CH 7, THIS DOOR IS REQUIRED TO SWING IN THE PATH | | | OF EGRESS. | | | | | | 7.2.1.4.2 DOOR LEAF SWING DIRECTION. DOOR LEAVES | | | REQUIRED TO BE | | | OF THE SIDE-HINGED OR PIVOTED-SWINGING TYPE SHALL SWING | | | IN THE | | | DIRECTION OF EGRESS TRAVEL UNDER ANY OF THE FOLLOWING | | | CONDITIONS: | | | (1) WHERE SERVING A ROOM OR AREA WITH AN OCCUPANT LOAD | | | OF 50 OR | | | MORE, EXCEPT UNDER ANY OF THE FOLLOWING CONDITIONS: | | | (A) DOOR LEAVES IN HORIZONTAL EXITS SHALL NOT BE | | | REQUIRED TO | | | SWING IN THE DIRECTION OF EGRESS TRAVEL WHERE PERMITTED | | | BY 7.2.4.3.8.1 OR 7.2.4.3.8.2. | | | (B) DOOR LEAVES IN SMOKE BARRIERS SHALL NOT BE REQUIRED | | | TO | | | SWING IN THE DIRECTION OF EGRESS TRAVEL IN EXISTING | | | HEALTH | | | CARE OCCUPANCIES, AS PROVIDED IN CHAPTER 19. | | | (2) WHERE THE DOOR ASSEMBLY IS USED IN AN EXIT | | | ENCLOSURE, UNLESS | | | THE DOOR OPENING SERVES AN INDIVIDUAL LIVING UNIT THAT | | | OPENS | | | DIRECTLY INTO AN EXIT ENCLOSURE | | | (3) WHERE THE DOOR OPENING SERVES A HIGH HAZARD | | | CONTENTS AREA | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | 4) SHEET 1.1A - THE PLAN SHEET INDICATES A FRONT EXIT | | | DOOR BUT IT DOES NOT INDICATE WHERE THAT FRONT EXIT | | | LEADS TO OR WHETHER THAT IS A PROTECTED EXIT PATH TO | | | | | | PER NFPA 101 CH 7 | | | | | | 7.7 DISCHARGE FROM EXITS. | | | 7.7.1* EXIT TERMINATION. EXITS SHALL TERMINATE | | | DIRECTLY, AT A PUBLIC | | | WAY OR AT AN EXTERIOR EXIT DISCHARGE, UNLESS OTHERWISE | | | PROVIDED IN | | | 7.7.1.2 THROUGH 7.7.1.4. | | | 7.7.1.1 YARDS, COURTS, OPEN SPACES, OR OTHER PORTIONS | | | OF THE EXIT | | | DISCHARGE SHALL BE OF THE REQUIRED WIDTH AND SIZE TO | | | PROVIDE ALL | | | OCCUPANTS WITH A SAFE ACCESS TO A PUBLIC WAY. | | | 7.7.1.2 THE REQUIREMENT OF 7.7.1 SHALL NOT APPLY TO | | | INTERIOR EXIT | | | DISCHARGE AS OTHERWISE PROVIDED IN 7.7.2. | | | 7.7.2 EXIT DISCHARGE THROUGH INTERIOR BUILDING AREAS. | | | EXITS SHALL | | | BE PERMITTED TO DISCHARGE THROUGH INTERIOR BUILDING | | | AREAS, PROVIDED | | | THAT ALL OF THE FOLLOWING ARE MET: | | | (1) NOT MORE THAN 50 PERCENT OF THE REQUIRED NUMBER OF | | | EXIT STAIRS | | | SERVING NORMALLY OCCUPIED AREAS OF EACH FLOOR, AND NOT | | | MORE | | | THAN 50 PERCENT OF THE EXIT STAIR CAPACITY REQUIRED FOR | | | NORMALLY | | | OCCUPIED AREAS OF EACH FLOOR, SHALL DISCHARGE THROUGH | | | AREAS ON | | | ANY LEVEL OF DISCHARGE, EXCEPT AS OTHERWISE PERMITTED | | | BY ONE OF | | | THE FOLLOWING: | | | (A) ONE HUNDRED PERCENT OF THE EXITS SHALL BE PERMITTED | | | TO | | | DISCHARGE THROUGH AREAS ON ANY LEVEL OF DISCHARGE IN | | | DETENTION AND CORRECTIONAL OCCUPANCIES AS OTHERWISE | | | PROVIDED IN CHAPTERS 22 AND 23. | | | (B) IN EXISTING BUILDINGS, THE 50 PERCENT LIMIT ON | | | EGRESS | | | CAPACITY SHALL NOT APPLY IF THE 50 PERCENT LIMIT ON THE | | | REQUIRED NUMBER OF EXITS IS MET. | | | (2) EACH LEVEL OF DISCHARGE SHALL DISCHARGE DIRECTLY | | | OUTSIDE AT THE | | | FINISHED GROUND LEVEL OR DISCHARGE DIRECTLY OUTSIDE AND | | | PROVIDE | | | ACCESS TO THE FINISHED GROUND LEVEL BY OUTSIDE STAIRS | | | OR OUTSIDE | | | RAMPS. | | | (3) THE INTERIOR EXIT DISCHARGE SHALL LEAD TO A FREE | | | AND UNOBSTRUCTED | | | WAY TO THE EXTERIOR OF THE BUILDING, AND SUCH WAY SHALL | | | BE READILY | | | VISIBLE AND IDENTIFIABLE FROM THE POINT OF DISCHARGE | | | FROM THE EXIT | | | (4) THE INTERIOR EXIT DISCHARGE SHALL BE PROTECTED BY | | | ONE OF THE | | | FOLLOWING METHODS: | | | (A) THE LEVEL OF DISCHARGE SHALL BE PROTECTED | | | THROUGHOUT BY AN | | | APPROVED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH | | | SECTION 9.7, OR THE PORTION OF THE LEVEL OF DISCHARGE | | | USED FOR | | | INTERIOR EXIT DISCHARGE SHALL BE PROTECTED BY AN | | | APPROVED | | | AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION | | | 9.7 | | | AND SHALL BE SEPARATED FROM THE NONSPRINKLERED PORTION | | | OF | | | THE FLOOR BY FIRE BARRIERS WITH A FIRE RESISTANCE | | | RATING | | | MEETING THE REQUIREMENTS FOR THE ENCLOSURE OF EXITS. | | | (SEE | | | 7.1.3.2.1.) | | | (B) THE INTERIOR EXIT DISCHARGE AREA SHALL BE IN A | | | VESTIBULE OR | | | FOYER THAT MEETS ALL OF THE FOLLOWING CRITERIA: | | | I. THE DEPTH FROM THE EXTERIOR OF THE BUILDING SHALL BE | | | NOT MORE THAN 10 FT (3050 MM), AND THE LENGTH SHALL | | | BE NOT MORE THAN 30 FT (9.1 M). | | | II. THE FOYER SHALL BE SEPARATED FROM THE REMAINDER OF | | | THE | | | LEVEL OF DISCHARGE BY FIRE BARRIERS WITH A MINIMUM 1- | | | HOUR FIRE RESISTANCE RATING, AND EXISTING INSTALLATIONS | | | OF | | | WIRED GLASS IN STEEL FRAMES SHALL BE PERMITTED TO BE | | | CONTINUED IN USE. | | | III. THE FOYER SHALL SERVE ONLY AS MEANS OF EGRESS AND | | | SHALL INCLUDE AN EXIT DIRECTLY TO THE OUTSIDE. | | | (5) THE ENTIRE AREA ON THE LEVEL OF DISCHARGE SHALL BE | | | SEPARATED FROM | | | AREAS BELOW BY CONSTRUCTION HAVING A FIRE RESISTANCE | | | RATING NOT | | | LESS THAN THAT REQUIRED FOR THE EXIT ENCLOSURE, UNLESS | | | OTHERWISE | | | PROVIDED IN 7.7.2(6). | | | (6) LEVELS BELOW THE LEVEL OF DISCHARGE IN AN ATRIUM | | | SHALL BE | | | PERMITTED TO BE OPEN TO THE LEVEL OF DISCHARGE WHERE | | | SUCH LEVEL | | | OF DISCHARGE IS PROTECTED IN ACCORDANCE WITH 8.6.7. | | | | | | | | | PLEASE REVIEW, SHOW THE ENTIRE EXIT PATH ON THE PLAN | | | SHEET AND PROVIDE FOR COMPLIANCE WITH THE REQUIREMENTS. | | | | | | | | | | | | 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2020-10-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-10-07 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-10-05 |
Time |
07:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-09-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-09-22 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-09-16 |
Time |
16:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-09-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-09-11 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-01 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-08-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-08-27 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-08-13 |
Time |
08:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-07-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-22 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-01 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2020-10-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-10-07 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-10-07 |
Time |
07:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2020-09-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-09 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-09 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2020-08-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-08-18 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-08-18 |
Time |
07:13 |
Sent To |
|
|
| Notes |
| 2020-08-18 08:19:22 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT-20061121 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE SEE 1ST CYCLE REVIEW COMMENTS, THE ADDRESS IS | | | STILL NOT CORRECT. PLEASE INCLUDE SUITE NUMBER FBC FS | | | 107.2.1 | | | | | | 2) PERMIT 19051456- SHOWS THE CONVERTING OF 1 LARGE | | | SPACE INTO 2 NEW TENANT SPACES. IT DOES NOT HOW EVER | | | SHOW ANY MECHANICAL WORK FOR SUITE B IF THIS PROJECT IS | | | FOR SUITE B PLEASE SHOW ALL NEW DUCT WORK FOR THE NEW | | | ROOMS BUILT. FBC FS 107.2.1 | | | | | | 3) PLEASE PROVIDE A VENTILATION CALCULATION FOR THIS | | | SPACE. FBC M 403 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-07-15 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-15 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2020-07-15 08:09:03 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20061121 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE CORRECT ADDRESS ON BOTH THE PLANS AND | | | THE APPLICATION. THEY HAVE DIFFERENT ADDRESSES ON EACH | | | AND I COULD NOT GET EITHER TO COME UP IN OUR GIS | | | PROGRAM. FBC FS 107.2.1 | | | | | | 2) PLEASE PROVIDE A VENTILATION CALCULATION FOR EACH | | | AREA OF TENANT SPACE. FBC M TABLE 403.3.1.1 | | | | | | 3) PLEASE PROVIDE INFORMATION ON EXISTING RTU?S WITH | | | THE VENTILATION CALCULATIONS. FBC FS 107.2.1 | | | | | | | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2020-10-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-10-06 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-10-06 |
Time |
07:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2020-09-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-09-17 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-09-17 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2020-09-17 11:54:41 | 4TH REVIEW FBC-2017 PLUMBING | | | PERMIT- 20061121` | | | 9/17/2020 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 3.0MP: THE WASTE FROM THE SINK PUMP CANNOT | | | DRAIN INTO THE INDIVIDUAL FIXTURE VENT FOR THE MOP | | | SINK- SECTIONS 712.3.5 AND 905.1 FBC P. IF THE | | | INTENTION IS TO SHOW A CONNECTION INTO A WASTE STACK, | | | THEN THE WASTE STACK SHALL RUN VERTICALLY FROM THE | | | HORIZONTAL DRAIN, AND THE MOP SINK AND KITCHEN SINK | | | FIXTURE DRAINS WOULD EACH CONNECT INDIVIDUALLY INTO THE | | | WASTE STACK. THIS MAY NOT BE POSSIBLE IF THE | | | CONFIGURATION OF THE MOP SINK VENT IS ACCURATELY SHOWN | | | AND YOU ARE ATTEMPTING TO TURN THE VENT INTO A WASTE | | | STACK; OR IF THE FIXTURE DRAIN CONNECTS HORIZONTALLY TO | | | THE DRAIN BELOW THE SLAB, THE VENT MUST BE MAINTAINED | | | OPEN TO THE AIR WITHOUT ANY OTHER WASTE DISCHARGE INTO | | | IT. ULTIMATELY A SEPARATE WASTE STACK MAY HAVE TO BE | | | INSTALLED TO ACCOMMODATE THE KITCHEN SINK. PLEASE NOTE | | | THE STACK VENT ABOVE SHALL BE THE SAME DIAMETER AS THE | | | WASTE STACK- SEE SECTIONS 913.1- 913.4 FBC P AND | | | CORRECT THE DRAWINGS. | | | | | | 2) 3.0MP: PLEASE SUBMIT MANUFACTURER?S SPECIFICATIONS | | | AND THE INSTALL GUIDELINES FOR THE LIBERTY 405 SUMP | | | PUMP INCLUDING PUMP CURVE. PROVIDE TDH (TOTAL DYNAMIC | | | HEAD) CALCULATION ON THE PLAN TO VERIFY ACCURATE SIZING | | | OF THE PUMP ACCORDING TO THE CURVE- SECTION 712.3.1 FBC | | | P. | | | | | | 3) 3.0MP: SHOW ON THE DRAWINGS THE LOCATIONS OF THE | | | REQUIRED CHECK VALVE AND FULL OPEN VALVE ON THE | | | DISCHARGE PIPING OF THE PUMP BETWEEN THE PUMP AND THE | | | GRAVITY DRAIN. SHOW HOW ACCESS FOR WILL BE PROVIDED TO | | | THE VALVES- SECTION 712.2 FBC P. | | | | | | 4) SHEET 1.0A: CONCERNING THE BREAKROOM THE | | | ARCHITECTURAL AND MEP WORK PERFORMED IN THE ROOM CANNOT | | | BE LABELED AS EXISTING IF NEVER LEGALLY PERMITTED. THE | | | PLAN SHALL BE REVIEWED AND PERMITTED AS NEW IF THERE IS | | | NO EVIDENCE OF A PERMIT OR INSPECTIONS ON RECORD FOR | | | THE WORK PERFORMED. IT HAS ALREADY BEEN ESTABLISHED | | | THAT THE PREVIOUS PERMIT PLANS UNDER 19051456 DID NOT | | | SHOW THE BREAKROOM. | | | | | | 5) 2.0E: A REVISION TO THE APPROVED ELECTRICAL PLAN IS | | | REQUIRED TO PROVIDE A RECEPTACLE UNDER THE SINK FOR THE | | | SUMP PUMP- SECTION 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2020-09-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-09-09 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-09-09 |
Time |
07:19 |
Sent To |
|
|
| Notes |
| 2020-09-09 09:47:41 | 3RD REVIEW FBC-2017 PLUMBING | | | PERMIT- 20061112 | | | 9/9/2020 | | | | | | CODES IN EFFECT: | | | | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 1.0A: THE NOTE AT THE BREAKROOM INDICATES THE | | | SINK WAS INSPECTED UNDER PERMIT #19051456. THE RECORD | | | DRAWINGS THAT ARE ON FILE FOR THE PERMIT DO NOT SHOW A | | | BREAKROOM OR SINK AT THAT LOCATION. AS PREVIOUSLY NOTED | | | IN COMMENTS #1 & 3 PRINTED BELOW, PLUMBING PIPING AND | | | ACCESSIBILITY DRAWINGS AND DETAILS ARE REQUIRED. | | | 1. FAILED. SHEET C-1: NO PLUMBING PLANS HAVE BEEN | | | SUBMITTED. INDICATE THE SUITE NUMBER BY THE ADDRESS AT | | | THE TOP OF THE PLAN SHEET- SECTION 107.2.1 WPB. THE | | | APPROVED PLANS UNDER PERMIT- 19051456 DO NOT SHOW A | | | BREAKROOM COUNTER AND SINK, A REFRIGERATOR, AND THE | | | DRINKING FOUNTAIN. AS PREVIOUSLY REQUESTED, PROVIDE | | | PLUMBING PLANS FOR THE NEW INSTALLATIONS. | | | 3. FAILED. SHEET 1.0A AND PLUMBING PLAN: LABEL THE | | | SUITE NUMBERS ON THE PLANS, AND LABEL THE RESTROOMS FOR | | | THE GYM OCCUPANCY AS EITHER MALE OR FEMALE- SECTIONS | | | 403.2 & 403.2.1 FBC P. PROVIDE A PLUMBING FIXTURE AND | | | DEVICE SCHEDULE ON THE PLAN- SECTION 107.2.1 WPB & | | | SECTION 405.9 FBC P. THE REQUESTED PLUMBING FIXTURE | | | SCHEDULE WAS NOT PROVIDED. NEW DETAILS HAVE BEEN | | | PROVIDED FOR ACCESSIBLE FIXTURES THAT SHALL BE IN | | | COMPLIANCE WITH THE FBC-17 ACCESSIBILITY CODE. PLEASE | | | PROVIDE THE CODE DATA AND PROVIDE AN ELEVATION AND SIDE | | | VIEW DRAWING OF THE NEW COUNTERTOP AND SINK- SECTIONS | | | 606.3 AND 309. | | | | | | 2) SHEET 1.0A: COMMENT #3K FROM THE PREVIOUS REVIEW | | | PRINTED BELOW STILL EXISTS. THE SMALLER OF THE TWO | | | RESTROOMS IN QUESTION IS NOW IDENTIFIED ON THE PLAN AS | | | EX. WOMEN. AS NOTED BELOW THE DOOR SHALL NOT SWING INTO | | | THE CLEAR FLOOR SPACE OF THE LAVATORY UNLESS MEETING | | | EXCEPTION 2 UNDER SECTION 603.2.3 FBC ACC. | | | K. FAILED. PLEASE NOTE: THE PLAN APPEARS TO SHOW THE | | | DOOR INTO THE SMALLER OF THE TWO RESTROOMS WILL SWING | | | INTO THE CLEAR FLOOR SPACE OF THE LAVATORY- SECTION | | | 603.2.3 FBC ACC. THE NEW ACCESSIBILITY DETAILS SHOW THE | | | DOOR SWINGING OUT WHICH DOES NOT MATCH THE FLOOR PLAN. | | | PLEASE SEE EXCEPTIONS UNDER SECTION 603.2.3. | | | | | | 3) SHEET 1.0A: COMMENT #7 FROM THE PREVIOUS REVIEW | | | STILL EXISTS. FIGURE G ON THE PLAN IS MISLABELED AS A | | | LATCH SIDE INSTEAD OF A HINGE SIDE APPROACH, BUT THE | | | MANEUVERING CLEARANCE FOR THE APPROACH SHOWN DOES NOT | | | MATCH THE FLOOR PLAN LAYOUT BECAUSE THE 22? CLEARANCE | | | AT THE HINGE SIDE HAS NOT BEEN PROVIDED. THERE APPEARS | | | TO BE APPROXIMATELY 3 OR 4 INCH CLEARANCE. FOR A | | | WHEELCHAIR TO USE THE FIGURE G APPROACH AS DEPICTED | | | WOULD REQUIRE THE WHEELCHAIR TO ENTER THE CORRIDOR AND | | | THEN TURN AROUND AND THERE IS INADEQUATE TURNING SPACE | | | AS REQUIRED BY SECTION 304.3 | | | 7. FAILED. 1.0A: SHOW THE MANEUVERING CLEARANCES AT THE | | | RESTROOM DOORS- REFER TO FIGURES 404.2.1 FBC ACC. | | | PROVIDE DIMENSIONS ON THE PLAN TO VERIFY COMPLIANCE. | | | CLEARANCE DIAGRAMS AND DIMENSIONS NOT PROVIDED. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2020-08-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-08-17 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-08-17 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2020-08-17 13:11:49 | 2ND REVIEW FBC-2017 PLUMBING | | | PERMIT- 20061112 | | | 8/17/2020 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | COMMENTS FROM THE 1ST REVIEW LISTED BELOW WILL BE | | | MARKED AS PASSED OR FAILED. ADDITIONAL NOTES IN CAPITOL | | | LETTERS ARE ADDED TO FAILED COMMENTS | | | | | | 1) FAILED. SHEET C-1: NO PLUMBING PLANS HAVE BEEN | | | SUBMITTED. INDICATE THE SUITE NUMBER BY THE ADDRESS AT | | | THE TOP OF THE PLAN SHEET- SECTION 107.2.1 WPB. THE | | | APPROVED PLANS UNDER PERMIT- 19051456 DO NOT SHOW A | | | BREAKROOM COUNTER AND SINK, A REFRIGERATOR, AND THE | | | DRINKING FOUNTAIN. AS PREVIOUSLY REQUESTED PROVIDE | | | PLUMBING PLANS FOR THE NEW INSTALLATIONS. | | | | | | 2) FAILED. C-1: CORRECT THE PLUMBING FIXTURE SCHEDULE | | | INDICATING A WATER COOLER TO INDICATE A DRINKING | | | FOUNTAIN, AND REFER TO SECTION 211.1.2 FBC ACC, AND | | | TABLE 404.3 FBC P- NO FEWER THAN TWO DRINKING FOUNTAINS | | | SHALL BE PROVIDED. ONE DRINKING FOUNTAIN SHALL COMPLY | | | WITH SECTIONS 602.1 & 602.6 FBC ACC, AND ONE SHALL | | | COMPLY WITH 602.7. SECTION 602.7 REQUIRES THAT SPOUT | | | OUTLETS FOR STANDING PERSONS SHALL BE 38 INCHES MINIMUM | | | AND 43 INCHES MAXIMUM FROM THE FINISHED FLOOR. REVISE | | | THE PLANS TO SHOW COMPLIANCE AND PROVIDE THESE DETAILS: | | | THE DETAILS BELOW ARE PASSED HOWEVER ONLY ONE DRINKING | | | FOUNTAIN IS SHOWN ON THE FLOOR PLANS, AND NO PLUMBING | | | PLANS HAVE BEEN PROVIDED. | | | A) PASSED. THE CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS | | | FOR FORWARD WHEELCHAIR APPROACH- SECTION 602.2. FBC | | | ACC. | | | B) PASSED. KNEE AND TOE CLEARANCES- SECTION 306. | | | C) PASSED. SPOUT HEIGHT AND SPOUT LOCATION- SECTION | | | 602.4 AND 602.5. | | | | | | 3) FAILED. SHEET 1.0A AND PLUMBING PLAN: LABEL THE | | | SUITE NUMBERS ON THE PLANS, AND LABEL THE RESTROOMS FOR | | | THE GYM OCCUPANCY AS EITHER MALE OR FEMALE- SECTIONS | | | 403.2 & 403.2.1 FBC P. PROVIDE A PLUMBING FIXTURE AND | | | DEVICE SCHEDULE ON THE PLAN- SECTION 107.2.1 WPB & | | | SECTION 405.9 FBC P. THE REQUESTED PLUMBING FIXTURE | | | SCHEDULE WAS NOT PROVIDED. NEW DETAILS HAVE BEEN | | | PROVIDED FOR ACCESSIBLE FIXTURES THAT SHALL BE IN | | | COMPLIANCE WITH THE FBC-17 ACCESSIBILITY CODE. PLEASE | | | PROVIDE THE CODE DATA AND PROVIDE AN ELEVATION AND SIDE | | | VIEW DRAWING OF THE NEW COUNTERTOP AND SINK- SECTIONS | | | 606.3 AND 309. | | | | | | 4) PASSED 4A- 4J. 1.0A: PROVIDE ENLARGED DIMENSIONED | | | DRAWINGS OF THE ACCESSIBLE RESTROOMS INDICATING: | | | A) CLEAR FLOOR SPACE DIMENSIONS FOR THE WATER CLOSETS- | | | SECTION 604.3 FBC ACC. | | | B) CLEAR FLOOR SPACE DIMENSIONS FOR THE LAVATORIES- | | | SECTION 606.2 | | | C) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE WALLS | | | OR PARTITIONS- SECTION 604.2. | | | D) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED | | | FLOORS- SECTION 604.4. | | | E) HEIGHTS OF THE FRONT RIM OF THE LAVATORY FROM THE | | | FINISHED FLOOR- SECTION 606.3 | | | F) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION | | | 306. | | | G) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB | | | BARS- SECTION 604.5 | | | H) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS- | | | SECTION 604.6. | | | I) LOCATIONS, CLEARANCES, AND MOUNTING HEIGHTS FOR | | | PAPER DISPENSERS- SECTION 604.7 | | | J) HEIGHTS OF THE MIRROR FROM THE FINISHED FLOOR TO THE | | | BOTTOM OF THE REFLECTIVE SURFACES- SECTION 603.3 | | | K) FAILED. PLEASE NOTE: THE PLAN APPEARS TO SHOW THE | | | DOOR INTO THE SMALLER OF THE TWO RESTROOMS WILL SWING | | | INTO THE CLEAR FLOOR SPACE OF THE LAVATORY- SECTION | | | 603.2.3 FBC ACC. THE NEW ACCESSIBILITY DETAILS SHOW THE | | | DOOR SWINGING OUT WHICH DOES NOT MATCH THE FLOOR PLAN. | | | PLEASE SEE EXCEPTIONS UNDER SECTION 603.2.3. | | | | | | 5) FAILED. 1.0A: SEE COMMENT 2 ABOVE AND SHOW THE | | | LOCATIONS OF THE REQUIRED DRINKING FOUNTAINS. IDENTIFY | | | ALL PLUMBING FIXTURES, APPLIANCES, AND EQUIPMENT SHOWN | | | ON THE PLANS AS EITHER NEW OR EXISTING- SECTION 107.2.1 | | | WPB. ONLY ONE DRINKING FOUNTAIN IS PROVIDED- TWO ARE | | | REQUIRED- SEE COMMENT 2. | | | | | | 6) PASSED. 1.0A AND PLUMBING PLAN: INDICATE HOW HOT | | | WATER IS BEING PROVIDED TO THE MOP SINK, AND HOW | | | TEMPERED WATER IS BEING PROVIDED TO THE LAVATORIES PER | | | SECTIONS 416.5 & 607.1 FBC P. PLEASE NOTE THAT TEMPERED | | | SHALL BE SUPPLIED THROUGH A WATER TEMPERATURE LIMITING | | | DEVICE THAT CONFORMS TO ASSE 1070- SECTION 607.1.2 FBC | | | P. | | | | | | 7) FAILED. 1.0A: SHOW THE MANEUVERING CLEARANCES AT THE | | | RESTROOM DOORS- REFER TO FIGURES 404.2.1 FBC ACC. | | | PROVIDE DIMENSIONS ON THE PLAN TO VERIFY COMPLIANCE. | | | CLEARANCE DIAGRAMS AND DIMENSIONS NOT PROVIDED. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-07-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-07-17 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-07-17 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2020-07-17 10:14:57 | 1ST REVIEW FBC-2017 PLUMBING | | | PERMIT- 20061112 | | | 7/17/2020 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET C-1: NO PLUMBING PLANS HAVE BEEN SUBMITTED. | | | INDICATE THE SUITE NUMBER BY THE ADDRESS AT THE TOP OF | | | THE PLAN SHEET- SECTION 107.2.1 WPB. | | | | | | 2) C-1: CORRECT THE PLUMBING FIXTURE SCHEDULE | | | INDICATING A WATER COOLER TO INDICATE A DRINKING | | | FOUNTAIN, AND REFER TO SECTION 211.1.2 FBC ACC, AND | | | TABLE 404.3 FBC P- NO FEWER THAN TWO DRINKING FOUNTAINS | | | SHALL BE PROVIDED. ONE DRINKING FOUNTAIN SHALL COMPLY | | | WITH SECTIONS 602.1 ? 602.6 FBC ACC, AND ONE SHALL | | | COMPLY WITH 602.7. SECTION 602.7 REQUIRES THAT SPOUT | | | OUTLETS FOR STANDING PERSONS SHALL BE 38 INCHES MINIMUM | | | AND 43 INCHES MAXIMUM FROM THE FINISHED FLOOR. REVISE | | | THE PLANS TO SHOW COMPLIANCE AND PROVIDE THESE DETAILS: | | | A) THE CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR | | | FORWARD WHEELCHAIR APPROACH- SECTION 602.2. FBC ACC. | | | B) KNEE AND TOE CLEARANCES- SECTION 306. | | | C) SPOUT HEIGHT AND SPOUT LOCATION- SECTION 602.4 AND | | | 602.5. | | | | | | 3) SHEET 1.0A AND PLUMBING PLAN: LABEL THE SUITE | | | NUMBERS ON THE PLANS, AND LABEL THE RESTROOMS FOR THE | | | GYM OCCUPANCY AS EITHER MALE OR FEMALE- SECTIONS 403.2 | | | & 403.2.1 FBC P. PROVIDE A PLUMBING FIXTURE AND DEVICE | | | SCHEDULE ON THE PLAN- SECTION 107.2.1 WPB & SECTION | | | 405.9 FBC P. | | | | | | 4) 1.0A: PROVIDE ENLARGED DIMENSIONED DRAWINGS OF THE | | | ACCESSIBLE RESTROOMS INDICATING: | | | A) CLEAR FLOOR SPACE DIMENSIONS FOR THE WATER CLOSETS- | | | SECTION 604.3 FBC ACC. | | | B) CLEAR FLOOR SPACE DIMENSIONS FOR THE LAVATORIES- | | | SECTION 606.2 | | | C) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE WALLS | | | OR PARTITIONS- SECTION 604.2. | | | D) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED | | | FLOORS- SECTION 604.4. | | | E) HEIGHTS OF THE FRONT RIM OF THE LAVATORY FROM THE | | | FINISHED FLOOR- SECTION 606.3 | | | F) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION | | | 306. | | | G) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB | | | BARS- SECTION 604.5 | | | H) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS- | | | SECTION 604.6. | | | I) LOCATIONS, CLEARANCES, AND MOUNTING HEIGHTS FOR | | | PAPER DISPENSERS- SECTION 604.7 | | | J) HEIGHTS OF THE MIRROR FROM THE FINISHED FLOOR TO THE | | | BOTTOM OF THE REFLECTIVE SURFACES- SECTION 603.3 | | | K) PLEASE NOTE: THE PLAN APPEARS TO SHOW THE DOOR INTO | | | THE SMALLER OF THE TWO RESTROOMS WILL SWING INTO THE | | | CLEAR FLOOR SPACE OF THE LAVATORY- SECTION 603.2.3 FBC | | | ACC. | | | | | | 5) 1.0A: SEE COMMENT 2 ABOVE AND SHOW THE LOCATIONS OF | | | THE REQUIRED DRINKING FOUNTAINS. IDENTIFY ALL PLUMBING | | | FIXTURES, APPLIANCES, AND EQUIPMENT SHOWN ON THE PLANS | | | AS EITHER NEW OR EXISTING- SECTION 107.2.1 WPB. | | | | | | 6) 1.0A AND PLUMBING PLAN: INDICATE HOW HOT WATER IS | | | BEING PROVIDED TO THE MOP SINK, AND HOW TEMPERED WATER | | | IS BEING PROVIDED TO THE LAVATORIES PER SECTIONS 416.5 | | | & 607.1 FBC P. PLEASE NOTE THAT TEMPERED SHALL BE | | | SUPPLIED THROUGH A WATER TEMPERATURE LIMITING DEVICE | | | THAT CONFORMS TO ASSE 1070- SECTION 607.1.2 FBC P. | | | IT APPEARS THE DOOR INTO THE SMALLER OF THE TWO | | | RESTROOMS WILL SWING INTO THE CLEAR FLOOR SPACE OF THE | | | LAVATORY- SECTION 603.2.3 FBC ACC. | | | | | | 7) 1.0A: SHOW THE MANEUVERING CLEARANCES AT THE | | | RESTROOM DOORS- REFER TO FIGURES 404.2.1 FBC ACC. | | | PROVIDE DIMENSIONS ON THE PLAN TO VERIFY COMPLIANCE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2020-10-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-10-06 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-10-06 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2020-09-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-09-22 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-09-22 |
Time |
08:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-09-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-09-11 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-11 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-08-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-08-18 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-08-18 |
Time |
08:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-07-15 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-15 |
Time |
08:09 |
Sent To |
|
|
| Notes |
|
|