Plan Review Details - Permit 20061121
Plan Review Stops For Permit 20061121
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2020-09-09 Cont ID  
Sent By jwitmer Date 2020-09-09 Time 11:47 Rev Time 0.00
Received By jwitmer Date 2020-09-09 Time 11:15 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2020-08-24 Cont ID  
Sent By jwitmer Date 2020-08-24 Time 16:28 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2020-08-24 16:27:27TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-07-06 Cont ID  
Sent By jwitmer Date 2020-07-06 Time 08:57 Rev Time 0.00
Received By medwards Date 2020-07-15 Time 08:06 Sent To  
Notes
2020-07-06 08:52:41ASBESTOS COMMERCIAL.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
 19120504
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2020-09-22 Cont ID  
Sent By jwitmer Date 2020-09-22 Time 08:31 Rev Time 0.00
Received By jwitmer Date 2020-09-22 Time 08:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2020-09-09 Cont ID  
Sent By jwitmer Date 2020-09-09 Time 13:15 Rev Time 0.00
Received By jwitmer Date 2020-09-09 Time 11:14 Sent To  
Notes
2020-09-09 13:19:04WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20061121
 ADD: 2711 EXCHANGE CT. SUITE: B
 CONT: EDMON WALSH CONSTRUCTION
 TEL: ???
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
 3RD REVIEW
 DATE: WED. SEPT. 09TH/ 2020
 ACTION: DENIED
  
 1) COMPLIED. 2017 FBC-ACCESSIBILITY CODE SECTION
 CLEARANCES AT WATER CLOSETS. 604.3 CLEARANCE.
  
 1A-1F) COMPLIED.
  
 1G) PLEASE ALSO REVIEW THE PLUMBING PLANS EXAMINERS
 COMMENTS IN REGARDS TO THE BREAK ROOM SINK AND PERMIT
 19051456.
 2ND ROUND COMMENT. THE BREAK ROOM ALSO SHOWS AS
 EXISTING, PLEASE SHOW HOW COMPLIANCE WITH SECTION 606
 SINKS. 2017 FBC-ACCESSIBILITY CODE SECTION 606.3
 HEIGHT. LAVATORIES AND SINKS SHALL BE INSTALLED WITH
 THE FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE
 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND.
  
 1H) RESPONSE DOES NOT ADDRESS RECEPTION DESK. THE PLANS
 SHOW A RECEPTION DESK PLEASE PROVIDE HOW COMPLIANCE
 WITH SECTIONS:
  
 CHECK WRITING SURFACES. 2017 ACCESS. CODE 904.3.3 CHECK
 WRITING SURFACES. WHERE PROVIDED, CHECK WRITING
 SURFACES SHALL COMPLY WITH 902.3. 902.3HEIGHT. THE TOPS
 OF WORK SURFACES SHALL BE 28 INCHES (710 MM) MINIMUM
 AND 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR
 OR GROUND.
 SHOW COMPLIANCE WITH THE ACCESS. CODE 305.5 POSITION.
 UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND SPACE
 SHALL BE POSITIONED FOR EITHER A FORWARD OR PARALLEL
 APPROACH TO AN ELEMENT.
  
 2) 2ND REQUEST, RESPONSE LETTER STATE NOTES ADDED TO
 FLOOR PLAN, FRP TO THE MOP SINK AREA AND TILE TO THE
 RESTROOM WALLS. RESPONSE DOES NOT INDICATE WHICH PLAN
 SHEET NOTES WERE ADDED BUT COULD NOT FIND THE NEW NOTES
 ON THE COVERSHEET, A1.0 OR A1.1.
 NEW COMMENT. PLEASE NOTE THIS IS A CHANGE OF
 INTERPRETATION FROM THE BUILDING OFFICIAL ROBERT BROWN.
 EPOXY PAINTED SURFACES NO LONGER IS APPROVED AS A
 NON-ABSORBENT SURFACE FOR SERVICE SINKS, URINALS AND
 WATER CLOSETS.
 2017 FBC-B 1210.2.2. WALLS & PARTITIONS. WALLS &
 PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS, AND
 WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NON-ABSORBENT
 SURFACE TO A HEIGHT OF NOT LESS THAN 4 FEET ABOVE THE
 FLOOR, EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIAL
 USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS NOT
 ADVERSELY AFFECTED BY MOISTURE.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-08-24 Cont ID  
Sent By jwitmer Date 2020-08-24 Time 16:28 Rev Time 0.00
Received By jwitmer Date 2020-08-24 Time 15:46 Sent To  
Notes
2020-08-24 16:25:34WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20061121
 ADD: 2711 EXCHANGE CT. SUITE: B
 CONT: EDMON WALSH CONSTRUCTION
 TEL: ???
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
 1D)
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
 2ND REVIEW
 DATE: MON. AUGUST 24TH/ 2020
 ACTION: DENIED
  
 1) 2ND REQUEST.SHEET 1 A1.01. THE 2 EXISTING RESTROOMS
 ARE NOT DIMENSIONED. THEY MAY OR MAY NOT COMPLY WITH
 THE 2017 FBC-ACCESSIBILITY CODE SECTION CLEARANCES AT
 WATER CLOSETS. 604.3 CLEARANCE. CLEARANCES AROUND THE
 WATER CLOSETS AND IN TOILET COMPARTMENTS SHALL COMPLY
 WITH 604.3.
 604.3.1. SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE
 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE
 WALL AND 56 INCHES MINIMUM PERPENDICULAR FROM THE REAR
 WALL. NOTE THE MINIMUM BACK WALL MEASUREMENT SHOULD BE
 7 FOOT 1 INCH.
  
 1A) UNDER THE 2017 EXISTING BUILDING CODE LEVEL II
 ALTERATIONS, SECTION 806.1 A BUILDING, FACILITY, OR
 ELEMENT THAT IS ALTERED SHALL COMPLY WITH THE
 PROVISIONS OF THE FLORIDA BUILDING CODE- ACCESSIBILITY.
 IN THE ACCESSIBILITY CODE IT REFERS YOU TO
 DISPROPORTIONATE COST.
  
 1B) DISPROPORTIONATE COST. PLEASE REVIEW HOW YOU ARE TO
 MEET DISPROPORTIONATE COST. EITHER THE CONTRACTOR OR
 THE DESIGNER OF RECORD ON THEIR LETTERHEAD NEED TO SHOW
 HOW THEY ARE GOING TO SPEND THE 20% DISPROPORTIONATE
 FUNDS LISTED FOR EACH ELEMENT WHERE THE FUNDS ARE BEING
 SPENT AND IN THE ORDER LISTED IN SECTION 202.4.1
 DISPROPORTIONATE COST OF THE 2017 ACCESSIBILITY CODE.
 YOU MAY HAVE TO SPEND UP TO AN ADDITIONAL $9.000.00
 DOLLARS IN VALUE TO BRING ONE OR BOTH RESTROOMS INTO
 COMPLIANCE.
  
 1C-G) COMPLIED.
  
  
 1H) THE PLANS SHOW A RECEPTION DESK PLEASE PROVIDE HOW
 COMPLIANCE WITH SECTIONS:
  
 CHECK WRITING SURFACES. 2017 ACCESS. CODE 904.3.3 CHECK
 WRITING SURFACES. WHERE PROVIDED, CHECK WRITING
 SURFACES SHALL COMPLY WITH 902.3. 902.3HEIGHT. THE TOPS
 OF WORK SURFACES SHALL BE 28 INCHES (710 MM) MINIMUM
 AND 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR
 OR GROUND.
 SHOW COMPLIANCE WITH THE ACCESS. CODE 305.5 POSITION.
 UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND SPACE
 SHALL BE POSITIONED FOR EITHER A FORWARD OR PARALLEL
 APPROACH TO AN ELEMENT.
  
 2) NEW COMMENT. PLEASE NOTE THIS IS A CHANGE OF
 INTERPRETATION FROM THE BUILDING OFFICIAL ROBRT BROWN.
 EPOXY PAINTED SURFACES NO LONGER IS APPROVED AS A
 NON-ABSORBANT SURFACE FOR SERVICE SINKS, URINALS AND
 WATER CLOSETS.
 2017 FBC-B 1210.2.2. WALLS & PARTITIONS. WALLS &
 PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS, AND
 WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NON-ABSORBENT
 SURFACE TO A HEIGHT OF NOT LESS THAN 4 FEET ABOVE THE
 FLOOR, EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIAL
 USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS NOT
 ADVERSELY AFFECTED BY MOISTURE.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-07-06 Cont ID  
Sent By jwitmer Date 2020-07-06 Time 08:58 Rev Time 0.00
Received By jwitmer Date 2020-07-06 Time 07:45 Sent To  
Notes
2020-07-06 08:50:10 
 WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20061121
 ADD: 2711 EXCHANGE CT. SUITE: B
 CONT: EDMON WALSH CONSTRUCTION
 TEL: ???
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
 1D)
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
 1ST REVIEW
 DATE: MON. JULY 09/ 2020
 ACTION: DENIED
  
 1) SHEET 1 A1.01. THE 2 EXISTING RESTROOMS ARE NOT
 DIMENSIONED. THEY MAY OR MAY NOT COMPLY WITH THE 2017
 FBC-ACCESSIBILITY CODE SECTION CLEARANCES AT WATER
 CLOSETS. 604.3 CLEARANCE. CLEARANCES AROUND THE WATER
 CLOSETS AND IN TOILET COMPARTMENTS SHALL COMPLY WITH
 604.3.
 604.3.1. SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE
 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE
 WALL AND 56 INCHES MINIMUM PERPENDICULAR FROM THE REAR
 WALL. NOTE THE MINIMUM BACK WALL MEASUREMENT SHOULD BE
 7 FOOT 1 INCH.
  
 1A) UNDER THE 2017 EXISTING BUILDING CODE LEVEL II
 ALTERATIONS, SECTION 806.1 A BUILDING, FACILITY, OR
 ELEMENT THAT IS ALTERED SHALL COMPLY WITH THE
 PROVISIONS OF THE FLORIDA BUILDING CODE- ACCESSIBILITY.
 IN THE ACCESSIBILITY CODE IT REFERS YOU TO
 DISPROPORTIONATE COST.
  
 1B) DISPROPORTIONATE COST. PLEASE REVIEW HOW YOU ARE TO
 MEET DISPROPORTIONATE COST. EITHER THE CONTRACTOR OR
 THE DESIGNER OF RECORD ON THEIR LETTERHEAD NEED TO SHOW
 HOW THEY ARE GOING TO SPEND THE 20% DISPROPORTIONATE
 FUNDS LISTED FOR EACH ELEMENT WHERE THE FUNDS ARE BEING
 SPENT AND IN THE ORDER LISTED IN SECTION 202.4.1
 DISPROPORTIONATE COST OF THE 2017 ACCESSIBILITY CODE.
 YOU MAY HAVE TO SPEND UP TO AN ADDITIONAL $9.000.00
 DOLLARS IN VALUE TO BRING ONE OR BOTH RESTROOMS INTO
 COMPLIANCE.
  
 1C) SINCE THERE MAYBE ADDITIONAL WORK TO THE RESTROOMS
 PLEASE PROVIDE ELEVATIONS TO DETERMINE CODE COMPLIANCE
 WITH THE ACCESSIBLE ELEMENTS WITHIN THE RESTROOMS,
 ELEMENTS LIKE BACKING, GRAB BARS, LOCATION OF THE WATER
 CLOSET, LAVS, MIRROR & TOILET PAPER HOLDERS ? 2017
 ACCESSIBILITY CODE CHAPTER 6.
 1D) IN THE HALL CORRIDOR THERE IS A NEW BI-FOLD DOOR
 MARKED # 5. THERE APPEARS TO BE A SINGLE WATER FOUNTAIN
 THAT THE BI-FOLD DOOR SWINGS INTO THE CLEAR FLOOR
 SPACE.
 1E) 2017 FBC-ACCESSIBILITY CODE. 211.2 MINIMUM NUMBER.
 NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED.
 ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH
 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH
 602.7.
 DRINKING FOUNTAINS TO SHOW COMPLIANCE WITH 307.2
 PROTRUSION LIMITS. OBJECTS WITH LEADING EDGES MORE THAN
 27 INCHES AND NOT MORE THAN 80 INCHES ABOVE THE FINISH
 FLOOR SHALL PROTRUDE 4 INCHES OR LESS MAXIMUM
 HORIZONTALLY INTO THE CIRCULATION PATH. SKIRTS MAYBE
 REQUIRED TO BE APPLIED TO THE BOTTOM OF THE DRINKING
 FOUNTAIN.
  
 1F) 606.2 CLEAR FLOOR SPACE DRINKING FOUNTAINS. A CLEAR
 FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR A
 FORWARD APPROACH, AND KNEE AND TOE CLEARANCE COMPLYING
 WITH 306 SHALL BE PROVIDED.
  
 1G) THE BREAK ROOM ALSO SHOWS AS EXISTING, PLEASE SHOW
 HOW COMPLIANCE WITH SECTION 606 SINKS. 2017
 FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT. LAVATORIES
 AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE
 HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES (865 MM)
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 1H) THE PLANS SHOW A RECEPTION DESK PLEASE PROVIDE HOW
 COMPLIANCE WITH SECTIONS:
  
 CHECK WRITING SURFACES. 2017 ACCESS. CODE 904.3.3 CHECK
 WRITING SURFACES. WHERE PROVIDED, CHECK WRITING
 SURFACES SHALL COMPLY WITH 902.3. 902.3HEIGHT. THE TOPS
 OF WORK SURFACES SHALL BE 28 INCHES (710 MM) MINIMUM
 AND 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR
 OR GROUND.
 SHOW COMPLIANCE WITH THE ACCESS. CODE 305.5 POSITION.
 UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND SPACE
 SHALL BE POSITIONED FOR EITHER A FORWARD OR PARALLEL
 APPROACH TO AN ELEMENT.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-09-11 Cont ID  
Sent By jleahy Date 2020-09-11 Time 14:19 Rev Time 0.00
Received By jleahy Date 2020-09-11 Time 14:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-08-27 Cont ID  
Sent By jleahy Date 2020-08-27 Time 09:46 Rev Time 0.00
Received By jleahy Date 2020-08-27 Time 09:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-07-22 Cont ID  
Sent By jleahy Date 2020-07-22 Time 12:49 Rev Time 0.00
Received By jleahy Date 2020-07-22 Time 12:49 Sent To  
Notes
2020-07-22 12:51:43ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 TREATMENT ROOMS? WHAT KIND OF TREATMENT? 517?
  
 PLEASE EXPLAIN FEEDER TAP ON RISER? HOW LONG IS TAP
 WHICH RULE DOES IT MEET? 240.21

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2020-09-17 Cont ID  
Sent By pleduc Date 2020-09-17 Time   Rev Time 0.00
Received By pleduc Date 2020-09-17 Time 13:24 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2020-09-03 Cont ID  
Sent By pleduc Date 2020-09-02 Time   Rev Time 0.00
Received By pleduc Date 2020-09-02 Time 14:53 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-08-14 Cont ID  
Sent By pleduc Date 2020-08-14 Time   Rev Time 0.00
Received By pleduc Date 2020-08-14 Time 11:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-07-02 Cont ID  
Sent By pleduc Date 2020-07-02 Time   Rev Time 0.00
Received By pleduc Date 2020-07-02 Time 10:10 Sent To  
Notes
2020-07-02 10:29:21THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE ARE INDICATIONS OF TREATMENT ROOMS.
  
 FOR A REVIEW OF THE PROPER OCCUPANCY CLASSIFICATION PER
 NFPA 101, PLEASE PROVIDE A BRIEF DESCIPTION OF WHAT THE
 NATURE OF THE OCCUPANCY. WHAT IS THE NATURE OF THE
 BUSINESS?
  
  
  
 2) COVER SHEET & 1.1A - THERE IS AN INDICATION OF THE
 OCCUPANCY AS BUSINESS, WITH A SQ FT OF 3082, AND AN
 OCCUPANCY LOAD OF 31. BASED ON THAT INFORMATION PER
 NFPA 101 CHAPTER 7, TABLE 7.3.1.2 THE OCCUPANCY LOAD
 FACTOR IS 50SQ FT / PERSON OR 62.
  
 HOWEVER, THERE ARE INDICATION OF TWO SPACES/ROOMS
 INDICATED AS GYM ON SHEET 1.1A. PER THE SAME TABLE A
 GYM WITH NO EQUIPMENT HAS A FACTOR OF 15 SQ FT/PERSON.
  
 PLEASE REVIEW AND CORRECT.
  
  
 3) SHEET 1.1A - THERE IS AN INDICATION OF THE FRONT
 EXIT PATH LEADING TO A DOOR THAT SWINGS IN. PER NFPA
 101, CH 7, THIS DOOR IS REQUIRED TO SWING IN THE PATH
 OF EGRESS.
  
 7.2.1.4.2 DOOR LEAF SWING DIRECTION. DOOR LEAVES
 REQUIRED TO BE
 OF THE SIDE-HINGED OR PIVOTED-SWINGING TYPE SHALL SWING
 IN THE
 DIRECTION OF EGRESS TRAVEL UNDER ANY OF THE FOLLOWING
 CONDITIONS:
 (1) WHERE SERVING A ROOM OR AREA WITH AN OCCUPANT LOAD
 OF 50 OR
 MORE, EXCEPT UNDER ANY OF THE FOLLOWING CONDITIONS:
 (A) DOOR LEAVES IN HORIZONTAL EXITS SHALL NOT BE
 REQUIRED TO
 SWING IN THE DIRECTION OF EGRESS TRAVEL WHERE PERMITTED
 BY 7.2.4.3.8.1 OR 7.2.4.3.8.2.
 (B) DOOR LEAVES IN SMOKE BARRIERS SHALL NOT BE REQUIRED
 TO
 SWING IN THE DIRECTION OF EGRESS TRAVEL IN EXISTING
 HEALTH
 CARE OCCUPANCIES, AS PROVIDED IN CHAPTER 19.
 (2) WHERE THE DOOR ASSEMBLY IS USED IN AN EXIT
 ENCLOSURE, UNLESS
 THE DOOR OPENING SERVES AN INDIVIDUAL LIVING UNIT THAT
 OPENS
 DIRECTLY INTO AN EXIT ENCLOSURE
 (3) WHERE THE DOOR OPENING SERVES A HIGH HAZARD
 CONTENTS AREA
  
 PLEASE REVIEW AND CORRECT.
  
  
 4) SHEET 1.1A - THE PLAN SHEET INDICATES A FRONT EXIT
 DOOR BUT IT DOES NOT INDICATE WHERE THAT FRONT EXIT
 LEADS TO OR WHETHER THAT IS A PROTECTED EXIT PATH TO
  
 PER NFPA 101 CH 7
  
 7.7 DISCHARGE FROM EXITS.
 7.7.1* EXIT TERMINATION. EXITS SHALL TERMINATE
 DIRECTLY, AT A PUBLIC
 WAY OR AT AN EXTERIOR EXIT DISCHARGE, UNLESS OTHERWISE
 PROVIDED IN
 7.7.1.2 THROUGH 7.7.1.4.
 7.7.1.1 YARDS, COURTS, OPEN SPACES, OR OTHER PORTIONS
 OF THE EXIT
 DISCHARGE SHALL BE OF THE REQUIRED WIDTH AND SIZE TO
 PROVIDE ALL
 OCCUPANTS WITH A SAFE ACCESS TO A PUBLIC WAY.
 7.7.1.2 THE REQUIREMENT OF 7.7.1 SHALL NOT APPLY TO
 INTERIOR EXIT
 DISCHARGE AS OTHERWISE PROVIDED IN 7.7.2.
 7.7.2 EXIT DISCHARGE THROUGH INTERIOR BUILDING AREAS.
 EXITS SHALL
 BE PERMITTED TO DISCHARGE THROUGH INTERIOR BUILDING
 AREAS, PROVIDED
 THAT ALL OF THE FOLLOWING ARE MET:
 (1) NOT MORE THAN 50 PERCENT OF THE REQUIRED NUMBER OF
 EXIT STAIRS
 SERVING NORMALLY OCCUPIED AREAS OF EACH FLOOR, AND NOT
 MORE
 THAN 50 PERCENT OF THE EXIT STAIR CAPACITY REQUIRED FOR
 NORMALLY
 OCCUPIED AREAS OF EACH FLOOR, SHALL DISCHARGE THROUGH
 AREAS ON
 ANY LEVEL OF DISCHARGE, EXCEPT AS OTHERWISE PERMITTED
 BY ONE OF
 THE FOLLOWING:
 (A) ONE HUNDRED PERCENT OF THE EXITS SHALL BE PERMITTED
 TO
 DISCHARGE THROUGH AREAS ON ANY LEVEL OF DISCHARGE IN
 DETENTION AND CORRECTIONAL OCCUPANCIES AS OTHERWISE
 PROVIDED IN CHAPTERS 22 AND 23.
 (B) IN EXISTING BUILDINGS, THE 50 PERCENT LIMIT ON
 EGRESS
 CAPACITY SHALL NOT APPLY IF THE 50 PERCENT LIMIT ON THE
 REQUIRED NUMBER OF EXITS IS MET.
 (2) EACH LEVEL OF DISCHARGE SHALL DISCHARGE DIRECTLY
 OUTSIDE AT THE
 FINISHED GROUND LEVEL OR DISCHARGE DIRECTLY OUTSIDE AND
 PROVIDE
 ACCESS TO THE FINISHED GROUND LEVEL BY OUTSIDE STAIRS
 OR OUTSIDE
 RAMPS.
 (3) THE INTERIOR EXIT DISCHARGE SHALL LEAD TO A FREE
 AND UNOBSTRUCTED
 WAY TO THE EXTERIOR OF THE BUILDING, AND SUCH WAY SHALL
 BE READILY
 VISIBLE AND IDENTIFIABLE FROM THE POINT OF DISCHARGE
 FROM THE EXIT
 (4) THE INTERIOR EXIT DISCHARGE SHALL BE PROTECTED BY
 ONE OF THE
 FOLLOWING METHODS:
 (A) THE LEVEL OF DISCHARGE SHALL BE PROTECTED
 THROUGHOUT BY AN
 APPROVED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH
 SECTION 9.7, OR THE PORTION OF THE LEVEL OF DISCHARGE
 USED FOR
 INTERIOR EXIT DISCHARGE SHALL BE PROTECTED BY AN
 APPROVED
 AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION
 9.7
 AND SHALL BE SEPARATED FROM THE NONSPRINKLERED PORTION
 OF
 THE FLOOR BY FIRE BARRIERS WITH A FIRE RESISTANCE
 RATING
 MEETING THE REQUIREMENTS FOR THE ENCLOSURE OF EXITS.
 (SEE
 7.1.3.2.1.)
 (B) THE INTERIOR EXIT DISCHARGE AREA SHALL BE IN A
 VESTIBULE OR
 FOYER THAT MEETS ALL OF THE FOLLOWING CRITERIA:
 I. THE DEPTH FROM THE EXTERIOR OF THE BUILDING SHALL BE
 NOT MORE THAN 10 FT (3050 MM), AND THE LENGTH SHALL
 BE NOT MORE THAN 30 FT (9.1 M).
 II. THE FOYER SHALL BE SEPARATED FROM THE REMAINDER OF
 THE
 LEVEL OF DISCHARGE BY FIRE BARRIERS WITH A MINIMUM 1-
 HOUR FIRE RESISTANCE RATING, AND EXISTING INSTALLATIONS
 OF
 WIRED GLASS IN STEEL FRAMES SHALL BE PERMITTED TO BE
 CONTINUED IN USE.
 III. THE FOYER SHALL SERVE ONLY AS MEANS OF EGRESS AND
 SHALL INCLUDE AN EXIT DIRECTLY TO THE OUTSIDE.
 (5) THE ENTIRE AREA ON THE LEVEL OF DISCHARGE SHALL BE
 SEPARATED FROM
 AREAS BELOW BY CONSTRUCTION HAVING A FIRE RESISTANCE
 RATING NOT
 LESS THAN THAT REQUIRED FOR THE EXIT ENCLOSURE, UNLESS
 OTHERWISE
 PROVIDED IN 7.7.2(6).
 (6) LEVELS BELOW THE LEVEL OF DISCHARGE IN AN ATRIUM
 SHALL BE
 PERMITTED TO BE OPEN TO THE LEVEL OF DISCHARGE WHERE
 SUCH LEVEL
 OF DISCHARGE IS PROTECTED IN ACCORDANCE WITH 8.6.7.
  
  
 PLEASE REVIEW, SHOW THE ENTIRE EXIT PATH ON THE PLAN
 SHEET AND PROVIDE FOR COMPLIANCE WITH THE REQUIREMENTS.
  
  
  
 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2020-10-07 Cont ID  
Sent By medwards Date 2020-10-07 Time 07:35 Rev Time 0.00
Received By medwards Date 2020-10-05 Time 07:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-09-22 Cont ID  
Sent By jwitmer Date 2020-09-22 Time 08:31 Rev Time 0.00
Received By jwitmer Date 2020-09-16 Time 16:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-09-11 Cont ID  
Sent By jleahy Date 2020-09-11 Time 14:16 Rev Time 0.00
Received By jleahy Date 2020-09-01 Time 15:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-27 Cont ID  
Sent By jleahy Date 2020-08-27 Time 09:47 Rev Time 0.00
Received By jleahy Date 2020-08-13 Time 08:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-07-22 Cont ID  
Sent By jleahy Date 2020-07-22 Time 12:51 Rev Time 0.00
Received By jleahy Date 2020-07-01 Time 15:59 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2020-10-07 Cont ID  
Sent By medwards Date 2020-10-07 Time 07:34 Rev Time 0.00
Received By medwards Date 2020-10-07 Time 07:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2020-09-09 Cont ID  
Sent By medwards Date 2020-09-09 Time 11:01 Rev Time 0.00
Received By medwards Date 2020-09-09 Time 10:51 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-08-18 Cont ID  
Sent By medwards Date 2020-08-18 Time 08:19 Rev Time 0.00
Received By medwards Date 2020-08-18 Time 07:13 Sent To  
Notes
2020-08-18 08:19:222ND REVIEW FBC-2017 MECHANICAL
 PERMIT-20061121
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE SEE 1ST CYCLE REVIEW COMMENTS, THE ADDRESS IS
 STILL NOT CORRECT. PLEASE INCLUDE SUITE NUMBER FBC FS
 107.2.1
  
 2) PERMIT 19051456- SHOWS THE CONVERTING OF 1 LARGE
 SPACE INTO 2 NEW TENANT SPACES. IT DOES NOT HOW EVER
 SHOW ANY MECHANICAL WORK FOR SUITE B IF THIS PROJECT IS
 FOR SUITE B PLEASE SHOW ALL NEW DUCT WORK FOR THE NEW
 ROOMS BUILT. FBC FS 107.2.1
  
 3) PLEASE PROVIDE A VENTILATION CALCULATION FOR THIS
 SPACE. FBC M 403
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-07-15 Cont ID  
Sent By medwards Date 2020-07-15 Time 08:07 Rev Time 0.00
Received By medwards Date 2020-07-15 Time 08:07 Sent To  
Notes
2020-07-15 08:09:031ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20061121
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE CORRECT ADDRESS ON BOTH THE PLANS AND
 THE APPLICATION. THEY HAVE DIFFERENT ADDRESSES ON EACH
 AND I COULD NOT GET EITHER TO COME UP IN OUR GIS
 PROGRAM. FBC FS 107.2.1
  
 2) PLEASE PROVIDE A VENTILATION CALCULATION FOR EACH
 AREA OF TENANT SPACE. FBC M TABLE 403.3.1.1
  
 3) PLEASE PROVIDE INFORMATION ON EXISTING RTU?S WITH
 THE VENTILATION CALCULATIONS. FBC FS 107.2.1
  
  
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 5 Status P Date 2020-10-06 Cont ID  
Sent By ccole Date 2020-10-06 Time 10:01 Rev Time 0.00
Received By ccole Date 2020-10-06 Time 07:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2020-09-17 Cont ID  
Sent By ccole Date 2020-09-17 Time 11:54 Rev Time 0.00
Received By ccole Date 2020-09-17 Time 07:48 Sent To  
Notes
2020-09-17 11:54:414TH REVIEW FBC-2017 PLUMBING
 PERMIT- 20061121`
 9/17/2020
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET 3.0MP: THE WASTE FROM THE SINK PUMP CANNOT
 DRAIN INTO THE INDIVIDUAL FIXTURE VENT FOR THE MOP
 SINK- SECTIONS 712.3.5 AND 905.1 FBC P. IF THE
 INTENTION IS TO SHOW A CONNECTION INTO A WASTE STACK,
 THEN THE WASTE STACK SHALL RUN VERTICALLY FROM THE
 HORIZONTAL DRAIN, AND THE MOP SINK AND KITCHEN SINK
 FIXTURE DRAINS WOULD EACH CONNECT INDIVIDUALLY INTO THE
 WASTE STACK. THIS MAY NOT BE POSSIBLE IF THE
 CONFIGURATION OF THE MOP SINK VENT IS ACCURATELY SHOWN
 AND YOU ARE ATTEMPTING TO TURN THE VENT INTO A WASTE
 STACK; OR IF THE FIXTURE DRAIN CONNECTS HORIZONTALLY TO
 THE DRAIN BELOW THE SLAB, THE VENT MUST BE MAINTAINED
 OPEN TO THE AIR WITHOUT ANY OTHER WASTE DISCHARGE INTO
 IT. ULTIMATELY A SEPARATE WASTE STACK MAY HAVE TO BE
 INSTALLED TO ACCOMMODATE THE KITCHEN SINK. PLEASE NOTE
 THE STACK VENT ABOVE SHALL BE THE SAME DIAMETER AS THE
 WASTE STACK- SEE SECTIONS 913.1- 913.4 FBC P AND
 CORRECT THE DRAWINGS.
  
 2) 3.0MP: PLEASE SUBMIT MANUFACTURER?S SPECIFICATIONS
 AND THE INSTALL GUIDELINES FOR THE LIBERTY 405 SUMP
 PUMP INCLUDING PUMP CURVE. PROVIDE TDH (TOTAL DYNAMIC
 HEAD) CALCULATION ON THE PLAN TO VERIFY ACCURATE SIZING
 OF THE PUMP ACCORDING TO THE CURVE- SECTION 712.3.1 FBC
 P.
  
 3) 3.0MP: SHOW ON THE DRAWINGS THE LOCATIONS OF THE
 REQUIRED CHECK VALVE AND FULL OPEN VALVE ON THE
 DISCHARGE PIPING OF THE PUMP BETWEEN THE PUMP AND THE
 GRAVITY DRAIN. SHOW HOW ACCESS FOR WILL BE PROVIDED TO
 THE VALVES- SECTION 712.2 FBC P.
  
 4) SHEET 1.0A: CONCERNING THE BREAKROOM THE
 ARCHITECTURAL AND MEP WORK PERFORMED IN THE ROOM CANNOT
 BE LABELED AS EXISTING IF NEVER LEGALLY PERMITTED. THE
 PLAN SHALL BE REVIEWED AND PERMITTED AS NEW IF THERE IS
 NO EVIDENCE OF A PERMIT OR INSPECTIONS ON RECORD FOR
 THE WORK PERFORMED. IT HAS ALREADY BEEN ESTABLISHED
 THAT THE PREVIOUS PERMIT PLANS UNDER 19051456 DID NOT
 SHOW THE BREAKROOM.
  
 5) 2.0E: A REVISION TO THE APPROVED ELECTRICAL PLAN IS
 REQUIRED TO PROVIDE A RECEPTACLE UNDER THE SINK FOR THE
 SUMP PUMP- SECTION 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status F Date 2020-09-09 Cont ID  
Sent By ccole Date 2020-09-09 Time 09:45 Rev Time 0.00
Received By ccole Date 2020-09-09 Time 07:19 Sent To  
Notes
2020-09-09 09:47:413RD REVIEW FBC-2017 PLUMBING
 PERMIT- 20061112
 9/9/2020
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET 1.0A: THE NOTE AT THE BREAKROOM INDICATES THE
 SINK WAS INSPECTED UNDER PERMIT #19051456. THE RECORD
 DRAWINGS THAT ARE ON FILE FOR THE PERMIT DO NOT SHOW A
 BREAKROOM OR SINK AT THAT LOCATION. AS PREVIOUSLY NOTED
 IN COMMENTS #1 & 3 PRINTED BELOW, PLUMBING PIPING AND
 ACCESSIBILITY DRAWINGS AND DETAILS ARE REQUIRED.
 1. FAILED. SHEET C-1: NO PLUMBING PLANS HAVE BEEN
 SUBMITTED. INDICATE THE SUITE NUMBER BY THE ADDRESS AT
 THE TOP OF THE PLAN SHEET- SECTION 107.2.1 WPB. THE
 APPROVED PLANS UNDER PERMIT- 19051456 DO NOT SHOW A
 BREAKROOM COUNTER AND SINK, A REFRIGERATOR, AND THE
 DRINKING FOUNTAIN. AS PREVIOUSLY REQUESTED, PROVIDE
 PLUMBING PLANS FOR THE NEW INSTALLATIONS.
 3. FAILED. SHEET 1.0A AND PLUMBING PLAN: LABEL THE
 SUITE NUMBERS ON THE PLANS, AND LABEL THE RESTROOMS FOR
 THE GYM OCCUPANCY AS EITHER MALE OR FEMALE- SECTIONS
 403.2 & 403.2.1 FBC P. PROVIDE A PLUMBING FIXTURE AND
 DEVICE SCHEDULE ON THE PLAN- SECTION 107.2.1 WPB &
 SECTION 405.9 FBC P. THE REQUESTED PLUMBING FIXTURE
 SCHEDULE WAS NOT PROVIDED. NEW DETAILS HAVE BEEN
 PROVIDED FOR ACCESSIBLE FIXTURES THAT SHALL BE IN
 COMPLIANCE WITH THE FBC-17 ACCESSIBILITY CODE. PLEASE
 PROVIDE THE CODE DATA AND PROVIDE AN ELEVATION AND SIDE
 VIEW DRAWING OF THE NEW COUNTERTOP AND SINK- SECTIONS
 606.3 AND 309.
  
 2) SHEET 1.0A: COMMENT #3K FROM THE PREVIOUS REVIEW
 PRINTED BELOW STILL EXISTS. THE SMALLER OF THE TWO
 RESTROOMS IN QUESTION IS NOW IDENTIFIED ON THE PLAN AS
 EX. WOMEN. AS NOTED BELOW THE DOOR SHALL NOT SWING INTO
 THE CLEAR FLOOR SPACE OF THE LAVATORY UNLESS MEETING
 EXCEPTION 2 UNDER SECTION 603.2.3 FBC ACC.
 K. FAILED. PLEASE NOTE: THE PLAN APPEARS TO SHOW THE
 DOOR INTO THE SMALLER OF THE TWO RESTROOMS WILL SWING
 INTO THE CLEAR FLOOR SPACE OF THE LAVATORY- SECTION
 603.2.3 FBC ACC. THE NEW ACCESSIBILITY DETAILS SHOW THE
 DOOR SWINGING OUT WHICH DOES NOT MATCH THE FLOOR PLAN.
 PLEASE SEE EXCEPTIONS UNDER SECTION 603.2.3.
  
 3) SHEET 1.0A: COMMENT #7 FROM THE PREVIOUS REVIEW
 STILL EXISTS. FIGURE G ON THE PLAN IS MISLABELED AS A
 LATCH SIDE INSTEAD OF A HINGE SIDE APPROACH, BUT THE
 MANEUVERING CLEARANCE FOR THE APPROACH SHOWN DOES NOT
 MATCH THE FLOOR PLAN LAYOUT BECAUSE THE 22? CLEARANCE
 AT THE HINGE SIDE HAS NOT BEEN PROVIDED. THERE APPEARS
 TO BE APPROXIMATELY 3 OR 4 INCH CLEARANCE. FOR A
 WHEELCHAIR TO USE THE FIGURE G APPROACH AS DEPICTED
 WOULD REQUIRE THE WHEELCHAIR TO ENTER THE CORRIDOR AND
 THEN TURN AROUND AND THERE IS INADEQUATE TURNING SPACE
 AS REQUIRED BY SECTION 304.3
 7. FAILED. 1.0A: SHOW THE MANEUVERING CLEARANCES AT THE
 RESTROOM DOORS- REFER TO FIGURES 404.2.1 FBC ACC.
 PROVIDE DIMENSIONS ON THE PLAN TO VERIFY COMPLIANCE.
 CLEARANCE DIAGRAMS AND DIMENSIONS NOT PROVIDED.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-08-17 Cont ID  
Sent By ccole Date 2020-08-17 Time 13:11 Rev Time 0.00
Received By ccole Date 2020-08-17 Time 10:56 Sent To  
Notes
2020-08-17 13:11:492ND REVIEW FBC-2017 PLUMBING
 PERMIT- 20061112
 8/17/2020
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
 COMMENTS FROM THE 1ST REVIEW LISTED BELOW WILL BE
 MARKED AS PASSED OR FAILED. ADDITIONAL NOTES IN CAPITOL
 LETTERS ARE ADDED TO FAILED COMMENTS
  
 1) FAILED. SHEET C-1: NO PLUMBING PLANS HAVE BEEN
 SUBMITTED. INDICATE THE SUITE NUMBER BY THE ADDRESS AT
 THE TOP OF THE PLAN SHEET- SECTION 107.2.1 WPB. THE
 APPROVED PLANS UNDER PERMIT- 19051456 DO NOT SHOW A
 BREAKROOM COUNTER AND SINK, A REFRIGERATOR, AND THE
 DRINKING FOUNTAIN. AS PREVIOUSLY REQUESTED PROVIDE
 PLUMBING PLANS FOR THE NEW INSTALLATIONS.
  
 2) FAILED. C-1: CORRECT THE PLUMBING FIXTURE SCHEDULE
 INDICATING A WATER COOLER TO INDICATE A DRINKING
 FOUNTAIN, AND REFER TO SECTION 211.1.2 FBC ACC, AND
 TABLE 404.3 FBC P- NO FEWER THAN TWO DRINKING FOUNTAINS
 SHALL BE PROVIDED. ONE DRINKING FOUNTAIN SHALL COMPLY
 WITH SECTIONS 602.1 & 602.6 FBC ACC, AND ONE SHALL
 COMPLY WITH 602.7. SECTION 602.7 REQUIRES THAT SPOUT
 OUTLETS FOR STANDING PERSONS SHALL BE 38 INCHES MINIMUM
 AND 43 INCHES MAXIMUM FROM THE FINISHED FLOOR. REVISE
 THE PLANS TO SHOW COMPLIANCE AND PROVIDE THESE DETAILS:
 THE DETAILS BELOW ARE PASSED HOWEVER ONLY ONE DRINKING
 FOUNTAIN IS SHOWN ON THE FLOOR PLANS, AND NO PLUMBING
 PLANS HAVE BEEN PROVIDED.
 A) PASSED. THE CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS
 FOR FORWARD WHEELCHAIR APPROACH- SECTION 602.2. FBC
 ACC.
 B) PASSED. KNEE AND TOE CLEARANCES- SECTION 306.
 C) PASSED. SPOUT HEIGHT AND SPOUT LOCATION- SECTION
 602.4 AND 602.5.
  
 3) FAILED. SHEET 1.0A AND PLUMBING PLAN: LABEL THE
 SUITE NUMBERS ON THE PLANS, AND LABEL THE RESTROOMS FOR
 THE GYM OCCUPANCY AS EITHER MALE OR FEMALE- SECTIONS
 403.2 & 403.2.1 FBC P. PROVIDE A PLUMBING FIXTURE AND
 DEVICE SCHEDULE ON THE PLAN- SECTION 107.2.1 WPB &
 SECTION 405.9 FBC P. THE REQUESTED PLUMBING FIXTURE
 SCHEDULE WAS NOT PROVIDED. NEW DETAILS HAVE BEEN
 PROVIDED FOR ACCESSIBLE FIXTURES THAT SHALL BE IN
 COMPLIANCE WITH THE FBC-17 ACCESSIBILITY CODE. PLEASE
 PROVIDE THE CODE DATA AND PROVIDE AN ELEVATION AND SIDE
 VIEW DRAWING OF THE NEW COUNTERTOP AND SINK- SECTIONS
 606.3 AND 309.
  
 4) PASSED 4A- 4J. 1.0A: PROVIDE ENLARGED DIMENSIONED
 DRAWINGS OF THE ACCESSIBLE RESTROOMS INDICATING:
 A) CLEAR FLOOR SPACE DIMENSIONS FOR THE WATER CLOSETS-
 SECTION 604.3 FBC ACC.
 B) CLEAR FLOOR SPACE DIMENSIONS FOR THE LAVATORIES-
 SECTION 606.2
 C) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE WALLS
 OR PARTITIONS- SECTION 604.2.
 D) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED
 FLOORS- SECTION 604.4.
 E) HEIGHTS OF THE FRONT RIM OF THE LAVATORY FROM THE
 FINISHED FLOOR- SECTION 606.3
 F) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION
 306.
 G) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB
 BARS- SECTION 604.5
 H) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS-
 SECTION 604.6.
 I) LOCATIONS, CLEARANCES, AND MOUNTING HEIGHTS FOR
 PAPER DISPENSERS- SECTION 604.7
 J) HEIGHTS OF THE MIRROR FROM THE FINISHED FLOOR TO THE
 BOTTOM OF THE REFLECTIVE SURFACES- SECTION 603.3
 K) FAILED. PLEASE NOTE: THE PLAN APPEARS TO SHOW THE
 DOOR INTO THE SMALLER OF THE TWO RESTROOMS WILL SWING
 INTO THE CLEAR FLOOR SPACE OF THE LAVATORY- SECTION
 603.2.3 FBC ACC. THE NEW ACCESSIBILITY DETAILS SHOW THE
 DOOR SWINGING OUT WHICH DOES NOT MATCH THE FLOOR PLAN.
 PLEASE SEE EXCEPTIONS UNDER SECTION 603.2.3.
  
 5) FAILED. 1.0A: SEE COMMENT 2 ABOVE AND SHOW THE
 LOCATIONS OF THE REQUIRED DRINKING FOUNTAINS. IDENTIFY
 ALL PLUMBING FIXTURES, APPLIANCES, AND EQUIPMENT SHOWN
 ON THE PLANS AS EITHER NEW OR EXISTING- SECTION 107.2.1
 WPB. ONLY ONE DRINKING FOUNTAIN IS PROVIDED- TWO ARE
 REQUIRED- SEE COMMENT 2.
  
 6) PASSED. 1.0A AND PLUMBING PLAN: INDICATE HOW HOT
 WATER IS BEING PROVIDED TO THE MOP SINK, AND HOW
 TEMPERED WATER IS BEING PROVIDED TO THE LAVATORIES PER
 SECTIONS 416.5 & 607.1 FBC P. PLEASE NOTE THAT TEMPERED
 SHALL BE SUPPLIED THROUGH A WATER TEMPERATURE LIMITING
 DEVICE THAT CONFORMS TO ASSE 1070- SECTION 607.1.2 FBC
 P.
  
 7) FAILED. 1.0A: SHOW THE MANEUVERING CLEARANCES AT THE
 RESTROOM DOORS- REFER TO FIGURES 404.2.1 FBC ACC.
 PROVIDE DIMENSIONS ON THE PLAN TO VERIFY COMPLIANCE.
 CLEARANCE DIAGRAMS AND DIMENSIONS NOT PROVIDED.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-07-17 Cont ID  
Sent By ccole Date 2020-07-17 Time 10:14 Rev Time 0.00
Received By ccole Date 2020-07-17 Time 08:44 Sent To  
Notes
2020-07-17 10:14:571ST REVIEW FBC-2017 PLUMBING
 PERMIT- 20061112
 7/17/2020
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET C-1: NO PLUMBING PLANS HAVE BEEN SUBMITTED.
 INDICATE THE SUITE NUMBER BY THE ADDRESS AT THE TOP OF
 THE PLAN SHEET- SECTION 107.2.1 WPB.
  
 2) C-1: CORRECT THE PLUMBING FIXTURE SCHEDULE
 INDICATING A WATER COOLER TO INDICATE A DRINKING
 FOUNTAIN, AND REFER TO SECTION 211.1.2 FBC ACC, AND
 TABLE 404.3 FBC P- NO FEWER THAN TWO DRINKING FOUNTAINS
 SHALL BE PROVIDED. ONE DRINKING FOUNTAIN SHALL COMPLY
 WITH SECTIONS 602.1 ? 602.6 FBC ACC, AND ONE SHALL
 COMPLY WITH 602.7. SECTION 602.7 REQUIRES THAT SPOUT
 OUTLETS FOR STANDING PERSONS SHALL BE 38 INCHES MINIMUM
 AND 43 INCHES MAXIMUM FROM THE FINISHED FLOOR. REVISE
 THE PLANS TO SHOW COMPLIANCE AND PROVIDE THESE DETAILS:
 A) THE CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR
 FORWARD WHEELCHAIR APPROACH- SECTION 602.2. FBC ACC.
 B) KNEE AND TOE CLEARANCES- SECTION 306.
 C) SPOUT HEIGHT AND SPOUT LOCATION- SECTION 602.4 AND
 602.5.
  
 3) SHEET 1.0A AND PLUMBING PLAN: LABEL THE SUITE
 NUMBERS ON THE PLANS, AND LABEL THE RESTROOMS FOR THE
 GYM OCCUPANCY AS EITHER MALE OR FEMALE- SECTIONS 403.2
 & 403.2.1 FBC P. PROVIDE A PLUMBING FIXTURE AND DEVICE
 SCHEDULE ON THE PLAN- SECTION 107.2.1 WPB & SECTION
 405.9 FBC P.
  
 4) 1.0A: PROVIDE ENLARGED DIMENSIONED DRAWINGS OF THE
 ACCESSIBLE RESTROOMS INDICATING:
 A) CLEAR FLOOR SPACE DIMENSIONS FOR THE WATER CLOSETS-
 SECTION 604.3 FBC ACC.
 B) CLEAR FLOOR SPACE DIMENSIONS FOR THE LAVATORIES-
 SECTION 606.2
 C) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE WALLS
 OR PARTITIONS- SECTION 604.2.
 D) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED
 FLOORS- SECTION 604.4.
 E) HEIGHTS OF THE FRONT RIM OF THE LAVATORY FROM THE
 FINISHED FLOOR- SECTION 606.3
 F) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION
 306.
 G) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB
 BARS- SECTION 604.5
 H) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS-
 SECTION 604.6.
 I) LOCATIONS, CLEARANCES, AND MOUNTING HEIGHTS FOR
 PAPER DISPENSERS- SECTION 604.7
 J) HEIGHTS OF THE MIRROR FROM THE FINISHED FLOOR TO THE
 BOTTOM OF THE REFLECTIVE SURFACES- SECTION 603.3
 K) PLEASE NOTE: THE PLAN APPEARS TO SHOW THE DOOR INTO
 THE SMALLER OF THE TWO RESTROOMS WILL SWING INTO THE
 CLEAR FLOOR SPACE OF THE LAVATORY- SECTION 603.2.3 FBC
 ACC.
  
 5) 1.0A: SEE COMMENT 2 ABOVE AND SHOW THE LOCATIONS OF
 THE REQUIRED DRINKING FOUNTAINS. IDENTIFY ALL PLUMBING
 FIXTURES, APPLIANCES, AND EQUIPMENT SHOWN ON THE PLANS
 AS EITHER NEW OR EXISTING- SECTION 107.2.1 WPB.
  
 6) 1.0A AND PLUMBING PLAN: INDICATE HOW HOT WATER IS
 BEING PROVIDED TO THE MOP SINK, AND HOW TEMPERED WATER
 IS BEING PROVIDED TO THE LAVATORIES PER SECTIONS 416.5
 & 607.1 FBC P. PLEASE NOTE THAT TEMPERED SHALL BE
 SUPPLIED THROUGH A WATER TEMPERATURE LIMITING DEVICE
 THAT CONFORMS TO ASSE 1070- SECTION 607.1.2 FBC P.
 IT APPEARS THE DOOR INTO THE SMALLER OF THE TWO
 RESTROOMS WILL SWING INTO THE CLEAR FLOOR SPACE OF THE
 LAVATORY- SECTION 603.2.3 FBC ACC.
  
 7) 1.0A: SHOW THE MANEUVERING CLEARANCES AT THE
 RESTROOM DOORS- REFER TO FIGURES 404.2.1 FBC ACC.
 PROVIDE DIMENSIONS ON THE PLAN TO VERIFY COMPLIANCE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2020-10-06 Cont ID  
Sent By ccole Date 2020-10-06 Time 10:01 Rev Time 0.00
Received By ccole Date 2020-10-06 Time 10:01 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2020-09-22 Cont ID  
Sent By jwitmer Date 2020-09-22 Time 08:32 Rev Time 0.00
Received By jwitmer Date 2020-09-22 Time 08:03 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-09-11 Cont ID  
Sent By jleahy Date 2020-09-11 Time 14:16 Rev Time 0.00
Received By jleahy Date 2020-09-11 Time 14:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-08-18 Cont ID  
Sent By medwards Date 2020-08-18 Time 08:22 Rev Time 0.00
Received By medwards Date 2020-08-18 Time 08:22 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-07-15 Cont ID  
Sent By medwards Date 2020-07-15 Time 08:12 Rev Time 0.00
Received By medwards Date 2020-07-15 Time 08:09 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy