| Plan Review Stops For Permit 20061111 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-08-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-08-21 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-08-21 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-28 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-28 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2020-07-28 14:27:19 | PLAN REVIEW GENERATOR - BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) PROVIDE WIND DESIGN LOADS FOR THE GENERATOR PER FBC | | | 107.3.5.3 AND R301.2 AS REQUIRED FOR THE GENERATOR PAD | | | ENGINEERING. | | | 2) STRUCTURAL DETAIL OF PAD AND DESIGN LOADS SHALL BE | | | SIGNED AND SEALED BY A DESIGN PROFESSIONAL. | | | 3) PROVIDE STRUCTURAL DETAIL OF GENERATOR PAD. | | | 4) PROVIDE A SITE PLAN. SHOW LOCATION OF PROPOSED | | | GENERATOR. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-08-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-26 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-26 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-28 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-28 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2020-07-28 14:35:18 | PLAN REVIEW GENERATOR - ELECTRICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) PROVIDE SPECIFICATIONS FOR AUTOMATIC TRANSFER | | | SWITCH. ? ATS | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2) PROVIDE ELCTRICAL RISER DIAGRAHM. | | | PROVIDE RISER DIAGRAM OF EXISTING SERVICE. INCLUDE | | | ADDITION OF GENERATOR AND ATS. NEC 215.5; WPB FBC | | | 107.2.1 | | | | | | 2) ELECTRICAL RISER | | | PROVIDE CONDUCTOR SIZE AND TYPE OF CONTROL CIRCUIT | | | WIRING. 215.5; WPB FBC 107.2.1 | | | | | | 3) PROVIDE NEW LOAD CALCULATIONS. | | | PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE EXISTING | | | AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE IS | | | ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2020-08-26 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-08-26 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-08-26 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2020-08-26 09:46:33 | 08/26/20 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | | | 2020-08-26 08:57:15 | PLAN REVIEW GENERATOR FUEL GAS | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED. SEE | | | BELOW. | | | | | | 1) GAS ISOMETRIC DRAWING: PROVIDE DETAIL OF GAS PIPING | | | AT GENERATOR. INCLUDE SHUTOFF, DRIP LEG AND REGULATOR. | | | | | | 1A) PROVIDE DELIVERY PRESSURE TO THE GENERATOR FROM THE | | | OUTLET OF THE REGULATOR- SECTION G2421.1 | | | | | | 2) SUBMIT SPECS FOR THE REGULATOR AT THE GENERATOR WITH | | | MARKUPS TO INDICATE WHICH MODEL TO BE INSTALLED, INLET | | | AND OUTLET PRESSURES, AND ORIFICE SIZE- SECTION | | | G2421.1. | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-28 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-28 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2020-07-28 14:33:08 | PLAN REVIEW GENERATOR FUEL GAS | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) GAS ISOMETRIC DRAWING: PROVIDE DETAIL OF GAS PIPING | | | AT GENERATOR. INCLUDE SHUTOFF, DRIP LEG AND REGULATOR. | | | | | | 1A) PROVIDE DELIVERY PRESSURE TO THE GENERATOR FROM THE | | | OUTLET OF THE REGULATOR- SECTION G2421.1 | | | | | | 2) SUBMIT SPECS FOR THE REGULATOR AT THE GENERATOR WITH | | | MARKUPS TO INDICATE WHICH MODEL TO BE INSTALLED, INLET | | | AND OUTLET PRESSURES, AND ORIFICE SIZE- SECTION | | | G2421.1. | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-08-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-26 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-17 |
Time |
13:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-08-13 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-08-13 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-07-13 |
Time |
16:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2020-08-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-26 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-26 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-28 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-28 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-08-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-26 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-26 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-28 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-28 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2020-07-28 14:28:02 | PLAN REVIEW GENERATOR - DIGITAL SIGNATURES AND SEALS | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON | | | ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15 | | | | | | 2) DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 3) UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | | | | 4) FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | | | NOTE: YOU MAY PROVIDE A PAPER PLAN WITH WET SIGNATURE | | | AND SEAL PRIOR TO PERMIT. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-08-13 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-08-13 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2020-08-13 |
Time |
08:20 |
Sent To |
I |
|
| Notes |
|
|