| Plan Review Stops For Permit 20061052 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2020-10-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-10-16 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-10-16 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2020-10-16 12:43:02 | ADDRESS CHANGED FROM 3200 TO 2820 ELECTROMICS WAY, | | | WHICH IS IN LINE WITH THE NEW BUILDINGS MAIN ADDRESS. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2020-06-24 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-06-24 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-06-24 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2020-06-24 10:19:41 | PLEASE INDICATE WHICH DOOR IS THE MAIN ENTRANCE TO THE | | | PROPERTY. DO YOU WISH TO HAVE A SEPARATE ADDRESS FOR | | | THE WAREHOUSE? PLEASE EMAIL [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-10-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-10-07 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-10-07 13:35:27 | SAMANTHA HILL HELPED ME UPLOAD THE NEW 53 PAGE NUCOR | | | TESTING FILE WITH AISI S-100 TESTING DOCUMENTS. | | | JIM WITMER BUILDING PLAN REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2020-09-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-09-29 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-09-29 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2020-09-29 17:15:02 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20061052 | | | ADD: 3200 ELECTRONICS WAY | | | CONT: CLEAR SPAN STRUCTURES | | | TEL: 561-803-8100 / GLENN BLOUNT | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 3RD REVIEW | | | DATE: TUES. SEPT. 29TH/ 2020 | | | ACTION: | | | | | | 1-4) COMPLIED. | | | . | | | 4) 2ND REQUEST. THIS REVIEW THE NUCOR DRAWINGS PACKAGE | | | OF 14 AND ONE OF 36 PLUS THE PRODUCT APPROVALS FOR THE | | | ROOF AND WALL SYSTEMS. ROOF ZONE 3 IS 6 FEET 9 INCHES | | | IN THE DIRECTION OF THE RIDGE. | | | IN THE PACKAGE OF 36 PLANS PLAN 15 OF 36 IS THE ROOF | | | PLAN WITH ROOF ZONES. SHEET 9 OF 14 SET OF PLANS SHOWS | | | THE ROOF PURLIN SPACING. THE SPACING STARTS FROM THE | | | EDGE OF THE ROOF WITH 2 FEET TO THE NEXT PURLIN THEN A | | | SPACE OF 3 FEET 9 INCHES AND A SECOND SPACE OF 3 FEET | | | NINE INCHES. | | | | | | THE ROOFING PRODUCT APPROVAL FL. 4891.1-R8 PAGE 2 OF 3 | | | INDICATES THE ROOFING SYSTEMS (3) WITH VICE LOCK 360 | | | WITH SUPPORTS AT 24 INCHES ON CENTER IS GOOD FOR 108.8 | | | PSF. THE SAME VISE LOCK 360 WITH SUPPORTS AT 5FEET IS | | | GOOD FOR 59.3PSF. IT WOULD APPEAR ANOTHER PURLIN IS | | | NEEDED IN THE CORNER OF THE BUILDING FOR ROOF ZONE 3. | | | THE SAME SITUATION MAY OCCUR IN WALL ZONE 5 THE WALL | | | END ZONE. SHEET 11OF 36, SHEET 9 OF 14 AND PRESSURES | | | FOR THE END ZONE DO NOT MAKE IT. PLEASE ALSO NOTE THE | | | SHOP DRAWING STAMP OF APPROVAL BLOCKS OUT THE BOTTOM | | | SPAN ON ALL SHEETS RIGHT SIDE OF THE BUILDING, ASSUMING | | | THE LEFT SIDE WILL HAVE THE SAME SPACING. | | | CALLED NUCOR ABOUT THIS ISSUE, SPOKE TO RUSS MILFORD | | | PROJECT MANAGER HE SAID THE ENGINEER ANDREW JOHNSON | | | WOULD GET BACK TO ME. | | | | | | 5) BUILDING PROVISO: BUILDINGS WITH WELDED OR BOLTED | | | CONNECTIONS, THE CONTRACTOR IS REQUIRED TO PROVIDE WELD | | | PROCEDURE SPECIFICATIONS & WELDER OPERATOR PERFORMANCE | | | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED | | | STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON | | | THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL | | | BE REQUIRED. | | | 2017 FBC-B 2204.1 WELDING | | | 1. WELD PROCEDURES SPECIFICATIONS | | | 2. QUALIFICATIONS OF WELDING PERSONAL | | | 2017 FBC-B 2204.2 BOLTING. | | | IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED, | | | PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD | | | AT | | | 561-805-6666. | | | | | | BUILDING PROVISO:6) DELEGATED ENGINEERING. 61G15-30.003 | | | ENGINEERING DOCUMENT CLASSIFICATION. FL 61G-15-30.006 | | | (3) THE DELEGATED ENGINEER SHALL FORWARD THE DELEGATED | | | ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR | | | REVIEW. | | | | | | | | | 7-9) COMPLIED. | | | | | | 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-08-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-08-31 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-08-31 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2020-08-31 17:20:48 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20061052 | | | ADD: 3200 ELECTRONICS WAY | | | CONT: CLEAR SPAN STRUCTURES | | | TEL: 561-803-8100 / GLENN BLOUNT | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2ND REVIEW | | | DATE: MON. AUGUST 31ST/ 2020 | | | ACTION: DENIED | | | | | | NOTICE!!!!!!!! 4X FEE / NOTICE!!!!! FLORIDA STATUTE | | | 553.80(2)(B) | | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | | | | 1) SEMI-COMPLIED, 2ND REQUEST. THE RESPONSE LETTER | | | STATES THE PERMITTED USE OF THE SITE PLAN APPROVAL AS | | | INDUSTRIAL. I BELIEVE THAT YOU ARE INDICATING THE SITE | | | PLAN APPROVAL PROCESS KNOWN AS PPRC. THIS IS A ZONING | | | REQUIREMENT. I AM NOT REVIEWING FOR ZONING REGULATIONS | | | BUT UNDER THE 2017 FLORIDA BUILDING CODE FOR THE | | | STRUCTURE AND FUTURE USE ONCE THE BUILDING HAS ITS | | | CERTIFICATE OF OCCUPANCY. TO MEET BOTH CODES YOU WILL | | | NEED TO IDENTIFY UNDER WHICH CODE YOU ARE DESCRIBING | | | THE BUILDING. IT IS COMMON FOR DAYCARE OCCUPANCIES TO | | | HAVE THE DOUBLE COMMON, ONE FOR THE STATE REQUIREMENTS | | | AND ONE FOR THE THE REQUIREMENTS FOUND IN THE BUILDING | | | CODE. I WOULD SUGGEST THIS IS A WAY TO SATISFY BOTH THE | | | ZONING REQUIREMENTS AS WELL AS THE 2017 FBC-BUILDING | | | REQUIREMENTS. | | | 1ST REVIEW. THERE IS A DISCREPANCY IN OCCUPANCY | | | CLASSIFICATION FOR THIS BUILDING. THE SITE PLAN SHEET | | | LIST THE OCCUPANCIES AS INDUSTRIAL & BUSINESS WHEREAS | | | THE LIFE SAFETY SHEET INDICATES THE OCCUPANCIES TO BE | | | S2 STORAGE AND BUSINESS OCCUPANCY. 107.2.1.2. | | | ADDITIONAL INFORMATION IS REQUIRED, DISCREPANCY IN | | | PLANS. | | | | | | 2) COMPLIED, NOT IN AN A FLOOD ZONE. | | | 3) COMPLIED | | | . | | | 4) 2ND REQUEST. SHEET S-4.0 SHOWS ONLY THE BLOCK | | | EXTERIOR WALL. THERE ARE NO STRUCTURAL SHEETS SUBMITTED | | | FOR THE METAL FRAME BUILDING, SHOWING THE BUILDING | | | ELEVATIONS WITH THE SPACING OF THE HORIZONTAL GIRTS AND | | | PURLINS. COMPLIANCE WITH THE EXTERIOR WALL AND ROOF | | | FASTENING SYSTEM CANNOT BE REVIEWED. THE MISSING | | | INFORMATION THE PRODUCT APPROVAL FOR THE METAL EXTERIOR | | | WALL SYSTEM AND METAL ROOF SYSTEM. WITHOUT THE PRODUCT | | | APPROVALS BEING SUBMITTED, IDENTIFYING THE TYPE OF WALL | | | AND ROOF PANELS BEING INSTALLED, WITH THEIR ALLOWABLE | | | SPACING BETWEEN SUPPORTS (GIRTS & PURLINS) AND | | | ASSOCIATED PRESSURES NO REVIEW FOR THE STRUCTURAL | | | PORTION OF THE BUILDING CAN BE COMPLETED. | | | | | | 5) COMPLIED. BUILDINGS WITH WELDED OR BOLTED | | | CONNECTIONS, THE CONTRACTOR IS REQUIRED TO PROVIDE WELD | | | PROCEDURE SPECIFICATIONS & WELDER OPERATOR PERFORMANCE | | | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED | | | STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON | | | THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL | | | BE REQUIRED. | | | 2017 FBC-B 2204.1 WELDING | | | 1. WELD PROCEDURES SPECIFICATIONS | | | 2. QUALIFICATIONS OF WELDING PERSONAL | | | 2017 FBC-B 2204.2 BOLTING. | | | IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED | | | PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD | | | AT | | | 561-805-6666. | | | | | | 6A)2ND REQUEST. THE 2ND REVIEW CYCLE NO WALL NOR | | | ROOFING PRODUCT APPROVALS WERE SUBMITTED!!!!!!!! | | | COMPONENTS & CLADDING PLEASE SUPPLY THE PRODUCT | | | APPROVAL FULL REPORTS. IF IN THE PRODUCT APPROVAL THERE | | | ARE MULTIPLE SUB-SYSTEMS APPROVED IDENTIFY (CIRCLE) | | | WHICH APPLICATION IS TO BE INSTALLED. | | | 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES. | | | (B) WINDOWS & MULLIONS | | | (C) PANEL WALLS: METAL WALL PANELS, STOREFRONTS, | | | CURTAIN WALLS, WALL LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, METAL ROOF PANELS, | | | LIGHTWEIGHT CONCRETE INSULATION, ROOF TOP VENTILATORS | | | | | | 6B) 2ND REQUEST. W. P. B. 107.3.4. PRODUCT APPROVALS. | | | THOSE PRODUCTS WHICH ARE REGULATED BY FLORIDA | | | ADMINISTRATIVE CODE RULE 61G20 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 6C) 2ND REQUEST. DELEGATED ENGINEERING. 61G15-30.003 | | | ENGINEERING DOCUMENT CLASSIFICATION. FL 61G-15-30.006 | | | (3) THE DELEGATED ENGINEER SHALL FORWARD THE DELEGATED | | | ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR | | | REVIEW. | | | | | | 7) 2ND REQUEST. THE OTHER UNKNOWN IS IF THE ENGINEER OF | | | RECORD FOR THE METAL BUILDING MANUFACTURER HAS DESIGNED | | | THE ROOF SYSTEM TO SECTION 2211.5 OF THE FBC-B AISI | | | S210 OR AISI S 100? WITH A GREATER DEDUCTION IN | | | PRESSURES ALONG WITH THE DEDUCTION FROM VULT TO VASD? | | | | | | 8) ADA DETAILS SHEET ADA 1.1: | | | | | | 8-9) COMPLIED. | | | | | | 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED | | | DOCUMENTATION (PRODUCT APPROVALS). WITH THE NEXT PLAN | | | REVIEW CYCLE THERE MAYBE ADDITIONAL REVIEW COMMENTS | | | BECAUSE OF NEW PLANS AND INFORMATION LACKING UNDER THE | | | PRIOR REVIEW. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-07-12 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-07-12 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2020-07-12 15:27:47 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20061052 | | | ADD: 3200 ELECTRONICS WAY | | | CONT: CLEAR SPAN STRUCTURES | | | TEL: 561-803-8100 / GLENN BLOUNT | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 1ST REVIEW | | | DATE: SUN. JULY 12TH/ 2020 | | | ACTION: DENIED | | | | | | 1) THERE IS A DISCREPANCY IN OCCUPANCY CLASSIFICATION | | | FOR THIS BUILDING. THE SITE PLAN SHEET LIST THE | | | OCCUPANCIES AS INDUSTRIAL & BUSINESS WHEREAS THE LIFE | | | SAFETY SHEET INDICATES THE OCCUPANCIES TO BE S2 STORAGE | | | AND BUSINESS OCCUPANCY. 107.2.1.2. ADDITIONAL | | | INFORMATION IS REQUIRED, DISCREPANCY IN PLANS. | | | | | | 2) PLEASE PROVIDE A SURVEY, THERE SEEMS TO BE A PORTION | | | OF THE PROPERTY IN AN A FLOOD ZONE. THE OTHER ISSUE IS | | | THE LOCATION OF THE BUILDING AND CLOSENESS TO THE | | | PROPERTY LINE AND COMPLIANCE WITH TABLE 602 OF THE 2017 | | | FBC-B. SHOW DISTANCES FROM PROPERTY LINES AND OTHER | | | STRUCTURES AND OR PROPOSED STRUCTURES. | | | | | | 3) THERE IS ALSO A DISCREPANCY IN THE TYPE OF MATERIAL | | | THE REAR WALL IS TO BE CONSTRUCTED FROM. SHEET A-4.0 | | | HAS A NOTE BY THE BACK WALL DETAIL STATING THAT THE | | | BACK WALL IS TO BE METAL SIDING BY THE BUILDING | | | MANUFACTURER, TYPICAL. WHEREAS SHEET S-3.0 & S-4.0 | | | DETAILS A & B BOTH SHOW THE REAR WALL TO BE CONSTRUCTED | | | AS A 12 INCH THICK CMU WALL AND COLUMN TYPE 2 ALSO | | | BEING 12 INCHES THICK. | | | | | | 4) THERE ARE NO STRUCTURAL SHEETS SUBMITTED FOR THE | | | METAL FRAME BUILDING, SHOWING THE BUILDING ELEVATIONS | | | WITH THE SPACING OF THE HORIZONTAL GIRTS AND PURLINS. | | | COMPLIANCE WITH THE EXTERIOR WALL AND ROOF FASTENING | | | SYSTEM CANNOT BE REVIEWED. THE MISSING INFORMATION THE | | | PRODUCT APPROVAL FOR THE METAL EXTERIOR WALL SYSTEM AND | | | METAL ROOF SYSTEM. WITHOUT THE PRODUCT APPROVALS BEING | | | SUBMITTED, IDENTIFYING THE TYPE OF WALL AND ROOF PANELS | | | BEING INSTALLED, WITH THEIR ALLOWABLE SPACING BETWEEN | | | SUPPORTS (GIRTS & PURLINS) AND ASSOCIATED PRESSURES NO | | | REVIEW FOR THE STRUCTURAL PORTION OF THE BUILDING CAN | | | BE COMPLETED. | | | | | | 5) BUILDINGS WITH WELDED OR BOLTED CONNECTIONS, THE | | | CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE | | | SPECIFICATIONS & WELDER OPERATOR PERFORMANCE | | | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED | | | STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON | | | THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL | | | BE REQUIRED. | | | 2017 FBC-B 2204.1 WELDING | | | 1. WELD PROCEDURES SPECIFICATIONS | | | 2. QUALIFICATIONS OF WELDING PERSONAL | | | 2017 FBC-B 2204.2 BOLTING. | | | IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED | | | PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD | | | AT | | | 561-805-6666. | | | | | | 6A) COMPONENTS & CLADDING PLEASE SUPPLY THE PRODUCT | | | APPROVAL FULL REPORTS. IF IN THE PRODUCT APPROVAL THERE | | | ARE MULTIPLE SUB-SYSTEMS APPROVED IDENTIFY (CIRCLE) | | | WHICH APPLICATION IS TO BE INSTALLED. | | | 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES. | | | (B) WINDOWS & MULLIONS | | | (C) PANEL WALLS: METAL WALL PANELS, STOREFRONTS, | | | CURTAIN WALLS, WALL LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, METAL ROOF PANELS, | | | LIGHTWEIGHT CONCRETE INSULATION, ROOF TOP VENTILATORS | | | | | | 6B) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE | | | 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 6C) DELEGATED ENGINEERING. 61G15-30.003 ENGINEERING | | | DOCUMENT CLASSIFICATION. FL 61G-15-30.006 (3) THE | | | DELEGATED ENGINEER SHALL FORWARD THE DELEGATED | | | ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR | | | REVIEW. | | | | | | 7) THE OTHER UNKNOWN IS IF THE ENGINEER OF RECORD FOR | | | THE METAL BUILDING MANUFACTURER HAS DESIGNED THE ROOF | | | SYSTEM TO SECTION 2211.5 OF THE FBC-B AISI S210 OR AISI | | | S 100? WITH A GREATER DEDUCTION IN PRESSURES ALONG WITH | | | THE DEDUCTION FROM VULT TO VASD? | | | | | | 8) ADA DETAILS SHEET ADA 1.1: | | | | | | 8A) DETAIL 12 WATER CLOSET DETAIL DOES NOT PROVIDE THE | | | HEIGHT OF THE GRAB BARS FROM FINISH FLOOR. 2017 | | | FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB | | | BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL | | | POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE | | | THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING | | | SURFACE, NOT CENTERLINE. | | | | | | 8B) DETAIL # 13 THE DRINKING FOUNTAIN SHOWS THE HIGH/ | | | LOW DRINKING FOUNTAIN. THE BOTTOM OF THE LOWER DRINKING | | | FOUNTAIN DOES MEET THE CODE REQUIREMENT OF NOT HIGHER | | | THAN THE 27 INCHES WHEREAS THE HIGH FOUNTAIN IS WELL | | | ABOVE THE REQUIRED 27 INCHES FROM FINISH FLOOR. | | | 2017 FBC-ACCESSIBILITY CODE SECTION, PROTRUDING OBJECTS | | | 307.2 PROTRUSION LIMITS 307.2. OBJECTS WITH LEADING | | | EDGES MORE THAN 27 INCHES AND NOT MORE THAN 80 INCHES | | | ABOVE THE FLOOR SHALL NOT PROTRUDE MORE THAN 4 INCHES | | | HORIZONTALLY IN TO THE CIRCULATION PATH. | | | | | | 9) 2017 ENERGY CODE SECTION C401.2 APPLICATION. | | | COMMERCIAL BUILDINGS SHALL COMPLY WITH ONE OF THE | | | FOLLOWING: | | | 3.1.THE REQUIREMENTS OF ANSI/ASHRAE/IESNA 90.1, | | | EXCLUDING SECTION 9.4.1.1(G) OF THE STANDARD. | | | 3.2.THE REQUIREMENTS OF SECTIONS C402 THROUGH C405. IN | | | ADDITION, COMMERCIAL BUILDINGS SHALL COMPLY WITH | | | SECTION C406 AND TENANT SPACES SHALL COMPLY WITH | | | SECTION C406.1.1. | | | 3.3.THE REQUIREMENTS OF SECTIONS C402.5, C403.2, C404, | | | C405.2, C405.3, C405.5, C405.6 AND C407. THE BUILDING | | | ENERGY COST SHALL BE EQUAL TO OR LESS THAN 85 PERCENT | | | OF THE STANDARD REFERENCE DESIGN BUILDING. | | | | | | 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED | | | DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE | | | MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS | | | AND INFORMATION LACKING UNDER THE PRIOR REVIEW. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-09-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-09-03 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-03 |
Time |
13:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-07-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-31 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-30 |
Time |
17:29 |
Sent To |
|
|
| Notes |
| 2020-07-31 08:06:01 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGE E.2 | | | | | | 1) SERVICE SHOWS MAIN BREAKER PANEL CONDUCTORS FROM | | | METER TO PANEL HAVE TO ROUTED OUTSIDE OF THE BUILDING | | | IF MORE THAN 8' OF CO NDUCTOR IS TO BE USED. | | | | | | 2) CIRCUIT A-29 TO BE GFCI PROTECTED TO DRINKING | | | FOUNTAIN. 422.52 | | | | | | 3) BREAK ROOM OUTLETS WITHIN 6' OF THE SINK TO BE GFCI | | | PROTECTED 210.8(B) | | | | | | PAGE E.4 | | | | | | 1) LOAD CALCULATION LIGHTING LOAD NOT PER 220.12 SEE | | | TABLE 220,12 | | | | | | 2) AIC RATING OF MAIN AND PANEL REQUIRED PER 110.9, | | | 110,10 AND LABELED PER 110.24 | | | PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | | | | 3) PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. NEC 250.94 | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-08-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2020-08-19 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-08-19 17:46:52 | REVIEWED UNDER FORMAL ENGINEERING SUBMITTAL E20040030. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2020-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-07-24 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-07-24 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2020-07-24 12:59:01 | CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT | | | APPLICATION IF REQUIRED | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | | | | ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE | | | | | | MAIN PHONE: (561) 822-1200 | | | | | | IF YOU HAVE AN ISSUED ENGINEERING PERMIT, OR A PENDING | | | APPLICATION, PLEASE ADVISE VIA EMAIL ([email protected]) | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-08-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-08-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-08-14 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2020-06-25 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-06-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-06-25 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2020-06-25 11:47:35 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SHEET LS 1.0 - THERE IS AN INDICATION OF A WAREHOUSE | | | AND RACK STORAGE. | | | | | | PLEASE PROVIDE DETAILS OF WHAT THE WILL BE TAKING PALCE | | | IN THE WAREHOUSE, I.E. MANUFACTURING, AND WHAT WILL BE | | | STORED, HOW WILL IT STORED (PALLET TYPE, SHELVING TYPE, | | | WRAPPING OF PRODUCT, ETC) | | | | | | | | | | | | 1A) SHEET LS 1.0 - THERE IS AN INDICATION OF A MIXED | | | NONSPEARATED OCCUPANCY; BUSINESS/STORAGE | | | THOUGH THERE A SEPARATION OF THE OCCUPANCY THERE DOES | | | NOT APPEAR TO BE A SEPARATION OF THE HAZARD. | | | | | | PER NFPA 101 CH 6 OCCUPANCY CLASSIFICATION. | | | | | | 6.2 HAZARD OF CONTENTS. | | | 6.2.1 GENERAL. | | | 6.2.1.1 FOR THE PURPOSE OF THIS CODE, THE HAZARD OF | | | CONTENTS SHALL | | | BE THE RELATIVE DANGER OF THE START AND SPREAD OF FIRE, | | | THE DANGER OF | | | SMOKE OR GASES GENERATED, AND THE DANGER OF EXPLOSION | | | OR OTHER | | | OCCURRENCE POTENTIALLY ENDANGERING THE LIVES AND SAFETY | | | OF THE | | | OCCUPANTS OF THE BUILDING OR STRUCTURE. | | | 6.2.1.2 HAZARD OF CONTENTS SHALL BE CLASSIFIED BY THE | | | REGISTERED | | | DESIGN PROFESSIONAL (RDP) OR OWNER AND SUBMITTED TO THE | | | AUTHORITY HAVING JURISDICTION FOR REVIEW AND APPROVAL | | | ON THE BASIS | | | OF THE CHARACTER OF THE CONTENTS AND THE PROCESSES OR | | | OPERATIONS | | | CONDUCTED IN THE BUILDING OR STRUCTURE. | | | 6.2.1.3* FOR THE PURPOSE OF THIS CODE, WHERE DIFFERENT | | | DEGREES OF | | | HAZARD OF CONTENTS EXIST IN DIFFERENT PARTS OF A | | | BUILDING OR STRUCTURE, | | | THE MOST HAZARDOUS SHALL GOVERN THE CLASSIFICATION, | | | UNLESS | | | HAZARDOUS AREAS ARE SEPARATED OR PROTECTED AS SPECIFIED | | | IN SECTION | | | 8.7 AND THE APPLICABLE SECTIONS OF CHAPTERS 11 THROUGH | | | 43. | | | 6.2.2 CLASSIFICATION OF HAZARD OF CONTENTS. | | | 6.2.2.1* GENERAL. THE HAZARD OF CONTENTS OF ANY | | | BUILDING OR | | | STRUCTURE SHALL BE CLASSIFIED AS LOW, ORDINARY, OR HIGH | | | IN | | | ACCORDANCE WITH 6.2.2.2, 6.2.2.3, AND 6.2.2.4. | | | 6.2.2.2* LOW HAZARD CONTENTS. LOW HAZARD CONTENTS SHALL | | | BE | | | CLASSIFIED AS THOSE OF SUCH LOW COMBUSTIBILITY THAT NO | | | SELFPROPAGATING | | | FIRE THEREIN CAN OCCUR. | | | 6.2.2.3* ORDINARY HAZARD CONTENTS. ORDINARY HAZARD | | | CONTENTS SHALL | | | BE CLASSIFIED AS THOSE THAT ARE LIKELY TO BURN WITH | | | MODERATE RAPIDITY OR | | | TO GIVE OFF A CONSIDERABLE VOLUME OF SMOKE. | | | 6.2.2.4* HIGH HAZARD CONTENTS. HIGH HAZARD CONTENTS | | | SHALL BE | | | CLASSIFIED AS THOSE THAT ARE LIKELY TO BURN WITH | | | EXTREME RAPIDITY OR FROM | | | WHICH EXPLOSIONS ARE LIKELY. (FOR MEANS OF EGRESS | | | REQUIREMENTS, SEE | | | SECTION 7. 11.) | | | | | | PLEASE NOTE THE APPENDIX NARRATIVE FOR HAZARD | | | CLASSIFICATION: | | | | | | A.6.2.2.2 CHAPTER 42 RECOGNIZES STORAGE OF | | | NONCOMBUSTIBLE | | | MATERIALS AS LOW HAZARD. IN OTHER OCCUPANCIES, IT IS | | | ASSUMED | | | THAT, EVEN WHERE THE ACTUAL CONTENTS HAZARD IS NORMALLY | | | LOW, | | | THERE IS SUFFICIENT LIKELIHOOD THAT SOME COMBUSTIBLE | | | MATERIALS | | | OR HAZARDOUS OPERATIONS WILL BE INTRODUCED IN | | | CONNECTION | | | WITH BUILDING REPAIR OR MAINTENANCE, OR SOME | | | PSYCHOLOGICAL | | | FACTOR MIGHT CREATE CONDITIONS CONDUCIVE TO PANIC, SO | | | THAT THE | | | EGRESS FACILITIES CANNOT SAFELY BE REDUCED BELOW THOSE | | | SPECIFIED | | | FOR ORDINARY HAZARD CONTENTS. | | | A.6.2.2.3 ORDINARY HAZARD CLASSIFICATION REPRESENTS THE | | | CONDITIONS | | | FOUND IN MOST BUILDINGS AND IS THE BASIS FOR THE | | | GENERAL | | | REQUIREMENTS OF THIS CODE. | | | THE FEAR OF POISONOUS FUMES OR EXPLOSIONS IS | | | NECESSARILY A | | | RELATIVE MATTER TO BE DETERMINED ON A JUDGMENT BASIS. | | | ALL | | | SMOKE CONTAINS SOME TOXIC FIRE GASES BUT, UNDER | | | CONDITIONS OF | | | ORDINARY HAZARD, THERE SHOULD BE NO UNDULY DANGEROUS | | | EXPOSURE | | | DURING THE PERIOD NECESSARY TO ESCAPE FROM THE FIRE | | | AREA, | | | ASSUMING THERE ARE PROPER EXITS. | | | | | | SO THE HAZARD OF THE WAREHOUSE(ORDINARY) AND | | | BUSINESS(LOW) SEPARATION IS REQUIRED. | | | | | | PLEASE PROVIDE THE REQUIRED RATED SEPARATION OF THE TWO | | | HAZARDS. | | | | | | | | | | | | 2) SHEET LS 1.0 - THERE IS ONLY 1 EXIT INDICATED FROM | | | THE WAREHOUSE AREA. TWO ARE REQUIRED. | | | | | | PER NFPA 101 | | | | | | 42.2.4 NUMBER OF MEANS OF EGRESS. THE NUMBER OF MEANS | | | OF | | | EGRESS SHALL COMPLY WITH 42.2.4.1 THROUGH 42.2.4.3. | | | (SEE ALSO | | | SECTION 7.4.) | | | 42.2.4.1 THE NUMBER OF MEANS OF EGRESS SHALL COMPLY | | | WITH ANY OF | | | THE FOLLOWING: | | | (1) IN LOW HAZARD STORAGE OCCUPANCIES, A SINGLE MEANS | | | OF EGRESS | | | SHALL BE PERMITTED FROM ANY STORY OR SECTION. | | | (2) IN ORDINARY HAZARD STORAGE OCCUPANCIES, A SINGLE | | | MEANS OF | | | EGRESS SHALL BE PERMITTED FROM ANY STORY OR SECTION, | | | PROVIDED | | | THAT THE EXIT CAN BE REACHED WITHIN THE DISTANCE | | | PERMITTED AS A | | | COMMON PATH OF TRAVEL. | | | (3) ALL BUILDINGS OR STRUCTURES NOT COMPLYING WITH | | | 42.2.4.1(1) OR | | | 42.2.4.1(2) AND USED FOR STORAGE, AND EVERY SECTION | | | THEREOF | | | CONSIDERED SEPARATELY, SHALL HAVE NOT LESS THAN TWO | | | SEPARATE | | | MEANS OF EGRESS AS REMOTELY LOCATED FROM EACH OTHER AS | | | PRACTICABLE. | | | | | | THE TABLE INDICATES 50FT FOR AN UNSPRINKLERED BUILDING, | | | THE PLAN INDICATES 75FT. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | | | | | | | 3) SHEET LS 1.0 - RACKS ARE INDICATED AND SHALL BE | | | SUBMITTED AND INSTALLED UNDER SEPARATE PERMIT AND SHOP | | | DRAWINGS INCLUDING MANUFACTURE SPEC SHEETS. | | | | | | PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT | | | | | | | | | | | | 4) SHEET LS 1.0 & SP 1 - | | | | | | | | | | | | | | | SHEET A 1.1 - WITHIN THE DOOR SCHEDULE THERE ARE | | | INDICATIONS OF HARDWARE SETS; HOWEVER, I COULD NOT FIND | | | THE DETAILS OF THE HARDWARE SETS TO CONFIRM COMPLIANCE | | | WITH NFPA 101 7.2.1 AS INDICATED ON THE NOTE. | | | | | | PLEASE PROVIDE HARDWARE SET DETAILS. | | | | | | | | | | | | 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-10-16 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-10-16 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-09-22 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-09-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-09-15 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-08-13 |
Time |
08:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-07-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-31 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-06-23 |
Time |
15:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-08-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-08-24 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-08-20 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2020-08-24 13:20:14 | MU-2020-32119 - $6674.01 - PAID | | 2020-08-20 09:22:27 | 8/20/20 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-07-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-07-12 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2020-07-12 15:31:18 | IMPACT FEES - DIGITAL SUBMITTALS: | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-08-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-08-28 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-08-28 |
Time |
10:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-07-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-07-23 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-23 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2020-07-23 09:35:26 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20061052 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE VENTILATION CALCULATIONS FOR EACH USE | | | OF SPACE IN THIS BUILDING I.E.- VENTILATION | | | CALCULATIONS FOR THE STORAGE AREA. FBC M 403, FBC M 402 | | | | | | 2) PLEASE PROVIDE A LIST OF MATERIALS BEING STORED IN | | | THE WAREHOUSE. FBC FS 107.2.1 | | | | | | 3) PLEASE PROVIDE A STORAGE LAYOUT SHEET WITH THE RACKS | | | LOCATIONS ALONG WITH THE HEIGHT OF THE RACKS. FBC B | | | 910.2.2 | | | | | | 4) SHEET MOB OF 5: AIR CONDITIONING EQUIPMENT SCHEDULE- | | | REMARKS HAS A MOTE 15 LISTED. THERE IS NO NOTE 15 IN | | | THE NOTES SECTION. | | | | | | 5) PLEASE SHOW THAT THE CONDENSER LOCATION IS PROTECTED | | | FROM TRAFFIC. FBC M 303.4 | | | | | | 6) PLEASE SHOW CONDENSATION PIPING AND TERMINATION | | | LOCATION FOR THE FCU-1. FBC M 307.2.1 | | | | | | 7) PLEASE LABEL EACH RETURN GRILL WITH THE CFM?S. FBC | | | FS 107.2.1 | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-08-27 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-08-27 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-08-27 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2020-08-27 12:52:20 | 08/27/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2020-07-29 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-07-29 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-07-29 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2020-07-29 11:56:48 | 07/29/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEW | | | AVAILABLE FROM 6:30 AM TO 7:30 AM / 2:00 PM TO 5:00 PM | | | EMAIL: [email protected] CELL: 561-701-6437 | | | |
|
|
| Review Stop |
P-IRRIGATE |
IRRIGATION REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-07-29 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-07-29 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-07-29 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2020-07-29 11:56:03 | IRRIGATION PLAN REVIEW, A IRRIGATION PLAN HAS NOT BEEN | | | INCLUDED IN THIS SUBMITTAL PACKAGE. A IRRIGATION PLAN | | | REVIEW HAS NOT BEEN PERFORMED AT THIS TIME. A SEPARATE | | | IRRIGATION PERMIT AND PLANS WILL BE REQUIRED FOR A | | | CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE | | | COMPLETE PLANS AND IRRIGATION THAT REFLECTS THE ENTIRE | | | SCOPE OF IRRIGATION WORK TO BE DONE PER THE WPB | | | AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | PLANS ARE REQUIRED TO BE DESIGNED AND SIGNED AND SEALED | | | BY A LICENSED ENGINEER OR ARCHITECT. PLANS FURNISHED BY | | | AN INTERIOR DESIGNER ARE NOT ACCEPTABLE. PROVIDE | | | CORRECTION. FS 471.003(2)(H); 471.025; FBC 107.2.1, | | | 107.3.5 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2020-10-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-10-07 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-10-07 13:35:48 | SAMANTHA HILL HELPED ME UPLOAD THE NEW 53 PAGE NUCOR | | | TESTING FILE WITH AISI S-100 TESTING DOCUMENTS. | | | JIM WITMER BUILDING PLAN REVIEW. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2020-09-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-09-29 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-09-29 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2020-09-29 17:16:02 | SEE BUILDING REVIEW NOTE 4. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2020-08-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-08-31 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-08-31 17:24:36 | ROOF REVIEW: 2ND REVIEW, NO PLANS SHOWING THE SPACING | | | OF THE PURLINS IN THE ROOF ZONES 1,2,NOR 3 AND THIS | | | REVIEW (2ND) NO ROOFING PRODUCT APPROVAL IDENTIFYING | | | THE ROOFING MATERIAL, WIDTH OF PANEL, TYPE, GAUGE METAL | | | ALLOWABLE SPANS AND TYPE OF ROOF ANCHORS!!!!!!!!SEE | | | BUILDING COMMENTS. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-07-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-07-12 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-07-12 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2020-07-12 15:30:16 | SEE BUILDING REVIEW NOTES. JW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
N |
Date |
2020-09-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-09-29 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-09-29 |
Time |
17:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-08-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-08-28 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-08-28 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-07-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-07-23 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-23 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2020-07-23 09:59:17 | SHEET : CS-COVER SHEET AND 003 SP1 SPECIFICATIONS MUST | | | BE DIGITALLY SIGNED AND SEAL BY THE DESIGNER. | | 2020-07-23 09:38:35 | DESIGNER MUST DIGITALLY SIGN AND SEAL EACH SHEET | | | SUBMITTED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2020-10-16 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2020-10-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2020-10-16 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-09-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2020-09-14 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-09-14 14:32:12 | ***************************ZONING REVIEW | | | FAILED******************************* | | | | | | THIS PERMIT IS A PART OF AN APPROVED SITE PLAN, WHICH | | | INCLUDES AN APPROVED LANDSCAPE PLAN. | | | | | | THE LANDSCAPE PLANS SUBMITTED WITH THIS PERMIT HAVE TO | | | BE SUBMITTED IN A SEPARATE LANDSCAPE PERMIT. | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-06-29 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2020-06-29 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2020-06-29 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-06-29 12:06:59 | ZONING APPROVAL PER ISPR 20-10. | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING | | | 561-822-1449 | | | [email protected] |
|
|