Plan Review Details - Permit 20060900
| Plan Review Stops For Permit 20060900 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-06-25 17:08:16 | ROUTED TO PLUMBING BIN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-06-25 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-06-25 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-06-17 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2020-06-24 17:43:25 | 06/24/2020 ROUTED TO TIM LARGE DESK. THIS IS A | | | PLUMBING-SUBMITTAL. JG. | | 2020-06-17 13:33:21 | ROUTED TO BLDG MISC 1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-07-14 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2020-07-14 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2020-07-14 |
Time |
15:39 |
Sent To |
I |
|
| Notes |
| 2020-07-14 15:43:53 | THE CONTRACTOR REPLACED THE 6" LATERAL WITH AN 8" | | | LATERAL. THERE IS NO LONGER A PLUMBING CODE VIOLATION. | | | REVOKED REVISION | | | | | | A. BELISLE 7/14/2020 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-06-25 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-06-25 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-06-25 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2020-06-25 06:57:26 | THE SUBMITTED SIGNED & SEALED LETTER FROM MICHAEL | | | COSTELLO, PE IS UNACCEPTABLE. SECTION 704.2 OF THE | | | FLORIDA BUILDING CODE-PLUMBING CLEARLY STATES THAT THE | | | SIZE OF THE DRAINAGE PIPING SHALL NOT BE REDUCED IN | | | SIZE IN THE DIRECTION OF THE FLOW AND THAT IS EXACTLY | | | THE ISSUE WITH THIS INSTALLATION. AN 8-INCH PIPE IS | | | DISCHARGING INTO A 6-INCH PIPE. IT IS IRRELEVANT | | | WHETHER THE SMALLER SIZE PIPE SIZE CAN HANDLE THE | | | FIXTURE DEMAND, THE CODE IS CLEAR. THEREFORE THE | | | CURRENT INSTALLATION IS NON-COMPLIANT AND MUST BE | | | CHANGED IN ORDER TO MEET THE CODE REQUIREMENT AND BE | | | APPROVED.ALSO, REFER TO FBC-PLUMBING SEC.706.2 | | | (OBSTRUCTIONS). | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH BUILDING DIVISION | | | 401 CLEMATIS ST. | | | P.O. BOX 3147 | | | WEST PALM BEACH, FL.33402 | | | [email protected] | | | P: 561-805-6692 | | | F: 561-805-6676 | | | |
|
|
|