Plan Review Details - Permit 20060772
Plan Review Stops For Permit 20060772
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2020-08-04 Cont ID  
Sent By cpuell Date 2020-08-04 Time 15:57 Rev Time 0.00
Received By cpuell Date 2020-08-04 Time 15:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-08-27 Cont ID  
Sent By rmcphers Date 2020-08-27 Time 09:48 Rev Time 0.00
Received By rmcphers Date 2020-08-27 Time 09:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-08-20 Cont ID  
Sent By rmcphers Date 2020-08-20 Time 15:36 Rev Time 0.00
Received By rmcphers Date 2020-08-20 Time 10:03 Sent To  
Notes
2020-08-20 15:36:17NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE SILL HEIGHT FOR THE EMERGENCY EGRESS
 WINDOW LABELED (D) TO COMPLY WITH FBC R310.2.2
 2) PLEASE SHOW THE LIGHT GAGE METAL FRAMING CONNECTIONS
 TO THE SLAB AND THE STRUCTURE ABOVE, WALLS, SOFFIT
 FRAMING, DROP CEILINGS.
 3) PLEASE SHOW ATTIC ACCESS LOCATION AND SIZE TO ALL
 ROOFING SECTIONS - FBC R807.1
 4) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVAL FOR THE SLIDING GLASS DOORS.
 5) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVAL FOR THE ROOFING (TILE AND FLAT DECK)
 PRODUCT APPROVAL SUPPLIED FOR THE TILE ROOFING = PLEASE
 CIRCLE THE TILE ATTACHMENT TO BE USED IN THE PRODUCT
 APPROVAL - IF USING ADHESIVE PLEASE PROVIDE THE PRODUCT
 APPROVAL FOR THE ADHESIVE. PRODUCT APPROVAL FOR THE
 FLAT DECK ROOFING = PLEASE CIRCLE THE ROOFING SYSTEM TO
 BE USED IN THE PRODUCT APPROVAL - IF NEEDED PLEASE
 PROVIDE SIGNED AND SEALED ADDITIONAL ATTACHMENT DETAILS
 FROM AN ARCHITECT OR ENGINEER FOR THE ROOF ZONES 2 AND
 3 WHICH MAY REQUIRE A HIGHER WIND PRESSURE - SEE NOTES
 ON THE PRODUCT APPROVAL.
 6) ON THE ELEVATION CERTIFICATE PROVIDED - SECTION
 (B-8) SHOULD SHOW (AE) NOT (A5).

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-08-27 Cont ID  
Sent By jleahy Date 2020-08-27 Time 12:46 Rev Time 0.00
Received By jleahy Date 2020-08-27 Time 11:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-08-13 Cont ID  
Sent By jleahy Date 2020-08-13 Time 14:10 Rev Time 0.00
Received By jleahy Date 2020-08-13 Time 14:10 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-08-27 Cont ID  
Sent By lcrespo Date 2020-08-27 Time 11:36 Rev Time 0.00
Received By lcrespo Date 2020-08-27 Time 08:31 Sent To  
Notes
2020-08-27 11:38:1208/27/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING/GAS)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-08-12 Cont ID  
Sent By lcrespo Date 2020-08-12 Time 19:30 Rev Time 0.00
Received By lcrespo Date 2020-08-12 Time 10:16 Sent To  
Notes
2020-08-13 17:12:2008/13/2019 2ND GAS/ REVIEW **DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
  
 1. PE PIPE SHALL BE INSTALLED OUTDOOR ONLY IT SHALL NOT
 BE USED WITHIN OR UNDER ANY SLAB PER THE 2017 FC SEC.
 404.17.1. THE METHOD PROVIDED IS NOT APPROVED, THE
 PROHIBITION ON PIPING WITHIN A SLAB IS APPLICABLE TO
 ALL SLABS WITHOUT EXCEPTION.
  
 2. ON SHEET 045 YOU HAVE A COMMENT UNDER NATURAL GAS,
 THIRD ON DOWN IT SHOULD SAY 2.0 PSI NOT 2.0 INCH W.C.
 PLEASE CHANGE PER THE WPB AMENDMENTS TO THE FBC
 SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 3. PLEASE PROVIDED A DETAILED BTU'S SCHEDULE FOR
 APPLIANCE AND LABEL EACH UNIT WITH MODEL TYPE
 ACCORDINGLY ON ISOMETRIC PAGE (LIST THE BTU LOAD OF
 EACH APPLIANCE AND THE TOTAL BTU LOAD ON THE SYSTEM)
 PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 4. PLEASE LABEL EACH TYPE OF PIPE ON ISOMETRIC PER THE
 WPB AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 5. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE
 LENGTH OF ALL CUT SECTIONS OF PIPE PER 2017 FBC RES.
 SECS. G2413.4.1, G2413.4.2.
  
 6. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL
 PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE
 CORRUGATED STAINLESS-STEEL TUBING (IF APPLICABLE) FOR
 EACH PIPE SIZE PER THE WPB AMENDMENTS TO THE FBC
 SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 7. SHOW THE LOCATION OF ALL MP (STEP-DOWN) REGULATORS.
 A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY
 AHEAD OF EACH MP REGULATOR PER THE 2017 FBC RES. SEC.
 G2420.4.
  
 8. A GAS GRILL IS LABELED FOR OUTSIDE USE AND IT SEEMS
 TO BE IN A COVERED PATIO, IF SO PLEASE PROVIDE
 MANUFACTURES RECOMMENDATION FOR A VENTILATION HOOD PER
 THE 2017 FBC RES. SEC. G2408.1.
  
 9. SHOW IN A DIAGRAM HOW THE VENTING DIAGRAMS FOR THE
 GAS GRILL IN A CABINET ON YOUR PLAN AND LOCATION AS PER
 MANUFACTURES SPECIFICATION PER THE 2017 SECTION 503 FBC
 FG.
  
 10. SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE
 PRESSURE REGULATORS. REGULATORS INSTALLED ON THE
 EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR
 INSTALLATION PER THE 2017 FBC RES. SEC. G2421.1.
  
 11. PLEASE SHOW ALL UNIONS IN FRONT OF REGULATOR 1? OF
 EITHER SIDE PER THE 2017 FBC RES. SEC G2421.2.
  
 12. PLEASE LABEL THE SHUTOFF VALVE ON GAS ISOMERIC PER
 THE 2017 FBC RES. SEC. G2401.1.3.
  
 13. SHOW DRIP LEG ON EQUIPMENT INSTALLED PER THE 2017
 FBC RES. SEC. G2419.2.
  
 14. A SUB GAS PERMIT IS REQUIRED BY A LICENSED
 CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS
 TO THE FBC SEC. 105.1.
  
 15. IF GAS UNITS REQUIRE CONDENSATE AND THEY NEED TO BE
 1' AWAY FROM STRUCTURE PER THE 2017 FBC SEC R318.5.
  
 16. SUBMIT ON THE HOUSE PLAN SHOWING THE LOCATION OF
 THE TANKLESS WATER HEATER AND THE LOCATION AND DISTANCE
 OF ANY OPERABLE DOORS OR WINDOWS IN RELATION TO THE
 WATER HEATER. THE LOCATION OF THE WATER HEATER SHALL
 COMPLY WITH THE MANUFACTURER'S INSTALLATION
 INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND-DRAWN PER THE
 WPB AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-08-04 Cont ID  
Sent By fmittner Date 2020-08-04 Time 14:28 Rev Time 0.00
Received By fmittner Date 2020-08-04 Time 14:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-27 Cont ID  
Sent By lcrespo Date 2020-08-27 Time 12:47 Rev Time 0.00
Received By jleahy Date 2020-08-26 Time 13:35 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-08-20 Cont ID  
Sent By cpuell Date 2020-08-20 Time 15:39 Rev Time 0.00
Received By rmcphers Date 2020-08-03 Time 14:02 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2020-08-06 Cont ID  
Sent By lmarchan Date 2020-08-06 Time 14:22 Rev Time 0.00
Received By lmarchan Date 2020-08-03 Time 14:03 Sent To  
Notes
2020-08-06 13:12:51MU-2020-29436 - $22.46 - PAID
2020-08-03 14:03:338/3/20 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-08-27 Cont ID  
Sent By medwards Date 2020-08-27 Time 09:17 Rev Time 0.00
Received By medwards Date 2020-08-27 Time 07:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-08-07 Cont ID  
Sent By hmoser Date 2020-08-07 Time 12:04 Rev Time 0.00
Received By hmoser Date 2020-08-07 Time 09:53 Sent To  
Notes
2020-08-07 12:03:56PLAN DENIED
 1) LOAD CALCULATIONS REQUIRED REFER TO SECTION 312.1
 FBC(M) 2017
 2) NO BUILDING PERMIT APPLICATION PROVIDE IN PACKAGE.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status P Date 2020-08-27 Cont ID  
Sent By rmcphers Date 2020-08-27 Time 09:46 Rev Time 0.00
Received By rmcphers Date 2020-08-27 Time 09:43 Sent To  
Notes
2020-08-27 09:44:50PROVIDED SURVEY SHOWS HOUSE IN AE 7 - DRAWING SHOWS
 HOUSE FFE AT 10.00 NAVD
 PROVIDED SURVEY SHOWS DETACHED GYM AT AE 8 - DRAWING
 SHOWS FFE AT 10.00 NAVD

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2020-08-20 Cont ID  
Sent By rmcphers Date 2020-08-20 Time 15:38 Rev Time 0.00
Received By rmcphers Date 2020-08-20 Time 15:38 Sent To  
Notes
2020-08-20 15:39:16SEE BUILDING PLAN REVIEW

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-08-27 Cont ID  
Sent By lcrespo Date 2020-08-27 Time 11:35 Rev Time 0.00
Received By lcrespo Date 2020-08-27 Time 08:31 Sent To  
Notes
2020-08-27 11:37:4208/27/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-08-12 Cont ID  
Sent By lcrespo Date 2020-08-12 Time 19:28 Rev Time 0.00
Received By lcrespo Date 2020-08-12 Time 10:17 Sent To  
Notes
2020-08-12 19:29:058/12/20 1ST PLUMBING/ REVIEW **DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. SHEET 040 WASHING MACHINE SHALL HAVE ACCESS TO THEM
 WITHOUT MOVING UNIT PER THE 2017 FBC SEC. R2903.9.3.
  
 2. PLEASE SHOW THE LOCATION AND DRAIN TO THE OUTSIDE OF
 THE STEAM UNIT ON THE SECOND FLOOR SUNA PER THE WPB
 AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 3. ON SHEET 043 P SANITARY RISER;
 A. THE TUB IS NOT VENTED OR RE-VENTED OR LABELED PER
 THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION
 ON CONSTRUCTION DOCUMENTS.
  
 B. THE SHOWER IS NOT RE-VENTED PER THE WPB AMENDMENTS
 TO THE FBC SEC. 107.2.1. INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
 C. ON P-2 LAV IT SHOWN ON AN UPRIGHT WYE PICKING UP A
 LAV WHICH REQUIRES A SANITARY DRAINAGE TEE PER THE 2017
 FBC SEC. 3005.1.
  
 D. THE WASHING MACHINES ARE NOT VENTED CORRECTLY, AND
 THE STACK NEEDS TO BE 3" NOT 1 1/2" PER MOST
 MANUFACTURES SPECIFICATION DUE TO THE PUMP DISCHARGE
 VOLUME.
  
 E. THE SHOWERS P-14 AND P-13 REQUIRE A VENT PER THE
 2017 FBC SEC. 3101.2.
  
 F. CLEANOUT REQUIRED AT SECOND (CABANA) STRUCTURE
 WITHIN 10' PER THE 2017 FBC SEC. 3005.2.3.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2020-08-04 Cont ID  
Sent By rgathrig Date 2020-08-04 Time 09:41 Rev Time 0.00
Received By rgathrig Date 2020-08-04 Time 09:38 Sent To  
Notes
2020-08-04 09:41:01THIS REVIEW IIS TO DOCUMENT THE PRIVATE PROVIDER ONLY
 PLANNING AND BUILDING CONSULTANTS, LLC
 STEVEN A. KENNEDY IS THE PRIVATE PROVIDER
 SEE DOCUMENTS IN PROJECTDOX

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2020-08-27 Cont ID  
Sent By rmcphers Date 2020-08-27 Time 09:42 Rev Time 0.00
Received By rmcphers Date 2020-08-27 Time 09:42 Sent To  
Notes
2020-08-27 09:42:49DEFERRED

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-08-20 Cont ID  
Sent By rmcphers Date 2020-08-20 Time 15:37 Rev Time 0.00
Received By rmcphers Date 2020-08-20 Time 15:37 Sent To  
Notes
2020-08-20 15:38:03SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-08-27 Cont ID  
Sent By medwards Date 2020-08-27 Time 09:17 Rev Time 0.00
Received By medwards Date 2020-08-27 Time 09:16 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-08-04 Cont ID  
Sent By fmittner Date 2020-08-04 Time 14:28 Rev Time 0.00
Received By fmittner Date 2020-08-04 Time 14:28 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved