| Plan Review Stops For Permit 20060735 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-05-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-05-03 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-05-03 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2021-05-03 11:55:29 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PRODUCT APPROVALS HAVE NOT BEEN REVIEWED AND | | | APPROVED IN WRITING BY THE ENGINEER OF RECORD. SHOP | | | DRAWING REVIEW STAMP REQUIRED. FBC 107.3.4 - PROVIDE | | | TWO SETS OF PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH | | | ARE REGULATED BY FAC 61G20-3.001 PER FLORIDA STATUTE | | | 553.842 (5) THAT HAVE BEEN REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD. PROVIDE TWO COMPLETE | | | PRODUCT APPROVALS WITH FL OR NOA NUMBERS INCLUDING | | | INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES | | | FOR EACH OF THE DIFFERENT ROOFING MATERIALS, WINDOW | | | (GLASS TYPES), STRUCTURAL MULLIONS AND EXTERIOR DOOR | | | TYPES. ONLY ONE SET IS REQUIRED TO BE UPLOADED FOR | | | ELECTRONICALLY SUBMITTED DOCUMENTS. | | | | | | 2) SUBMIT PRODUCT APPROVALS FOR THE CASEMENT WINDOW AND | | | THE EXTERIOR DOORS. (IF IMPACT RATED WINDOWS ARE NOT | | | USED, SUBMIT PRODUCT APPROVALS, A KEY PLAN AND | | | INSTALLATION FOR THE IMPACT PROTECTION DEVICES.) FAC | | | 61G20 | | | | | | 3) HI-LIGHT OR CIRCLE THE SPECIFIC TYPE, SIZE, DESIGN | | | PRESSURES, ETC. FOR THE SPECIFIC ITEMS IN THE PRODUCT | | | APPROVAL THAT WILL BE INSTALLED. | | | | | | 5) THE CORRECTED ENERGY FORMS ARE NOT SIGNED AND DATED | | | BY THE PREPARER AND OWNER. THE ENERGY FORMS ARE | | | REQUIRED TO BE SIGNED BY THE PREPARER AND THE | | | OWNER/AGENT. FBC ENERGY CONSERVATION SECTION 405.4 | | | | | | 6) WHEN RESUBMITTING, PLEASE PROVIDE A RESPONSE LETTER | | | ADDRESSING EACH ITEM ALONG WITH THE CITY RE-SUBMITTAL | | | FORM. THIS HELP TO SHORTEN THE REVIEW TIME. | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-10-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-07 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-07 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2020-10-07 16:57:28 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT | | | ROOFING MATERIALS, WINDOW (GLASS TYPES), STRUCTURAL | | | MULLIONS AND EXTERIOR DOOR TYPES. ONLY ONE SET IS | | | REQUIRED TO BE UPLOADED FOR ELECTRONICALLY SUBMITTED | | | DOCUMENTS. | | | | | | 2) THE INFORMATION SUBMITTED FOR THE SINGLE HUNG | | | WINDOWS DOES NOT HAVE AN FL# AND DOES NOT APPEAR TO BE | | | THE PRODUCT APPROVAL. SUBMIT THE COMPLETE PRODUCT | | | APPROVAL WITH THE FL COVERSHEET. FBC 107.3.4 | | | | | | 3) THE DOCUMENTS SUBMITTED FOR THE SINGLE HUNG WINDOWS | | | HAVE A DESIGN PRESSURE OF + OR - 50 PSF. THIS IS NOT | | | ADEQUATE FOR WINDOWS C & D IN THE CONVERTED GARAGE OR | | | WINDOW L IN THE TWO STORY HOUSE. THEY HAVE PRESSURES | | | THAT EXCEED -50 PSF. | | | | | | 4) SUBMIT THE PRODUCT APPROVALS FOR THE DOORS AND THE | | | STRUCTURAL MULLIONS. FBC 107.3.4 | | | | | | 5) THE DOCUMENTS SUBMITTED FOR THE SINGLE HUNG WINDOWS | | | ARE FOR NON-IMPACT RATED WINDOWS. IMPACT PROTECTION IS | | | REQUIRED FOR THE GLAZED OPENINGS PER FBC-R301.2.1.2 | | | PROTECTION OF OPENINGS. SUBMIT A KEY PLAN, INSTALLATION | | | SCHEDULE AND PRODUCT APPROVALS FOR THE STORM PANELS. | | | FBC 107 | | | | | | 6) THE ENERGY FORMS ARE REQUIRED TO BE SIGNED BY THE | | | PREPARER AND THE OWNER/AGENT. FBC ENERGY CONSERVATION | | | SECTION 405.4 | | | | | | PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY | | | COMPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR | | | INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL | | | CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110 | | | & FBC 117. | | | | | | FBC 110.1 GENERAL - CONSTRUCTION OR WORK FOR WHICH A | | | PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY | | | THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK | | | SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION | | | PURPOSES UNTIL APPROVED. | | | | | | FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR | | | TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE | | | TO BE MADE AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN | | | APPROVED TESTING LABORATORY OR OTHER APPROVED AGENCY. | | | | | | 7) WHEN RESUBMITTING, PLEASE PROVIDE A RESPONSE LETTER | | | ADDRESSING EACH ITEM ALONG WITH THE CITY RE-SUBMITTAL | | | FORM. THIS HELP TO SHORTEN THE REVIEW TIME. | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2020-07-30 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-30 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2020-07-30 13:44:31 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) BASED ON MY RESEARCH THE BUILDING IN THE REAR WAS | | | ORIGINALLY PERMITTED AS A DETACHED GARAGE. THE WORK THE | | | IS BEING PROPOSED IS TO CONVERT THE GARAGE TO HABITABLE | | | SPACE. ACCORDING TO THE FBC EXISTING BUILDING SECTION | | | 1001.2.1 & 901, THIS IS A CHANGE OF USE WITHIN THE SAME | | | OCCUPANCY CLASSIFICATION AND A LEVEL 3 ALTERATION. | | | PLEASE REVISE NOTE THREE ON SHEET A1 FROM LEVEL 2 | | | ALTERATION. | | | | | | 2) AN IMPACT FEE REVIEW IS REQUIRED TO DETERMINE IF | | | ADDITIONAL IMPACT FEES ARE DUE, WHEN CONVERTING STORAGE | | | SPACE TO HABITABLE SPACE. SEE THE IMPACT FEE REVIEW | | | STOP FOR DETAILS. | | | | | | 3) THIS IS AN ENCLOSED STRUCTURE. PLEASE REVISE NOTE | | | UNDER DESIGN CRITERIA ON SHEET A1. | | | | | | 4) IN THE DESIGN CRITERIA ON SHEET A3 FOR THE MAIN | | | HOUSE LIST THE ROOF HEIGHT AS 10 FEET AND IT IS TWO | | | STORIES. PLEASE CORRECT. FBC 107 | | | | | | 5) ON SHEET A2 THERE ARE SOME INCONSISTENCIES. THE | | | TYPICAL WALL SECTION SHOWS A FLAT SINGLE ASSEMBLY ROOF | | | SYSTEM WITH NO EAVE VENTS. THE ENERGY CALCULATIONS HAS | | | A VENTED ATTIC SPACE AND A CATHEDRAL CEILING. PLEASE | | | CLARIFY AND MAKE CORRECTIONS. FBC 107 | | | | | | 6) ON SHEET A2 THE MECHANICAL DETAILS SHOW THE BATH | | | EXHAUST ROUTED THROUGH THE ATTIC TO THE EAVE AND THERE | | | MAY NOT BE THE SPACE TO DO THIS WITHOUT INTERFERING | | | WITH THE REQUIRED INSULATION IN A SINGLE ASSEMBLY ROOF | | | SYSTEM. PLEASE CLARIFY. FBC ENERGY CONSERVATION | | | | | | 7) SPECIFY THE SIZE OF THE RAFTER/CEILING JOISTS IN THE | | | EXISTING SINGLE ASSEMBLY ROOF SYSTEM. R806.3 VENT AND | | | INSULATION CLEARANCE. WHERE EAVE OR CORNICE VENTS ARE | | | INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF | | | AIR. NOT LESS THAN A 1-INCH (25 MM) SPACE SHALL BE | | | PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING | | | AND AT THE LOCATION OF THE VENT. | | | | | | 8) SPECIFY THE ROOF TO WALL CONNECTIONS. FBC-R301.1 | | | | | | 9) PROVIDE EXTERIOR ELEVATIONS OF THE BUILDING AND | | | SPECIFY THE ROOF SLOPE. FBC 107.2.1 | | | | | | 10) SPECIFY THE REQUIRED WIND LOAD DESIGN PRESSURES FOR | | | ALL EXTERIOR OPENINGS. FBC 107.3.5.3 - PROVIDE WIND | | | DESIGN LOADS AND COMPONENT AND CLADDING DESIGN | | | PRESSURES PURSUANT TO FBC-R301.2. | | | | | | 11) THE VALUATION THAT WAS APPLIED TO THIS PROJECT OF | | | $6865.00 IS TOO LOW. THE IMPACT WINDOWS ALONE FOR BOTH | | | THESE BUILDINGS IS MUCH MORE THAN THAT. PLEASE PROVIDE | | | AN ACCURATE VALUATION. FBC 109.3 BUILDING PERMIT | | | VALUATION. FOR PERMITTING PURPOSES, VALUATION OF | | | BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE | | | TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, | | | INTERIOR FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND | | | DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT; | | | EXCLUDING ONLY LAND VALUE. VALUATION REFERENCES MAY | | | INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL | | | CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT, | | | MEANS, ETC.), AS PUBLISHED BY INTERNATIONAL CODE | | | CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE SET | | | BY THE BUILDING OFFICIAL. | | | | | | 12) PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE | | | PREVIOUSLY COMPLETED WORK TO BE MADE ACCESSIBLE AND | | | OPEN FOR INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION | | | FOR ALL CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO | | | FBC 110 & FBC 117. | | | | | | FBC 110.1 GENERAL - CONSTRUCTION OR WORK FOR WHICH A | | | PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY | | | THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK | | | SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION | | | PURPOSES UNTIL APPROVED. | | | | | | FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR | | | TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE | | | TO BE MADE AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN | | | APPROVED TESTING LABORATORY OR OTHER APPROVED AGENCY. | | | | | | 13) WHEN RESUBMITTING, PLEASE PROVIDE A RESPONSE LETTER | | | ADDRESSING EACH ITEM ALONG WITH THE CITY RE-SUBMITTAL | | | FORM. THIS HELP TO SHORTEN THE REVIEW TIME. | | | | | | | | | | | | | | | | | 2020-07-21 10:16:36 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | | (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) | | | 805-6724 | | | [email protected] | | | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | 1. FBC R 301 FAC9N-3 FOR FLORIDA STATE PRODUCT | | | APPROVALS, PROVIDE THE FOLLOWING ADDITIONAL | | | INFORMATION: COVER SHEET (WWW.FLORIDABUILDING.ORG, THIS | | | WILL INCLUDE THE CODE VERSION, PRODUCT APPROVAL NUMBER, | | | STATUS, GENERAL INFORMATION ABOUT THE PRODUCT). PROVIDE | | | TWO COMPLETE SETS FOR THE PROPOSED WINDOWS USED | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-10-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-20 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-07 |
Time |
08:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-30 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-30 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2020-07-30 10:50:43 | NEED ZONING APPROVAL FOR SECOND METER AND SERVICE | | | JLEAHY |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-04-22 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2021-04-22 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2021-04-22 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2021-04-22 08:49:11 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | | CONDITION(S): | | | 1. WINDOWS S AND R SHALL HAVE A VERTICAL 3/3 LITE | | | PATTERN. (3A1D) | | | 2. WINDOW U CONSISTING OF TWO WINDOWS WITH A 1-INCH | | | MULLION SHALL HAVE A VERTICAL 2/2 LITE PATTERN. (2A1D) | | | 3. ALL LITE PATTERNS SHALL BE VERTICALLY ORIENTED. | | | 4. ALL WINDOWS PREVIOUSLY REPLACED WITHOUT A PERMIT | | | SHALL HAVE A LITE PATTERN ADDED TO EACH WINDOW. THE | | | MUNTIN PROFILE SHALL HAVE AN EXTERNAL DIMENSIONAL | | | PYRAMID PROFILE. | | | 4A. EACH WINDOW E SHALL HAVE A 6/6 LITE PATTERN (2A3D) | | | 4B. WINDOW G SHALL HAVE A VERTICAL 4/4 LITE PATTERN. | | | (4A1D) | | | 4C. WINDOW H SHALL HAVE A VERTICAL 3/3 LITE PATTERN. | | | (3A1D) | | | 4D. EACH WINDOW I SHALL HAVE A VERTICAL 3/3 LITE | | | PATTERN. (3A1D) | | | 4E. ALL REMAINING WINDOWS NOT SPECIFICALLY OUTLINED IN | | | THESE CONDITIONS SHALL HAVE A LITE PATTERN OF VERTICAL | | | 4/4 OR VERTICAL 3/3 BASED ON THE ORIGINAL WINDOWS THAT | | | WERE REMOVED WITHOUT A PERMIT. | | | | | | AARON BORNGRABER, AICP | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-10-08 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-10-08 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-10-08 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2020-10-08 14:39:45 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | | | 1. PROVIDE EXISTING ELEVATIONS AND/OR PHOTOS OF THE | | | REAR STRUCTURE TO BE CONVERTED. | | | 2. REVISE ACCESSORY STRUCTURE NORTH ELEVATION BATHROOM | | | WINDOW TO HAVE SQUARE PROPORTIONS WITH A CASEMENT | | | (HOPPER) WINDOW. | | | 3. ALL WINDOW REPLACEMENT WORK REQUIRES TO FOLLOW THE | | | WINDOW PERMIT APPLICATION EXAMPLE. PLEASE EMAIL STAFF | | | AT [email protected] TO REQUEST THE EXAMPLE. AT | | | MINIMUM, STAFF NEEDS TO KNOW THE EXISTING WINDOWS AND | | | THE PROPOSED WINDOWS EXTERIOR FRAME, GLASS GLAZING, | | | LITE PATTERN, MUNTIN PROFILE AND MULLION WIDTH. A PHOTO | | | OF EACH ELEVATION WITH EACH WINDOW MARKED. | | | 4. OPENING J IS A SLIDING GLASS DOOR. PROVIDE REASON | | | WHY ITS GOING TO BE A PAIRED SINGLE-HUNG WINDOW. | | | PROVIDE A PHOTO OF THIS OPENING. | | | 5. THE WINDOWS ON THE MAIN HOUSE WILL NEED TO BE | | | MODIFIED TO RECREATE THE PREVIOUS ORIGINAL WINDOWS | | | APPEARANCE. MUNTINS WITH AN EXTERNAL DIMENSIONAL | | | PYRAMID PROFILE WILL BE REQUIRED TO BE ATTACHED THE | | | GLASS. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-08-05 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-08-05 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2020-08-05 14:38:12 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | | | 1. PROVIDE EXISTING ELEVATIONS AND/OR PHOTOS OF THE | | | REAR STRUCTURE TO BE CONVERTED. | | | 2. ALL WINDOW REPLACEMENT WORK REQUIRES TO FOLLOW THE | | | WINDOW PERMIT APPLICATION EXAMPLE. PLEASE EMAIL STAFF | | | AT [email protected] TO REQUEST THE EXAMPLE. AT | | | MINIMUM, STAFF NEEDS TO KNOW THE EXISTING WINDOWS AND | | | THE PROPOSED WINDOWS EXTERIOR FRAME, GLASS GLAZING, | | | LITE PATTERN, MUNTIN PROFILE AND MULLION WIDTH. A PHOTO | | | OF EACH ELEVATION WITH EACH WINDOW MARKED. | | | 3. OPENING J IS A SLIDING GLASS DOOR. PROVIDE REASON | | | WHY ITS GOING TO BE A PAIRED SINGLE-HUNG WINDOW. | | | 4. STAFF IS UNDER THE IMPRESSION THE WINDOWS HAVE | | | ALREADY BEEN INSTALLED. ARE NEW WINDOWS BEING INSTALLED | | | OR IS THIS PERMIT TO BRING THE PREVIOUSLY INSTALLED | | | WINDOWS INTO COMPLIANCE? PLEASE CLARIFY. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-05-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-05-03 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-20 |
Time |
10:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-10-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-20 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-06 |
Time |
16:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-08-10 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2020-08-10 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-06-18 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2020-06-18 15:31:22 | ROUTED TO BLDG. MISC 1 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-30 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-30 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2020-07-30 13:24:04 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | IMPACT FEES - DIGITAL SUBMITTALS | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-10-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-10-07 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-10-07 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-07-30 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-30 |
Time |
07:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-10-07 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-10-07 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-10-07 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2020-10-07 16:28:36 | 10/07/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-07-30 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-07-30 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2020-07-30 11:03:51 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 20060735 816 L A KIRKSEY ST | | | | | | 1ST REVIEW | | | PLUMBING COMMENTS: DENIED | | | 1. RE: PLAN SHEET MEP; PER WPB FBC 107.2.1, CLEARLY | | | INDICATE ON THE PLAN VIEW AND THE SANITARY RISER | | | DIAGRAM HOW THE AUTOMATIC CLOTHES WASHER IS CONNECTED | | | TO THE SANITARY SYSTEM. INCLUDE VENT AND FIXTURE DRAIN | | | WITH SIZING. | | | 2. WILL THE NEW SANITARY BUILDING DRAIN AND SEWER | | | CONNECT TO THE EXISTING BUILDING SEWER OR SEPARATELY TO | | | THE CITY SEWER. PER WPB FBC 107.2.1, CLARIFY, PROVIDE | | | ROUTING AND DETAILS ON THE SITE PLAN. SHOW LOCATION(S) | | | OF REQUIRED CLEANOUT (S) COMPLYING WITH FBC RES | | | P3005.2.2, P3005.2.3 AND P3005.2.4. | | | 3. RE: PLAN SHEET MEP; THE ELECTRICAL PANEL INDICATES A | | | 12 KW TANKLESS WATER HEATER. THE ENERGY CALCULATION | | | SHEET (PG 2) IN SUPPORTING DOCUMENTS INDICATE A 30 | | | GALLON ELECTRIC TANK (STORAGE) TYPE WATER HEATER. PER | | | WPB FBC 107.2.1, CLARIFY. AMEND WHICHEVER OF THE TWO | | | DOCUMENTS THAT IS INCORRECT. ADDITIONALLY, SHOW | | | LOCATION OF THE WATER HEATER ON THE FLOOR PLAN AND | | | SUBMIT MANUFACTURER'S SPECIFICATION/INSTALLATION MANUAL | | | FOR THE WATER HEATER. PROVIDE CALCULATIONS TO SHOW HOT | | | WATER DEMAND WILL BE SUPPORTED BY THE WATER HEATER. | | | ALSO NOTE THAT PLUMBING NOTE #7 REQUIRES A GALVANIZED | | | DRIP PAN AND DRAIN UNDER THE WATER HEATER. THIS IS ONLY | | | REQUIRED BY CODE FOR TANK (STORAGE) TYPE WATER HEATERS. | | | 4. RE: PLAN SHEET MEP; PER WPB FBC 107.2.1 AND FBC RES | | | P2903.5, PLUMBING NOTE #5 SHALL BE AMENDED TO STATE | | | "THE FLOW VELOCITY OF THE WATER DISTRIBUTION SYSTEM | | | SHALL BE CONTROLLED TO REDUCE THE POSSIBILITY OF WATER | | | HAMMER. WATER-HAMMER ARRESTORS SHALL BE INSTALLED IN | | | ACCORDANCE WITH THE MANUFACTURER?S INSTRUCTIONS. | | | WATER-HAMMER ARRESTORS SHALL CONFORM TO ASSE 1010". | | | ADDITIONALLY, THE VERBAGE AND POSSIBLE LACK OF | | | PUNCTUATION IN THE NOTE REFERENCING 604.9 WATER HAMMER | | | ARRESTORS IS CONFUSING. PLEASE CLARIFY. | | | 5. RE: PLAN SHEET MEP; PER WPB FBC 107.2.1 AND FBC RES | | | P3005.3, PLUMBING NOTE #11 SHALL BE AMENDED TO STATE | | | "?HORIZONTAL DRAINAGE PIPING SHALL BE INSTALLED IN | | | UNIFORM ALIGNMENT AT UNIFORM SLOPES NOT LESS THAN 1/4 | | | INCH PER FOOT (2-PERCENT SLOPE) FOR 21/2 INCH DIAMETER | | | AND LESS, AND NOT LESS THAN 1/8 INCH PER FOOT | | | (1-PERCENT SLOPE) FOR DIAMETERS OF 3 INCHES OR MORE". | | | 6. RE: PLAN SHEET MEP; PER WPB FBC 107.2.1, FBC PL | | | 606.3 AND FBC RES 2601.1, SHOW ACCESSIBLE LOCATION OF | | | SHUT OFF VALES FOR THE STACKED WASHER/DRYER COMBO. | | | 7. VALUE OF JOB IS INCONSISTENTLY PROVIDED ON SEPARATE | | | PERMITS AND DOES NOT REFLECT THE VALUE INDICATED ON THE | | | SUPPORTING DOCUMENT "REQUEST FOR REDUCTION OF FINE". | | | PROVIDE AN ACCURATE VALUATION OF ALL WORK AND COST. | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL (1)CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | PAGES WHICH ARE REPLACED ARE REQUIRED TO HAVE A DIGITAL | | | SIGNATURE IN ACCORDANCE WITH FS471, FAC61G15-23, OR | | | APPLICANT IS TO PROVIDE ONE PAPER ORIGINAL AFTER ALL | | | REVIEWS HAVE PASSED. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-246-0882 MOBILE | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2021-05-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-05-03 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-05-03 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2021-05-03 11:40:51 | THE PLANS ARE NOT SIGNED DIGITALLY BY THE ENGINEER. | | | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | | THE ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE | | | THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER | | | VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE | | | BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | | ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS | | | REQUIRED TO BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER | | | FACSIMILES OF THE SIGNATURE ARE ACCEPTABLE. FS 471 & | | | 61G15 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-12-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-12-01 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-12-01 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2020-12-01 14:01:50 | PAPER PLANS ON FILE, SIGNATURE AND SEAL APPROVED. ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-10-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-07 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-07 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2020-10-07 17:09:34 | THE PLANS ARE NOT SIGNED DIGITALLY BY THE ENGINEER. | | | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | | THE ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE | | | THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER | | | VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE | | | BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | | ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS | | | REQUIRED TO BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER | | | FACSIMILES OF THE SIGNATURE ARE ACCEPTABLE. FS 471 & | | | 61G15 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-07-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-07-29 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-07-29 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2020-07-29 08:42:55 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | PAPER PLANS SUBMITTED, PREPARED BY CARL G FORBES, PE | | | DATED 5/19/20. | | | | | | PROVISO: PAGES WHICH ARE REPLACED ARE REQUIRED TO HAVE | | | A DIGITAL SIGNATURE IN ACCORDANCE WITH FS471, | | | FAC61G15-23, OR APPLICANT IS TO PROVIDE ONE PAPER | | | ORIGINAL AFTER ALL REVIEWS HAVE PASSED. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-04-22 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2021-04-22 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2021-04-21 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2021-04-22 08:49:31 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | | CONDITION(S): | | | 1. WINDOWS S AND R SHALL HAVE A VERTICAL 3/3 LITE | | | PATTERN. (3A1D) | | | 2. WINDOW U CONSISTING OF TWO WINDOWS WITH A 1-INCH | | | MULLION SHALL HAVE A VERTICAL 2/2 LITE PATTERN. (2A1D) | | | 3. ALL LITE PATTERNS SHALL BE VERTICALLY ORIENTED. | | | 4. ALL WINDOWS PREVIOUSLY REPLACED WITHOUT A PERMIT | | | SHALL HAVE A LITE PATTERN ADDED TO EACH WINDOW. THE | | | MUNTIN PROFILE SHALL HAVE AN EXTERNAL DIMENSIONAL | | | PYRAMID PROFILE. | | | 4A. EACH WINDOW E SHALL HAVE A 6/6 LITE PATTERN (2A3D) | | | 4B. WINDOW G SHALL HAVE A VERTICAL 4/4 LITE PATTERN. | | | (4A1D) | | | 4C. WINDOW H SHALL HAVE A VERTICAL 3/3 LITE PATTERN. | | | (3A1D) | | | 4D. EACH WINDOW I SHALL HAVE A VERTICAL 3/3 LITE | | | PATTERN. (3A1D) | | | 4E. ALL REMAINING WINDOWS NOT SPECIFICALLY OUTLINED IN | | | THESE CONDITIONS SHALL HAVE A LITE PATTERN OF VERTICAL | | | 4/4 OR VERTICAL 3/3 BASED ON THE ORIGINAL WINDOWS THAT | | | WERE REMOVED WITHOUT A PERMIT. | | | | | | AARON BORNGRABER, AICP | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2020-10-08 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-10-08 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-10-08 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2020-10-20 08:45:43 | AARON | | | | | | THEY HAVE ALSO PLACED A SEPARATE METER ON THIS | | | STRUCTURE, NOT SURE IF IT OK PER ZONING. JAKE | | 2020-10-08 14:42:18 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | | | 1. PROVIDE EXISTING ELEVATIONS AND/OR PHOTOS OF THE | | | REAR STRUCTURE TO BE CONVERTED. | | | 2. REVISE ACCESSORY STRUCTURE NORTH ELEVATION BATHROOM | | | WINDOW TO HAVE SQUARE PROPORTIONS WITH A CASEMENT | | | (HOPPER) WINDOW. | | | 3. ALL WINDOW REPLACEMENT WORK REQUIRES TO FOLLOW THE | | | WINDOW PERMIT APPLICATION EXAMPLE. PLEASE EMAIL STAFF | | | AT [email protected] TO REQUEST THE EXAMPLE. AT | | | MINIMUM, STAFF NEEDS TO KNOW THE EXISTING WINDOWS AND | | | THE PROPOSED WINDOWS EXTERIOR FRAME, GLASS GLAZING, | | | LITE PATTERN, MUNTIN PROFILE AND MULLION WIDTH. A PHOTO | | | OF EACH ELEVATION WITH EACH WINDOW MARKED. | | | 4. OPENING J IS A SLIDING GLASS DOOR. PROVIDE REASON | | | WHY ITS GOING TO BE A PAIRED SINGLE-HUNG WINDOW. | | | PROVIDE A PHOTO OF THIS OPENING. | | | 5. THE WINDOWS ON THE MAIN HOUSE WILL NEED TO BE | | | MODIFIED TO RECREATE THE PREVIOUS ORIGINAL WINDOWS | | | APPEARANCE. MUNTINS WITH AN EXTERNAL DIMENSIONAL | | | PYRAMID PROFILE WILL BE REQUIRED TO BE ATTACHED THE | | | GLASS. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | | | | | | | THIS PROPERTY IS ZONED CP-POR-C2, WHICH ALLOWS 14 | | | DWELLING UNITS PER ACRE. THE PROEPRTY IS .15 ACRES, | | | ALLOWING 2.1 OR 2 (TWO) UNITS. | | 2020-10-07 08:42:08 | NOTE TO ZONING THIS STRUCTURE IS PROPOSING TO ADD | | | ANOTHER METER TO THE PROPERTY FOR JUST THE GUEST HOUSE. | | | THEY WILL END UP WITH ONE ON THE MAIN HOUSE AND ONE ON | | | THE GUEST HOUSE |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-08-05 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-08-05 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2020-08-05 14:37:55 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | | | 1. PROVIDE EXISTING ELEVATIONS AND/OR PHOTOS OF THE | | | REAR STRUCTURE TO BE CONVERTED. | | | 2. ALL WINDOW REPLACEMENT WORK REQUIRES TO FOLLOW THE | | | WINDOW PERMIT APPLICATION EXAMPLE. PLEASE EMAIL STAFF | | | AT [email protected] TO REQUEST THE EXAMPLE. AT | | | MINIMUM, STAFF NEEDS TO KNOW THE EXISTING WINDOWS AND | | | THE PROPOSED WINDOWS EXTERIOR FRAME, GLASS GLAZING, | | | LITE PATTERN, MUNTIN PROFILE AND MULLION WIDTH. A PHOTO | | | OF EACH ELEVATION WITH EACH WINDOW MARKED. | | | 3. OPENING J IS A SLIDING GLASS DOOR. PROVIDE REASON | | | WHY ITS GOING TO BE A PAIRED SINGLE-HUNG WINDOW. | | | 4. STAFF IS UNDER THE IMPRESSION THE WINDOWS HAVE | | | ALREADY BEEN INSTALLED. ARE NEW WINDOWS BEING INSTALLED | | | OR IS THIS PERMIT TO BRING THE PREVIOUSLY INSTALLED | | | WINDOWS INTO COMPLIANCE? PLEASE CLARIFY. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|