Plan Review Details - Permit 20060662
Plan Review Stops For Permit 20060662
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-06-18 Cont ID  
Sent By cthroop Date 2020-06-18 Time 15:09 Rev Time 0.00
Received By cthroop Date 2020-06-18 Time 15:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-06-16 Cont ID  
Sent By cthroop Date 2020-06-16 Time 12:11 Rev Time 0.00
Received By cthroop Date 2020-06-16 Time 09:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-06-18 Cont ID  
Sent By jleahy Date 2020-06-18 Time 14:22 Rev Time 0.00
Received By jleahy Date 2020-06-18 Time 14:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-06-16 Cont ID  
Sent By jpearson Date 2020-06-16 Time 09:47 Rev Time 0.00
Received By jpearson Date 2020-06-16 Time 09:47 Sent To  
Notes
2020-06-16 09:47:36CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. LOAD CALCULATION IS NOT CODE COMPLIANT. PROVIDE
 ACCURATE LOAD CALCULATION FOR SERVICE, INCLUDE EXISTING
 AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE IS
 ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2
 2. BASED ON LOADS STATED, THE SERVICE IS UNDERSIZED FOR
 THE TOTAL LOAD. PROVIDE CORRECTION. NEC 215.2, 220,
 408.30; FBC RE E3602.2
 3. IF SERVICE IS TO BE REPLACED, PROVIDE AVAILABLE
 SHORT CIRCUIT CALCULATION FOR SERVICE INCLUDING
 INFORMATION FROM THE POWER COMPANY STATING WHAT THE
 AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE SERVICE TO
 CONFIRM THE STATED AIC RATING OF THE SERVICE EQUIPMENT
 IS ADEQUATE. NEC 110.9, 110.10; FBC RE E3606.3
 4.PROVIDE SPEC SHEET FOR REFRIGERATOR TO BE USED IN
 GAME ROOM. I HAVE NEVER SEEN ONE THAT IS ONLY 170 VA.
 NEC 110.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-06-18 Cont ID  
Sent By cthroop Date 2020-06-18 Time 15:09 Rev Time 0.00
Received By cthroop Date 2020-06-18 Time 10:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-17 Cont ID  
Sent By lmarchan Date 2020-06-17 Time 15:09 Rev Time 0.00
Received By lmarchan Date 2020-06-15 Time 15:55 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-06-16 Cont ID  
Sent By medwards Date 2020-06-16 Time 12:11 Rev Time 0.00
Received By cthroop Date 2020-06-16 Time 09:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-06-16 Cont ID  
Sent By tklarge Date 2020-06-16 Time 12:11 Rev Time 0.00
Received By cthroop Date 2020-06-16 Time 09:46 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-06-18 Cont ID  
Sent By jleahy Date 2020-06-18 Time 14:23 Rev Time 0.00
Received By jleahy Date 2020-06-18 Time 14:23 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-06-16 Cont ID  
Sent By jpearson Date 2020-06-16 Time 07:37 Rev Time 0.00
Received By jpearson Date 2020-06-16 Time 07:37 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-06-17 Cont ID  
Sent By llouie Date 2020-06-17 Time   Rev Time  
Received By llouie Date 2020-06-17 Time   Sent To  
Notes
2020-06-17 15:02:34* MASTER PERMIT #19071321
  
 * NO KITCHEN FACILITY PERMITTED AS ACCESSORY DWELLING
 UNITS ARE PROHIBITED IN THE SF7 ZONING DISTRICT.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved