| Plan Review Stops For Permit 20060550 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-04-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-23 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-23 |
Time |
09:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-03-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-24 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-24 |
Time |
06:27 |
Sent To |
|
|
| Notes |
| 2021-03-24 07:33:53 | PLAN REVIEW - BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 1. COMPLETE | | | | | | 2. COMPLETE | | | | | | 3. COMPLETE | | | | | | 4. COMPLETE | | | | | | NEW COMMENTS: | | | | | | 5. PROVIDE THE FLORIDA STATE PRODUCT APPROVAL COVER | | | SHEETS FOR PRODUCT APPROVALS FL11120.2 (WINDOWS) AND | | | FL23507.1 (DOORS). THEY SHOW THE APPROVAL NUMBER, CODE | | | VERSION, AND STATUS, FBC R 301. | | | (MIAMI DADE NOAS ARE OK, THEY DO NOT NEED FL COVER | | | PAGE). | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-10-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-10-07 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-10-07 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2020-10-07 13:55:54 | PLAN REVIEW - BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 1. (BASED ON THE ICC BUILDING VALUATION TABLES, THE | | | VALUE FOR A 154 SQ. FT ADDITION WOULD BE $18,859.00. | | | CREDITS ARE BEING APPLIED BASED ON THE EXISTING TWO | | | EXTERIOR WALL, NO PLUMBING ELEMENTS AND NO ADDITIONAL | | | MECHANICAL EQUIPMEMT. THE VALUE HAS BEED ADJUSTED FROM | | | $7,000.00 TO $10,000.00.) | | | | | | 2. PROVIDE A SOILS REPORT. NOT ADDRESSED | | | FBC 1803.1 GENERAL.GEOTECHNICAL INVESTIGATIONS SHALL BE | | | CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE | | | REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL | | | INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY | | | TESTING OR ENGINEERING CALCULATIONS, SUCH | | | INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED | | | DESIGN PROFESSIONAL. | | | | | | (THIS PROPERTY IS LOCATED WITHIN AN AREA OF | | | QUESTIONABLE SOILS PER CITY CODE.) ( BASED ON THE | | | OFFICIAL ZONING MAP REFERRED TO IN SECTION 53-2 OF | | | CHAPTER 53 OF THE CITY CODE OF WEST PALM BEACH, | | | FLORIDA, 1962, ADOPTED JUNE 15, 1964, YOUR PROPERTY, | | | LOCATED AT 1335 9TH STREET, W.P.B., FL, IS LOCATED IN | | | AN AREA OF QUESTIONABLE SOILS AND DOES REQUIRE | | | INVESTIGATION BY A GEOTECHNICAL ENGINEER WITH ITS | | | SUBSEQUENT SOILS REPORT AND DENSITY TESTING. | | | THIS ONLY RELIEVES YOU FROM THE STATUTORY REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE. THERE MAY BE OTHER | | | ENTITIES, SUCH AS YOUR DESIGN PROFESSIONAL OR YOUR | | | LENDING INSTITUTION THAT MAY REQUIRE THE ABOVE | | | MENTIONED INVESTIGATION.) | | | | | | 3. COMPLETE | | | | | | 4. COMPLETE | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-06-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-06-24 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-06-24 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2020-06-24 10:10:34 | PLAN REVIEW - BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. VALUE CANNOT BE DETERMINED AT THIS TIME. THERE IS | | | CONFLICTING INFORMATION ON COVER PAGE CS.1 | | | A) PLAN DEMENSIONS INDICATE ADDITION SHALL BE 22 FEET X | | | 7 FEET. | | | B) NOTE ON PLAN INDICATES ADDITION IS 406 SQ. FT. | | | C) THERE IS A SECOND DEMENSION ON PLAN INDICATING THE | | | ADDITION IS 36.05 FEET. | | | PLEASE CLARIFY. VALUE WILL BE EVALUATED UPON | | | RE-SUBMITTAL OF CORRECTED PLANS. | | | | | | 2. PROVIDE A SOILS REPORT. | | | FBC 1803.1 GENERAL.GEOTECHNICAL INVESTIGATIONS SHALL BE | | | CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE | | | REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL | | | INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY | | | TESTING OR ENGINEERING CALCULATIONS, SUCH | | | INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED | | | DESIGN PROFESSIONAL. | | | | | | 3. PROVIDE AN ENERGY SUBMITTAL. SEE COMMENTS UNDER | | | MECHANICAL REVIEW. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 4. PRODUCT APPROVAL FL-73778 FOR PROPOSED WINDOWS IS | | | FOR NON-IMPACT RATED WINDOWS. | | | PROVIDE A PRODUCT APPROVAL FOR A IMPACT RATED WINDOWS | | | OR PROVIDE A SCHEDULE FOR OPENING PROTECTION WITH | | | PRODUCT APPROVALS OF SHUTTER TO BE USED. | | | | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-03-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-03-24 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-24 |
Time |
06:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-10-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-05 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-05 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-06-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-06-24 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-06-24 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2020-06-24 09:48:27 | PLAN REVIEW - ELECTRICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE AN UPDATED PANEL SCHEDULE. | | | PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-04-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-23 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-01 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-03-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-30 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-18 |
Time |
07:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-12-23 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-12-23 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-24 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-07-28 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-06-15 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2020-06-15 14:32:36 | ROUTED TO ZONING |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2021-08-05 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-08-05 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-06-02 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2021-08-05 09:52:52 | RECEIPT MU-2021-30615 NO FEES DUE PER IMPACT OFFICE. | | | LEM | | 2021-06-02 09:00:33 | 6/2/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2021-04-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-23 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-23 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2021-04-23 11:33:40 | 2ND NOTICE: | | | | | | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-06-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-06-24 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-06-24 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2020-06-24 09:38:19 | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-03-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-30 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-30 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2020-09-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-28 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-28 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2020-09-28 08:54:24 | PLEASE PROVIDE EQUIPMENT SIZING CALCULATIONS FOR | | | RXISTING UNIT. YOU ARE ADDING CONDITIONED SPACE TO THE | | | EXISTING UNIT. PLEASE SHOW THE EXISTING UNIT IS SIZED | | | TO CONDITION THE ADDITIONAL LOAD. FBC EC R403.7 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-06-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-06-24 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-06-24 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2020-06-24 09:58:44 | PLAN REVIEW - MECHANICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTE: THE ADDITION COMMUNICATES WITH THE EXISTING | | | CONDITIONED SPACE. MECH. PERMIT 18120755 | | | | | | MECHANICAL PERMIT REQUIRED. | | | | | | 1. SUBMIT AN ENERGY COMPLIANCE REPORT FOR THE ADDITION | | | PER FBC EC R101.5.1.1 | | | | | | R101.5.1.1.1BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE CODE OFFICIAL TO DEMONSTRATE | | | CODE COMPLIANCE BY THIS METHOD. ALTERNATIVELY, A | | | FLORIDA RESCHECK COMPUTER PRINTOUT MAY BE SUBMITTED TO | | | DEMONSTRATE COMPLIANCE BY SECTIONS R402, R403 AND R404. | | | | | | 2017 FBC EXISTING BUILDING, CHPT. 11, ADDITIONS | | | | | | 2017 FBC ENERGY, CHAPTER 5 (RE), EXISTING BUILDINGS, | | | | | | R303.10 REQUIRED HEATING. | | | | | | SUBMIT WINDOW PRODUCT DATA SHEETS TO VERIFY U-FACTORS | | | AND SHGC VALUES- SECTION R405. | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2020-06-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-06-24 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-06-24 |
Time |
07:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-03-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-18 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-18 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2021-03-18 10:51:40 | ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO | | | STORAGE.ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-09-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-24 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-09-24 |
Time |
17:09 |
Sent To |
|
|
| Notes |
| 2020-09-24 17:10:48 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | 2ND SIGNATURE REVIEW APPROVED BY PAPER SUBMITTALS. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-06-23 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-06-23 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-06-23 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2020-06-23 15:46:57 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | SIGNATURE REVIEW APPROVED BY ORIGINAL PAPER PLANS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-12-14 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-12-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2020-12-14 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-07-23 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-07-23 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2020-07-23 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-07-23 11:25:06 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PLEASE PROVIDE A SURVEY OF THE PROPERTY INDICATING | | | ALL THE SETBACKS OF ALL STRUCTURES (CONCRETE BLOCK | | | PATIO) FROM ALL PROPERTY LINES. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | IF THE FORM IS TEMPORARILY UNAVAILABLE, PLEASE REQUEST | | | THAT IT BE SENT TO YOU BY EMAILING [email protected] | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | TTY: 800.955.8771 | | | E: [email protected] | | | W: WPB.ORG | | | |
|
|