Plan Review Details - Permit 20060404
Plan Review Stops For Permit 20060404
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2020-09-12 Cont ID  
Sent By shill Date 2020-09-12 Time 14:57 Rev Time 0.00
Received By shill Date 2020-09-12 Time 14:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-09-08 Cont ID  
Sent By jbrooks Date 2020-09-08 Time 10:03 Rev Time 0.00
Received By jbrooks Date 2020-09-08 Time 09:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-08-18 Cont ID  
Sent By jbrooks Date 2020-08-18 Time 14:41 Rev Time 0.00
Received By jbrooks Date 2020-08-18 Time 14:41 Sent To  
Notes
2020-08-18 14:41:23JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM
 ALTERNATE: CONTACT SAMANTHA HILL (561) 805-6724
 [email protected]
  
 1ST REVIEW: FBC 2017 6TH EDITION
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. GENERAL LIMITATION #7 IS SPECIFICALLY REFERRED TO IN
 THIS NOA. PERIMETER AND CORNER AREAS SHALL COMPLY WITH
 THE ENHANCED UPLIFT PRESSURE REQUIREMENTS OF THESE
 AREAS. FASTENER DENSITIES SHALL BE INCREASED FOR BOTH
 INSULATION AND BASE SHEET AS CALCULATED IN COMPLIANCE
 WITH ROOFING APPLICATION STANDARD RAS 117. CALCULATIONS
 PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED
 PROFESSIONAL ENGINEER, REGISTERED ARCHITECT, OR
 REGISTERED ROOF CONSULTANT. PROVIDE TWO SETS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-17 Cont ID  
Sent By pvalenti Date 2020-06-17 Time 17:42 Rev Time 0.00
Received By pvalenti Date 2020-06-17 Time 17:42 Sent To  
Notes
2020-06-17 17:45:42PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107, PROVIDE SPECIFIC DETAILS FOR THE FLAT ROOF
 SECTION INCLUDING PRODUCT APPROVALS (WITH SYSTEM
 IDENTIFIED) AND ENGINEER'S SIGNED AND SEALED FASTENER
 SPACING FOR EACH ZONE.

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2020-09-02 Cont ID  
Sent By aborngra Date 2020-09-02 Time 16:04 Rev Time 0.00
Received By aborngra Date 2020-09-02 Time 16:04 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2020-08-25 Cont ID  
Sent By aborngra Date 2020-08-25 Time 16:17 Rev Time 0.00
Received By aborngra Date 2020-08-25 Time 16:17 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-06-15 Cont ID  
Sent By aborngra Date 2020-06-15 Time 16:23 Rev Time 0.00
Received By aborngra Date 2020-06-15 Time 16:23 Sent To  
Notes
2020-06-15 16:23:38TILE SHALL HAVE AN EARTH TONE COLOR

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2020-09-18 Cont ID  
Sent By jgomez Date 2020-09-18 Time 09:06 Rev Time 0.00
Received By jgomez Date 2020-09-17 Time 18:22 Sent To I
Notes
2020-09-17 18:22:23ROUTED DOCUMENT FOR SIGNATURE "S5"

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2020-09-18 Cont ID  
Sent By jgomez Date 2020-09-18 Time 09:06 Rev Time 0.00
Received By jgomez Date 2020-09-14 Time 08:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-09-12 Cont ID  
Sent By shill Date 2020-09-12 Time 14:58 Rev Time 0.00
Received By shill Date 2020-09-08 Time 13:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-09-08 Cont ID  
Sent By jbrooks Date 2020-09-08 Time 10:05 Rev Time 0.00
Received By jbrooks Date 2020-09-01 Time 13:30 Sent To  
Notes
2020-09-01 13:30:27CONVERTED TO DIGITAL. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-26 Cont ID  
Sent By rsklarew Date 2020-08-26 Time 09:39 Rev Time 0.00
Received By rsklarew Date 2020-08-18 Time 12:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-17 Cont ID  
Sent By pvalenti Date 2020-06-17 Time 17:45 Rev Time 0.00
Received By pvalenti Date 2020-06-15 Time 14:45 Sent To  
Notes
2020-06-15 16:35:57ROUTED TO PVALENTI
2020-06-15 14:45:17ROUTED TO HISTORIC BIN

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-09-18 Cont ID  
Sent By jgomez Date 2020-09-18 Time 09:04 Rev Time 0.00
Received By jgomez Date 2020-09-18 Time 09:04 Sent To I
Notes
2020-09-18 09:06:03RAS 117 CALCULATIONS WITH ENGINEER'S ORIGINAL
 SEAL/SIGNATURE MATCHES APPROVED ONE. JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-09-12 Cont ID  
Sent By shill Date 2020-09-12 Time 14:58 Rev Time 0.00
Received By shill Date 2020-09-12 Time 14:58 Sent To  
Notes
2020-09-12 14:58:35SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN
 ORIGINAL.
  
 EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN
 TO ME, OR YOU CAN MAIL (OR DROP OFF) ONE ORIGINAL
 SIGNED AND SEALED PAPER ORIGINAL WITH A WET SIGNATURE
 TO:
  
 SAMANTHA M. HILL
 CHIEF PLANS EXAMINER
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6724.
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-09-08 Cont ID  
Sent By jbrooks Date 2020-09-08 Time 10:03 Rev Time 0.00
Received By jbrooks Date 2020-09-08 Time 10:03 Sent To  
Notes
2020-09-08 10:04:23JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM
 ALTERNATE: CONTACT PETER VALENTI (561) 805-6673
 [email protected]
  
 1ST REVIEW: FBC 2017 6TH EDITION
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
  
 FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN
 ORIGINAL.
 EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN
 TO ME, OR YOU CAN MAIL ONE ORIGINAL SIGNED AND SEALED
 PAPER ORIGINAL WITH A WET SIGNATURE TO:
 PETER VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6673.
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved