| Plan Review Stops For Permit 20060348 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2022-05-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-23 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-23 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-05-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-10 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-10 |
Time |
10:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-10-09 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-09 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-09 |
Time |
14:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-08-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-24 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-24 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2020-08-24 08:23:18 | PARKING LOT EXPANSION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) SHOW THE HANDI CAP RAMP LENGTH. (HAND RAILS MAY BE | | | REQUIRED) | | | 2) SHOW THE HAND RAILS IF REQUIRED FOR THE RAMP FBC | | | ACCESSIBILITY 405.8 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-06-24 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-06-24 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2020-06-24 12:39:52 | PARKING LOT EXPANSION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) DRAWING E-002 SHOWS CODE USED FOR DESIGN AS FBC 2014 | | | - SHOULD BE FBC 2017 | | | 2) PLEASE SHOW ACCESSIBLE PARKING SPACE SIZE TO COMPLY | | | WITH FBC ACCESSIBILITY 502.2 | | | 3) PLEASE SHOW ACCESSIBLE PARKING ACCESS AISLE SIZE AND | | | STRIPPING TO COMPLY WITH FBC ACCESSIBILITY 502.3 | | | 4) PLEASE SHOW ACCESSIBLE PARKING SIGNAGE TO COMPLY | | | WITH FBC ACCESSIBILITY 502.6.1 | | | 5) PLEASE PROVIDE SIGNED AND SEALED LIGHT POLE DETAILS | | | (FOUNDATION AND ATTACHMENTS TO THE FOUNDATION ALSO SHOW | | | THE WIND DESIGN PARAMETERS USED) FROM AN ARCHITECT OR | | | ENGINEER TO COMPLY WITH WIND LOADS PER FBC 1609 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
N |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-05-31 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-05-31 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2022-05-31 13:51:09 | SEE PERMIT 20091234 FOR THE ELECTRICAL WORK ON THIS | | | PROJECT. JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2022-05-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-05-26 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-05-26 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2022-05-26 13:55:35 | NO ELECTRICAL WORK SHOWN??????? JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-08-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-08-21 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-08-21 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-06-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-06-29 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-06-29 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2020-06-29 10:05:28 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) ELECTRICAL PERMIT REQUIRED. | | | | | | 2) PAGE E-100 PROVE PROTECTION FOR SERVICE EQUIPMENT | | | SPACE PROVIDED IS ONLY 2' 110.26 PROVIDE WORKING | | | CLEARANCES AND PROTECTION OF EQUIPMENT. | | | | | | 3) PAGES E-701 AND E-002 ) NOTE #3 TO SECTION LOW | | | VOLTAGE ELECTRICAL POWER BOTH HAVE REFERENCES TO | | | VOLTAGE DROP, WHICH DO PREFER TO USE, PAGE E-002 | | | CONFORMS TO ENREGY CODE. | | | | | | 4) PAGE E-801 RISER DOES NOT SHOW WIRE SIZES FOR | | | SERVICE EQUIPMENT OTHER THAN GROUNDING. 215.5 | | | | | | 5) PAGE E-801 PROVIDE AIC RATING AND CALCULATION | | | REQUIRED PER 110.9, 10 | | | | | | PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | | | | 6) PAGE E-801 DRIP LOOP ON SERVICE WILL BE TO LOW TO | | | MEET THE REQUIREMENTS OF 230.23(B)(2) |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2022-05-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2022-05-09 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2020-10-02 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-10-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2020-10-02 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2020-08-24 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-08-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2020-08-24 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2020-06-25 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-06-25 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2020-06-25 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-06-25 12:09:06 | PLEASE ADDRESS BUILDING COMMENTS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-06-16 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-06-16 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-05-04 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2022-05-21 13:40:20 | BACKDATED, DIGITALLY PLANS UPLOADED WITH NO CHANGES | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-05-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-05-17 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-05-04 |
Time |
19:27 |
Sent To |
|
|
| Notes |
| 2022-05-17 10:01:58 | PROCESSED OUT AT APPLICANT'S REQUEST, NEEDS TO UPLOAD | | | DIGITALLY SIGNED PLANS | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-10-30 |
|
|
Cont ID |
|
| Sent By |
ccarvaja |
Date |
2020-10-29 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-29 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-09-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-09-18 |
Time |
06:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-08-05 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-08-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-08-03 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-06-08 |
Time |
09:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2022-05-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-23 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-23 |
Time |
14:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2022-05-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-10 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-10 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2022-05-10 10:42:18 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) ALL OF THE SIGNED AND SEALED DRAWINGS DO NOT SHOW AS | | | DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-10-09 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-09 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-09 |
Time |
14:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-08-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-24 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-24 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2020-08-24 08:27:46 | DRAWINGS LABELED "PAVING & DRAINAGE.PDF" IN PROJECTDOX | | | = SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL | | | SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE | | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG | | | WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON | | | FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW | | | REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected] | | | AND ASKING FOR THE FORM. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-06-24 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-06-24 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2020-06-24 12:51:31 | DRAWINGS NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED BY | | | THE ENGINEER OR ARCHITECT TO BE USED IN ELECTRONIC PLAN | | | REVIEW. | | | | | | FYI = ENGINEER CANNOT SELF-CERTIFY THE DIGITAL | | | SIGNATURE | | | 668.003(2) AND (3), F.S. | | | (2) A PROFESSIONAL ENGINEER UTILIZING A DIGITAL | | | SIGNATURE TO ELECTRONICALLY SIGN AND SEAL ENGINEERING | | | PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS SHALL HAVE | | | THEIR IDENTITY AUTHENTICATED BY A CERTIFICATION | | | AUTHORITY. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2022-06-15 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2022-06-15 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2022-06-15 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2022-06-15 14:50:52 | WILL REQUIRE SEPERATE LANDSCAPE AND IRRIGATION PLANS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2020-10-26 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2020-10-26 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2020-10-26 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2020-10-26 16:07:46 | PERMIT WILL NOT BE APPROVED BY ZONING UNITL THE | | | SUCCESFUL RELOCATION OF THE 316 GARDENIA STRUCTURE IS | | | COMPLETED. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2020-09-17 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2020-09-17 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2020-09-17 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2020-09-17 14:29:37 | 1. A SEPARATE LANDSCAPE, PAVING AND IRRIGATION PERMIT | | | WILL BE REQUIRED FOR THIS PROJECT. CLARIFICATION IS | | | NEEDED REGARDING THE TYPE OF PERMIT SUBMITTED | | | (ELECTRIC) VS DESCRIPTION LISTED AS PAVING. | | | 3. THE EXPANSION OF THE SURFACE PARKING LOT WILL NOT BE | | | APPROVED BY ZONING UNTIL THE SUCCESFUL RELOCATION OF | | | THE EXISTING STRUCTURE LOCATED AT 316 GARDENIA. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-07-30 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2020-07-30 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2020-07-30 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2020-07-30 15:18:28 | 1. PLEASE INCLUDE A SITE PLAN DETAILING THE SIZE OF | | | EACH OF THE SPACES, DRIVE AISLES AND STRIPING DETAIL. | | | 2. PLEASE PROVIDE INFORMATION THE PARKING LOT EXPANSION | | | COMPLIES WITH THE REQUIRED FRONT SETBACKS. | | | 3. A SEPARATE LANDSCAPE PERMIT SHALL BE SUBMITTED. | | | 4. THE SURFACE PARKING LOT EXPANSION IS CONDITIONAL TO | | | THE SUCCESFUL RELOCATION OF THE EXISTING STRUCTURE | | | LOCATED AT 316 GARDENIA. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439 |
|
|