Plan Review Details - Permit 20060197
Plan Review Stops For Permit 20060197
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2020-06-23 Cont ID  
Sent By jwitmer Date 2020-06-23 Time 14:32 Rev Time 0.00
Received By jwitmer Date 2020-06-23 Time 14:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-11-04 Cont ID  
Sent By jleahy Date 2020-11-04 Time 13:39 Rev Time 0.00
Received By jleahy Date 2020-11-04 Time 13:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-08-26 Cont ID  
Sent By jleahy Date 2020-08-26 Time 16:44 Rev Time 0.00
Received By jleahy Date 2020-08-26 Time 16:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-06-25 Cont ID  
Sent By jleahy Date 2020-06-25 Time 09:22 Rev Time 0.00
Received By jpearson Date 2020-06-25 Time 09:19 Sent To  
Notes
2020-06-25 09:22:26CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE DETAIL OF ELECTRICAL DISCONNECT REQUIRED PER
 NEC 600.6(A)(1).
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-11-17 Cont ID  
Sent By ccarvaja Date 2020-11-17 Time 16:22 Rev Time 0.00
Received By ccarvaja Date 2020-10-30 Time 10:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-15 Cont ID  
Sent By shill Date 2020-09-15 Time 14:42 Rev Time 0.00
Received By shill Date 2020-08-20 Time 15:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-29 Cont ID  
Sent By cpuell Date 2020-06-29 Time 11:55 Rev Time 0.00
Received By cpuell Date 2020-06-22 Time 15:33 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-11-04 Cont ID  
Sent By jleahy Date 2020-11-04 Time 13:39 Rev Time 0.00
Received By jleahy Date 2020-11-04 Time 13:39 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-08-26 Cont ID  
Sent By jleahy Date 2020-08-26 Time 16:44 Rev Time 0.00
Received By jleahy Date 2020-08-26 Time 16:44 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-06-25 Cont ID  
Sent By jpearson Date 2020-06-25 Time 09:21 Rev Time 0.00
Received By jpearson Date 2020-06-25 Time 09:21 Sent To  
Notes
2020-06-25 09:21:47PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 IS REQUIRED TO BE SIGNED (AND SEALED FOR DESIGN
 PROFESSIONALS) BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED OR SIGNED/SEALED
 PAPER SET MAY BE SUPPLIED TO THE BUILDING DEPARTMENT
 WHEN ALL TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481

Review Stop Z ZONING
Rev No 3 Status P Date 2020-11-17 Cont ID  
Sent By elevesqu Date 2020-11-18 Time 12:13 Rev Time 0.00
Received By elevesqu Date 2020-11-12 Time 12:13 Sent To  
Notes
2020-11-17 13:29:00OLD PLANS WERE REMOVED, CHANGED TO APPROVE STATUS
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]
 561 822 1426
2020-11-12 12:13:33NOT CLEAR WHICH PERMIT IS FOR WHICH GARAGE. PLEASE ONLY
 SUBMIT ELEVATIONS FOR ASSOCIATED PERMIT
  
 PLEASE REMOVE ALL OF THE OLD PLANS THAT STILL SHOW THE
 OLD VERSION OF THE SIGN
  
 PLEASE ONLY UPLOAD PLANS UNDER THE "DRAWINGS" FOLDER
 NOT THE "SUPPORTING DOCS" FOLDER FOR CLARIFICATION
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 561 822 1426
 [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2020-09-02 Cont ID  
Sent By elevesqu Date 2020-09-02 Time 13:18 Rev Time 0.00
Received By elevesqu Date 2020-09-02 Time 13:18 Sent To  
Notes
2020-09-02 13:18:32SIGN EXCEEDS MAXIMUM HEIGHT FOR SIGN BAND WITHIN
 DOWNTOWN MASTER PLAN (DMP) AREA -
 CANNOT EXCEED 36" IN HEIGHT
  
 WIDTH CAN BE 60% OF FACADE WIDTH
  
 NOT CLEAR DIFFERENCE BETWEEN THIS PERMIT AND PERMIT
 20060198 - PLEASE CLARIFY
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 561 822 1426
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2020-06-29 Cont ID  
Sent By aaponte Date 2020-06-29 Time 10:12 Rev Time 0.00
Received By elevesqu Date 2020-06-29 Time 10:12 Sent To  
Notes
2020-06-29 10:13:22PLEASE PROVIDE SITE PLAN AND ELEVATION INDICATING
 PROPOSED LOCATION OF SIGN - IS THIS WALL MOUNTED OR
 FREESTANDING?
 PLEASE INDICATE WHICH PARKING GARAGE THIS WILL BE IN
 AND WHERE IN PARKING GARAGE (JUST ONE OR MULTIPLE
 ENTRANCES?)
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 561 822 1426
 [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved