| Plan Review Stops For Permit 20060186 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-08-19 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-08-19 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2020-08-19 10:49:17 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20060186 | | | ADD: 2405 N AUSTRAALIAN AVE. / DOG PARK | | | CONT: AHS CONSTRUCTION | | | TEL: 305-255-5527 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 4TH REVIEW | | | DATE:WED. AUGUST 19TH/ 2020 | | | ACTION: BUILDING PROVISO/ DEFERRED SUBMITTAL | | | | | | 1) THE ENGINEER OF RECORD ALEXANDER ROCHELL HAS STATED | | | THAT SHEET S-1 THE GAZEBO SHOWN IS TO BE DESIGNED BY A | | | DELEGATE ENGINEER AS PART OF A SHOP DRAWING SUBMITTAL | | | BY MEADOW VIEW WOODWORKING. THIS WILLBE ISSUED AS A | | | PROVISO, DEFERRED SUBMITTAL BY A DELEGATE ENGINEER. | | | SHEET A1 BY ARCHITECT LEOPOLDO BELLONHAS PROVIDED THE | | | DESIGN CRITERIA TO USE AS A GUIDE FOR DELEGATE | | | ENGINEERING. | | | JIM WITMER BUILDING PLAN REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2020-08-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-08-10 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-08-10 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2020-08-10 08:49:40 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20060186 | | | ADD: 2405 N AUSTRAALIAN AVE. / DOG PARK | | | CONT: AHS CONSTRUCTION | | | TEL: 305-255-5527 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 3RD REVIEW | | | DATE: MON. AUGUST 10TH/ 2020 | | | ACTION: DENIED | | | | | | 1-3) COMPLIED. | | | | | | 4A) SEMI-COMPLIED. THE ENGINEER OF RECORD ALEXANDER | | | ROCHELL HAS STATED THAT SHEET S-1 THE GAZEBO SHOWN IS | | | TO BE DESIGNED BY A DELEGATE ENGINEER AS PART OF A SHOP | | | DRAWING SUBMITTAL BY MEADOW VIEW WOODWORKING. THIS | | | COULD BE ISSUED AS A PROVISO, DEFERRED SUBMITTAL BY A | | | DELEGATE ENGINEER. SHEET A1 ON VERSIONS I & 2 THE | | | ARCHITECT LEOPOLDO BELLON DID GIVE DESIGN CRITERIA TO | | | USE AS A GUIDE FOR DELEGATE ENGINEERING TO USE, BUT ON | | | VERSION 3 SHEET A1 THAT IS NOW ALL GONE NO DESIGN | | | CRITERIA WAS GIVEN. A NEW DETAIL SUBMITTED FOR FENCING | | | IS IN ITS PLACE. | | | | | | 4B) COMPLIED. THE PROPOSED STRUCTURE IS NOT IN A FLOOD | | | ZONE. | | | | | | 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-07-15 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-07-15 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2020-07-15 08:43:43 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | 2ND BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, THE FOLLOWING INFORMATION (AS NOTED FROM | | | THE FIRST REVIEW) IS MISSING: | | | | | | 1) OK | | | 2) FAILED, FBC A 208.2, THE PLAN DOES NOT SHOW ANY OF | | | THE ACCESSIBLE PARKING REQUIREMENTS. | | | 3) OK | | | 4) FAILED, FBC B 107.3.5, THE STRUCTURAL PLANS DO NOT | | | SHOW THE REQUIRED DETAILS/SPECIFICATIONS FOR FLOORS, | | | WALLS AND ROOFS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-06-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-06-18 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-06-18 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2020-06-18 12:12:44 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20060186 | | | ADD: 2405 N AUSTRAALIAN AVE. / DOG PARK | | | CONT: AHS CONSTRUCTION | | | TEL: 305-255-5527 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURS. JUNE 18TH/ 2020 | | | ACTION: DENIED | | | | | | 1) SHEET A-1 SCALE IS 1/16 INCH, SMALLER THAN THE | | | BUILDING DEPARTMENT STANDARD. 107.2.1.3. QUALITY OF | | | PLANS. BUILDING PLANS SHALL BE DRAWN TO A 1/8TH INCH | | | SCALE ON SUBSTANTIAL PAPER OR OTHER ACCEPTABLE MEDIUM. | | | THE BUILDING OFFICIAL MAY ESTABLISH THROUGH DEPARTMENT | | | POLICY OTHER STANDARDS FOR THE PLANS AND SPECIFICATIONS | | | IN ORDER TO PROVIDE CONFORMITY TO ITS RECORD RETENTION | | | PROGRAM. THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM | | | SIZE, SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED | | | TO RECORD MANAGEMENT. ELECTRONIC MEDIA MUST BE | | | COMPATIBLE WITH THE ARCHIVE REQUIREMENTS OF FLORIDA | | | STATUTES. | | | | | | 2) SHEET A-1 SHOWS A PARKING LOT, IS THIS AN EXISTING | | | PARKING LOT OR NEW? IS THE PARKING AREA SHOWN CITY | | | PROPERTY? THE PLAN DOES NOT SHOW ANY ACCESSIBLE | | | PARKING, SHOW COMPLIANCE WITH THE 2017 | | | FBC-ACCESSIBILITY CODE SECTION 208.2 MINIMUM NUMBER AND | | | TABLE 208.2. | | | | | | 3) SHEET A-1 SHOWS IN THE PARKING AREA THE PARKING | | | SPACES ARE SINGLE STRIPED, NOT THE DOUBLE STRIPE | | | REQUIRED BY THE MUNI CODE, ALSO SEE THE2017 FBC- | | | ACCESSIBILITY CODE SECTION: ACCESSIBLE PARKING SPACE / | | | STALL PAINTING. | | | 2017 ACCESSIBILITY CODE SECTION 502.2 VEHICLE SPACES. | | | EACH PARKING SPACE MUST BE AT LEAST 12 FEET WIDE, SHALL | | | BE MARKED TO DEFINE THE WIDTH, AND SHALL HAVE AN | | | ADJACENT ACCESS AISLE COMPLYING WITH 502.3. | | | ADVISORY 502.3.3MARKING THE METHOD AND MARKING OF COLOR | | | OF MARKING ARE NOT SPECIFIED BY THESE REQUIREMENTS BUT | | | MAY BE ADDRESSED BY STATE OR LOCAL LAWS OR REGULATIONS. | | | WEST PALM MUNI-CODE ARTICLE XV PARKING DETAIL, 94-485 | | | ILLUSTRATES WITH MEASUREMENTS FOR DOUBLE STRIPE STALL | | | PAINTING. | | | | | | 4) SHEETS S1, S2 & S3 DO NOT HAVE ANY DRAWINGS, DETAILS | | | FOR THE GAZEBO. SHEET A-1 DOES GIVE WIND DESIGN | | | CRITERIA AND HAS A STATEMENT THAT THE A1 SHEET IS TO | | | PROVIDE MEADOW VIEW WOODWORKING IN CONSTRUCTION OF | | | GAZEBO. THERE WERE NO STRUCTURAL DRAWINGS SUBMITTED | | | WHERE ANYONE COULD BUILD THE GAZEBO. | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS. | | | 107.3.5.1.1. BUILDING. | | | FLOOR PLAN, | | | STRUCTURAL REQUIREMENTS SHALL INCLUDE: | | | FLOOR SYSTEMS (SHEET S-3) | | | WALL FRAMING, POST AND OR COLUMNS | | | ROOF SYSTEMS ROOF FRAMING, ANCHORS, SHEATHING/ DECKING, | | | AND ROOFING MATERIALS | | | THIS STRUCTURE MAYBE IN A FLOOD ZONE THE CIVIL DRAWING | | | SUBMITTED DIDN?T INDICATE THE FLOOD ZONE THE GAZEBO IS | | | IN? 2017 FBC-B 1612.1. | | | | | | 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED | | | DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE | | | MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS | | | AND INFORMATION LACKING UNDER THE PRIOR REVIEW. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2020-08-10 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-08-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2020-08-10 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-07-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2020-07-28 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-07-28 11:40:08 | PLEASE ADDRESS BUILDING COMMENTS. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2020-06-25 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-06-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2020-06-25 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-06-25 09:15:57 | PLEASE ADDRESS BUILDING COMMENTS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-07-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-07-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-07-14 |
Time |
11:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2020-07-01 |
|
|
Cont ID |
|
| Sent By |
bwoods |
Date |
2020-07-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
bwoods |
Date |
2020-07-01 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-07-01 09:33:30 | PERMIT #20060186 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | ADDRESS BUILDING DEPARTMENT COMMENTS | | | | | | BRITTANY WOODS | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4754 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
2020-08-19 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
2020-08-12 |
Time |
13:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-08-11 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
2020-08-11 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
2020-08-07 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-07-29 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
2020-07-29 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
2020-07-13 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2020-07-29 11:17:54 | LAST REVIEWER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-07-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-07-06 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-06-04 |
Time |
13:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-08-19 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2020-08-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-08-10 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-08-10 08:54:28 | THE STRUCTURAL SHEETS S1, S2, S3 & S4 APPEAR TO HAVE | | | DIGITAL SIGNATURES BUT THE PROCESS WAS NOT COMPLETED. | | | WHEN YOU OPEN THE SIGNATURE FILES THEY ARE BLANK. NO | | | SIGNATURE ,NO DATE AND NO 3RD PARTY VERIFIYING THE | | | SIGNATURE. | | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | | ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-07-15 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-07-15 |
Time |
06:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-07-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-07-06 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-07-06 |
Time |
14:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
2020-08-19 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
2020-08-19 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2020-08-19 13:10:48 | SEPARATE PERMITS SUBMITTED AND PUBLIC ACCESS EASEMENT | | | UNDER REVIEW. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2020-08-11 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
2020-08-11 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
2020-08-11 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2020-08-11 13:01:46 | RECEIVED EMAIL FROM KRYSTAL THAT WRONG PLANS WERE | | | SUBMITTED. NEED SEPARATE LANDSCAPE PERMIT SUBMITTED TO | | | PASS ZONING. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2020-07-29 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
2020-07-29 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
2020-07-29 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2020-07-29 11:19:02 | | | | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 2405 N AUSTRALIAN AVE PERMIT 20060186 | | | JULY 29, 2020 | | | THERE ARE DIFFERENT REVIEW SEQUENCES AND INSPECTIONS | | | FOR EACH PERMIT, SO WE ARE TRYING TO GROUP TOGETHER | | | LIKE ITEMS. FEES ARE DUE TO DIFFERENT REVIEWING AND | | | INSPECTING FUNCTIONS, SO THE ITEMS ON EACH PERMIT | | | SHOULD HAVE THE CORRESPONDING VALUE ASSIGNED TO THAT | | | PERMIT. | | | 1. GAZEBO AND FLATWORK (SIDEWALKS) CAN REMAIN UNDER THE | | | CURRENT PERMIT. | | | ? ENGINEERING REVIEW WILL BE CONDUCTED ON THIS PERMIT, | | | SHEET C1.0 FOR GRADING AND DRAINAGE FOR REQUIREMENTS | | | AND WILL SPECIFY IF A SEPARATE PERMITTING IS REQUIRED. | | | ? ADDRESS BUILDING REVIEW COMMENTS. | | | ? CHANGE THE BIKE RACKS TO CITY APPROVED MODELS AND | | | SPACING | | | ? A PUBLIC ACCESS EASEMENT MUST BE SUBMITTED FOR REVIEW | | | FOR THE SIDEWALK ON THE NORTH SIDE. ONCE APPROVED, IT | | | MUST BE RECORDED. | | | 2. SUBMIT A SEPARATE ELECTRIC SUB PERMIT IF ANY | | | LIGHTING OR ELECTRICAL IS TO BE PROPOSED. | | | 3. COMPLETED | | | 4. SUBMIT A SEPARATE PERMIT FOR THE IRRIGATION. | | | 5. SUBMIT A SEPARATE LANDSCAPE PERMIT AND MAKE THE | | | FOLLOWING CORRECTIONS TO THE LANDSCAPE PLAN: | | | ? PROVIDE THE CALCULATIONS FOR REQUIRED TREES AND | | | FLOWERING TREES PER SECTION 94-442(C)(2)B. | | | ? PROVIDE A TREE DISPOSITION PLAN SHOWING TREE REMOVED, | | | CALCULATE CANOPY SQUARE FOOTAGE AND SHOW MITIGATION | | | CANOPY SQUARE FOOTAGE PROVIDED THROUGH LANDSCAPE PLAN. | | | SUBMIT A TREE ALTERATION PERMIT. | | | ? PROVIDE THE FLORIDA FRIENDLY LANDSCAPE CHART SHOWING | | | 50 POINTS ACHIEVED PER SECTION 94-442(G). | | | ? SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT SPECIES. | | | A MINIMUM OF 60 PERCENT OF PLANT MATERIAL ADDED SHALL | | | BE FLORIDA NATIVE OR DROUGHT TOLERANT SPECIES SELECTED | | | FROM THE CITY LIST OR THE LIST OF SPECIES IN THE MOST | | | RECENT EDITION OF SOUTH FLORIDA WATER MANAGEMENT | | | DISTRICT WATERWISE SOUTH FLORIDA LANDSCAPES. PROVIDE | | | THE ACTUAL PERCENTAGE CALCULATED FROM THE PLANT LIST | | | FOR THE PROJECT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-06-25 |
|
|
Cont ID |
|
| Sent By |
avann |
Date |
2020-06-25 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
2020-06-25 |
Time |
16:50 |
Sent To |
FIRE |
|
| Notes |
| 2020-06-25 16:51:24 | | | | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 2405 N AUSTRALIAN AVE PERMIT 20060186 | | | JUNE 25, 2020 | | | THERE ARE DIFFERENT REVIEW SEQUENCES AND INSPECTIONS | | | FOR EACH PERMIT, SO WE ARE TRYING TO GROUP TOGETHER | | | LIKE ITEMS. FEES ARE DUE TO DIFFERENT REVIEWING AND | | | INSPECTING FUNCTIONS, SO THE ITEMS ON EACH PERMIT | | | SHOULD HAVE THE CORRESPONDING VALUE ASSIGNED TO THAT | | | PERMIT. | | | 1. GAZEBO AND FLATWORK (SIDEWALKS) CAN REMAIN UNDER THE | | | CURRENT PERMIT. | | | ? ENGINEERING REVIEW WILL BE CONDUCTED ON THIS PERMIT, | | | SHEET C1.0 FOR GRADING AND DRAINAGE FOR REQUIREMENTS | | | AND WILL SPECIFY IF A SEPARATE PERMITTING IS REQUIRED. | | | ? ADDRESS BUILDING REVIEW COMMENTS. | | | ? CHANGE THE BIKE RACKS TO CITY APPROVED MODELS AND | | | SPACING | | | ? A PUBLIC ACCESS EASEMENT MUST BE SUBMITTED FOR REVIEW | | | FOR THE SIDEWALK ON THE NORTH SIDE. ONCE APPROVED, IT | | | MUST BE RECORDED. | | | 2. SUBMIT A SEPARATE ELECTRIC SUB PERMIT IF ANY | | | LIGHTING OR ELECTRICAL IS TO BE PROPOSED. | | | 3. A SEPARATE PERMIT IS TO BE SUBMITTED FOR THE WALL | | | AND FENCES. | | | 4. SUBMIT A SEPARATE PERMIT FOR THE IRRIGATION. | | | 5. SUBMIT A SEPARATE LANDSCAPE PERMIT AND MAKE THE | | | FOLLOWING CORRECTIONS TO THE LANDSCAPE PLAN: | | | ? PROVIDE THE CALCULATIONS FOR REQUIRED TREES AND | | | FLOWERING TREES PER SECTION 94-442(C)(2)B. | | | ? PROVIDE A TREE DISPOSITION PLAN SHOWING TREE REMOVED, | | | CALCULATE CANOPY SQUARE FOOTAGE AND SHOW MITIGATION | | | CANOPY SQUARE FOOTAGE PROVIDED THROUGH LANDSCAPE PLAN. | | | SUBMIT A TREE ALTERATION PERMIT. | | | ? PROVIDE THE FLORIDA FRIENDLY LANDSCAPE CHART SHOWING | | | 50 POINTS ACHIEVED PER SECTION 94-442(G). | | | ? SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT SPECIES. | | | A MINIMUM OF 60 PERCENT OF PLANT MATERIAL ADDED SHALL | | | BE FLORIDA NATIVE OR DROUGHT TOLERANT SPECIES SELECTED | | | FROM THE CITY LIST OR THE LIST OF SPECIES IN THE MOST | | | RECENT EDITION OF SOUTH FLORIDA WATER MANAGEMENT | | | DISTRICT WATERWISE SOUTH FLORIDA LANDSCAPES. PROVIDE | | | THE ACTUAL PERCENTAGE CALCULATED FROM THE PLANT LIST | | | FOR THE PROJECT | | | | | | |
|
|