| Plan Review Stops For Permit 20060062 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-07-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-07-24 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-24 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2020-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-06-24 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-06-24 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-07-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-24 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-24 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-06-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-06-30 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-06-30 |
Time |
14:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-07-23 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-07-23 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-07-23 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2020-07-23 12:51:19 | 20060062 8813 LAKES BLVD | | | | | | | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF WORK TO BE PERFOMED PER WPB FBC 107.2.1. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC FG | | | 301.3 AND FBC RES G2404.3 | | | A SEPARATE PERMIT AND PLANS ARE REQUIRED FOR THE GAS | | | INSTALLATION OR MODIFICATION OF THE SYSTEM. | | | PLEASE NOTE THAT THERE IS A PRINTED PERMIT APPLICATION | | | 20030186 ATTACHED TO THIS ADDRESS, BUT NO PLANS HAVE | | | BEEN SUBMITTED. | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-07-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-24 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-08 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-07-06 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-07-06 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-06-11 |
Time |
11:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-07-23 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-07-23 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-07-23 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2020-07-23 13:25:13 | 20060062 8813 LAKES BLVD | | | | | | | | | PLUMBING COMMENTS: APPROVED | | | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | ON 6/11/20, AN EMAIL WAS SENT TO THE PERMIT LIBRARIAN | | | BY THE APPLICANT ASKING THAT THE JXI GAS HEATER BE | | | REMOVED FROM THE FOLDER. JANDY LEGACY MODEL ZODIAC LRZ | | | IS THE CORRECT POOL HEATER | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 20060062 8813 LAKES BLVD | | | | | | PLEASE NOTE: | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF WORK TO BE PERFOMED PER WPB FBC 107.2.1. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC FG | | | 301.3 AND FBC RES G2404.3 | | | A SEPARATE PERMIT AND PLANS ARE REQUIRED FOR THE GAS | | | INSTALLATION OR MODIFICATION OF THE SYSTEM. | | | PLEASE NOTE THAT THERE IS A PRINTED PERMIT APPLICATION | | | 20030186 ATTACHED TO THIS ADDRESS, BUT NO PLANS HAVE | | | BEEN SUBMITTED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-07-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-06 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-06 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2020-07-06 08:37:33 | PLUMBING 1ST REVIEW COMMENTS. 20060062 | | | 1) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE | | | MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM | | | ITS PUMP CURVE AND THE SIMPLIFIED TOTAL DYNAMIC HEAD | | | CALCULATION IS NO LONGER ALLOWED TO BE USED IN | | | DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC | | | 7 - 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION | | | ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT | | | REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED | | | THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET | | | FITTING ASSEMBLY (DRAIN COVER).THE TDH CALCULATIONS | | | MUST INCLUDE ALL OF THE SYSTEM COMPONENTS INCLUDING | | | SUCTION AND RETURN PIPING, FITTINGS, VALVES, HEATER, | | | FILTER, AND CHLORINATOR. ALL SYSTEM COMPONENTS EXCEPT | | | THE PUMP. | | | | | | 2) SUBMIT TWO LEGIBLE COPIES OF THE POOL PUMP CURVE. | | | IDENTIFY ON THE PUMP CURVE WHICH CURVE KEY IS SPECIFIC | | | TO THE PUMP BEING INSTALLED ON THIS POOL. THIS IS | | | NEEDED TO CONFIRM THE MAXIMUM SYSTEM FLOW FROM THE TDH | | | CALCULATIONS. ANSI/APSP/ICC 7 - 2013 SECS. 4.4.9, | | | 4.4.9.1 | | | | | | 3) GENERAL SPEC FOR EQUIPMENT WAS SUBMITTED. INDICATE | | | WHICH MODEL FOR EACH PIECE OF EQUIPMENT IS BEING USE ON | | | THIS PROJECT. | | | | | | 4) PLEASE REMOVE THE COMMENT THAT AIR TEST IS AN | | | APPROVED MEANS OF TEST. AIR TESTING IS PROHIBITED ON | | | PVC PIPING. FBC-PLB 312.1 | | | | | | 5) WILL THERE BE A AUTOFILL ON THIS POOL? FBC 107.2.1 | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | (CAP GOVERNMENT) | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-07-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-07-24 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-24 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-06-24 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-06-24 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-07-02 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2020-07-02 |
Time |
|
Sent To |
I |
|
| Notes |
|
|