Plan Review Details - Permit 20060031
Plan Review Stops For Permit 20060031
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2020-07-20 Cont ID  
Sent By jleahy Date 2020-07-20 Time 09:05 Rev Time 0.00
Received By jleahy Date 2020-07-20 Time 09:05 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2020-07-09 Cont ID  
Sent By jwitmer Date 2020-07-09 Time 10:27 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-06-17 Cont ID  
Sent By jwitmer Date 2020-06-17 Time 10:03 Rev Time 0.00
Received By jwitmer Date 2020-06-17 Time 08:02 Sent To  
Notes
2020-06-17 10:03:49ASBESTOS COMMERCIAL.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
 19120504
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2020-10-15 Cont ID  
Sent By jwitmer Date 2020-10-15 Time 07:54 Rev Time 0.00
Received By jwitmer Date 2020-10-15 Time 07:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-07-21 Cont ID  
Sent By jwitmer Date 2020-07-21 Time 14:30 Rev Time 0.00
Received By jwitmer Date 2020-07-21 Time 13:45 Sent To  
Notes
2020-07-21 11:35:19BUILDING PASSED 7/21/2020. JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-07-09 Cont ID  
Sent By jwitmer Date 2020-07-09 Time 10:26 Rev Time 0.00
Received By jwitmer Date 2020-07-09 Time 08:24 Sent To  
Notes
2020-07-09 08:24:332017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20060031
 ADD: 314 FLAMINGO DRIVE
 CONT: CASA BUENA CONSTRUCTION/ PEDRO FURTADO
 TEL: 818-620-7860
 E-MAIL: DAMONMONTYDMAC.COM
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: THURS. JULY 09TH/ 2020
 ACTION: DENIED
  
 *****************NOTICE********************
 4X FEE / NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B)
 WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS?
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
  
  
  
 1A) 2ND REQUEST. THERE IS STILL A OPEN PERMIT 19080808
 FROM THE SAME CONTRACTOR FOR A LIVE/ WORK LOFT UNIT,
 PLEASE CONCEAL PERMIT.
  
 1B) 2ND REQUEST. WHEN YOU PUT THE ADDRESS IN 314
 FLAMINGO DRIVE INTO THE INTERNET THE RESULTS ARE FOR
 JAMES SWOPE FINE ARTS CONSERVATION WITH OFFICE HOURS
 AND WHAT APPEARS POSSIBLY VIEWINGS, CLASSES AND OR
 AUCTIONS SINCE THERE IS ALSO TICKET SALES. WE WILL NEED
 A LETTER FROM THE OWNER WHAT THE END INTENT FOR THIS
 BUILDING. THE NEW OWNERS HIBISCUSPB LLC WILL NEED TO
 INDICATE THE USE OF THIS PROPERTY.
  
 1C) 2ND REQUEST. THE SHEET 002A INDICATES A LEVEL 2
 ALTERATION TO A SINGLE FAMILY HOUSE. THE PALM BCH
 COUNTY HAS THE LAST KNOWN USE AS A WAREHOUSE. THIS
 WOULD BE CONSIDERED A CHANGE IN OCCUPANCY AND THE PLANS
 DEVELOPED UNDER THE 2017 FBC-EXISTING BUILDING AND THE
 2017 RESIDENTIAL CODE IF THE USE IS TO BE STRICTLY USED
 FOR A SINGLE FAMILY DWELLING.
  
 1D) COMPLIED.
  
 2) 2ND REQUEST. THE DESIGNER OF RECORD HAS NOT
 DISCLOSED UNDER WHAT BUILDING CODE THESE PLANS WERE
 DEVELOPED. STATEWIDE THE 2017 FAMILY OF FLORIDA
 BUILDING CODES WERE ADOPTED ON DEC. 31/ 2017. UPDATE
 PLANS.
  
 3) 2ND REQUEST. THE DESIGNER OF RECORD HAS NOT
 DISCLOSED UNDER THE 2017 FLORIDA EXISTING BUILDING CODE
 WHAT METHOD THE PLANS WERE DEVELOPED. FOR THIS REVIEW
 THE REVIEWER WILL BE USING BOTH THE 2017 FBC-B AND THE
 2017 EXIST. BUILDING CODE CHAPTER 10 CHANGE OF
 OCCUPANCY SECTION 1001.2.2. CHANGE OF OCCUPANCY
 CLASSIFICATION OR GROUP. WHERE THE OCCUPANCY
 CLASSIFICATION OF A BUILDING CHANGES, THE PROVISIONS OF
 SECTIONS 1002 THROUGH 1012 SHALL APPLY. THIS INCLUDES A
 CHANGE OF OCCUPANCY CLASSIFICATION AND A CHANGE TO
 ANOTHER GROUP WITHIN AN OCCUPANCY CLASSIFICATION.
  
 THIS BUILDING WE COULD NOT FIND A BUSINESS TAX RECEIPT
 / BUT PALM BEACH COUNTY PROPERTY APPRAISERS HAS THE
 OCCUPANCY TYPE LISTED AS WAREHOUSE/ STORAGE. THAT IS
 WHY WE ARE LISTING THIS REVIEW AS A CHANGE IN
 OCCUPANCY/ CHANGE IN USE.
  
 4-5) COMPLIED.
  
 6) 2ND REQUEST. SHEET A.1.1 SHOWS A NEW STOREFRONT
 DOORS AND GARAGE DOOR PLEASE PROVIDE COMPLIANCE WITH:
 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS ,OVERHEAD GARAGE DOOR
 (B) WINDOWS AND MULLIONS ( SIDELIGHTS)
  
 NOA-17-0630.11 GCI HEAVY DUTY MULLIONS ONLY THE FRONT
 PAGE OF REPORT SUBMITTED.
  
 NOA-17-1018.08 SENTINEL 110 SINGLE HUNG WINDOWS ONLY
 THE FRONT PAGE OF REPORT. EXPIRES: 09-22-2020.
  
 NOA-17-1114-01 ENTRANCE DOORS / TRANSOM ONLY THE FRONT
 PAGE OF REPORT SUBMITTED.
 NOA- 17-1114-02 SS-3500 STOREFRONT ONLY THE FRONT PAGE
 OF REPORT SUBMITTED.
 NOA- 18-1217.05 GARAGE DOOR- FULL REPORT SUBMITTED. OK
  
 7) 2ND REQUEST. IDENTIFY GLAZING/ MULLIONS. PLEASE
 IDENTIFY ON THE PRODUCT APPROVAL BEFORE SUBMITTING TO
 DESIGNER OF RECORD AND BEFORE SUBMISSION TO THE
 BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING,
 PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF
 GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED OR
 REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND
 ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2017 FBC-B
 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE
 INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURERS
 INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE
 PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED
 BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS.
  
 8) SEMI- COMPLIED NO TECHNICAL SHEETS FROM THE NOA
 SUBMITTED. W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE
 PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE
 ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING
 ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC..
  
 9) NOT APPLICABLE.
 .
  
 10) 2ND REQUEST. SHEET S01 PROVIDES THE WIND DESIGN
 CRITERIA. BUT THE NEGATIVE PRESSURES ARE ABOUT 2.0 PSF
 LOW FOR EXPOSURE C. THE MEAN ROOF HEIGHT IS NOT GIVEN,
 NEGATIVE PRESSURES ARE TO BE TAKEN AT THE ROOF LINE.
 2017 FBC-B 1603.1.4 WIND DESIGN DATA. WIND EXPOSURE.
 APPLICABLE WIND DIRECTION IF MORE THAN ONE WIND
 EXPOSURE IS UTILIZED. TABLE 1609.7.2. HEIGHT AND
 EXPOSURE. TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT
 & EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING. 1609.3.1 WIND SPEED CONVERSION VULT TO VASD.
  
 11) COMPLIED. ASBESTOS
  
 12) IN REVIEW P. B. COUNTY. IMPACT FEES - DIGITAL
 SUBMITTALS: PLANS WILL BE REVIEWED BY THE PBC IMPACT
 FEE OFFICE DIGITALLY VIA PROJECT DOX UPON NOTIFICATION
 BY THIS OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE
 NEAREST FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT
 FEE OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE
 MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT
 AND NAME THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE.
 THE FORM CAN BE FOUND AT:
 HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRAT
 ION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
  
 13). A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717 / FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-17 Cont ID  
Sent By jwitmer Date 2020-06-17 Time 10:01 Rev Time 0.00
Received By jwitmer Date 2020-06-17 Time 08:02 Sent To  
Notes
2020-06-17 10:01:132017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20060031
 ADD: 314 FLAMINGO DRIVE
 CONT: CASA BUENA CONSTRUCTION/ PEDRO FURTADO
 TEL: 818-620-7860
 E-MAIL: DAMONMONTYDMAC.COM
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. JUNE 17/2020
 ACTION: DENIED
  
 1A) THERE IS STILL A OPEN PERMIT 19080808 FROM THE SAME
 CONTRACTOR FOR A LIVE/ WORK LOFT UNIT.
 1B) WHEN YOU PUT THE ADDRESS IN 314 FLAMINGO DRIVE INTO
 THE INTERNET THE RESULTS ARE FOR JAMES SWOPE FINE ARTS
 CONSERVATION WITH OFFICE HOURS AND WHAT APPEARS
 POSSIBLY VIEWINGS, CLASSES AND OR AUCTIONS SINCE THERE
 IS ALSO TICKET SALES. WE WILL NEED A LETTER FROM THE
 OWNER WHAT THE END INTENT FOR THIS BUILDING.
 1C) THE SHEET 002A INDICATES A LEVEL 2 ALTERATION TO A
 SINGLE FAMILY HOUSE. THE PALM BCH COUNTY HAS THE LAST
 KNOWN USE AS A WAREHOUSE. THIS WOULD BE CONSIDERED A
 CHANGE IN OCCUPANCY AND THE PLANS DEVELOPED UNDER THE
 2017 FBC-EXISTING BUILDING AND THE 2017 RESIDENTIAL
 CODE IF THE USE IS TO BE STRICTLY USED FOR A SINGLE
 FAMILY DWELLING.
 1D) SHEET A1.01 MISSING INFORMATION. 2017 WEST PALM
 BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER
 1, ADMINISTRATIVE CODE, 107.3.5 MINIMUM PLAN REVIEW
 CRITERIA FOR BUILDINGS.
 107.3.5.1 COMMERCIAL BUILDINGS:
 107.3.5.1.1 BUILDING
 UNDER WHICH BUILDING CODE WERE THE PLANS DEVELOPED
 OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS
 SHALL BE DETERMINED IN CHAPTER 3 & 4 FBC-B
 MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED, NO
 SQ. FOOTAGE OF OCCUPANCIES ON PLANS,
 RATING OF FIRE BARRIER ASSEMBLIES, VERTICAL AND
 HORIZONTAL
 BUILDING FIRE SPRINKLERED OR NOT, FIRE SPRINKLER PLANS
 OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE:
 OCCUPANCY LOAD
 GROSS
 NET
 MEANS OF EGRESS
 EXIT ACCESS
 EXIT
 EXIT DISCHARGE
 STAIRS CONSTRUCTION/GEOMETRY AND PROTECTION
 DOORS
 EMERGENCY LIGHTING AND EXIT SIGNS
 ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE FOLLOWING:
 SITE REQUIREMENTS/ ACCESSIBLE ROUTE
 TOILET AND BATHING FACILITIES/ KITCHENETTE
 DRINKING FOUNTAINS
 2) THE DESIGNER OF RECORD HAS NOT DISCLOSED UNDER WHAT
 BUILDING CODE THESE PLANS WERE DEVELOPED. STATEWIDE THE
 2017 FAMILY OF FLORIDA BUILDING CODES WERE ADOPTED ON
 DEC. 31/ 2017. UPDATE PLANS.
  
 3) THE DESIGNER OF RECORD HAS NOT DISCLOSED UNDER THE
 2017 FLORIDA EXISTING BUILDING CODE WHAT METHOD THE
 PLANS WERE DEVELOPED. FOR THIS REVIEW THE REVIEWER WILL
 BE USING BOTH THE 2017 FBC-B AND THE 2017 EXIST.
 BUILDING CODE CHAPTER 10 CHANGE OF OCCUPANCY SECTION
 1001.2.2. CHANGE OF OCCUPANCY CLASSIFICATION OR GROUP.
 WHERE THE OCCUPANCY CLASSIFICATION OF A BUILDING
 CHANGES, THE PROVISIONS OF SECTIONS 1002 THROUGH 1012
 SHALL APPLY. THIS INCLUDES A CHANGE OF OCCUPANCY
 CLASSIFICATION AND A CHANGE TO ANOTHER GROUP WITHIN AN
 OCCUPANCY CLASSIFICATION.
  
 THIS BUILDING WE COULD NOT FIND A BUSINESS TAX RECEIPT
 / BUT PALM BEACH COUNTY PROPERTY APPRAISERS HAS THE
 OCCUPANCY TYPE LISTED AS WAREHOUSE/ STORAGE. THAT IS
 WHY WE ARE LISTING THIS REVIEW AS A CHANGE IN
 OCCUPANCY/ CHANGE IN USE.
  
 4A) PLEASE SHOW COMPLIANCE WITH THE 2017 EXIST. BUILD.
 CODE SECTION 1002.1 COMPLIANCE WITH THE BUILDING CODE.
 WHERE THE CHARACTER OR USE OF AN EXISTING BUILDING OR
 PART OF AN EXISTING BUILDING IS CHANGED TO ONE OF THE
 FOLLOWING SPECIAL USE OR OCCUPANCY CATEGORIES AS
 DEFINED IN THE FLORIDA BUILDING CODE, BUILDING, THE
 BUILDING SHALL COMPLY WITH ALL OF THE APPLICABLE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING:
 406.3.MOTOR VEHICLE-RELATED OCCUPANCIES.
 EXIST BLDG. CODE 406.4.6 MIXED OCCUPANCY SEPARATION.
 PARKING GARAGES SHALL BE SEPARATED FROM OTHER
 OCCUPANCIES IN ACCORDANCE WITH SECTION 508.1 OF THE
 FBC-B. WHERE A BUILDING CONTAINS MORE THAN ONE
 OCCUPANCY GROUP, THE BUILDING OR PORTION THEREOF SHALL
 COMPLY WITH THE APPLICABLE PROVISIONS OF SECTION 508.2,
 508.3 OR 508.4, OR A COMBINATION OF THESE SECTIONS.
 PLEASE NOTE PARKING GARAGES ARE PART OF THE SPECIALTY
 OCCUPANCIES FOUND IN CHAPTER 4 AND WILL REQUIRE FIRE
 SEPARATION AS PER TABLE 508.4 OF THE FBC-B. PLEASE ALSO
 NOTE FOOTNOTE B. THE REQUIRED SEPARATION FROM AREAS
 USED ONLY FOR PRIVATE OR PLEASURE VEHICLES SHALL BE
 REDUCED BY 1 HOUR BUT NOT LESS THAN 1 HOUR. OPENING
 PROTECTIVES FOR DOORS CAN BE FOUND UNDER THE FBC-B
 TABLE 716.5. PRIVATE GARAGES UNDER 1,000 SQ. IS TO BE
 CONSIDERED AN U OCCUPANCY (UTILITY). IN THE 2017 FBC-B
 406.3.1 THE CLASSIFICATION FOR A PRIVATE GARAGE AS
 UTILITY STILL REQUIRES A 1 HOUR FIRE BARRIER IN
 COMPLIANCE WITH SECTION 707 OF THE FBC-B.
  
 4B) PLEASE NOTE THAT PRIVATE GARAGES NEED ONLY TO
 COMPLY WITH 406.3.1 THROUGH 406.3.6. VENTILATION
 REQUIREMENTS FOUND UNDER 406.6.2 ARE NOT REQUIRED!
  
 5A) THE IDEA OF CALLING THIS STRUCTURE A LIVE/ WORK
 UNIT DOES NOT MEET THE CRITERIA FOUND IN SECTION
 419.1.1 LIMITATIONS OF THE 2017 FBC-B. THE
 NON-RESIDENTIAL AREA IS PERMITTED TO BE NOT GREATER
 THAN50 % OF THE AREA OF EACH LIVE/ WORK UNITS.
  
 5B) THE OTHER OCCUPANCY SEPARATION THAT WILL NEED TO
 OCCUR IS THE RESIDENTIAL R-3 VERSES THE A-3 OCCUPANCY
 (GALLERY). TABLE 508.4 OF THE 2017 FBC-B WILL ALSO
 REQUIRE A 1 HOUR FIRE SEPARATION PER TABLE 508.4 FOR A
 SPRINKLERED BUILDING.
  
 6) SHEET A.1.1 SHOWS A NEW STOREFRONT DOORS AND GARAGE
 DOOR PLEASE PROVIDE COMPLIANCE WITH:
 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS ,OVERHEAD GARAGE DOOR
 (B) WINDOWS AND MULLIONS (POSSIBLE SIDELIGHTS)
  
 7) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE
 PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF
 RECORD AND BEFORE SUBMISSION TO THE BUILDING
 DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE
 IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING,
 MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED
 INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE
 PRESSURES FOR EACH OPENING SIZE. 2017 FBC-B 1405.13.1
 INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN
 ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS.
 FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH
 INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM
 LOADS AND SPACING USED IN THE TESTS.
  
 8) W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 9) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF
 THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
  
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 10) SHEET S01 PROVIDES THE WIND DESIGN CRITERIA. BUT
 THE NEGATIVE PRESSURES ARE ABOUT 2.0 PSF LOW FOR
 EXPOSURE C. THE MEAN ROOF HEIGHT IS NOT GIVEN, NEGATIVE
 PRESSURES ARE TO BE TAKEN AT THE ROOF LINE. 2017 FBC-B
 1603.1.4 WIND DESIGN DATA. WIND EXPOSURE. APPLICABLE
 WIND DIRECTION IF MORE THAN ONE WIND EXPOSURE IS
 UTILIZED. TABLE 1609.7.2. HEIGHT AND EXPOSURE. TABLE
 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & EXPOSURE.
 PROVIDE THE MEAN ROOF HEIGHT FOR THE BUILDING. 1609.3.1
 WIND SPEED CONVERSION VULT TO VASD.
  
 11) PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
 19120504
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  
  
 12) IMPACT FEES - DIGITAL SUBMITTALS: PLANS WILL BE
 REVIEWED BY THE PBC IMPACT FEE OFFICE DIGITALLY VIA
 PROJECT DOX UPON NOTIFICATION BY THIS OFFICE.
 NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST FINAL
 FORM. YOU MAY COORDINATE WITH THE IMPACT FEE OFFICE AT
 (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL IMPACT
 FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME THE
 FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM CAN
 BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRAT
 ION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL.
  
  
 13). A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717 / FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-10-17 Cont ID  
Sent By jleahy Date 2020-10-17 Time 12:16 Rev Time 0.00
Received By jleahy Date 2020-10-17 Time 11:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-07-09 Cont ID  
Sent By jleahy Date 2020-07-09 Time 19:01 Rev Time 0.00
Received By jleahy Date 2020-07-09 Time 18:31 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2020-06-11 Cont ID  
Sent By pleduc Date 2020-06-11 Time   Rev Time 0.00
Received By pleduc Date 2020-06-11 Time 11:27 Sent To  
Notes
2020-06-11 11:28:11THIS APPEARS TO BE A CHANGE OF OCCUPANCY FOR MIXED
 BUSINESS/RESIDENTIAL TO A SINGLE FAMILY HOME AND A LIFE
 SAFETY REVIEW BY FIRE IS NOT REQUIRED.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 3 Status N Date 2020-10-16 Cont ID  
Sent By ccole Date 2020-10-16 Time 07:48 Rev Time 0.00
Received By ccole Date 2020-10-15 Time 07:48 Sent To  
Notes
2020-10-16 07:50:40GAS PIPING INSTALLATIONS UNDER PERMIT- 20090700.

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2020-09-25 Cont ID  
Sent By ccole Date 2020-09-25 Time 10:27 Rev Time 0.00
Received By ccole Date 2020-09-25 Time 10:26 Sent To  
Notes
2020-09-25 10:29:02SEPARATE PERMITS ARE REQUIRED FOR THE GENERATOR AND THE
 GAS PIPING TO THE GENERATOR, WATER HEATER, AND RANGE
 SHOWN ON THE PLAN.
 THE GAS PIPING PERMIT SUBMITTAL SHALL INCLUDE THE GAS
 RISER AND FLAT LINE DRAWINGS, COMBUSTION AIR
 CALULATIONS FOR THE RANGE, SIZING TABLES FOR GAS
 PIPING, AND MANUFACTURER'S DATA AND SPECS FOR THE
 RANGE, GENERATOR, WATER HEATER, AND REGULATORS, MAKES
 AND MODELS OF SELECTED REGULATORS SHALL BE ON THE
 DRAWINGS AND THE SPECS SHALL BE MARKLED UP TO INDCATE
 PRESSURE RATINGS AND ORIFICE SIZES.
 CCOLE- 9/25/2020

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2020-07-16 Cont ID  
Sent By ccole Date 2020-07-16 Time 08:29 Rev Time 0.00
Received By ccole Date 2020-07-16 Time 08:28 Sent To  
Notes
2020-07-16 08:35:23SEPARATE PERMITS ARE REQUIRED FOR THE GENERATOR AND GAS
 PIPING SHOWN ON THE PLAN.
 THE GAS PIPING PERMIT SUBMITTAL SHALL INCLUDE THE GAS
 RISER AND FLAT LINE DRAWINGS, COMBUSTION AIR
 CALULATIONS FOR THE RANGE, SIZING TABLES FOR GAS
 PIPING, AND MANUFACTURER'S DATA AND SPECS FOR THE
 RANGE, GENERATOR AND REGULATORS, MAKES AND MODELS OF
 SELECTED REGULATORS SHALL BE ON THE DRAWINGS AND THE
 SPECS SHALL BE MARKLED UP TO INDCATE PRESSURE RATINGS
 AND ORIFICE SIZES.
 CCOLE-7/16/2020

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2020-10-26 Cont ID  
Sent By shill Date 2020-10-26 Time 13:01 Rev Time 0.00
Received By shill Date 2020-10-22 Time 15:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2020-10-19 Cont ID  
Sent By ccole Date 2020-10-19 Time 17:47 Rev Time 0.00
Received By ccole Date 2020-10-14 Time 11:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status F Date 2020-10-13 Cont ID  
Sent By rgathrig Date 2020-10-13 Time 16:00 Rev Time 0.00
Received By shill Date 2020-09-17 Time 07:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-08-03 Cont ID  
Sent By shill Date 2020-08-03 Time 14:38 Rev Time 0.00
Received By shill Date 2020-07-20 Time 13:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-20 Cont ID  
Sent By lmarchan Date 2020-07-20 Time 08:19 Rev Time 0.00
Received By lmarchan Date 2020-07-07 Time 13:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-22 Cont ID  
Sent By lmarchan Date 2020-06-22 Time 13:35 Rev Time 0.00
Received By lmarchan Date 2020-06-10 Time 10:16 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2020-11-13 Cont ID  
Sent By ccarvaja Date 2020-11-13 Time 15:37 Rev Time 0.00
Received By lmarchan Date 2020-09-17 Time 07:43 Sent To  
Notes
2020-11-13 15:37:42RECEIPT MU-2020-043828 - $5613.27 - PAID
2020-09-17 07:43:289/17/20 EMAILED IMPACT FEE OFFICE. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-06-17 Cont ID  
Sent By jwitmer Date 2020-06-17 Time 10:02 Rev Time 0.00
Received By jwitmer Date 2020-06-17 Time 10:01 Sent To  
Notes
2020-06-17 10:02:26IMPACT FEES - DIGITAL SUBMITTALS:
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2020-09-25 Cont ID  
Sent By medwards Date 2020-09-25 Time 09:24 Rev Time 0.00
Received By medwards Date 2020-09-25 Time 08:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-07-28 Cont ID  
Sent By hmoser Date 2020-07-28 Time 13:14 Rev Time 0.00
Received By hmoser Date 2020-07-28 Time 12:28 Sent To  
Notes
2020-07-28 13:23:01NO AIR CONDITIONING PLAN OR CALCULATIONS SUBMITTED WITH
 PLAN
 SEC 107 FBC 2017. NO COMMENTS FROM THE ENGINEER ON THE
 LAST TWO REVIEWS
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-07-18 Cont ID  
Sent By medwards Date 2020-07-18 Time 15:09 Rev Time 0.00
Received By medwards Date 2020-07-18 Time 14:34 Sent To  
Notes
2020-07-18 15:09:591ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20060031
  
 CODES IN EFFECT:
  
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE ENERGY CALCULATIONS GAUGE AND MANUAL
 J. FBC EC 101.5.1.1.2
  
 2) PROVIDE VENTILATION CALCULATIONS FOR THIS NEW SF
 OCCUPANCY. FBC M 401.2
  
 3) PROVIDE MANUAL J CALCULATIONS FOR THE MECHANICAL
 SYSTEM. FBC EC R 403.7
  
 4) PROVIDE INFORMATION ON THE OUTDOOR CONDENSER
 ANCHORAGE. FBC RES M1307.2
  
 5) PROVIDE MECHANICAL SHEETS SHOWING THE MECHANICAL
 SYSTEM INCLUDING ALL EQUIPMENT AND DUCT WORK. FBC FS
 107.2.1
  
 6) PROVIDE ON THE DRAWING, HOW THE MECHANICAL SYSTEM
 WILL HAVE A BALANCED RETURN AIR SYSTEM. FBC RES M1602.3
  
 7) PLEASE PROVIDE SPEC SHEET SON THE KITCHEN RANGE AND
 ASSOCIATED HOOD. FBC FS 107.2.1
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2020-10-19 Cont ID  
Sent By ccole Date 2020-10-19 Time 17:46 Rev Time 0.00
Received By ccole Date 2020-10-15 Time 07:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2020-09-25 Cont ID  
Sent By ccole Date 2020-09-25 Time 10:23 Rev Time 0.00
Received By ccole Date 2020-09-25 Time 08:50 Sent To  
Notes
2020-09-25 10:25:083RD REVIEW FBC-2017 RES. PLUMBING
 PERMIT- 20060031
 9/25/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
 AS PREVIOUSLY NOTED IN THE FUEL GAS REVIEW OF THE
 PROJECT ON 7/16/20 THE GAS PIPING AND THE GENERATOR
 INSTALLATIONS SHALL BE UNDER SEPARATE PERMIT. PLEASE
 PLACE A LARGE BOLD NOTE ON THE PLANS FOR CLARIFICATION.
 A REVIEW OF THE GAS PLANS AND GENERATOR WILL NOT BE
 PERFORMED AT THIS TIME- SECTION 107.1 WPB.
  
 1) THE MISSING PLAN SHEET PS1.1 HAS BEEN PROVIDED WHICH
 IS MORE GAS PIPING AND GENERATOR INFORMATION, HOWEVER A
 WATER RISER FOR THE PROJECT HAS NOT BEEN PROVIDED. NEW
 PLAN SHEETS INDICATE AN EXTERIOR GAS-FIRED TANKLESS
 WATER HEATER HAS BEEN ADDED. SHEET P1.1: PLEASE PROVIDE
 A WATER RISER AND A FLAT LINE DRAWING SHOWING THE HOT
 AND COLD WATER SUPPLY RUNS FROM THE NEW WATER HEATER
 LOCATION TO THE NEW AND RELOCATED PLUMBING FIXTURES AND
 APPLIANCES- SECTION P2903 FBC RES & SECTION 107.2.1
 WPB.
  
 1A) SHOW LOCATIONS WHERE PIPING WILL BE RUN UNDERSLAB.
 INDICATE THE TYPE OF PIPING AND HOW IT WILL BE
 PROTECTED FROM CORROSION- SECTION P2603.3 FBC RES.
  
 1B) PLEASE SHOW THE LOCATIONS OF ALL REQUIRED WATER
 HAMMER ARRESTORS AND BACKFLOW PREVENTERS- SECTIONS
 P2902.3 & P2903.5 FBC RES.
  
 1C) LIST THE MAKE AND MODEL OF THE NEW WATER HEATER ON
 THE PLAN AND SUBMIT MANUFACTURER'S SPECIFICATIONS. THE
 SPECS SUBMITTED SHALL INCLUDE THE EFFICIENCY RATING,
 AND A TEMPERATURE RISE CHART FOR SIZING THE REQUIRED
 GPM FLOW TO THE FIXTURES- SECTIONS G2448.1, P2903.1 FBC
 RES. AND TABLE C404.2 FBC EC.
  
 1D) INDICATE THE HOT WATER PIPES WILL INSULATED WITH
 R-3 PIPE INSULATION- SECTION R403.5.3 FBC RES.
  
 2) SHEETS A-001, P1.1: SHOW SLAB CUT LOCATIONS FOR NEW
 UNDERSLAB DRAIN PIPING INSTALLATIONS AND PROVIDE A SLAB
 REPAIR DETAIL- SECTION 107.21 WPB AND SECTION R318.1.3
 FBC RES. PLEASE NOTE THE HORIZONTAL DISTANCE FROM THE
 CENTERLINE OF THE NEW SHOWER DRAIN OUTLET TO THE
 CENTERLINE OF THE INLET OF THE EXISTING TRAP SHALL NOT
 EXCEED 30 IN- SECTION P3201.6 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-07-21 Cont ID  
Sent By ccole Date 2020-07-21 Time 09:28 Rev Time 0.00
Received By ccole Date 2020-07-21 Time 07:48 Sent To  
Notes
2020-07-21 09:30:382ND REVIEW FBC-2017 RES. PLUMBING
 PERMIT- 20060031
 7/20/2020
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 COMMENTS PRINTED BELOW FROM THE 1SR REVIEW WERE NOT
 ADDRESSED- PLEASE COMPLY.
 PLEASE NOTE THAT SEPARATE PERMITS ARE REQUIRED FOR THE
 GENERATOR AND THE GAS PIPING.
  
 1) SHEET P0.1: THE INDEX INDICATES THERE IS A MISSING
 PLAN (SHEET P2.1) WHICH WAS NOT UPLOADED FOR REVIEW-
 SECTION 107.2.1 WPB.
  
 2) PROVIDE A SHOWER PAN DETAIL PER SECTIONS P2709.1 &
 P2709.2 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-07-16 Cont ID  
Sent By ccole Date 2020-07-16 Time 08:22 Rev Time 0.00
Received By ccole Date 2020-07-16 Time 07:39 Sent To  
Notes
2020-07-16 08:23:381ST REVIEW FBC-2017 RES. PLUMBING
 PERMIT- 20060031
 7/16/2020
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P0.1: THE INDEX INDICATES THERE IS A MISSING
 PLAN (SHEET P2.1) WHICH WAS NOT UPLOADED FOR REVIEW-
 SECTION 107.2.1 WPB.
  
 2) PROVIDE A SHOWER PAN DETAIL PER SECTIONS P2709.1 &
 P2709.2 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status P Date 2020-10-26 Cont ID  
Sent By rgathrig Date 2020-10-26 Time 16:48 Rev Time 0.00
Received By rgathrig Date 2020-10-26 Time 16:47 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status F Date 2020-10-15 Cont ID  
Sent By rgathrig Date 2020-10-15 Time 16:23 Rev Time 0.00
Received By rgathrig Date 2020-10-15 Time 16:20 Sent To  
Notes
2020-10-15 16:23:01PRIVATE PROVIDER REVIEW FOR INSPECTIONS HAS FAILED
  
 NOTHING NEW HAS BEEN SUBMITTED FOR THIS REVIEW CYCLE TO
 ADDRESS THE FIRST REVIEW COMMENTS
  
 RICHARD GATHRIGHT
 561-805-6679

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2020-09-18 Cont ID  
Sent By rgathrig Date 2020-09-18 Time 16:40 Rev Time 0.00
Received By rgathrig Date 2020-09-10 Time 12:04 Sent To  
Notes
2020-09-18 16:40:26PRIVATE PROVIDER REVIEW IS NOT APPROVED
 INSURANCE CERTIFICATE FOR PROFESSIONAL LIABILITY ?C?
 NEEDS TO STATE THAT THE INSURANCE IS ISSUED FOR
 SERVICES PERFORMED AS A PROVIDER AS STATED IN FLORIDA
 STATUTE 553.791(16). PLEASE SEE BELOW. ALSO THE
 CERTIFICATE SUBMITTED EXPIRES 10/23/2020
  
 FS 553.791 (16) A PRIVATE PROVIDER MAY PERFORM BUILDING
 CODE INSPECTION SERVICES ON A BUILDING PROJECT UNDER
 THIS SECTION ONLY IF THE PRIVATE PROVIDER MAINTAINS
 INSURANCE FOR PROFESSIONAL LIABILITY COVERING ALL
 SERVICES PERFORMED AS A PRIVATE PROVIDER. SUCH
 INSURANCE SHALL HAVE MINIMUM POLICY LIMITS OF $1
 MILLION PER OCCURRENCE AND $2 MILLION IN THE AGGREGATE
 FOR ANY PROJECT WITH A CONSTRUCTION COST OF $5 MILLION
 OR LESS AND $2 MILLION PER OCCURRENCE AND $4 MILLION IN
 THE AGGREGATE FOR ANY PROJECT WITH A CONSTRUCTION COST
 OF OVER $5 MILLION. NOTHING IN THIS SECTION LIMITS THE
 ABILITY OF A FEE OWNER TO REQUIRE ADDITIONAL INSURANCE
 OR HIGHER POLICY LIMITS. FOR THESE PURPOSES, THE TERM
 ?CONSTRUCTION COST? MEANS THE TOTAL COST OF BUILDING
 CONSTRUCTION AS STATED IN THE BUILDING PERMIT
 APPLICATION. IF THE PRIVATE PROVIDER CHOOSES TO SECURE
 CLAIMS-MADE COVERAGE TO FULFILL THIS REQUIREMENT, THE
 PRIVATE PROVIDER MUST ALSO MAINTAIN COVERAGE FOR A
 MINIMUM OF 5 YEARS SUBSEQUENT TO THE PERFORMANCE OF
 BUILDING CODE INSPECTION SERVICES. THE INSURANCE
 REQUIRED UNDER THIS SUBSECTION SHALL BE WRITTEN ONLY BY
 INSURERS AUTHORIZED TO DO BUSINESS IN THIS STATE WITH A
 MINIMUM A.M. BEST?S RATING OF A. BEFORE PROVIDING
 BUILDING CODE INSPECTION SERVICES WITHIN A LOCAL
 BUILDING OFFICIAL?S JURISDICTION, A PRIVATE PROVIDER
 MUST PROVIDE TO THE LOCAL BUILDING OFFICIAL A
 CERTIFICATE OF INSURANCE EVIDENCING THAT THE COVERAGES
 REQUIRED UNDER THIS SUBSECTION ARE IN FORCE THE
 OWNER/AGENT OF THE PROPERTY IS JOHN CERIALE. THE NOTICE
 TO BUILDING OFFICIAL IS SIGNED BY MELISSA CERIALE. JOHN
 CERIALE MUST SIGN
  
  
 RICHARD GATHRIGHT
 ASSISTANT BUILDING OFFICIAL
 561-805-6679
2020-09-10 12:04:21NOTICE TO BUILDING OFFICIAL SUBMITTED ON 9/9/20. ROUTED
 TO RICHARD GATHRIGHT.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-10-16 Cont ID  
Sent By shill Date 2020-10-16 Time 18:53 Rev Time 0.00
Received By shill Date 2020-10-16 Time 18:53 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-08-03 Cont ID  
Sent By shill Date 2020-08-03 Time 14:52 Rev Time 0.00
Received By shill Date 2020-08-03 Time 14:51 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-07-18 Cont ID  
Sent By medwards Date 2020-07-18 Time 15:17 Rev Time 0.00
Received By medwards Date 2020-07-18 Time 15:10 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2020-09-25 Cont ID  
Sent By llouie Date 2020-09-25 Time   Rev Time 0.00
Received By llouie Date 2020-09-25 Time   Sent To  
Notes
2020-09-25 14:45:10REFERENCE:
  
 * SFR - INTERIOR CHANGES TO EXISTING BUILDING AND
 EXTERIOR IMPROVEMENTS.
  
 * REFERENCE: LANDSCAPE PERMIT #20090779
  

Review Stop Z ZONING
Rev No 3 Status F Date 2020-07-22 Cont ID  
Sent By llouie Date 2020-07-22 Time   Rev Time 0.00
Received By llouie Date 2020-07-22 Time   Sent To  
Notes
2020-07-22 09:37:21** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE [NOTE: APPLICANT RESPONSES TO ZONING?S
 COMMENTS HAVE NOT BEEN PROVIDED]:
  
 1.) SURVEY OF THE PROPERTY IS OVER A YEAR OLD AND DOES
 NOT SEEM TO REFLECT ALL EXISTING STRUCTURES ON THE
 PROPERTY (I.E. NORTH PRIVACY WALL). PLEASE PROVIDE AN
 UPDATED AND ACCURATE SURVEY OF THE PROPERTY. PLEASE
 NOTE THAT ANY EXISTING STRUCTURES THAT ARE TO REMAIN ON
 THE PROPERTY SHOULD ALSO BE REFLECTED IN THE SITE PLAN.
 [6/19/2020 AND 7/14/2020 REPEAT COMMENT: SURVEY
 DOCUMENT HAS NOT BEEN UPDATED.]
  
 2.) CLARIFY THE PROPOSED USE ON THE PROPERTY.
 [6/19/2020 AND 7/14/2020 REPEAT COMMENT: AS NOTED
 ABOVE, PLEASE PROVIDE RESPONSE TO ZONING?S COMMENTS IN
 WRITING AND ON THE PLANS.]
  
 3.) A SITE PLAN SHOWING THE DIMENSIONS OF THE PROPERTY,
 STRUCTURAL SETBACKS, AND ANY OTHER PROPOSED IMPROVEMENT
 TO THE SITE SHALL BE PROVIDED. INCLUDE SITE
 CALCULATIONS (I.E. LANDSCAPE AREA, PERVIOUS/IMPERIOUS
 SPACE, ETC.] [6/19/2020 AND 7/14/2020 MODIFIED/REPEAT
 COMMENT: REQUESTED SITE CALCULATIONS STILL MISSING FROM
 THE PLAN]
  
 4.) PROPOSED SETBACKS FOR THE GENERATOR DOES NOT MEET
 THE MINIMUM SETBACKS REQUIREMENTS OF THE CITY?S ZONING
 CODE. THE GENERATOR SHALL BE SETBACK A MINIMUM OF AT
 LEAST 11 FT. FROM THE REAR PROPERTY LINE AND 6 FT. FROM
 THE EAST SIDE PROPERTY LINE. [ZLDR S.94-305(B)(4)]
  
 5.) WHERE IS THE LOCATION OF THE A/C COMPRESSOR UNIT?
 IS IT ON THE ROOFTOP OR GROUND LEVEL? LOCATION MUST BE
 SHOWN IN THE SITE PLAN WITH SETBACK DIMENSIONS IF
 PROVIDED ON THE GROUND LEVEL. UNIT MUST BE SCREENED
 FROM VIEW IF PLACED ON THE ROOFTOP. [ZLDR
 S.94-305(B)(4)] [6/19/2020 AND 7/14/2020
 MODIFIED/REPEAT COMMENT]
  
 6.) THE VALUE OF THE CONSTRUCTION FROM PERMITS
 TABULATED FOR THE YEAR EXCEEDS 50% OF THE STRUCTURE'S
 VALUE ($244,443.00) ACCORDING TO THE P.B.C. PROPERTY
 APPRAISER'S OFFICE; THEREFORE, PURSUANT TO SECTION
 94-441(C)(2) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE
 IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN
 ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO
 ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN
 DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE
 PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO
 ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS
 PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION
 PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE
 SITE INTO CONFORMITY. [6/19/2020 AND 7/14/2020 REPEAT
 COMMENT: THERE IS NO RECORD OF A SEPARATE LANDSCAPE
 PERMIT IN THE SYSTEM.]
  
 7.) LANDSCAPE PLANS SHALL BE REMOVED FROM THIS PERMIT
 AND SUBMITTED AS A SEPARATE LANDSCAPE PERMIT.
 [6/19/2020 AND 7/14/2020 REPEAT COMMENT: THERE IS NO
 RECORD OF A SEPARATE LANDSCAPE PERMIT IN THE SYSTEM.]
  
  
 NOTES:
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * FLU: MF AND ZONE: POR (REFERENCE: NEXT TO CAREFREE
 SITE)
  
 * RESIDENTIAL PERMITTED IN POR.
  

Review Stop Z ZONING
Rev No 2 Status F Date 2020-07-14 Cont ID  
Sent By llouie Date 2020-07-14 Time   Rev Time 0.00
Received By llouie Date 2020-07-14 Time   Sent To  
Notes
2020-07-14 10:14:16** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) SURVEY OF THE PROPERTY IS OVER A YEAR OLD AND DOES
 NOT SEEM TO REFLECT ALL EXISTING STRUCTURES ON THE
 PROPERTY (I.E. NORTH PRIVACY WALL). PLEASE PROVIDE AN
 UPDATED AND ACCURATE SURVEY OF THE PROPERTY. PLEASE
 NOTE THAT ANY EXISTING STRUCTURES THAT ARE TO REMAIN ON
 THE PROPERTY SHOULD ALSO BE REFLECTED IN THE SITE PLAN.
 [6/19/2020 MODIFIED/REPEAT COMMENT]
  
 2.) CLARIFY THE PROPOSED USE ON THE PROPERTY.
 [6/19/2020 REPEAT COMMENT]
  
 3.) A SITE PLAN SHOWING THE DIMENSIONS OF THE PROPERTY,
 STRUCTURAL SETBACKS, AND ANY OTHER PROPOSED IMPROVEMENT
 TO THE SITE SHALL BE PROVIDED. INCLUDE SITE
 CALCULATIONS (I.E. LANDSCAPE AREA, PERVIOUS/IMPERIOUS
 SPACE, ETC.] [6/19/2020 MODIFIED/REPEAT COMMENT]
  
 4.) SHOW LOCATION OF ALL MECHANICAL EQUIPMENT (I.E. A/C
 UNIT PAD, PROPOSED GENERATOR) WITH PROPOSED SETBACKS
 FROM PROPERTY LINE. PLEASE NOTE THAT PER ZLDR S.94-305
 ANY MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4
 FT. INTO A REQUIRED SETBACK - PLACEMENT OF THE PROPOSED
 GENERATOR DOES NOT COMPLY WITH THIS SETBACK
 REQUIREMENT. WHERE IS THE PROPOSED A/C COMPRESSOR UNIT?
 [6/19/2020 MODIFIED/REPEAT COMMENT]
  
 5.) THE VALUE OF THE CONSTRUCTION FROM PERMITS
 TABULATED FOR THE YEAR EXCEEDS 50% OF THE STRUCTURE'S
 VALUE ($244,443.00) ACCORDING TO THE P.B.C. PROPERTY
 APPRAISER'S OFFICE; THEREFORE, PURSUANT TO SECTION
 94-441(C)(2) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE
 IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN
 ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO
 ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN
 DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE
 PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO
 ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS
 PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION
 PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE
 SITE INTO CONFORMITY. [6/19/2020 REPEAT COMMENT]
  
 6.) LANDSCAPE PLANS SHALL BE REMOVED FROM THIS PERMIT
 AND SUBMITTED AS A SEPARATE LANDSCAPE PERMIT.
 [6/19/2020 REPEAT COMMENT]
  
  
 NOTES:
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * FLU: MF AND ZONE: POR (REFERENCE: NEXT TO CAREFREE
 SITE)
  
 * RESIDENTIAL PERMITTED IN POR.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2020-06-19 Cont ID  
Sent By llouie Date 2020-06-19 Time   Rev Time  
Received By llouie Date 2020-06-19 Time   Sent To  
Notes
2020-06-19 14:36:24** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) UPDATED SURVEY OF THE PROPERTY IS MISSING FROM THE
 PERMIT SUBMITTAL.
  
 2.) CLARIFY THE PROPOSED USE ON THE PROPERTY.
  
 3.) A SITE PLAN SHOWING THE DIMENSIONS OF THE PROPERTY,
 STRUCTURAL SETBACKS, AND ANY OTHER PROPOSED IMPROVEMENT
 TO THE SITE SHALL BE PROVIDED.
  
 4.) SHOW LOCATION OF ANY MECHANICAL EQUIPMENT (I.E. A/C
 UNIT PAD) WITH PROPOSED SETBACKS FROM PROPERTY LINE.
  
  
 5.) EXTERIOR CHANGES TO THE BUILDING DETECTED THAT WILL
 REQUIRE THE APPLICANT TO SUBMIT BUILDING ELEVATION
 DRAWINGS.
  
 6.) THE VALUE OF THE CONSTRUCTION FROM PERMITS
 TABULATED FOR THE YEAR EXCEEDS 50% OF THE STRUCTURE?S
 VALUE ($244,443.00) ACCORDING TO THE P.B.C. PROPERTY
 APPRAISER'S OFFICE; THEREFORE, PURSUANT TO SECTION
 94-441(C)(2) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE
 IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN
 ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO
 ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN
 DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE
 PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO
 ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS
 PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION
 PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE
 SITE INTO CONFORMITY.
 LANDSCAPE PLANS SHALL BE REMOVED FROM THIS PERMIT AND
 SUBMITTED AS A SEPARATE LANDSCAPE PERMIT.
  
  
 NOTES:
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * FLU: MF AND ZONE: POR (REFERENCE: NEXT TO CAREFREE
 SITE)
  
 * RESIDENTIAL PERMITTED IN POR.
  