| Plan Review Stops For Permit 20050940 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-08-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-08-21 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-08-21 |
Time |
11:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2020-08-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-08-20 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-08-20 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2020-08-20 16:41:29 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, PLEASE PROVIDE AN UPDATED DETAIL FOR THE | | | CAST IN PLACE GENERATOR SLAB DETAIL INCLUDING THE | | | LENGTH OF THE 3/8" BOLTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-08-08 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-08-08 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-08-08 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2020-08-08 10:53:23 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING REVIEW DENIED: | | | | | | 1) PROVIDE WIND DESIGN LOADS FOR THE GENERATOR PER FBC | | | 107.3.5.3 AND R301.2 AS REQUIRED FOR THE GENERATOR PAD | | | ENGINEERING. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-07-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-27 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-27 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2020-07-27 14:16:13 | PLAN REVIEW ? GENERATOR - BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) PROVIDE WIND DESIGN LOADS FOR THE GENERATOR PER FBC | | | 107.3.5.3 AND R301.2 AS REQUIRED FOR THE GENERATOR PAD | | | ENGINEERING. | | | 2) STRUCTURAL DETAIL OF PAD AND DESIGN LOADS SHALL BE | | | SIGNED AND SEALED BY A DESIGN PROFESSIONAL. | | | 3) PROVIDE STRUCTURAL DETAIL OF GENERATOR PAD. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-07-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-27 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-27 |
Time |
11:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-07-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-27 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-27 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2020-07-27 14:20:06 | SEPERATE GAS PERMIT REQUIRED. CT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-08-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-08-21 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-08-21 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-08-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-08-20 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-08-10 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-08-08 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-08-08 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-07-29 |
Time |
07:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-07-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-27 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-07 |
Time |
16:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2020-07-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-27 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-27 |
Time |
11:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2020-08-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-08-21 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-08-21 |
Time |
11:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-08-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-08-20 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-08-20 |
Time |
16:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-08-08 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-08-08 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-08-08 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2020-08-08 11:14:43 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | SIGNATURE REVIEW DENIED: | | | | | | FBC B 107.2, WPB AMENDMENTS 107.2.1, THE DESIGNER OF | | | THE SLAB NEEDS TO RESUBMIT THE SLAB DETAIL INTO PROJECT | | | DOX WITH DIGITAL VERIFICATION OF SIGNATURE OR DROP OFF | | | THE ORIGINAL PAPER DOCUMENTS THAT REQUIRE A SIGNATURE | | | TO THE BUILDING DEPARTMENT DROP BOX AT THE ENTRY TO | | | CITY HALL. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-07-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-07-27 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-07-27 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2020-07-27 14:17:08 | PLAN REVIEW GENERATOR - DIGITAL SIGNATURES AND SEALS | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON | | | ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC 61G15 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-07-10 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-07-10 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2020-07-10 |
Time |
|
Sent To |
I |
|
| Notes |
|
|